JR AUTOMATION TPM-CW-300 Continuous TPM Antenna User Manual
- June 3, 2024
- JR AUTOMATION
Table of Contents
Continuous TPM Antenna
Model Number: TPM-CW-300
Includes Variants: TPM-LA-300-000 & TPM-SA-300-000
User Manual
GENERAL IFORMATION & CONSIDERATIONS
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
Additionally:
- Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
- JR Automation TPM products & related equipment must be integrated into the end users manufacturing system by JR Automation, or by a JR Automation recommended automation Systems Integrator.
- JR Automation TPM products are meant for industrial manufacturing settings only.
- JR Automation does not manufacture or provide TPM valve stems, only the equipment that is used to communicate to those stems during tire, wheel, & vehicle manufacturing.
RF EXPOSURE STATEMENT
The device shall be used in such a manner that the potential for human contact
normal operation is minimized.
This equipment complies with RSS-102 radiation exposure limits. This equipment
should be installed and operated with a minimum distance of 20 cm between the
radiator and your body. This device and its antenna(s) must not be co-located
or operating in conjunction with any other antenna or transmitter.
SAFETY
-
Only personnel who are properly trained and have adequate knowledge and skill related to this product should undertake any troubleshooting and repair.
-
It must be assumed at all times that POWER is “ON” so all conditions must be treated as live. This practice develops a caution that may prevent an accident. Follow posted lockout procedures.
-
REMOVE LOAD from circuit or equipment before and after maintenance/troubleshooting.
-
Equipment—NOTE: Test equipment must be checked at regular intervals.
-
Capacitors MUST be given time to discharge, otherwise it should be done manually with CARE.
-
When troubleshooting “LIVE” equipment, the necessary precautions must be taken as follows:
a. Follow written safe operating practices.
b. MAKE CERTAIN your tools and body are clear of Ground.
c. Use extra PRECAUTION in DAMP areas.
d. BE ALERT and work without any outside distraction. -
BEFORE applying POWER to any equipment, it must be established without a DOUBT that all persons are CLEAR.
-
Any CONTROL PANEL DOORS shall be open ONLY when it is necessary to check out the electrical equipment or wiring. After CLOSING the door, make certain that the disconnecting means is operating properly with the DISCONNECT HANDLE MECHANISM.
-
ALL COVERS or junction boxes SHOULD be CLOSED before leaving any job.
-
BEFORE STARTING, read and understand all WARNING markings and notices.
-
READ all marking such as nameplates and identification plates.
-
DO NOT alter circuits unless authorized to do so by the manufacturer.
-
DO NOT alter or by-pass protective interlocks.
-
DO NOT place jumper wires across fuses.
-
DO NOT alter over-current protective devices.
-
GROUND connections allow fault currents to flow directly into the ground instead of following through the body then into the ground. ALL ELECTRICAL APPARATUS MUST BE PROPERLY GROUNDED.
-
Use CAUTION when connecting test equipment probes to test points. SHOCK HAZARDS could exist at the test points or in the test point area and/or TRANSIENTS induced by the problems could cause a MACHINE ACTION.
-
AVOID wearing a necklace, ring or chain that is made of a METALLIC substance.
-
All electrical wiring and items related to electrical controls are, and shall always be, in compliance with current National & Local Regulations.
RSONAL PROTECTIVE EQUIPMENT
When servicing, protect yourself by wearing protective equipment where required:
- Safety Glasses—Must be properly fitted and worn when a hazard exists.
- Gloves—Although it is recommended that gloves not be worn unless absolutely necessary, gloves can protect the hands from cuts or abrasions caused by slings or sharp edges. Do not use gloves when working on a tool with rotating equipment.
GROUNDING
The TPM antenna system must be properly grounded. Each of the following must be grounded ultimately to the installation sites grounding system:
- Transmission antenna’s metal shielding (for products that include a metal shield)
- The conduit between the transmission antenna and antenna enclosure
- The antenna enclosure
- Antenna stand or mounting structure
ELECTRICAL WARNING SIGNS
The antenna enclosure is marked with high voltage warning labels. The
antenna system is capable of generating high voltages. The enclosure cover
should be kept in place during operation. Only trained, qualified personnel
should remove the enclosure cover.
TPM STEM OVERVIEW
The purpose of this section is to provide an overview of the TPM valve stems.
The scope of this manual is to cover the operation of the JR Automation
antenna systems that communicate to the stems, not detailed information on the
TPM valve stems themselves. But a general overview of how TPM valve stems
operate will help the users understand the operation of the antenna equipment.
It should be noted that JR Automation does not manufacture or provide TPM
valve stems
TPM valve stems are electronic valve stems that are designed to warn a vehicle
driver when the tire inflation pressure is outside acceptable limits. The
stems contain pressure sensors and RF communications devices to allow the
stems to detect a bad inflation pressure, and then tell the vehicle computer
system that an inflation problem exists. This allows the vehicle computer to
annunciate the problem to the driver of the vehicle, usually with a dashboard
indicator of some kind.
Tire Pressure Monitor sensors or TPM valve stems are manufactured by several
different manufacturers. These stems vary greatly in shape, electrical design,
function, communication method, and RF characteristics. It is this high degree
of variation that poses the greatest challenge for a single antenna system to
communicate to all these different stems.
TPM stems are designed to monitor and report on the conditions inside the tire
(e.g. tire internal air temperature, pressure, and stem battery voltage). The
stem will transmit this information via a UHF radio signal (usually 315MHz or
433 MHz). This is typically referred to as a “wake up”. These wake-up
transmissions happen in response to different events, or in different modes.
The one that we are most concerned with utilizes the LF wake up signal. All
TPM stems are designed to respond with a UHF data transmission after receiving
a 125kHz LF wakeup signal. Below is a table of some of the different UHF
wakeup’s that are common to stems.
Event | Common Mode Name | Additional Info. |
---|---|---|
Inflation Pressure changes | Re-measure or Alert mode | Usually rapidly |
repeating wakeups
Motion in the wheel assembly| Drive mode| Can cause wakeups in spinning
process equipment, such as balancers
Time interval| Stationary mode| Stem automatically wakes up at a programmed
time interval, such as every hour
Stem Receives an LF Radio Signal| Learn mode, LF mode| This is meant for
manufacturing purposes and for use during tire servicing. This is the method
that JR TPM Antennas utilize to communicate to the stems.
LF TRANSMISSION (125KHz)
THIS MODEL ONLY GENERATES A CONTINUOUS LF TRANSMISSION
The JR Automation TPM Antenna systems were developed to utilize the LF (Low
Frequency) transmission to collect data from the TPM stem. The TPM stem
responds with the 125 kHz wakeup signal can be of 2 different types –
Continuous and Modulated LF. Each is described below.
Continuous LF: A stem requiring a continuous signal or a signal with no
change. It is simply a continuous sine wave signal at a given frequency (125
kHz in our case). The stem will periodically “listen” for an LF broadcast. If
it hears the broadcast for a specific amount of time (typically 1-3 seconds)
the stem will respond with its UHF broadcast. This is also commonly referred
to as “non-modulated LF”.
Modulated LF: In this case, the LF signal is turned off and on off
quickly. This creates a pattern of pulses. Generally, a unique pattern is
generated for each stem type. The stems are designed to wake up only if it
hears a signal using its unique pattern. The antenna will generate this unique
pattern over and over until it receives the UHF wake up response from the
stem. The pulse pattern that is generated by the antenna forms a message
packet. An individual packet is repeated over and over during the LF
transmission. This repetition of the packet gives the stem’s receiving
circuits multiple changes to receive the message, and to validate it. The
pattern within the packet is arranged into a “structure”. Typically, a packet
structure consists of several fields, with each having a specific purpose.
This unique data structure is specified by the TPM Valve Stem manufacturer.
RECEIVING UHF SIGNALS
After the TPM stem receives the wake up signal it will transmit a UHF data
package. The stems transmit data in one of two frequency bands 315 MHz and 433
MHz bands depending on the stems design. Typically, 315 MHz is used in the
U.S. and 433 MHz is used in export vehicles. The frequency used is governed by
the FCC in the United States. Vehicle’s being sold in other countries will be
governed by that country’s RF communications governing body.
Like the Modulated LF message structure, the basic unit for a UHF transmission
is a packet. This packet will be coded in a similar way that the LF data was
coded. After a valid wake up signal is received by the stem, it will typically
transmit the same data packet several times in “bursts”. The number of packets
in a burst varies from stem to stem. It can even vary for a single stem type,
based on the mode the stem is in. With all the different stems that have been
observed to date, the number of bursts can be in as few as 4 packets repeated
to as many as 16 packets. Repetition of the packets helps ensure the highest
probability that data will be received. Also, receiving the same packet
multiple times helps ensure that the data was received correctly, not some
falsely interpreted noise.
EXTERNAL CONNECTIONS & LED INDICATORS
The antenna box has 5 external connections. Please see the table & pictures below:
Connection | Description | Function |
---|---|---|
Power | Provide 24 VDC power to antenna system | |
RS485 | Provide RS485 Communication to the antenna from a system |
controller (provided by System Integrator)
Antenna 1| Connection for a 315MHz or 433 MHz receiver antenna.
Connected to receiver 1
Antenna 2| Connection for a 315MHz or 433 MHz receiver antenna.
Connected to receiver 2
LF Antenna Bulkhead| Provides conduit connection for LF transmission
antenna coil wiring
In addition to the external connections, the Antenna Enclosure has 4 indicator LED’s:
LED Description | Function |
---|---|
LF On | Illuminates when the antenna system is transmitting an 125KHz LF signal |
Receiver 1 | Momentarily flashes whenever a valid UHF packet is received from a |
TPM valve stem, on receiver 1 (antenna 1)
Receiver 2| Momentarily flashes whenever a valid UHF packet is received from a
TPM valve stem, on receiver 2 (antenna 2)
Power on| Illuminates when the antenna is supplied with 24VDC
ANTENNA MOUNTING
The antenna is typically mounted on an adjustable stand that is sold as a separate accessary. The stand also holds the antenna enclosure, which is mounted on a backplate. Typically, this will be provided by the Automation System Integrator.
APPENDIX A: PRODUCT DATA SHEET
The table below summarizes the general product data and specifications:
Attribute: | Data: |
---|---|
Manufacturer Name (Legal Entity) | Esys Automation LLC |
Model # | TPM-CW-300 (variants: TPM-LA-300-000 & TPM-SA-300-000) |
Brand Name (Marketed by) | JR Automation |
Country of Origin | USA |
Country of Assembly | USA |
Trade Name | Large Continuous Antenna |
General HS Code Category (Trade Code) | 8517.62 |
Mexico HS Code (Trade Code) | 8517.62.99 |
Low Frequency Transmission (LF) | 125 KHz |
Ultra High Frequency Receivers (UHF) | 315 MHz and 433 MHz |
Input Voltage | 24 VDC |
External communication interface protocol | RS485 Serial |
Product Packaging | No retail packaging included |
1000 Brown Rd.
Auburn Hills, MI 48326
248.754.1900
jrautomation.com
Canada
Prelim 1
Page 11 of 11
Printed: 11/16/22
3:36 PM
Documents / Resources
| JR
AUTOMATION TPM-CW-300 Continuous TPM
Antenna
[pdf] User Manual
TPM-CW-300-000, TPMCW300000, 2A4GATPM-CW-300-000, 2A4GATPMCW300000, TPM-
LA-300-000, TPM-SA-300-000, TPM-CW-300 Continuous TPM Antenna, TPM-CW-300,
Continuous TPM Antenna, TPM Antenna, Antenna
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>