- Safety instructions
- Information about the drive features
- Installation and electrical connection
- Setting of the end positions
- Teaching in/deleting of other transmitters/channels
- Set intermediate position
- Adjusting the end position with the setting switch
- Functions in service mode (setting by using a transmitter)
- Technical data
- General declaration of conformity
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SELVE-Electronic-Radio-motors
Instruction Manual
SE Plus-R Electronic Radio Motors
Please keep these instructions in a safe place!
Product discontinued, not available anymore.
Dear Customer,
by purchasing a SELVE electronic radio drive you have decided in favour of a
quality product from the SELVE company. This instruction manual describes the
installation and operation of the drive. Make sure to read this handbook
before commissioning of the SELVE drive and adhere to the safety instructions.
After publication of the operating instructions, SELVE shall not be liable for
any changes to norms and standards! Subject to change without prior notice!
Safety instructions
Safety instructions
Warning!
- This drive must only be connected by authorised specialists. For installation and maintenance the system has to be de-ernergised.
- Consider the following:
- Relevant laws, standards and instructions
- Country-specific terms
- The specifications of the local energy providers and stipulations for damp rooms pursuant to VDE 0100
- The safety instructions of DIN EN 60335
- The state of the technology at the time of installation
- This instruction manual and any operating instructions for connected com ponents
- For the drive installation, a mains supply circuit break with at least 3 mm contact opening width per pole must be provided (DIN EN 60335). Safety measures against inadvertent activation must be in place.
- Check the drive and the complete installation for damage. In case of damage to the drive, in particular to the connection line, it must not be taken into operation!
- Keep children and non-authorized persons away from the installation. Also keep objects from the operating area. It must be possible to see the operation area during working process.
- Control units must be installed at a height of more than 1.50 m. Movable parts of the drive must be installed at a height of more than 2.50 m above the ground or another surface that grants access to the drive. The minimum distance between moving parts and adjacent objects is 40 cm.
- Outdoor or flush mounted, the motor connecting cable must be laid in a conduit.
- Nominal torque and duration of activation must be aligned with the system requirements. Technical data such as nominal torque and duration of activation are written on the identification plate.
- This instruction manual is part of the device and warranty conditions. It has to be handed out to the electrician and operator.
- Damage due to wrong handling, wrong wiring, use of force, interference with the drive by a third party or subsequent changes to the installation and any consequential damage arising from this is not subject to the warranty.
- Use only unchanged SELVE origi
Information about the drive features
2.1. Designated use
The drive types SE Plus-R, SEM Plus-R, SEL Plus-R and SES-R must only be used
for operating roller shutters and sun-protection systems.
2.2. Drive type features
Motor type| SE Plus| SEM Plus| SEL Plus|
SES
---|---|---|---|---
General features
Blockage detection downwards| X| X| X| X
Obstacle detection downwards| | | X| X
Reverse function: Relieving after running onto an obstacle downwards| | | X| X
Overload protection upwards if torque is too high, freezing protection| X| X|
X| X
Automatic up and downwards direction detection| X| X| X| X
Parallel connection of several motors possible| X| X| X| X
End position setting
Switch-off bottom: fixed point| X| X| X| X
Switch-off top: fixed point| possible| | possible| possible
Switch-off top: limit switch and release| possible| possible| possible|
possible
Switch-off top: limit switch without release| | possible| |
Automatic setting mode| | | X| X
Roller shutter installation
To be used with normal safety and fixing springs| X| | X|
To be used with security springs| possible| | possible| X
Intended use
Application in roller shutter systems| X| | X| X
Application in screens| X| | |
Application in awnings| possible| X| |
2.3. SELVE radio special features
All SELVE radio drives receive radio signals on 868.3 MHz radio frequency. All
SELVE intronic transmitters can be taught into these drives. Up to 16
transmitters can be
taught into one motor. Please adhere to the transmitter operating
instructions. The range of the radio controllers is restricted by legal
provisions for radio sets and by structural conditions.
You should ensure that you have perfect radio reception during planning,
particularly if the transmitter is in a different room than the radio drive.
Ensure that you do not install the controller in the immediate vicinity of
metal surfaces.
Similarly, powerful local transmitting stations with an identical frequency
may interfere with smooth operation of the system as well.
Installation and electrical connection
Warning!
Important! Risk of injury through an electric shock! Connection only when
de-energised! Run the drive only after installation.
3.1. Installation of the drive into a shaft
- Attach crown and coupling adapter to the motor and fasten them with the locking device.
- Push the drive into the shaft in a positive-locking way. The drive must not be subject to any impacts. Crown and coupling adapters must not have any play inside the shaft.
- Where required, secure the drive axially, e.g. by screwing the shaft to the coupling adapter. Do not drill holes into the drive area!
- Attach the shaft with the drive and the shaft cap in the bearings. Do not bend the motor cable and aerial and place them so that neither the aerial nor the motor cable cannot be damaged. Do not place the aerial parallel to the motor cable. The aerial must not be shortened or extended. To keep water from getting into the motor, place the motor line in a bend direction downwards, so that any water can drip off.
- Attach the curtain to the shaft.
3.2. Supporting the motors
In general, SELVE motors can be supported by means of an inserted square or by
means of the external contour of the motor head. There are different motor
brackets for all support options.
Furthermore, different flanges or mounting plates can be pre-screwed. In case
of square support, there must be a mechanical stop behind the motor bearing,
in order to avoid axial movement of the square. Attention! The SEL 2/30 motor
must not be supported by using the pluggable square 930285!
If the motor head is screwed directly to a head piece or if a flange is pre-
screwed, it must be taken into consideration that the external screw holes
(with a clearance of 48 mm) must be used for series 2 motors in any case!
The internal screw holes (clearance of 29 mm) are not able to transmit
torques. As there is no thread within the external screw holes, special screws
must be used.
For series 1, there are only 2 screw holes (clearance of 29 mm), which can be
used.
Please use the following screw types:
- Series 2 plastic: self-tapping screw KN 1033 STS 50×14-Z
- Series 2 metal: self-tapping screw KN 3041 SLS L40x12 T20
- SP series 1: self-tapping screw KN 1041 STS 40×12 T20
- SE series 1: screw DIN 965 M5 x 10
3.3. Assembly and disassembly of the patch cord
The patch cord is not yet implemented for all motor types; some motor types
are still supplied with a fixed power cord.
Warning!
Important! Risk of injury through an electric shock!
When the patch cord is unplugged, the line must be de-energised!
For installing the patch cord, de-energise the patch cord first. Insert the
plug into the motor head until the lock engages audibly.
For uninstalling the patch cord, de-energise the patch cord first. Open the plug lock through the lateral opening at the motor head. This can be done with a screwdriver or a special release tool. Press on the locking clip from both sides and carefully pull out the patch cord until the plug comes loose and the patch cord can be removed.
3.4. Electric connection
- = PE, yellow-green
- = L1, brown
- = DOWN, black
- = UP, grey
- = N, blue
Connection of a permanently installed switch is optional. Connection via N, L1 and PE is sufficientfor radio control only.
Setting of the end positions
4.1. Delivery status
In the SELVE delivery status no end positions or transmitters are learnt into
the radio motor! In this state, the drive can be operated in deadman’s
operation only. Safety
functions such as obstacle detection are deactivated at delivery and will only
become active after both end positions are set.
State at delivery is indicated by a short movement when the radio drive is
connected to power. The SEL Plus-R and SES-R drives are in automatic setup-
mode.
4.2. Setup functions
The end positions setting of a SELVE radio drive is possible via:
- any intronic transmitter
- the setting switch for radio drives (item no. 290109)
- any standard switch (in automatic mode), only SEL Plus-R and SES-R
When connecting the setting switch for radio drives, consider the following:
Warning!
Important! Risk of injury through an electric shock!
Connection only when de-energised!
The 5 wires in the setting switch cable must be connected to the drive wiring
cable according to their colours.
UP = grey
DOWN = black
N = blue
L1 = brown
PE = yellow-green
4.3. Mechanic requirements
Operating of the SE Plus-R and SEL Plus-R drives is possible with normal
safety and fixing springs. Optionally, security springs can also be used.
For operating the SES-R security springs must be used.
If the drive is supposed to move against the stop in the upper end position, a
stable end stop must be installed!
If the drive is set in automatic setup-mode, a limit must be installed for the
lower switchoff position (e.g. windowsill) for the shutter to run against.
4.4. Selection table for settings:
Setup-mode/end positions in operation| SE Plus| SEM Plus|
SEL Plus| SES
---|---|---|---|---
4.4.1 Automatic setup-mode bottomposition,topstop/release| | | X
oA+uA| X
oA+uA
4.4.2 Manual setup-mode bottom position, top position| X
uP+oP| | X
uP+oP| X
uP+oP
4.4.3 Manual setup-mode bottom position, top stop/release| X
uP+oA| X
uP+oA| X
uP+oA| X
uP+oA
4.4.4 Manual setup-mode bottom position, top stop/no release| | X
uP+o5cm| |
The abbreviations for the settings types and order:
uA = move to stop at bottom
uP = store bottom position
oA = move against stop at top
oP = store top position
o5cm = store top positon 5 cm before stop
4.4.1. Automatic setup-mode for SEL Plus-R and SES-R
in operation: bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in
automatic setup-mode. Drive types SEL Plus-R and SES-R will automatically find
their stop
positions. For this, a drive must first move against the upper stop and then
downwards until it switches off automatically.
Important!
Only connect that radio drive to power that is to be programmed! You cannot
program more than one drive at the same time.
- Connect to power.
- For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
- Move the drive upwards with the UP or DOWN button. The correct rotation direction assignment will be performed at the end of the end position setting.
- The drive moves against the upper stop and stops automatically.
- Continue to keep the button pressed or press one of the motion buttons again. Now the drive automatically moves down wards.
- The drive will reach the lower limit and stop automatically.
- The end positions are now set and the rotation direction assignment is correct. Perform a test run.
- For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
- The transmitter is now permanently taught-in.
4.4.2. Manual setup-mode for SE Plus-R, SEL Plus-R and SES-R
in operation: bottom position, top position
When the movement is interrupted once, the system is in manual setup-mode. In
manual setup-mode, the lower end position must be set and stored first.
Afterwards, the upper end position can be set and stored.
Important!
Only connect that radio drive to power that is to be programmed! You cannot
program more than one drive at the same time.
- Connect to power.
- For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
- Only SEL Plus-R and SES-R: Press the STOP button on your transmitter or the E button of the setting cable for 6 se conds.
- Move the drive to the lower end position with the UP or DOWN button. Press the STOP or E button for 3 seconds The correct rotation direction assignment will be carried out at the end of the end po sition setting.
- Move the drive to the designated upper end position and press the STOP or E button for 3 seconds.
- The end positions are now set and the rotation direction assignment is correct. Perform a test run.
- For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
- The transmitter is now permanently taught-in.
4.4.3. Manual setup-mode for SE Plus-R, SEM Plus-R, SEL Plus-R and SES-R
in operation: bottom position, top stop/relief
When the movement is interrupted once, the system is in manual setup-mode.
In manual setup-mode, the lower end position must be set and stored first.
Afterwards, the upper end position can be set and stored. Drive against the
top stop until the drive
is automatically switched off.
Important!
Only connect that radio drive to power that is to be programmed! You cannot
program more than one drive at the same time.
- Connect to power.
- For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
- Only SEL Plus-R and SES-R: Press the STOP button on your transmitter or the E button of the setting cable for 6 se conds.
- Move the drive to the lower end position with the UP or DOWN button. Press the STOP or E button for 3 seconds The correct rotation direction assignment will be carried out at the end of the end po sition setting.
- Move the drive to the designated upper end position and press the STOP or E button for 3 seconds.
- The end positions are now set and the rotation direction assignment is correct. Perform a test run.
- For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
- The transmitter is now permanently taught-in.
4.4.4. Manual setup-mode for SEM Plus-R in operation: bottom position,
top stop/no release
When the movement is interrupted once, the system is in manual setup-mode.
In manual setup-mode, the lower end position must be set and stored first.
Afterwar the upper end position can be set and stored. A position 5 cm from
the upper stop is to be selected and stored.
Important!
Only connect that radio drive to power that is to be programmed! You cannot
program more than one drive at the same time.
- Connect to power.
- For setting with transmitter: press the UP and DOWN buttons at the transmitter at the same time. The transmitter is temporarily taught into the drive.
- Move the drive to the lower end position with the UP or DOWN button. Press the STOP or E button for 3 seconds The correct rotation direction assignment will be carried out at the end of the end po sition setting.
- Move to a position about 5 cm below the upper end stop and press the STOP or E button for 3 seconds. The drive moves against the upper stop with increased sensitivity from this position and stops automatically.
- The end positions are now set and the rotation direction assignment is correct. Perform a test run.
- For setting with transmitter: press the PROG button at the transmitter. When setting with setting cable: press the UP and DOWN buttons on the transmitter at the same time, and then the PROG button.
- The transmitter is now permanently taught-in.
Teaching in/deleting of other transmitters/channels
5.1. Programming further transmitters/channels
Press the PROG button of a programmed transmitter/channel for 3 seconds (wait
for confirmation run from the drive). The receiver is now in programme mode
for
1 minute. Press (1 sec.) the PROG button of the new transmitter/channel. The
new transmitter/channel has now been programmed.
5.2. Deleting of transmitters/channels
Press the PROG button of a programmed transmitter/channel for 3 seconds (wait
for confirmation run from the drive). The receiver is now in programme mode
for 1 minute. Press (1 sec.) the PROG button of the transmitter/channel you
wish to delete.
The transmitter/channel has now been deleted.
Set intermediate position
The intermediate position is an arbitrary position of the roller shutter
between the upper and lower end.
Set intermediate position 1
Set intermediate position 2
Adjusting the end position with the setting switch
Connect the SELVE setting switch for radio drives (item no. 290109) to the
connection lines according to colour.
Warning!
If the setting cable is plugged in, the wires are power supplied. For
connecting of the setting switch to the drive de-energise the cable. Press the
E button for 6 seconds to switch the drive into manual setupmode.
Then set the end positions as described in the grey sections for items 4.4.2
to 4.4.4. It remains in setting mode until the lower and upper end limits are
being pro grammed. If the radio motor is already in setting mode and the
setting button is pressed for 6 seconds instead of 3 seconds, an end position
is programmed anyhow.
Functions in service mode (setting by using a transmitter)
In order to carry out the following settings, the drive has to be put into
service mode by disconnecting it from the mains supply in a special way.
Consider the following:
- Transmitter programmation has to be finished before service mode can be executed.
- Put only the drive which is to be set into service mode.
- The drive remains in service mode for 4 minutes.
- In order to leave the service mode just drive the motor up or down.
Fuse/Hirschmann plug
The drive confirms the service mode by a brief up and down moving.
8.1. Adjusting the end limits by using the transmitter
Setup-mode can only be finished by programming both end positions. The
transmitter assignment is not affected by this. When setting the end
positions, the drive is in the normal operating state again.
Put the drive into service mode by disconnecting it. Press the STOP button of
an assigned transmitter for 6 seconds to return the drive to setting mode
(wait until the transmitter indicator flashes twice). Then set the end
positions as described in the grey sections for items 4.4.2 to 4.4.4.
Set the end positions as described in the grey sections for items 4.4.2 to
4.4.4.
8.2. Reprogramming if a transmitter is damaged or lost
Only use if a programmed transmitter is no longer available (damaged or lost)!
In order to program a new transmitter/channel, the receiver has to be put into
eprogramming ode by disconnecting it rom the mains supply.
Subsequently press the PROG button of the new transmitter for 3 sec. All the
old transmitters/channels have been depro grammed.
8.3. Resetting to the delivery status
In the state of delivery, no end positions and no transmitters are taught in
the drive!
To return the drive to the state at delivery, the drive must be brought into
service mode by disconnecting it. Then press the PROG button of an assigned
transmitter for9 seconds.
8 .4. Group separation
A group is an assembly of several drives/receivers that can be controlled by
one transmitter/channel.
This transmitter is deleted after the end of the group separation. During
group separation, each drive/receiver will only once move randomly for 3
seconds within a period of time of approx. 2 minutes. Stopping the drive with
any transmitter will teach this transmitter into the respective drive.
First press the STOP button and then the UP and DOWN buttons as well. Keep all
three buttons depressed for 9 seconds, in order to start the group separation
(wait until the transmitter control light flashes three times). The drive
indicates activation of group separation by a short run. Then each drive will
move randomly for 3 seconds within a period of about 2 minutes. Within the
3-second time slot, stop the movement of the motor using the STOP button on
the transmitter to be programmed. Then the transmitter is taught in, and the
drive has left the group separation mode.
Every drive moves randomly only for 3 seconds within about 2 minutes. The drive in question must be stopped by the selected trans mitter during the movement.
If the drives are still moving together, repeat the procedure for the drives
affected.
If you did not teach in a transmitter through the STOP button and no other
transmitter is taught in, you may teach in this transmitter again by pressing
the UP and DOWN buttons at the same time and then pressing the PROG button.
Technical data
Series| Torque| Rotation speed| powerInput|
Output
---|---|---|---|---
1/6| 6 Nm| 15 Rpm| 0.45 A| 105 W
1/10| 10 Nm| 15 Rpm| 0.45 A| 105 W
2/7| 7 Nm| 17 Rpm| 0.41 A| 95 W
2/10| 10 Nm| 17 Rpm| 0.45 A| 105 W
2/15| 15 Nm| 17 Rpm| 0.66 A| 152 W
2/20| 20 Nm| 17 Rpm| 0.75 A| 172 W
2/30| 30 Nm| 17 Rpm| 0.95 A| 220 W
2/40| 40 Nm| 17 Rpm| 1.50 A| 345 W
2/50| 50 Nm| 12 Rpm| 1.50 A| 345 W
3/50| 50 Nm| 17 Rpm| 1.40 A| 315 W
3/60| 60 Nm| 12 Rpm| 1.10 A| 245 W
3/70| 70 Nm| 17 Rpm| 1.90 A| 435 W
3/80| 80 Nm| 12 Rpm| 1.40 A| 322 W
3/120| 120 Nm| 11 Rpm| 1.90 A| 435 W
Not all drive types are available in all series and torques. The motors have a
3 m power line by default.
Information for all drive types:
Nominal voltage: | 230 V AC/50 Hz |
---|---|
Safety class: | IP 44 |
Operating time: | 4 min. |
Radio frequency: | 868.3 MHz |
The maximum radio range is up to 25 m indoors and up to 350 m in the open
field.
Subject to change without prior notice!
General declaration of conformity
SELVE GmbH & CO. KG company, hereby declares that the SE/SEM/SEL Plus-R and SES-R are in conformity with the basic requirements and other relevant provisions of the Directive 73/23/EWG and 89/336/EWG. The declaration of conformity can be looked up at www.selve.de.
Troubleshooting
Problem | Cause | Solution |
---|---|---|
Radio drive does not work | Electric connection defective | Check the connection |
No transmitters taught in | Teach in transmitter | |
Transmitter out of range or batteries discharged | Bring transmitter into range |
or insert new batteries
Teach in new transmitter
Thermal protection switch has triggered| Wait for 5 to 20 minutes
Radio drive does not perform a short drive at initial commissioning| Electric
connection defective| Check the connection
End positions are already set| Teach in transmitter, then reset radio drive to
state at delivery
End positions are already set in the radio drive and a transmitter is taught
in| Check the connection
Teach in new hand transmitter, then reset radio drive to state at delivery
UP and DOWN directions are switched| End positions set incorrectly| Reset end
positions
Radio drive has stopped auto- matically when moving DOWN| Blockage/obstacle
recognition has triggered| Remove obstacle, check curtain run
Radio drive has stopped auto- matically when moving UP| Overload recognition
has triggered| Remove obstacle, check curtain path, possibly select stronger
drive
SELVE GmbH & Co. KG
Werdohler Landstraße 286
D-58513 Lüdenscheid
Tel.: +49 2351 925-0
Fax: +49 2351 925-111
Internet: www.selve.de
E-Mail: info@selve.de