STOLTZEN CP100 10 Inch Control Processor Instruction Manual
- September 26, 2024
- STOLTZEN
Table of Contents
STOLTZEN CP100 10 Inch Control Processor
Frequently Asked Questions
Q: Is surge protection necessary for this product?
A: Yes, surge protection is recommended to safeguard the sensitive electrical components of the Control Processor.
Q: How can I assign an IP address to the Control Processor?
A: If the Control Panel is DHCP enabled, ensure it’s connected to a router on the same network to assign an IP address. If not, you can connect your PC directly to the LAN port and modify the IP address in the network segment of 192.168.0.X for data communication.
Thank you for purchasing this product
For optimal performance and safety, please read these instructions carefully
before connecting, operating or adjusting this product. Please keep this
manual for future reference.
Surge protection device recommended
This product contains sensitive electrical components that may be damaged by
electrical spikes, surges, electric shock, lighting strikes, etc. Use of surge
protection systems is highly recommended in order to protect and extend the
life of your equipment.
Introduction
The programmable touch screen control panel is designed to be utilized in the sectors of automated office system, multi-media room and smart home. With a programmable interactive user interface over configuration protocols, the integrated system provides intelligent networking service. The control panel is equipped with a capacitive touch screen with a resolution of 1280*800, and it supports one RS-485 serial port. It is used in a diverse range of installations and applications across industries including multi-media conference rooms, multi-functional halls, training centers, show room, broadcasting studios and industrial automation.
Features
- ARM Cortex-A53 architecture 1.8Ghz main frequency
- Android 9.0 system, 8GB Emmc Flash, 2GB DDR4 RAM
- 1280*800 (16:10) resolution, desktop screen design
- One machine with two modes, can be used as touch screen central control or user terminal
- Support one RS-485 communication serial port, which is capable of configuring 8 baud rates in the range of 2400-115200bps
- Support access to the host system management web page with a password
- Compliant with industry standard network communication protocols (TCP/IP, Http, UDP, Websocket)
- With 1 Gigabit network port, the highest rate up to 1G/bps
- Support POE function or independent DC 24V/1A power supply
- Interface and function configuration via central control software
- Support remote control, remote O&M, online upgrade
- Support factory reset
Package Contents
- 1 × Programmable Touch Screen Control Panel (Desktop)
- 1 × 3pin-3.81mm Phoenix Connectors (male)
- 1 × 24V 1A Multinational Power Supply (2pin-3.81mm Phoenix Connector)
- 1 × User Manual
Specifications
Technical
CPU| ARM Cortex-A53 1.8GHz
Operation System| Android 9
RAM| 2GB DDR4 RAM
Flash Memory| 8GB EMMC Flash
Resolution| 1280*800
Touch Type| Capacitive Touch Screen
Connection
RS-485| 1 × 3-pin Phoenix Connectors, for RS-485 serial data communication
LAN/POE| 1 standard 10M/100M/1000M Ethernet RJ45 interface, supporting POE
function
POWER| 1 × 2-pin Phoenix Connectors, for power supply
DEBUG| 1 × Micro USB, system debugging port
Mechanical
Housing| Front Panel — Touch Screen; Rear Case — Aluminum Alloys
Color| Front Panel — Black; Rear Case — Apple Gray
Dimension| 245.4mm (L) × 164mm (W) × 27mm (D)
Weight| 887g
Power Supply| 24V DC/1A or POE
Power Consumption| 6W
Operation Temperature| 0°C ~ 40°C / 32°F ~ 104°F
Relative Humidity| 10~90% RH (non-condensing)
Operation Controls and Functions
No. | Name | Function Description |
---|---|---|
1 | Touch Screen | Capacitive touch screen. The user control interface can be |
configured through the IDE tool.
2| POWER
button
| Used for system power on/off, screen off or wake-up.
3
| ****
RESET
button
| Reboot: After the device boots up, press and hold the RESET button for more than 1s less than 5s, then release it, the device will reboot. The device won’t upload the user projects after rebooting.
Reset: After the device boots up, press and hold the RESET button for more than 5s, then release it, the device will reset the user configuration information, the IP will be restored to DHCP state, the login password of the manage- ment page will be initialized to “admin”, the device time will be initialized to automatic acquisition mode, but user projects won’t be deleted by factory initialization.
No. | Name | Function Description |
---|---|---|
4 | DEBUG port | Micro USB port. The reserved port for system debugging. |
5
| ****
LAN/POE
port
| Standard 10M/100M/1000M Ethernet RJ45 port with default auto-negotiated speed for device connection, projects uploading & downloading, network communication and debugging.
The control panel boots up with DHCP enabled by default. After powering on, when the control panel connects to a network where there is no router present to assign IP addresses, the control panel will take the pre-set IP address: 192.168.0.101. If there is a router present on the same network, the router will assign an IP address to the control panel in three minutes and the pre- set IP address will be invalid.
Note : When the control panel is DHCP enabled after power on, the router (if connected to the same network) will assign an IP address to the control panel. If network is disconnected at this time, the control panel won’t be able to pre-set an IP address and its IP address would be 0.0.0.0. If a pre- set IP address is needed, you need to power off the control panel and then power it on again. If it is in static IP mode after power on, the control panel won’t preset an IP address either. If there is no router present, you can connect your PC to the LAN port of the control panel and modify the PC’s IP address in the network segment of 192.168.0.X, then the PC will pre-set an IP address to the control panel
in three minutes for data communication.
6
| ****
RS-485 port
| Programmable RS-485 serial port, which is a 3-pin phoenix connector (male), compliant with RS-485 communication protocol, and capable of configuring 8 baud rates in the range of 2400-115200bps.
The pin-outs of the RS-485 ports are PIN1 for A, PIN2 for B, and PIN3 for GND.
7| POWER
port
| The power input port (2-PIN phoenix connectors), used for connecting with external 24V DC power supply.
Application Example
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>