Dear Customer,
by purchasing a SELVE electronic radio drive you have decided in favour of a quality product from the SELVE company. This instruction manual describes the installation and operation of the drive. Make sure to read this handbook before commissioning of the SELVE drive and adhere to the safety instructions.
After publication of the operating instructions, SELVE shall not be liable for any changes to norms and standards! Subject to change without prior notice!

Safety instructions

Safety instructions
Warning!

  • This drive must only be connected by authorised specialists. For installation and maintenance the system has to be de-ernergised.
  • Consider the following:
  • Relevant laws, standards and instructions
  • Country-specific terms
  • The specifications of the local energy providers and stipulations for damp rooms pursuant to VDE 0100
  • The safety instructions of DIN EN 60335
  • The state of the technology at the time of installation
  • This instruction manual and any operating instructions for connected com ponents
  • For the drive installation, a mains supply circuit break with at least 3 mm contact opening width per pole must be provided (DIN EN 60335). Safety measures against inadvertent activation must be in place.
  • Check the drive and the complete installation for damage. In case of damage to the drive, in particular to the connection line, it must not be taken into operation!
  • Keep children and non-authorized persons away from the installation. Also keep objects from the operating area. It must be possible to see the operation area during working process.
  • Control units must be installed at a height of more than 1.50 m. Movable parts of the drive must be installed at a height of more than 2.50 m above the ground or another surface that grants access to the drive. The minimum distance between moving parts and adjacent objects is 40 cm.
  • Outdoor or flush mounted, the motor connecting cable must be laid in a conduit.
  • Nominal torque and duration of activation must be aligned with the system requirements. Technical data such as nominal torque and duration of activation are written on the identification plate.
  • This instruction manual is part of the device and warranty conditions. It has to be handed out to the electrician and operator.
  • Damage due to wrong handling, wrong wiring, use of force, interference with the drive by a third party or subsequent changes to the installation and any consequential damage arising from this is not subject to the warranty.
  • Use only unchanged SELVE origi

Information about the drive features

2.1. Designated use
The drive types SE Plus-R, SEM Plus-R, SEL Plus-R and SES-R must only be used for operating roller shutters and sun-protection systems.
2.2. Drive type features

Motor type| SE Plus| SEM Plus| SEL Plus| SES
---|---|---|---|---
General features
Blockage detection downwards| X| X| X| X
Obstacle detection downwards| | | X| X
Reverse function: Relieving after running onto an obstacle downwards| | | X| X
Overload protection upwards if torque is too high, freezing protection| X| X| X| X
Automatic up and downwards direction detection| X| X| X| X
Parallel connection of several motors possible| X| X| X| X
End position setting
Switch-off bottom: fixed point| X| X| X| X
Switch-off top: fixed point| possible| | possible| possible
Switch-off top: limit switch and release| possible| possible| possible| possible
Switch-off top: limit switch without release| | possible| |
Automatic setting mode| | | X| X
Roller shutter installation
To be used with normal safety and fixing springs| X| | X|
To be used with security springs| possible| | possible| X
Intended use
Application in roller shutter systems| X| | X| X
Application in screens| X| | |
Application in awnings| possible| X| |

2.3. SELVE radio special features
All SELVE radio drives receive radio signals on 868.3 MHz radio frequency. All SELVE intronic transmitters can be taught into these drives. Up to 16 transmitters can be
taught into one motor. Please adhere to the transmitter operating instructions. The range of the radio controllers is restricted by legal provisions for radio sets and by structural conditions.
You should ensure that you have perfect radio reception during planning, particularly if the transmitter is in a different room than the radio drive.
Ensure that you do not install the controller in the immediate vicinity of metal surfaces.
Similarly, powerful local transmitting stations with an identical frequency may interfere with smooth operation of the system as well.

Installation and electrical connection

Warning!
Important!
Risk of injury through an electric shock! Connection only when de-energised! Run the drive only after installation.
3.1. Installation of the drive into a shaft

  1. Attach crown and coupling adapter to the motor and fasten them with the locking device.SELVE SE Plus R Electronic Radio Motors
  2. Push the drive into the shaft in a positive-locking way. The drive must not be subject to any impacts. Crown and coupling adapters must not have any play inside the shaft.
  3. Where required, secure the drive axially, e.g. by screwing the shaft to the coupling adapter. Do not drill holes into the drive area!SELVE SE Plus R Electronic Radio Motors - Fig
  4. Attach the shaft with the drive and the shaft cap in the bearings. Do not bend the motor cable and aerial and place them so that neither the aerial nor the motor cable cannot be damaged. Do not place the aerial parallel to the motor cable. The aerial must not be shortened or extended. To keep water from getting into the motor, place the motor line in a bend direction downwards, so that any water can drip off.
  5. Attach the curtain to the shaft.

3.2. Supporting the motors
In general, SELVE motors can be supported by means of an inserted square or by means of the external contour of the motor head. There are different motor brackets for all support options.

SELVE SE Plus R Electronic Radio Motors - Fig 1

Furthermore, different flanges or mounting plates can be pre-screwed. In case of square support, there must be a mechanical stop behind the motor bearing, in order to avoid axial movement of the square. Attention! The SEL 2/30 motor must not be supported by using the pluggable square 930285!
If the motor head is screwed directly to a head piece or if a flange is pre- screwed, it must be taken into consideration that the external screw holes (with a clearance of 48 mm) must be used for series 2 motors in any case!

The internal screw holes (clearance of 29 mm) are not able to transmit torques. As there is no thread within the external screw holes, special screws must be used.
For series 1, there are only 2 screw holes (clearance of 29 mm), which can be used.
Please use the following screw types:

  • Series 2 plastic: self-tapping screw KN 1033 STS 50×14-Z
  • Series 2 metal: self-tapping screw KN 3041 SLS L40x12 T20
  • SP series 1: self-tapping screw KN 1041 STS 40×12 T20
  • SE series 1: screw DIN 965 M5 x 10

3.3. Assembly and disassembly of the patch cord
The patch cord is not yet implemented for all motor types; some motor types are still supplied with a fixed power cord.
Warning!
Important!
Risk of injury through an electric shock!
When the patch cord is unplugged, the line must be de-energised!
For installing the patch cord, de-energise the patch cord first. Insert the plug into the motor head until the lock engages audibly.

SELVE SE Plus R Electronic Radio Motors - Fig 3

For uninstalling the patch cord, de-energise the patch cord first. Open the plug lock through the lateral opening at the motor head. This can be done with a screwdriver or a special release tool. Press on the locking clip from both sides and carefully pull out the patch cord until the plug comes loose and the patch cord can be removed.

SELVE SE Plus R Electronic Radio Motors - Fig 4

3.4. Electric connection
SELVE SE Plus R Electronic Radio Motors - Fig 5

  1. = PE, yellow-green
  2. = L1, brown
  3. = DOWN, black
  4. = UP, grey
  5. = N, blue

Connection of a permanently installed switch is optional. Connection via N, L1 and PE is  sufficientfor radio control only.

Setting of the end positions

4.1. Delivery status
In the SELVE delivery status no end positions or transmitters are learnt into the radio motor! In this state, the drive can be operated in deadman’s operation only. Safety
functions such as obstacle detection are deactivated at delivery and will only become active after both end positions are set.
State at delivery is indicated by a short movement when the radio drive is connected to power. The SEL Plus-R and SES-R drives are in automatic setup- mode.
4.2. Setup functions
The end positions setting of a SELVE radio drive is possible via:

  • any intronic transmitter
  • the setting switch for radio drives (item no. 290109)
  • any standard switch (in automatic mode), only SEL Plus-R and SES-R
    When connecting the setting switch for radio drives, consider the following:

Warning!
Important! Risk of injury through an electric shock!
Connection only when de-energised!
The 5 wires in the setting switch cable must be connected to the drive wiring cable according to their colours.

SELVE SE Plus R Electronic Radio Motors - Fig 6

UP = grey
DOWN = black
N = blue
L1 = brown
PE = yellow-green
4.3. Mechanic requirements
Operating of the SE Plus-R and SEL Plus-R drives is possible with normal safety and fixing springs. Optionally, security springs can also be used.
For operating the SES-R security springs must be used.
If the drive is supposed to move against the stop in the upper end position, a stable end stop must be installed!
If the drive is set in automatic setup-mode, a limit must be installed for the lower switchoff position (e.g. windowsill) for the shutter to run against.
4.4. Selection table for settings:

Setup-mode/end positions in operation| SE Plus| SEM Plus| SEL Plus| SES
---|---|---|---|---
4.4.1 Automatic setup-mode bottomposition,topstop/release| | | X
oA+uA| X
oA+uA
4.4.2 Manual setup-mode bottom position, top position| X
uP+oP| | X
uP+oP| X
uP+oP
4.4.3 Manual setup-mode bottom position, top stop/release| X
uP+oA| X
uP+oA| X
uP+oA| X
uP+oA
4.4.4 Manual setup-mode bottom position, top stop/no release| | X
uP+o5cm| |

The abbreviations for the settings types and order:
uA = move to stop at bottom
uP = store bottom position
oA = move against stop at top
oP = store top position
o5cm = store top positon 5 cm before stop
4.4.1. Automatic setup-mode for SEL Plus-R and SES-R
in operation: bottom position, top stop/release

When the movement is interrupted twice during operation, the system is in automatic setup-mode. Drive types SEL Plus-R and SES-R will automatically find their stop
positions. For this, a drive must first move against the upper stop and then downwards until it switches off automatically.
Important!
Only connect that radio drive to power that is to be programmed! You cannot program more than one drive at the same time.

SELVE SE Plus R Electronic Radio Motors - Fig 7

  1. Connect to power.
  2. For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
  3. Move the drive upwards with the UP or DOWN button. The correct rotation direction assignment will be performed at the end of the end position setting.
  4. The drive moves against the upper stop and stops automatically.
  5. Continue to keep the button pressed or press one of the motion buttons again. Now the drive automatically moves down wards.
  6. The drive will reach the lower limit and stop automatically.
  7. The end positions are now set and the rotation direction assignment is correct. Perform a test run.
  8. For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
  9. The transmitter is now permanently taught-in.

4.4.2. Manual setup-mode for SE Plus-R, SEL Plus-R and SES-R
in operation: bottom position, top position
When the movement is interrupted once, the system is in manual setup-mode. In manual setup-mode, the lower end position must be set and stored first. Afterwards, the upper end position can be set and stored.
Important!
Only connect that radio drive to power that is to be programmed! You cannot program more than one drive at the same time.

SELVE SE Plus R Electronic Radio Motors - Fig 8

  1. Connect to power.
  2. For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
  3. Only SEL Plus-R and SES-R: Press the STOP button on your transmitter or the E button of the setting cable for 6 se conds.
  4. Move the drive to the lower end position with the UP or DOWN button. Press the STOP or E button for 3 seconds The correct rotation direction assignment will be carried out at the end of the end po sition setting.
  5. Move the drive to the designated upper end position and press the STOP or E button for 3 seconds.
  6. The end positions are now set and the rotation direction assignment is correct. Perform a test run.
  7. For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
  8. The transmitter is now permanently taught-in.

4.4.3. Manual setup-mode for SE Plus-R, SEM Plus-R, SEL Plus-R and SES-R
in operation: bottom position, top stop/relief
When the movement is interrupted once, the system is in manual setup-mode.
In manual setup-mode, the lower end position must be set and stored first. Afterwards, the upper end position can be set and stored. Drive against the top stop until the drive
is automatically switched off.
Important!
Only connect that radio drive to power that is to be programmed! You cannot program more than one drive at the same time.

SELVE SE Plus R Electronic Radio Motors - Fig 9

  1. Connect to power.
  2. For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
  3. Only SEL Plus-R and SES-R: Press the STOP button on your transmitter or the E button of the setting cable for 6 se conds.
  4. Move the drive to the lower end position with the UP or DOWN button. Press the STOP or E button for 3 seconds The correct rotation direction assignment will be carried out at the end of the end po sition setting.
  5. Move the drive to the designated upper end position and press the STOP or E button for 3 seconds.
  6. The end positions are now set and the rotation direction assignment is correct. Perform a test run.
  7. For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
  8. The transmitter is now permanently taught-in.

4.4.4. Manual setup-mode for SEM Plus-R in operation: bottom position, top stop/no release
When the movement is interrupted once, the system is in manual setup-mode.
In manual setup-mode, the lower end position must be set and stored first. Afterwar the upper end position can be set and stored. A position 5 cm from the upper stop is to be selected and stored.
Important!
Only connect that radio drive to power that is to be programmed! You cannot program more than one drive at the same time.

SELVE SE PSELVE SE Plus R Electronic Radio Motors - Fig 9lus R Electronic
Radio Motors - Fig 10

  1. Connect to power.
  2. For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
  3. Move the drive to the lower end position with the UP or DOWN button. Press the STOP or E button for 3 seconds The correct rotation direction assignment will be carried out at the end of the end po sition setting.
  4. Move to a position about 5 cm below the upper end stop and press the STOP or E button for 3 seconds. The drive moves against the upper stop with increased sensitivity from this position and stops automatically.
  5. The end positions are now set and the rotation direction assignment is correct. Perform a test run.
  6. For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
  7. The transmitter is now permanently taught-in.

Teaching in/deleting of other transmitters/channels

5.1. Programming further transmitters/channels
Press the PROG button of a programmed transmitter/channel for 3 seconds (wait for confirmation run from the drive). The receiver is now in programme mode for
1 minute. Press (1 sec.) the PROG button of the new transmitter/channel. The new transmitter/channel has now been programmed.

SELVE SE Plus R Electronic Radio Motors - Fig 11

5.2. Deleting of transmitters/channels
Press the PROG button of a programmed transmitter/channel for 3 seconds (wait for confirmation run from the drive). The receiver is now in programme mode for 1 minute. Press (1 sec.) the PROG button of the transmitter/channel you wish to delete.
The transmitter/channel has now been deleted.

SELVE SE Plus R Electronic Radio Motors - Fig 12

Set intermediate position

The intermediate position is an arbitrary position of the roller shutter between the upper and lower end.
Set intermediate position 1

SELVE SE Plus R Electronic Radio Motors - Fig 13

Set intermediate position 2

SELVE SE Plus R Electronic Radio Motors - Fig 14

Adjusting the end position with the setting switch

Connect the SELVE setting switch for radio drives (item no. 290109) to the connection lines according to colour.
Warning!
If the setting cable is plugged in, the wires are power supplied. For connecting of the setting switch to the drive de-energise the cable. Press the E button for 6 seconds to switch the drive into manual setupmode.
Then set the end positions as described in the grey sections for items 4.4.2 to 4.4.4. It remains in setting mode until the lower and upper end limits are being pro grammed. If the radio motor is already in setting mode and the setting button is pressed for 6 seconds instead of 3 seconds, an end position is programmed anyhow.

Functions in service mode (setting by using a transmitter)

In order to carry out the following settings, the drive has to be put into service mode by disconnecting it from the mains supply in a special way.
Consider the following:

  • Transmitter programmation has to be finished before service mode can be executed.
  • Put only the drive which is to be set into service mode.
  • The drive remains in service mode for 4 minutes.
  • In order to leave the service mode just drive the motor up or down.

Fuse/Hirschmann plugSELVE SE Plus R Electronic Radio Motors - Fig
15

The drive confirms the service mode by a brief up and down moving.
8.1. Adjusting the end limits by using the transmitter
Setup-mode can only be finished by programming both end positions. The transmitter assignment is not affected by this. When setting the end positions, the drive is in the normal operating state again.
Put the drive into service mode by disconnecting it. Press the STOP button of an assigned transmitter for 6 seconds to return the drive to setting mode (wait until the transmitter indicator flashes twice). Then set the end positions as described in the grey sections for items 4.4.2 to 4.4.4.

SELVE SE Plus R Electronic Radio Motors - Fig 16

Set the end positions as described in the grey sections for items 4.4.2 to 4.4.4.
8.2. Reprogramming if a transmitter is damaged or lost
Only use if a programmed transmitter is no longer available (damaged or lost)! In order to program a new transmitter/channel, the receiver has to be put into eprogramming  ode by disconnecting it  rom the mains supply.
Subsequently press the PROG button of the new transmitter for 3 sec. All the old transmitters/channels have been depro grammed.

SELVE SE Plus R Electronic Radio Motors - Fig 17

8.3. Resetting to the delivery status
In the state of delivery, no end positions and no transmitters are taught in the drive!
To return the drive to the state at delivery, the drive must be brought into service mode by disconnecting it. Then press the PROG button of an assigned transmitter for9 seconds.

SELVE SE Plus R Electronic Radio Motors - Fig 18

8 .4. Group separation
A group is an assembly of several drives/receivers that can be controlled by one transmitter/channel.
This transmitter is deleted after the end of the group separation. During group separation, each drive/receiver will only once move randomly for 3 seconds within a period of time of approx. 2 minutes. Stopping the drive with any transmitter will teach this transmitter into the respective drive.
First press the STOP button and then the UP and DOWN buttons as well. Keep all three buttons depressed for 9 seconds, in order to start the group separation (wait until the transmitter control light flashes three times). The drive indicates activation of group separation by a short run. Then each drive will move randomly for 3 seconds within a period of about 2 minutes. Within the 3-second time slot, stop the movement of the motor using the STOP button on the transmitter to be programmed. Then the transmitter is taught in, and the drive has left the group separation mode.

Every drive moves randomly only for 3 seconds within about 2 minutes. The drive in question must be stopped by the selected trans mitter during the movement.

SELVE SE Plus R Electronic Radio Motors - Fig 20

If the drives are still moving together, repeat the procedure for the drives affected.
If you did not teach in a transmitter through the STOP button and no other transmitter is taught in, you may teach in this transmitter again by pressing the UP and DOWN buttons at the same time and then pressing the PROG button.

Technical data

Series| Torque| Rotation speed| powerInput| Output
---|---|---|---|---
1/6| 6 Nm| 15 Rpm| 0.45 A| 105 W
1/10| 10 Nm| 15 Rpm| 0.45 A| 105 W
2/7| 7 Nm| 17 Rpm| 0.41 A| 95 W
2/10| 10 Nm| 17 Rpm| 0.45 A| 105 W
2/15| 15 Nm| 17 Rpm| 0.66 A| 152 W
2/20| 20 Nm| 17 Rpm| 0.75 A| 172 W
2/30| 30 Nm| 17 Rpm| 0.95 A| 220 W
2/40| 40 Nm| 17 Rpm| 1.50 A| 345 W
2/50| 50 Nm| 12 Rpm| 1.50 A| 345 W
3/50| 50 Nm| 17 Rpm| 1.40 A| 315 W
3/60| 60 Nm| 12 Rpm| 1.10 A| 245 W
3/70| 70 Nm| 17 Rpm| 1.90 A| 435 W
3/80| 80 Nm| 12 Rpm| 1.40 A| 322 W
3/120| 120 Nm| 11 Rpm| 1.90 A| 435 W

Not all drive types are available in all series and torques. The motors have a 3 m power line by default.
Information for all drive types:

Nominal voltage: 230 V AC/50 Hz
Safety class: IP 44
Operating time: 4 min.
Radio frequency: 868.3 MHz

The maximum radio range is up to 25 m indoors and up to 350 m in the open field.
Subject to change without prior notice!

General declaration of conformity

SELVE GmbH & CO. KG company, hereby declares that the SE/SEM/SEL Plus-R and SES-R are in conformity with the basic requirements and other relevant provisions of the Directive 73/23/EWG and 89/336/EWG. The declaration of conformity can be looked up at www.selve.de.

Troubleshooting

Problem Cause Solution
Radio drive does not work Electric connection defective Check the connection
No transmitters taught in Teach in transmitter
Transmitter out of range or batteries discharged Bring transmitter into range

or insert new batteries
Teach in new transmitter
Thermal protection switch has triggered| Wait for 5 to 20 minutes
Radio drive does not perform a short drive at initial commissioning| Electric connection defective| Check the connection
End positions are already set| Teach in transmitter, then reset radio drive to state at delivery
End positions are already set in the radio drive and a transmitter is taught in| Check the connection
Teach in new hand transmitter, then reset radio drive to state at delivery
UP and DOWN directions are switched| End positions set incorrectly| Reset end positions
Radio drive has stopped auto- matically when moving DOWN| Blockage/obstacle recognition has triggered| Remove obstacle, check curtain run
Radio drive has stopped auto- matically when moving UP| Overload recognition has triggered| Remove obstacle, check curtain path, possibly select stronger drive

SELVE GmbH & Co. KG
Werdohler Landstraße 286
D-58513 Lüdenscheid
Tel.: +49 2351 925-0
Fax: +49 2351 925-111
Internet: www.selve.de
E-Mail: info@selve.de

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals