Health o meter 201HR Wall Mounted Telescopic Metal Height Rod Instruction Manual
- September 26, 2024
- Health o meter
Table of Contents
201HR Wall Mounted Telescopic Metal Height Rod
“`html
Product Information
Specifications
Height Range: Min: 2 / 6 cm, Max: 90 / 230
cm
Display Units: Centimeters (cm), Inches (in),
Feet/Inches
Accuracy: Environmental
Physical Dimensions: Not specified
Product Usage Instructions
201HR Wall Mount Instructions
Carton Contents:
- User instructions (1)
- Height rod (with attached headpiece) (1)
- Footpiece
- Small Clear Bag Containing:
- Black footpiece caps (2)
- Drywall anchors (3)
- White spacers (3)
- 1/2 Screws (2)
- 2 Screws (only 3 are required for assembly)
Tools Required (not included): Drill,
5mm (3/16) drill bit, 1.50mm (1/16) drill bit, Phillips head
screwdriver, Level
201HR Preparation
-
Carefully remove the product from the carton and place it on a
flat and dry surface. -
Attach the footpiece to the bottom of the height rod by
aligning the sides and sliding it completely to the bottom. -
Insert the screws into the holes at the bottom of the height
rod and tighten securely. -
Attach the black end caps to the ends of the footpiece.
Wall Mount Instructions
Caution: Ensure mounting location is
free of hazards and can support the height rod. Do not mount on a
door.
-
Determine mounting location and position the height rod with
the footpiece resting on the floor and end caps against the
wall. -
Use a level to ensure vertical straightness and mark screw hole
locations. -
Drill lead holes based on the type of wall material using
appropriate drill bits.
Frequently Asked Questions (FAQ)
Q: Can the height rod measure in both metric and imperial
units?
A: Yes, the height rod can display measurements
in both centimeters and inches.
Q: Is it safe to mount the 201HR on drywall?
A: Yes, you can mount the height rod on drywall
using the provided drywall anchors and screws.
“`
201HR WALL-MOUNTED TELESCOPIC
METAL HEIGHT ROD
USER INSTRUCTIONS
P/N UM201HR Rev20160429
201HR Thank you for purchasing this Health o meter® Professional product.
Please read this manual carefully, and keep it for reference or training.
TABLE OF CONTENTS
CAUTIONS AND WARNINGS……………………………………… 3 SPECIFICATIONS…………………………………………………… 3
CERTIFICATIONS / DISPOSAL / SERVICE……………………… 4 WALL MOUNT
INSTRUCTIONS…………………………………… 5 HEIGHT MEASUREMENT INSTRUCTIONS……………………… 10
MAINTENANCE………………………………………………………. 11 WARRANTY…………………………………………………………… 12
Please register your product for warranty coverage at: www.homscales.com
For User Instructions updates and revisions please go to: www.homscales.com
2
CAUTIONS AND WARNINGS
To prevent injury and damage to your product, please follow these instructions
very carefully. · For accurate measurement, the 201HR must be placed on a
stable wall
surface. · For accurate measurement, verify proper operation according to the
procedure described in this manual before each use. · Do not use in the
presence of flammable materials. · When not in use, fold headpiece into the
down position. · When mounting the 201HR, ensure that the mounting location is
free of
electrical lines, gas pipes, and other safety hazards. Ensure that wall is of
construction that can support the 201HR. · To prevent patient injury, the
patient must be attended throughout the entire measuring event.
SPECIFICATIONS
GENERAL The 201HR Wall-Mounted Height Rod has a large headpiece and features
an indicator that allows for accurate measurement of a patient’s height. Each
201HR is designed to determine the height of a stationary patient. Height is
displayed in centimeters (cm), inches (in), and feet/inches.
Height Range 201HR: Min : 2″ / 6 cm Max : 90″ / 230 cm
Environmental
Accuracy Physical Dimensions
Operating temperatures: 5°C to 40°C (41°F to 104°F) Storage temperatures: 0°C
to 50°C (32°F to 122°F) Atmospheric Pressure: 500hPa to 1060hPa Maximum
Humidity: 85% RH in use or in storage 201HR: +/- 1 mm (1/8″)
201HR: Width: 2 1/4″ / 5.7 cm (13″ / 33 cm including footpiece) Depth: ¾” /
1.9 cm (1 ¾” / 4.4 cm including spacers) Height: 54″ / 137 cm (92″ / 230 cm
with height rod fully extended) Headpiece Depth: 11″ / 28 cm
3
CERTIFICATIONS / DISPOSAL / SERVICE
CERTIFICATION DESCRIPTIONS Pelstar, LLC has been officially certified as a
manufacturer of Health o meter® Professional medical devices to be in
compliance with stringent ISO requirements. The Pelstar, LLC quality assurance
system covers the development, production, sales and service of medical scales
and measuring systems.
201HR DISPOSAL This Health o meter® Professional product must be disposed of
properly. Follow the national, regional or local regulations which apply to
you for disposal of domestic waste.
SERVICE INFORMATION The 201HR Wall-Mounted Metal Telescoping Height Rod is
shipped disassembled in one tube. Carefully inspect the carton for shipping
damage before unpacking. If damage is found, contact Customer Service
immediately. For further information or telephone support, please contact a
Health o meter® Professional Customer Service representative at
1-800-815-6615.
4
201HR WALL MOUNT INSTRUCTIONS
To avoid damaging the 201HR when unpacking it, do not use a box cutter, knife,
scissors or any sharp object when opening the protective inner packaging. If
damage is found, contact your shipper or a Health o meter® Professional
representative immediately. Claims must be filed with the shipper as soon as
possible after receipt of the package. The following information details what
you will find inside the carton as you unpack the parts for assembly. Set the
carton aside for storage. Parts List
Carton (1) User instructions (1) Height rod (with attached headpiece) (1)
Footpiece Small Clear Bag Containing:
(2) Black footpiece caps (3) Drywall anchors (3) White spacers (2) 1/2″ Screws
(4) 2″ Screws (only 3 are required for assembly)
Tools Required (not included) Drill, 5mm (3/16″) drill bit, 1.50mm (1/16″)
drill bit, Phillips head screwdriver, Level
5
201HR WALL MOUNT INSTRUCTIONS (CONT.)
201HR Preparation
1. Carefully remove the product from the carton, and place on a flat and dry
surface.
2. Attach the footpiece to the bottom of the height rod by aligning the sides
of the height rod with the slits in the footpiece. Be sure the height rod
slides completely to the bottom of the footpiece.
3. Insert the two 1/2″ screws from the clear bag into the holes at the bottom
of the height rod. Use a Phillips head screwdriver to tighten the screws
securely.
4. Obtain the two black end caps from the clear bag. Attach them to the ends
of the footpiece. The front of the end cap should be flush with the front of
the height rod.
6
201HR WALL MOUNT INSTRUCTIONS (CONT.)
Wall Mount Instructions Caution: When wall mounting the 201HR, ensure that the
mounting location is free of electrical lines, gas pipes, and other safety
hazards. Ensure that wall is of construction that can support the 201HR. Note:
Do not mount the 201HR on a door.
1. Determine where the height rod will be mounted.
2. Position the height rod so that the back of the end caps are facing the
wall. The footpiece should be resting on the floor and the end caps should be
flush against the wall. The height rod should be vertically straight and not
leaning against the wall. There must be room between the wall and the height
rod to allow for the spacers to be inserted.
3. Use a level to ensure the height rod is vertically straight and plumb.
While holding the level and height rod in place, insert a thin pencil or screw
to mark the screw hole in the top hole. Next mark the screw holes for the
center and bottom holes.
4.Once the holes are marked, set aside the height rod.
– If mounting to drywall or plasterboard, use a 5mm (3/16″) drill bit to drill
a lead hole into the marked location.
– If mounting to wood, wood studs or metal, use a 1.5mm (1/16″) drill bit to
drill a lead hole into the marked location.
5mm (3/16″) drill bit for
mounting on drywall or
plasterboard
1.5mm (1/16″) drill bit for
mounting on wood, wood studs or metal
7
201HR WALL MOUNT INSTRUCTIONS (CONT.)
5. If mounting to drywall or plasterboard, use a Phillips head screwdriver to
set a drywall anchor into the drilled hole in the wall.
Note: If mounting on wood, wood studs or metal, you do not need to install
drywall anchors and can skip to the next step. 6. Obtain three of the 2″
screws
and plastic spacers from the plastic bag. Reposition the height rod against
the wall lining up the holes with the drywall anchors or drilled lead holes.
Starting with the top hole, insert the screw through the front of the height
rod into the spacer placed behind the height rod then into the drywall anchor
or drilled lead hole. Using a Phillips head screwdriver, tighten the screw
only three turns to hold the height rod in place. Next, move to the bottom
hole of the height rod and insert the screw and spacer into the bottom drywall
anchor or drilled lead hole, again only tightening with three turns. Repeat
the process with the center hole.
8
201HR WALL MOUNT INSTRUCTIONS (CONT.)
7. a. Check alignment with a level and
verify correct measurements. If level or height measurement is off, repeat
steps 3-5. If height rod is level, tighten screws until height rod is securely
attached to the wall. b. Check that the height rod can slide down to measure
below 53″ / 134.5cm. To slide the height rod below 53″, press the black button
at the top of the height rod to release the lock then slide the headpiece
down. If height rod does not slide down, further tighten the screws into the
wall. Once level, with smooth upward and downward motion, the height rod is
ready for use.
9
HEIGHT MEASUREMENT INSTRUCTIONS
1. With the headpiece in the folded down position, slide the headpiece up or
down to the estimated height of the patient. For patients shorter than 53″ /
134.5cm, press the black button at the top of the height rod to release the
lock then slide the headpiece down. Then lift the headpiece into its
horizontal position.
2. Position the patient with their back against the height rod and their
heels touching the footpiece. Ensure that the patient’s posture is upright,
and that the patient’s head is straight and level. Slide the headpiece down
until it rests on the patient’s head.
3. Determine the patient’s height by reading the value at the read-off mark.
a. For heights above 53″ / 134.5cm, read height at the blue line in the center
of the height rod.
b. For heights below 53″ / 134.5cm, read height at the blue line at the bottom
of the headpiece.
Read here for heights
greater than 134.5 cm
Read here for heights less than 134.5 cm
10
MAINTENANCE
The following provides instructions for maintenance and cleaning for the
201HR. Maintenance operations, other than those described in this manual,
should be performed by qualified service personnel. Caution: Before first use,
or after long periods of non-use, check the product for any obvious damage or
wear and tear along with proper operation and function. If the 201HR does not
operate correctly, refer to qualified service personnel. Cleaning Proper care
and cleaning is essential to ensure a long life of accurate and effective
operation. 1. Clean all external surfaces with a clean damp cloth or tissue.
Mild antimicrobial or antibacterial soap and water solution may be used. Dry
with a clean soft cloth. Do not use abrasive cleaners. 2. Do not use Isopropyl
Alcohol or other solutions to clean the surface.
11
WARRANTY
Limited Warranty
What does the Warranty Cover? This Health o meter® Professional product is
warranted from date of purchase against defects of materials or in workmanship
for a period of two (2) years. If product fails to function properly, return
the product, freight prepaid and properly packed to Pelstar, LLC (see “To Get
Warranty Service”, below, for instructions). If the manufacturer determines
that a defect of material or in workmanship exists, the customer’s sole remedy
will be replacement of the product at no charge. Replacement will be made with
a new or remanufactured product or component. If the product is no longer
available, replacement may be made with a similar product of equal or greater
value. All replaced parts are covered only for the original warranty period.
Who is Covered? The original purchaser of the product must have proof of
purchase to receive warranty service. Please save your invoice or receipt.
Pelstar dealers or retail stores selling Pelstar products do not have the
right to alter, or modify or in any way change the terms and conditions of
this warranty.
What is Excluded? Your warranty does not cover normal wear of parts or damage
resulting from any of the following: negligent use or misuse of the product,
use on improper voltage or current, use contrary to the operating
instructions, abuse including tampering, damage in transit, or unauthorized
repair or alternations. Further, the warranty does not cover natural
disasters, such as fire, flood, hurricanes and tornadoes. This warranty gives
you specific legal rights, and you may also have other rights that vary from
country to country, state to state, province to province or jurisdiction to
jurisdiction.
To get Warranty Service make sure you keep your sales receipt or document
showing proof of purchase. Call (+1)
800-638-3722 or (+1)
708-377-0600 to receive a return
authorization (RA) number, which must be included on the return label. Attach
your proof of purchase to your defective product along with your name,
address, daytime telephone number and description of the problem. Carefully
package the product and send with shipping and insurance prepaid to: Pelstar,
LLC Attention R/A#_____ Return Department 9500 West 55th Street
McCook, IL 60525
PELSTAR, LLC
9500 West 55th Street · McCook, IL 60525 · USA
1-800-638-3722 or
1-708-377-0600
PLEASE REGISTER YOUR SCALE FOR WARRANTY COVERAGE AT: www.homscales.com
Health o meter® is a registered trademark of Sunbeam Products, Inc. used under
license. Health o meter® Professional products are manufactured, designed, and
owned by Pelstar, LLC. We reserve the right to improve, enhance, or modify
Health o meter® Professional product features or specifications without
notice.
© Pelstar, LLC 2016
P/N UM201HR Rev20160429
12
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>