BROMIC 4500W Platinum Smart-Heat Electric Heater Series II Instruction Manual

June 3, 2024
Bromic

BROMIC 4500W Platinum Smart-Heat Electric Heater Series II

BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-
PRO

IMPORTANT

  • READ THIS MANUAL CAREFULLY before installing or servicing this product.
  • Improper installation, operation, or maintenance can result in death, severe injury, or property damage.
  • This appliance is intended for fixed installation with voltage as specified on the power rating label.
  • Installation MUST be carried out by a licensed and authorised technician in accordance with local electrical codes
  • The Platinum Smart-Heat™ Electric Heater is intended for domestic and commercial use, unless otherwise specified
  • The marine grade variants shall be installed for land and The marine grade variants shall be installed for land and coastal environment application ONLY. oastal environment application ONLY.
  • The marine grade heater shall NOT be installed on marine he marine grade heater shall NOT be installed on marine crafts.
  • Australian Registered Design 366537. International Registered Designs Pending.

IMPORTANT NOTES AND WARNINGS

WARNING

  • IMPORTANT – Installation MUST be carried out by a licensed and authorised person.
  • DO NOT leave heaters ON unattended for prolonged use and inspect the heating space regularly.
  • Improper installation, adjustment, or alteration and failure to follow the warnings and instructions in this manual could result in severe personal injury, death or property damage.
  • The manufacturer is not responsible for any damage that could happen from improper use. The manufacturer emphasises that this appliance should be used in a responsible manner and that all procedures, warnings, and safety instructions contained in this booklet should be followed strictly.
  • The installer is to ensure that the requirements of the local authority, local electrical installation code, municipal building codes, and any other relevant statutory regulations are carried out.
  • Do not place articles on or against this appliance.
  • To reduce the risk of fire, do not store or use gasoline or other flammable vapours and liquids in the vicinity of the heater.
  • This Installation, Operation and Service manual should not be removed from the site of installation. Installer should leave manual with the customer for future reference.
  • A minimum safety distance of 1000mm (39.4”) should always be left in front of the appliance.
  • For commercial and residential installations, this unit must be either wall mounted at a minimum of 1800mm (71”) above the floor or ceiling mounted at a minimum of 2400mm (96”) above the floor.
  • The appliance must not be located directly below or in front of an electrical socket. Heat radiated from the appliance may damage the electricity outlet or plug if placed incorrectly.
  • Any guard or other protective device removed for servicing (conducted by an authorised person) must be replaced before operating the heater.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Heaters are not intended to be installed in wardrobes.
  • Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
  • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns, clothing ignition, or other serious personal injury.
  • This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (1m) from the front of the heater and keep them away from the sides and rear.
  • Keep packaging materials out of reach of children.
  • Do not spray aerosols or flammable materials in the vicinity of this appliance while it is in operation.
  • Installation and repair must be carried out by a qualified & licenced service person only. The heater should be inspected before use and at least annually serviced & inspected by a qualified & licenced service person.
  • Do not perform maintenance until heater has been turned off, power disconnected, and heater temperature has cooled to room temperature.
  • Clothing or other flammable materials should not be hung from the heater or placed on or near the heater.
  • Be sure the heater is not facing the ceiling or flammable or combustible substances/materials.
  • IMPORTANT – Installation MUST be carried out by a licensed and authorised person.
  • DO NOT leave heaters ON unattended for prolonged use and inspect the heating space regularly.
  • Improper installation, adjustment, or alteration and failure to follow the warnings and instructions in this manual could result in severe personal injury, death or property damage.
  • The manufacturer is not responsible for any damage that could happen from improper use. The manufacturer emphasises that this appliance should be used in a responsible manner and that all procedures, warnings, and safety instructions contained in this booklet should be followed strictly.
  • The installer is to ensure that the requirements of the local authority, local electrical installation code, municipal building codes, and any other relevant statutory regulations are carried out.
  • Do not place articles on or against this appliance.
  • To reduce the risk of fire, do not store or use gasoline or other flammable vapours and liquids in the vicinity of the heater.
  • This Installation, Operation and Service manual should not be removed from the site of installation. Installer should leave manual with the customer for future reference.
  • A minimum safety distance of 1000mm (39.4”) should always be left in front of the appliance.
  • For commercial and residential installations, this unit must be either wall mounted at a minimum of 1800mm (71”) above the floor or ceiling mounted at a minimum of 2400mm (96”) above the floor.
  • The appliance must not be located directly below or in front of an electrical socket. Heat radiated from the appliance may damage the electricity outlet or plug if placed incorrectly.
  • Any guard or other protective device removed for servicing (conducted by an authorised person) must be replaced before operating the heater.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Heaters are not intended to be installed in wardrobes.
  • Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
  • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns, clothing ignition, or another serious personal injury.
  • This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (1m) from the front of the heater and keep them away from the sides and rear.
  • Keep packaging materials out of reach of children.
  • Do not spray aerosols or flammable materials in the vicinity of this appliance while it is in operation.
  • Installation and repair must be carried out by a qualified & licenced service person only. The heater should be inspected before use and at least annually serviced & inspected by a qualified & licenced service person.
  • Do not perform maintenance until heater has been turned off, power disconnected, and heater temperature has cooled to room temperature.
  • Clothing or other flammable materials should not be hung from the heater or placed on or near the heater.
  • Be sure the heater is not facing the ceiling or flammable or combustible substances/materials.
  • This heater is not equipped with a device to control the room temperature. Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.
  • Fire Sprinklers must be located at an appropriate distance from each heater to avoid accidental activation of the sprinkler. Ethylene glycol or propylene glycol must never be used in fire sprinkler systems where heaters are present as these substances maybe become flammable when heated. A fire sprinkler professional must be consulted when heaters are installed where fire sprinklers are present to ensure that heaters and the fire sprinkler system are properly integrated.
  • It is recommended to call the service company at least once a year to check the general status, the heating functions and the integrity of linked safety devices (RCD and CB).
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard.
  • Keep the cable away from sharp edges during handling and installation.
  • Do not bend the electrical connection to the power supply.
  • Do not pull on the cable or subject it to traction force.
  • Avoid physical shock & impact to the heater when handling and after installation.
  • Do not apply any pressure on the glass surface. Never hit the glass.
  • Never use steam cleaners for cleaning of the appliance.
  • Keep the electrical connection area to the power supply clean.
  • Ensure that the heating unit is not directly exposed to rain or water contact.
  • Do not install or use the heater in any way other that indicated in the instruction leaflet.
  • Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
  • If any part of the instruction manual is missing or damaged, contact Bromic for a complete version.
  • If you are unsure of any aspect of the installation, contact Bromic for advice.

PRODUCT OVERVIEW$

The Platinum Smart-Heat™ Electric is designed to provide efficient spot heating for commercial and residential, land and coastal applications. The heaters are built with corrosion-resistant materials, have electrical approval in North America, Europe and Australia, and are rated to IP55 water Ingress Protection for the Marine variants and IP54 water Ingress Protection for the NonMarine variants. Making the Platinum Smart-Heat™ Electric the perfect solution for a variety of indoor and outdoor heating applications.

SPECIFICATIONS

Model:| Platinum Smart-Heat™ Electric II
Variant:| Standard – IP54| Marine – IP55
Region:| AU/NZ| EU/UK| US/CA| AU/NZ| EU/UK| US/CA

Part no.

| Black| 2622000| BH3622000| BH3622000| BH3622004| 2622002| BH3622002| BH3622002| BH3622006
White| 2622001| BH3622001| BH3622001| BH3622005| 2622003| BH3622003| BH3622003| BH3622007
Heat Output:| 4500 W
Power connection required:| 220-240 V – A.C.

50/60 Hz – 18.8 A

| 208 V – A.C.

60 Hz 21.6 A

| 220-240 V – A.C.

50/60 Hz – 18.8 A

| 208 V – A.C.

60 Hz 21.6 A

Dimensions:

(W x H x D)

| 1351 x 257 x 54 mm

(53.2” x 10.1” x 2.1”)

Weight:| 15kg (33lbs)
Finish:| Brushed Stainless Steel 304| Brushed Stainless Steel 316
Approval:| AU/NZ: RCM – Intertek

EU/UK: CE/LVD – Intertek – 200802166 SHA-V1       CB – Intertek – SE-102296

USA/CAN: cETLus – Intertek – 5001799

PRODUCT FEATURES

  • Ultra-thin and stylish design
  • Efficient directional spot heating
  • Heat Zones — one or more heaters can be switched on and off simultaneously from a single remotelocated switch – (controller to be purchased separately).
  • Platinum Smart-Heat™ Electric Heaters can also be integrated into smart control systems – with the additional purchase of the Smart-Heat™ Link.
  • Wind resistant & IP55 water protection rating for Marine Variants.
  • Wind resistant & IP54 water protection rating for Standard Variants.
  • Ceiling and Wall Mounting Bracket – included with heater
  • Optional Mounting Brackets – purchased separately from heater:
    • Ceiling Recess Kit
    • 600mm Tube Suspension Kit
    • 1200mm Tube Suspension Kit

HEATING INSTALLATION INSTRUCTIONS

CEILING & WALL MOUNTING
Application for land and coastal installations ONLY Heaters must be installed according to the minimum installation clearances shown in these diagrams. The stated clearance to combustible materials represents surface temperature of 65°C (117°F) above room temperature. Building material with a low heating tolerance (such a plastic, vinyl siding, canvas, tri-ply etc.) may subject to degradation at lower temperature. It is the installer’s responsibility to assure that adjacent materials are protected.

Dimensions shown in mm (inches)

BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA
\(1\) BROMIC-4500W -Platinum-
Smart-Heat-Electric-Heater-Series-II-FEA \(2\)

OPTION 1
To exit the cable through the side of the wall mounting bracket, start from step 1.

  1. Unscrew and remove grey screw plug from the wall bracket (a).

  2. Attach the supplied metal cable gland (b) into the same hole from the outside of the bracket.
    NOTE: Continue to step 3 below
    OPTION 2
    To exit the cable through the wall bracket directly into your ceiling or wall cavity, start from step 3.

  3. Attach the mounting bracket to the desired ceiling or wall location, using fasteners appropriate for the surface (not supplied). Ensure the bracket is firmly secured with fasteners in all 4 holes (c) before proceeding.
    NOTE: For wall mounting, ensure the grey plug (a) or cable gland (b) is facing upwards.
    WARNING: In order to maintain respective IP ratings and stop water entering the bracket, the mounting surface MUST be protected from the rain using the black gasket provided.

  4. Ensure M6x14mm screws are inserted into both sides of heater bracket with approximately 6mm (0.3”) of the threaded shaft exposed under the screw head (d).BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA \(5\)

  5. For cable exit through the side of the wall bracket: feed heater power cable through cable gland in wall bracket (e).
    NOTE: This is easier when the top of the cable gland is completely removed when feeding the cable through the bracket. The cap can then be inserted onto the cable for fastening.

  6. For cable exit into the ceiling or wall cavity: make a small hole in the black gasket on the bracket mounting surface to pass the cable through. Make electrical connection now or feed cable into wall or ceiling for subsequent connection (f). This is described under ‘Electrical Installation’ on page 13.

  7. Insert heater bracket into mounting bracket by hooking M6 screws into place in mounting slots (g).

  8. To fix heater at desired angle, fully insert M3x10mm positioning screws (included with wall bracket) on both sides of mounting bracket whilst holding heater in the desired position (h). The heater can be positioned straight, or be angled 28° either way.

  9. Fit the smaller cover over the heater bracket so that the slots pass over the shafts of the M6x14mm mounting screws (i). Fit the larger cover over the smaller cover in the same way from the opposite side of the bracket (j). Use angled covers if heater is angled. Use straight covers if heater is not angled.

  10. Tighten mounting M6 screws firmly, ensuring covers fit snugly against the bracket on all sides (k).BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA \(6\)

CEILING RECESS KIT INSTALLATION (SOLD SEPARATELY)

Ceiling Recess Kit

Application| Standard – 4500W| Marine – 4500W
Region| AU/NZ| EU/UK/US/CA| AU/NZ| EU/UK/US/CA
Part Number| 2623000| BH3623000| 2623001| BH3623001
Material| Brushed Stainless Steel 304| Brushed Stainless Steel 316

WARNING

  • Instructions below are suitable for ceiling surfaces 10-30mm (0.4-1.2”) thick. For ceiling surfaces thicker than 30mm (1.2”), contact Bromic for alternative installation options.
  • The heater shall, under no circumstance, be covered with insulating material or similar material.
  • In ceiling recess installation, the heater must be completely protected against water contact from above.
  • Joists, beams and rafters shall not be cut or notched to install the heater.
  • INDIVIDUAL CLEARANCES TO COMBUSTIBLES ARE FIXED MINIMUMS
  • MINIMUM DISTANCE BETWEEN HEATERS MEASURED FROM EDGE OF HEATER MUST BE AT LEAST 500mm (20”)

CLEARANCE TO COMBUSTIBLES

BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA
\(7\)

IMPORTANT: ENSURE THE CORRECT CEILING RECESS KIT IS BEING USED. REFER TO THE TABLE ABOVE FOR MORE INFO.

  1. Prepare ceiling cut-out with dimensions as above to fit ceiling recess frame (a). Heater must be installed with heater surface at least 2400mm (94”) above the floor level, with 500mm (20”) clearance to the nearest wall on all sides of the heater. Minimum distances to combustibles within cavity must be according to the dimensions shown above.

  2. From below, bring ceiling frame up and into ceiling cutout. Fasten ceiling frame into non-combustible structural members (i.e. non-combustible joists/ battens/ etc.) at both ends and centre using appropriate screws (b).
    NOTE: The thickness of the ceiling surface dictates which locator hole to use. The fastening screws must be inserted into strong non-combustible structural members that can easily support the weight of the heater. Your installation may require re-enforcing before the frame can be safely installed.

  3. Unscrew and remove the grey plug from the wall bracket. Attach the supplied metal cable gland (c) into the same hole from the outside of the bracket.

  4. Feed heater power cable through cable gland (supplied) from inside of wall bracket (d).

  5. Ensure M6x14mm screws are inserted into either side of heater bracket with 6mm (0.3”) of the threaded shaft exposed under the screw head. (e).BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA \(10\)

  6. Insert heater bracket into mounting bracket by hooking M6 screws into place in mounting slots (f).

  7. Fix heater to bracket in straight position using M4x10mm positioning screws on either side of mounting bracket (g). Ensure M6 screws are sitting fully in the mounting slots (as if the heater were hanging from the wall bracket).

  8. Fit the smaller, straight cover over the heater bracket so that the slots pass over the shafts of the M6x14mm mounting screws (h). Fit the larger cover over the smaller cover in the same way from the opposite side of the bracket (i).

  9. Tighten mounting screws firmly, ensuring covers fit snugly against the bracket on all sides (j).

  10. Firmly tighten cable gland in wall bracket so that cable does not move when pulled.

  11. Attach the bracket end-cap to the wall bracket using the 4 x M5 screws and nuts provided (k).

  12. Carefully remove the 4 x M5 screws fastening the heater mounting bracket to the back of the heater. Be careful not to move or put any force on the bracket. Place the 2 halves of the ceiling recess mounting plate over the screw holes. Re-insert the screws & tighten them firmly. (l)

  13. Make electrical connection from heater to power supply. This is described under ‘Electrical Installation’ on page 13.

  14. Raise one long side of heater up into ceiling frame cavity & then raise whole heater into cavity. (m)

  15. Rotate the heater into level position in the ceiling cavity (n) and then lower down onto the ceiling frame . Ensure the heater brackets are hooked over the ceiling frame and sitting in the slots on both sides. (o)

TUBE SUSPENSION (SOLD SEPARATELY)

  • REFER TO TABLE FOR TUBE SUSPENSION KIT CONFIGURATIONS
    Tube Suspension Kit

    Application| Standard| Marine
    Material| Brushed Stainless Steel 304| Brushed Stainless Steel 316
    Kit **Description*| 23.62” (600mm)| 47.24” (1200mm)| 23.62” (600mm)| 47.24”(1200mm)
    Part Number AU/NZ| 2620243| 2620244| 2020564| 2020565
    Part Number EU/UK| BH3130023| BH3130024| BH3130056| BH3130057
    Part Number US/CA**| BH3130023-1| BH3130024-1| BH3130046| BH3130047

  • Application for land and coastal installations ONLY
  • Heater must be installed with heater surface at least 2400mm (94”) above the floor level.
  • Installation is identical to ‘Ceiling & Wall Mounting’ above.
  • Use Tube Suspension Kit (sold separately) instead of mounting bracket supplied with heater.
  • Tube Suspension Kit only suitable for ceiling mounting. Do not wall mount.

BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA
\(13\)

Heater must be installed according to the minimum installation clearances shown in these diagrams.

BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA
\(14\) BROMIC-4500W -Platinum-
Smart-Heat-Electric-Heater-Series-II-FEA \(15\)

WARNING

  • MINIMUM DISTANCE BETWEEN HEATERS MEASURED FROM EDGE OF HEATER MUST BE AT LEAST 500mm (20”)
  • This heater MUST be permanently installed by an authorized/ licenced person. Do not perform maintenance, or carry out installation or assembly procedure while electrical power is switched on. Wait 2 hours after switching off the heater before handling.
  • The stated clearance to combustible materials represents surface temperatures of 65°C (117°F) above room temperature. Building material with a low heating tolerance (such as plastic, vinyl siding, canvas, tri-ply etc.) may be subject to degradation at a lower temperature. It is the installer’s responsibility to assure that adjacent materials are protected.
  • ENSURE CORRECT KIT IS BEING USED FOR MARINE ENVIRONMENTS.
  • REFER TO THE TABLE ON THE PREVIOUS PAGE FOR PART NUMBERS.

ELECTRICAL INSTALLATION FOR AU/NZ/EU/UK – 220-240V

WIRING DIAGRAM – 4500W MODEL SINGLE PHASE 240V SUPPLY STANDARD INSTALLATION* (INDIVIDUAL ELEMENT CONTROL)BROMIC-4500W -Platinum-Smart-Heat-
Electric-Heater-Series-II-FEA \(16\)

WIRING DIAGRAM – 4500W MODEL SINGLE PHASE 240V SUPPLY OPTIONAL INSTALLATION*BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA
\(17\)

WIRING DIAGRAM – 4500W MODEL SPLIT PHASE 240V SUPPLY STANDARD INSTALLATION* (INDIVIDUAL ELEMENT CONTROL)BROMIC-4500W -Platinum-Smart-Heat-
Electric-Heater-Series-II-FEA \(18\)

For wiring instructions using:

  • Bromic Smart-Heat Electric Wireless Dimmer BH3130011-1/ BH3130020-1/ 2620276-1 or
  • ON/OFF Controller BH3130010-1/ BH3130019-1/ 2620275-1 refer to the instructions provided with the controller.

WIRING DIAGRAM – 4500W MODEL SPLIT PHASE 240V SUPPLY OPTIONAL INSTALLATION*BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA
\(19\)

WIRING DIAGRAM – 4500W MODEL THREE-PHASE Y 208V SUPPLY STANDARD INSTALLATION* (INDIVIDUAL ELEMENT CONTROL)BROMIC-4500W -Platinum-Smart-Heat-
Electric-Heater-Series-II-FEA \(20\)

WIRING DIAGRAM – 4500W MODEL THREE-PHASE Y 208V SUPPLY OPTIONAL INSTALLATION*BROMIC-4500W -Platinum-Smart-Heat-Electric-Heater-Series-II-FEA
\(21\)

WARNING

  • This heater MUST be permanently installed by an authorised/licensed person. Do not perform maintenance, or carry out installation or assembly procedures while electrical power is switched on. To disconnect heater, turn off power to heater circuit at main disconnect panel
  • ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Disconnect from electrical supply before installing or servicing this heater. Read and follow installation clearance requirements outlined in this manual. The appliance MUST be connected to a properly grounded electrical source.

ELECTRICAL INSTALLATION

  1. Check product label for correct voltage and wattage to ensure sure power source conforms to the heaters requirements.
  2. The power cable must positioned away from & protected from the enclosure of the heater.
  3. Make all connections in accordance with local electrical code regulations. For outdoor installation, all connections must be made in accordance with local electrical code regulations for outdoor wiring. Only use wiring components approved for outdoor use with minimum IP55 rating.

For wiring instructions using Bromic Smart-Heat Electric Wireless Dimmer BH3130011-1/ BH3130020-1/ 2620276-1 or ON/OFF Controller BH3130010-1/ BH3130019-1/ 2620275-1 refer to the instructions provided with the controller.

IMPORTANT: Electronic dimmer controls generate heat during operation. For Bromic heaters installed with Bromic Smart-Heat Electric Wireless Dimmer BH3130011-1/ BH3130020-1/ 2620276-1 or ON/OFF Control BH3130010-1/ BH3130019-1/ 2620275-1 It is essential to ensure dimmers are mounted in a clean, dry and well-ventilated position with clearance on all sides. It must be ensured the dimmers are not installed in a confined space, close to other heat-generating appliances or in the case of a multi-dimmer installation, not too close together. Dimmers must remain cool at all times. Please consult Bromic dimmer installation instructions for further details or for further questions please contact Bromic technical support services.

SERVICING

WARNING

  • ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Disconnect from electrical supply before servicing this heater.
  • Servicing and maintenance MUST be carried out by an authorised and licenced service person only. Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.
  • If the supply cord is damaged, it must be replaced by Bromic, a service agent of Bromic or similarly qualified persons in order to avoid a hazard. Contact Bromic for further information on replacement of the supply cord.

MAINTENANCE

  • Ensure that the heating unit is not directly exposed to rain or water contact. For longest product life, and to maintain product appearance, mount heater under cover and protect from rain and weather whenever possible.
  • The exterior housing of the heater should be inspected and cleaned regularly. To clean the appliance; ensure heater is off, and has been off for at least 2 hours after operation, before wiping off any dirt/dust with a soft damp cloth.
  • Salt in the air can cause rusting of metal, especially in adverse conditions such as coastal environments. Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product’s appearance.

TROUBLESHOOTING

SYMPTOM POSSIBLE CAUSE (S) CORRECTIVE ACTION
No heat 1.   Improper connection.

2.     Power failure.

| 1.   Check connection to power supply.

2.     Check mains for power failure.

Not enough heat| 1.   Heater too small for application.

2.     Heater mounted too high or too far.

3.     Incorrect voltage connected to heater.

| 1.   Add additional heater(s).

2.     Decrease mounting height or distance.

3.     Check correct supply voltage is provided.

Too much heat| 1.Heater too large for application.

2.Heater mount too low or too close.

3.Incorrect voltage connected to heater.

| 1.   Replace with smaller heater or install dimmer (not supplied).

2.     Increase mounting height or distance.

3.     Check correct supply voltage is provided.

bromic.com