merten MEG6910-0033 U Motion Door Station Set Instruction Manual

June 3, 2024
merten

U.motion Door station set, 1 unit
U.motion Door station set, 2 units
Installation and configuration instructionsmerten MEG6910 0033 U Motion
Door Station Set -

Contents

  • Stainless steel video door station (7) for Ritto IP (referred to below as door station)
    – 1 bell push-button / 2 bell push-buttons
    – Pre-installed colour video camera
    – IP Built-in video loudspeaker
    – Flush-mounted box

  • IP switching device (6)

  • Video encoder (1)

  • Passive video transceiver (2)

  • Circuit diagram

  • Safety instructions

For your safety
DANGER
Electrical installations not carried out correctly represent a risk of serious personal injury and/or damage to property, for exam Safe electrical installation is only guaranteed if the person carrying out the work can demonstrate basic knowledge in the following areas:

  • Connecting to installation networks
  • Connecting several electrical devices
  • Laying electric cables
  • Laying network cables and guaranteeing interference resistance
  • Connecting and establishing local IP networks

These skills and experience are normally technology. If these minimum requirements are not met or are disregarded in any way, you will be solely liable for any damage to property or personal injury.

Trademarks

AXIS COMMUNICATIONS, AXIS, ETRAX, ARTPEC and VAPIX are registered trademarks of Axis AB in various jurisdictions. The Axis logo is a registered trademark of Axis AB.
Other brands and registered trademarks are the property of the relevant owner.

Getting to know the U.motion door station set
This set enables you to establish an intercom connection (audio/video) from the supplied door station (7) to an intercom-capable device from U.motion. Intercom-capable devices include U.motion touch panels, PCs with browsers (Google Chrome, Apple Safari) and the U.motion communication app.
A door station with 1 or 2 bell push-buttons is also available depending on the set. The device uses PoE and must be connected to a PoE-capable network.
The supplied IP switching device (6) has two potential-free switch outputs by means of which you can control an electric door opener and switch on the staircase light.
The IP switching device needs an AC 230 V supply voltage; the device provides AC 9 V / 600 mA for controlling the door opener.
The supplied video encoder (1) converts analogue video signals from the door station into network-compatible signals for the. The device uses PoE and must be connected to a PoE-capable network.
These step-by-step instructions show you how to take the set into operation. In addition, each product is supplied with operating instructions that refer to special device functions in more detail.

Additional requirements and prerequisites
Recommendation: Use Cat 5 network cables (or better) to minimise interference.

  • AXIS IP utility: These software applications can be found on the CD supplied with the video encoder.
  • This software application forms part of the U.motion KNX Server Plus.
  • IP Setup software: You can find the software application on the door sation CD.

The computer running the software applications and the devices must be in the same network segment (subnet).

Overview of connections

merten MEG6910 0033 U Motion Door Station Set - Overview of
connections

  1. Video encoder
  2. Passive video transceiver
  3. PoE switch
  4. U.motion KNX Server Plus
  5. Power supply
  6. IP switching device with door opener
  7. Door station

Operating elements and LED displays of the video encoder

| | Behaviour| Meaning
---|---|---|---
PWR| Mains| Green
Green/yellow, flashing| Normal operation Firmware update
STAT| Status| Green
Yellow
Red, flashing slowly| Normal operation
Switching on, restoring the factory settings and previous settings
Update error
NET| Network| Green
Yellow
Flashing Off| Connection to a 100 Mbit/s network
Connection to a 10 Mbit/s network Network activity
No network connection
| Control button| | Restoring factory settings

Installing the set

Mounting the video encoder
The video encoder can be mounted on the wall or ceiling of the room using the supplied mounting bracket, screws and plugs.
Ensure that the mounting bracket engages correctly on the underside of the video encoder.
Mounting the door station and IP switching device
Mount the door station and IP switching device according to the operating instructions supplied with the products.
Connecting the set
The supplied circuit diagram shows how the devices in the set should be connected.
Door station: Disconnect the pre-wiring of the built-in loudspeaker (Va, Vb) in order to connect the passive video transceiver.

Configuring the video encoder with connected door station camera
The AXIS IP Utility software application enables you to locate and configure the video encoder in the network. The Axis IP Utility software is on the CD of the video encoder. -> www.axis.com = AXIS IP Utility
The following section assumes that a DHCP server in your network automatically allocates IP addresses. If you would like to allocate IP addresses manually in your network, refer to the video encoder manual for detailed information about this.

Launch the software:

  1. Selet a different language if necessarymerten MEG6910 0033 U Motion Door Station Set - 2

The video encoder is automatically displayed for you when the software starts.
Make a note of the IP address specified here, because you will need to know this IP address at another point.

  1. Double-click the video encoder icon. The start screen of the video encoder appears.merten MEG6910 0033 U Motion Door Station Set - 3 The Configure Root Password dialog box is displayed on the first time you access the start screen. Define the administrator password here.

  2. Enter the password, repeat the password and click the OK button.merten MEG6910 0033 U Motion Door Station Set - 4 A direct view of the camera picture is shown for you.

  3. Click Setup to call up the settings.merten MEG6910 0033 U Motion Door Station Set - 5

  4. Click 1 Users to set options for the password.

  5. Activate the Enable anonymous viewer login (no user name or password required) option.
    This activation is required for fault-free display in the
    U.motion touch panel.

  6. Save your settings (Save)
    You can exit the software application.

In the following steps, you reset all parameters (including the IP addresses) to the factory default settings.

  1. Disconnect the network cable from the video encoder.
  2. Press and hold the control button and reconnect the network cable.
  3. Press and hold the control button until the status LED lights up yellow.

The video encoder has been reset when the status LED lights up green. The process may take about 1 minute.
For further setting options, please refer to the operating instructions of the video encoder.

Configuring U.motion KNX Server Plus

In the U.motion Builder, you must:

  • configure the video encoder as a door station camera in the video monitoring function;
  • create the door station as a new intercom external unit;
  • link the door station to the camera.

Configuring the video encoder as a door station camera in the video monitoring function

  1. Open the U.motion Builder.
  2. Navigate to the video monitoring menu item.
  3. Create a new camera (+).
  4. Make the following settings on the configuration screen of the camera:
    – Specify the name of your camera (e.g. Door station)
    – Select Generic (JPEG) as the video format
    – Specify the IP address of the video encoder, followed by the following path:
    http://xxx.xxx.x.xxxJazis-cglipg/image.cgi
    – IP port: 80 – Protocol: IITTP
    – Maximum pictures per second: 5
    – JPG

merten MEG6910 0033 U Motion Door Station Set - 7

Creating the door station as an intercom external unit

  1. Navigate to the (External units) menu item.
  2. Create a new external unit (+).
  3. Enter the name of the door station, the VoIP number and the password.

Linking the door station to the door station camera

  1. Keep the configuration screen of the external unit open.

  2. Enter the name of the newly created camera in the search function (in this example: Door station).
    The camera is shown to you as the search result.

  3. Click and drag the search result to the linking area of the configuration screen for the external unit that is still open. The door station and door station camera are now linked.

Configuring the door station and IP switching device Using the IP Setup software, you can locate and configure IP door stations and IP switching devices in the network, for example, and define allocations (bell push-button <-> device).The IP Setup software is located on the CD supplied with the door station.

Install the software on your PC (following the instruc-tions from the installation wizard) and start the software.

  1. Create a new project.
  2. Determine the location of the integrated IP devices in the system.
  3. Select the door station.
  4. Click the TK-Anbindung tab.
  5. Under Registrar, enter the IP address of the U.motion KNX Server Plus and the SIP telephone number of the door station.
  6. Click Ruf Ober SIP Registrar anlegen to create an SIP entry (the device that you want to call).
  7. Click the Klingeltasten tab.
  8. Click Add to add the device that you want to call.
  9. Select the SIP call connection for the bell push-button and confirm with Ok.

merten MEG6910 0033 U Motion Door Station Set - 9

The various functions such as timer, break/ make contact and changeover functions of the IP switching device must also be configured. To do this, click the Schaltgerate folder to access the configuration.

merten MEG6910 0033 U Motion Door Station Set - 10 For more information about this, refer to the manual on the USB stick.

Technical data

Door station

Power supply: PoE class 0
Elements: Built-in loudspeaker, colour camera, 1 bell push-button

(MEG6910-0033), 2 bell push-button (MEG6910-0034)
Colour camera:| Mechanically adjustable
Total surveillance range:| 150° horizontal/90° vertical
Bell push-buttons:| Back-lit with white LEDs
Nameplates:| Illuminated; can be changed from the front with no additional tools
Faceplate dimensions:| 355 x 154 x 2.5 mm (HxWxD)
MEG6910-0033
MEG6910-0034:| 355 x 154 x 2.5 mm (HxWxD)
Flush-mounted box dimensions:
MEG6910-0033:| 331 x 130 x 52 mm (HxWxD)
MEG6910-0034| 361 x 130 x 52 mm (HxWxD)

IP Switching device

Power supply: AC 230 V
Output voltage for door opener: AC 9 V/600 mA
Switch contacts: 2
Switching current: 10 A ohmic load, 6 A inductive/capacitive load
Input: 1, for potential-free contacts for controlling the IP switching device
Dimensions: 90 x 90 x 50 mm (HxWxD)
Device width: 5 modules

Video encoder

Power supply: PoE class 2
Displays: 3 LEDs for power, status and network
Connections: RJ45 (PoE class 2), BNC
Operating elements: 75 ohm termination, control button (reset)
Max. cable length 250 m coaxial video cable
Dimensions: 30 x 37 x 101 mm (HxWxD)
Weight: 82 g

Dispose of the device separately from household waste at an official collection point. Professional recycling protects people and the environment against potential negative effects.

Schneider Electric GmbH c/o Merten
Gothaer Stral3e 29, 40880 Ratingen www.merten.de
www.merten-austria.at
Kundenbetreuung: Telephone: +49 2102-404 6000

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals