Altronix OLS180220 Off-Line Power Supply Installation Guide

June 4, 2024
Altronix

OLS180220 Off-Line Power Supply
Installation Guide

Overview

Altronix OLS180220 power supply/charger converts 220VAC (working range 198VAC- 256VAC), 50/60Hz input into a 12VDC or 24VDC at 6A of continuous supply current  (see specifications). This general-purpose power supply has a wide range of applications for access control and security system accessories that require additional power.

Specifications

Input:

  • 220VAC (working range 198VAC-256VAC), 50/60Hz,0.8A.

Output:

  • 12VDC or 24VDC selectable output.
  • 6A continuous supply current.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Battery Backup:

  • Built-in charger for sealed lead acid or gel-type batteries.
  • Automatic switch over to stand-by battery when AC fails.
  • Maximum charge current 0.7A.

Supervision:

  • AC fail supervision (form “C” contacts).
  • Low battery supervision (form “C” contacts).

Visual Indicators:

  • AC input and DC output LED indicators.

Features:

  • Power ON/OFF switch.
  • Includes battery leads.

Board Dimensions (L x W x H approx.): 7.25” x 4.5” x 1.75” (184.1mm x 114.3mm x 44.5mm).
Voltage Output Selection Table:

Output VDC Switch Position Max. Load DC
1 2VDC SW1 – ON 6A
24VDC SW1 – OFF 6A

Installation Instructions:

OLS180220 should be installed in accordance with The National Electrical Code and all applicable Local Regulations.

  1. Mount the OLS180220 in the desired location/enclosure (mounting hardware included).

  2. Slide [Power ON/OFF] switch to OFF position.

  3. Set the OLS180220 to the desired DC output voltage via SW1 (Voltage Output Selection Table).
    Keep power-limited wiring separate from non-power-limited wiring (220VAC 50/60Hz Input, Battery Wires). Minimum 0.25” spacing must be provided.
    CAUTION: Do not touch exposed metal parts.
    Shut branch circuit power before installing or servicing equipment.
    There are no user-serviceable parts inside.
    Refer installation and servicing to qualified service personnel.

  4. Connect AC power to the terminals marked [L & N], and connect ground to the terminal marked [G].
    Use 18 AWG or larger for all power connections (Battery, DC output).
    Use 22 AWG to 18 AWG for power-limited circuits (AC Fail/Low Battery reporting).

  5. Measure output voltage before connecting devices. This helps avoid potential damage.

  6. Connect devices to be powered to the terminals marked [– DC +].

  7. When the use of stand-by batteries is desired, they must be lead acid or gel type.
    Connect the battery to the terminals marked [– BAT +] (battery leads included).
    Use two (2) 12VDC batteries connected in series for 24VDC operation.
    Note: When batteries are not used, a loss of AC will result in the loss of output voltage.

  8. Connect appropriate signaling notification devices to AC Fail and Low Battery supervisory relay outputs marked [NC, C, NO].

  9. Slide [Power ON/OFF] switch to ON position.

LED Diagnostics

Red (DC) Green (AC) Power Supply Status
ON ON Normal operating condition.
ON OFF Loss of AC. Stand-by battery is supplying power.
OFF ON No DC output. Short circuit or thermal overload condition.
OFF OFF No DC output. Loss of AC. Discharged or no battery present.

Terminal Identification

Terminal Legend Function/Description
L, G, N Connect 220VAC to these terminals: L to Hot, N to Neutral, G to

ground.
— DC +| 12VDC / 24VDC @ 6A continuous supply current.
AC FAIL
NC, C, NO| Used to notify loss of AC power, e.g. connect to audible device or alarm panel.
Relay is normally energized when AC power is present. Contact rating 1A @ 28VDC
Low Battery
NC, C, NO| Used to indicate low battery condition, e.g. connect to the alarm panel.
Relay is normally energized when DC power is present. Contact rating 1A @ 28VDC.
Low battery threshold:
12VDC output threshold set @ approximately 10.5VDC.
24VDC output threshold set @ approximately 21 VDC.
— BAT +| Stand-by battery connections. Maximum charge rate 0.7A.

Altronix OLS180220 Off-Line Power Supply

Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty
IIOLS180220 – Rev. 010704