intel Cyclone 10 GX Device Errata User Guide
- June 3, 2024
- Intel
Table of Contents
intel Cyclone 10 GX Device Errata User Guide
Intel® Cyclone® 10 GX Device Errata
This errata sheet provides information about known device issues affecting Intel® Cyclone® 10 GX devices. The table below lists specific device issues and affected Intel Cyclone 10 GX devices.
Table 1. Device Issues
Issue | Affected Devices | Planned Fix |
---|---|---|
Automatic Lane Polarity Inversion for PCIe Hard IP on page 4 | All Intel | |
Cyclone 10 GX devices | No planned fix | |
High VCCBAT Current when VCC is Powered Down on page 5 | All Intel Cyclone 10 | |
GX devices | No planned fix |
Failure on Row Y59 When Using the Error Detection Cyclic Redundancy Check
(EDCRC) or Partial Reconfiguration (PR) on page 6| All Intel Cyclone 10 GX
devices| No planned fix
GPIO Output may not meet the On- Chip Series Termination (Rs OCT) without
Calibration Resistance Tolerance Specification or Current Strength Expectation
on page 7| All Intel Cyclone 10 GX devices| No planned fix
Automatic Lane Polarity Inversion for PCIe Hard IP
For Intel Cyclone 10 GX PCIe Hard IP open systems where you do not control both ends of the PCIe link, Intel does not guarantee automatic lane polarity inversion with the Gen1x1 configuration, Configuration via Protocol (CvP), or Autonomous Hard IP mode. The link may not train successfully, or it may train to a smaller width than expected. There is no planned workaround or fix.
For all other configurations, refer to the following workaround.
Workaround
Refer to the Knowledge Database in the related links below for details to workaround this issue.
Status
Affects: All Intel Cyclone 10 GX devices.
Status: No planned fix.
Related Information
Knowledge Database
High VCCBAT Current when VCC is Powered Down
If you power off VCC when VCCBAT remains powered on, VCCBAT may draw higher current than expected.
If you use the battery to maintain volatile security keys when the system is not powered up, VCCBAT current could be up to 120 µA, resulting in shortened battery life.
Workaround
Contact your battery provider to evaluate the impact to the retention period of the battery used on your board.
There is no impact if you connect the VCCBAT to the on-board power rail.
Status
Affects: All Intel Cyclone 10 GX devices
Status: No planned fix.
Failure on Row Y59 When Using the Error Detection Cyclic Redundancy Check (EDCRC) or Partial Reconfiguration (PR)
When the error detection cyclic redundancy check (EDCRC) or partial reconfiguration (PR) feature is enabled, you may encounter unexpected output from clocked components such as flip-flop or DSP or M20K or LUTRAM that are placed at row 59 in Intel Cyclone 10 GX devices.
This failure is sensitive to temperature and voltage.
Intel Quartus® Prime software version 18.1.1 and later displays the following error message:
- In Intel Quartus Prime Standard Edition:
- Info (20411): EDCRC usage detected. To ensure reliable operation of these features on the targeted device, certain device resources must be disabled.
- Error (20412): You must create a floorplan assignment to block out the device resources at row Y=59 and ensure reliable operation with EDCRC. Use the Logic Lock (Standard) Regions Window to create an empty reserved region with origin X0_Y59, height = 1 and width = <#>. Also, review any existing Logic Lock (Standard) regions that overlap that row and ensure if they account for the unused device resources.
- In Intel Quartus Prime Pro Edition:
- Info (20411): PR and/or EDCRC usage detected. To ensure reliable operation of these features on the targeted device, certain device resources must be disabled.
- Error (20412): You must create a floorplan assignment to block out the device resources at row Y59 and ensure reliable operation with PR and/or EDCRC.
Use the Logic Lock Regions Window to create an empty reserved region, or add set_instance_assignment -name EMPTY_PLACE_REGION “X0 Y59 X<#> Y59-R:C-empty_region” -to | directly to your Quartus Settings File (.qsf). Also, review any existing Logic Lock regions that overlap that row and ensure if they account for the unused device resources.
Note: Intel Quartus Prime software versions 18.1 and earlier do not report these errors.
Workaround
Apply the empty logic lock region instance in the Quartus Prime Settings File (.qsf) to avoid use of row Y59. For more information, refer to the corresponding knowledge base.
Status
Affects: All Intel Cyclone 10 GX devices
Status: No planned fix.
GPIO Output may not meet the On-Chip Series Termination (Rs OCT) without Calibration Resistance Tolerance Specification or Current Strength Expectation
Description
The GPIO pull-up impedance may not meet the on-chip series termination (Rs OCT) without calibration resistance tolerance specification mentioned in the Intel Cyclone 10 GX device datasheet. While using the current strength selection, the GPIO output buffer may not meet expected current strength at VOH voltage level when driving HIGH.
Workaround
Enable the on-chip series termination (Rs OCT) with calibration in your design.
Status
Affects: All Intel Cyclone 10 GX devices
Status: No planned fix.
Document Revision History for Intel Cyclone 10 GX Device Errata and
Design Guidelines
Document Version | Changes |
---|---|
2022.08.03 | Added a new erratum: GPIO Output may not meet the On-Chip Series |
Termination (Rs OCT) without Calibration Resistance Tolerance Specification or
Current Strength Expectation.
2020.01.10| Added a new erratum: Failure on Row Y59 When Using the Error
Detection Cyclic Redundancy Check (EDCRC) or Partial Reconfiguration (PR).
2017.11.06| Initial release.
Intel Corporation. All rights reserved. Intel, the Intel logo, and other Intel
marks are trademarks of Intel Corporation or its subsidiaries. Intel warrants
performance of its FPGA and semiconductor products to current specifications
in accordance with Intel’s standard warranty, but reserves the right to make
changes to any products and services at any time without notice. Intel assumes
no responsibility or liability arising out of the application or use of any
information, product, or service described herein except as expressly agreed
to in writing by Intel. Intel customers are advised to obtain the latest
version of device specifications before relying on any published information
and before placing orders for products or services.
Other names and brands may be claimed as the property of others.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>