Product Information

Specifications:

  • 5.8Ghz bandwidth

  • 5725 – 5850MHz

  • Working Range: Up to 70ft actual range; depends on RF signal
    absorption, reflection, and interference.

  • Audio Frequency Response: Dynamic Range & Signal-To-Noise
    110dB

  • Battery Life: 8 Hours

  • RF Sensitivity: -90dBm

  • Total Harmonic Distortion: (specification missing)

Product Usage Instructions

Charging:

Charging time: 2.5 hours. Use the USC-C charging port for both
the Transmitter and Receiver.

How to Use:

  1. Turn on the Transmitter and Receiver power by holding the Power
    button for 3 seconds.

  2. Connect the Transmitter to your Guitar.

  3. Connect the Receiver to the guitar pedal or guitar amp.

How to Pair:

Hold the Power / sync button for 5 seconds. The Status Led will
flash red and blue. After successful pairing, the Status Led will
turn green.

Frequency Tables:

Frequency Point Frequency (MHz)
1 5730

Frequently Asked Questions (FAQ)

Q: What types of instruments can this wireless system be used

with?

A: This system can be used with Acoustic guitar, Electric
guitar, and Electric bass guitar.

Q: What is the battery life of this wireless system?

A: The battery life is approximately 8 hours.

“`

5.8Ghz Guitar Wireless System
BASIC OPERATION
Transmitter
USC-C charging port Power / sync button 1/4″ Input jack Active / Passive mode switch
Active mode for active guitar pickup Passive mode for Passive guitar pickup

Receiver
USC-C charging port Power / sync button 1/4″ output jack
Transmitter and Receiver logo
1/4″ adapter

USE WITH MULTIPLE INSTRUMENT TYPES
Acoustic guitar, Electric guitar, Electric bass guitar.
Status Led
How to charging
Charging time: 2.5 hours

How to use

1. Turn on the Transmitter and Receiver power, hold on the Power button 3 sec. 2. Transmitter connect to Guitar 3. Receiver connect to the guitar pedal or guitar amp

How to pair

Hold on the Power / sync button 5sec. The Status Led will flash red and blue led. After successful pairing the Status Led will be green.

5.8Ghz Frequency Tables

1 Frequency point 2 Frequency point 3 Frequency point 4 Frequency point 5 Frequency point 6 Frequency point 7 Frequency point 8 Frequency point

5730MHZ 5735MHZ 5743MHZ 5753MHZ 5758MHZ 5764MHZ 5774MHZ 5781MHZ

9 Frequency point 10 Frequency point 11 Frequency point 12 Frequency point 13 Frequency point 14 Frequency point 15 Frequency point 16 Frequency point

5789MHZ 5799MHZ 5804MHZ 5811MHZ 5820MHZ 5830MHZ 5836MHZ 5844MHZ

Specifications

5.8Ghz bandwidth

5725 – 5850MHz

Working Range

Up to70ft actual range; depends on RF signal

absorption, reection and interference.

Audio Frequency Response

20Hz ­ 20KHz(-2dB)

Dynamic Range & Signal-To-Noise 110dB

Ratio

Battery Life

8 Hours

RF Sensitivity

-90dBm

Total Harmonic Distortion

<0.1%, 100mVrms 1Khz

RF Output Power

<25 mW E.I.R.P. max

Latency

Less than 5ms

High Resolution audio

24-bit/48kHz

Charging current and voltage

5V, 0.6A

IC warning statements:
-English Warning Statement: RSS-GEN ISSUE 5, 8.4 User manual notice This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. The digital apparatus complies with Canadian CAN ICES-3 (B)/NMB-3(B). -French Warning Statement: RSS – Gen version 5, 8.4 avis du manuel de l’utilisateur Cet appareil contient un émetteur / récepteur sans licence conforme au RSS sans licence d’innovation, science et développement économique Canada.L’opération doit satisfaire aux deux conditions suivantes: Cet équipement peut ne pas causer d’interférence. L’équipement doit accepter toute interférence, y compris toute interférence qui pourrait entraîner un fonctionnement indésirable de l’équipement.
Specific Absorption Rate (SAR) information: This device meets the government’s requirements for exposure to radio waves. The guide lines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. The SAR limit of ISED (Canada) is 1.6 W/kg averaged over one gram of tissue. Device types: Portable _PMN NAME_WIRELESS SYSTEM (IC: 8690A-TELPR6211) has also been tested against this SAR limit. according to this standard is less than 1.6W/kg w. Informations sur le débit d’absorption spécifique (DAS) : cet appareil est conforme aux exigences gouvernementales en matière d’exposition aux ondes radio. Les lignes directrices sont basées sur des normes qui ont été élaborées par des organisations scientifiques indépendantes grâce à une évaluation périodique et approfondie d’études scientifiques. Les normes comprennent une marge de sécurité substantielle conçue pour assurer la sécurité de toutes les personnes, quel que soit leur âge ou leur état de santé.
La limite SAR d’ISED (Canada) est de 1,6 W/kg en moyenne sur un gramme de tissu. Types d’appareil : Portable PMN NAME WIRELESS SYSTEM (IC : 8690A-TELPR6211) a également été testé par rapport à cette limite SAR. selon cette norme est inférieure à 1,6 W/kg w.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals