Product Specifications

  • Product: Encore Profile Pro WW
  • Document Version: 4.0
  • Software Version: 1.07
  • DMX Channel Mode: 1/2/3/6

Product Information

General Information
The Encore Profile Pro WW is a professional lighting fixture designed for various applications. It offers a range of features and settings to enhance your lighting setup.

Installation

  • Flammable Material Warning: Keep the fixture at least 7.9in. (0.2m) away from any flammable materials, decorations, pyrotechnics, etc.
  • Electrical Connections: A qualified electrician should be used for all electrical connections and/or installations.
  • Minimum Distance to Objects/Surfaces: Must be 40 feet (12 meters).
  • Rigging: Overhead rigging requires extensive experience. Improper installation can result in bodily injury.

Accessory Installation
The product supports optional accessories that can enhance its performance. Refer to the manual for detailed instructions on how to install these accessories correctly.

System Menu
The system menu provides access to various settings and configurations to customize the operation of the fixture. Make sure to familiarize yourself with the system menu options for optimal performance.

DMX Setup | DMX Addressing
The DMX setup allows you to control the fixture using DMX protocols. Proper DMX addressing is essential for seamless integration into your lighting setup. Refer to the manual for detailed instructions on DMX setup and addressing.

Specifications
Refer to the specifications section for detailed technical information about the product, including document version, software version, and DMX channel modes supported.

FAQ

  • How do I update the software version of the Encore Profile Pro WW?
    To update the software version, visit www.adj.com for the latest revision/update of the manual. Follow the instructions provided in the updated manual for software updates.

  • Can I use the Encore Profile Pro WW without DMX control?
    Yes, the fixture can be used without DMX control by adjusting the settings using the onboard controls or menu options.

INTRODUCTION

  • ©2024 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies. ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
  • ADJ PRODUCTS LLC World Headquarters
  • ADJ Supply Europe B.V.
    • Junostraat 2
    • 6468 EW Kerkrade
    • Netherlands
    • Tel: +31 45 546 85 00
    • Fax: +31 45 546 85 99
    • www.americandj.eu
    • service@americandj.eu
    • Europe Energy Saving Notice
    • Energy Saving Matters (EuP 2009/125/EC)
  • Saving electric energy is a key to help protecting the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power
    • when not in use. Thank you!

DOCUMENT VERSION

  • Due to additional product features and/or enhancements, an updated version of this document may be available online.
  • Please check www.adj.com for the latest revision/update of this manual before beginning installation and/or programming.

Date| Document Version| Software Version >| DMX Channel Mode| Notes
---|---|---|---|---
07/23/2020| 1.0| 1.01| 2/3/6| Initial Release
08/09/2021| 1.5| N/C| N/C| Updated Specifications
10/12/2021| 2.0| 1.03| N/C| Updated System Menu, DMX Traits
02/06/2023| 2.5| N/C| N/C| Added Accessory Installation and Optional Accesso- ries; updated Installation
06/06/2023| 3.0| N/C| N/C| Updated specifications
02/13/2024| 3.5| N/C| N/C| Accessory Update
05/16/2024| 4.0| 1.07| 1/2/3/6| Added 1 Channel Mode

GENERAL INFORMATION

INTRODUCTION
Please read and understand all instructions in this manual carefully and thoroughly before attempting to operate these products. These instructions contain important safety and use information.

UNPACKING
The products in this kit have been thoroughly tested and have been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect each unit included for damage and be sure all accessories necessary to operate the units have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this kit to your dealer without first contacting customer support at the number listed below. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre- paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support.

LIMITED WARRANTY (USA ONLY)

  • ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
  • For warranty service, you must obtain a Return Authorization number (RA#) before sending back the product-please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, or for the safe return thereof.
  • This warranty is void of the serial number has been altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product, if the product has been repaired or service by anyone other than ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
  • This is not a service contact, and this warranty does not include maintenance, cleaning or periodic check up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts, and will absorb all expenses for warrant service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
  • ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
  • No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product.
  • This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

LIMITED WARRANTY PERIODS

  • Non L.E.D. Lighting Products = 1-year (365 days) Limited Warranty (Such as: Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands etc. excluding LED and lamps)
  • Laser Products = 1 Year (365 Days) Limited Warranty (excludes laser diodes which have 6 month limited warranty)
  • L.E.D. Products = 2-year (730 days) Limited Warranty (excluding batteries which have a 180 day limited warranty) Note: 2 Year Warranty only applies to purchases within the United States.
  • StarTec Series = 1 Year Limited Warranty (excluding batteries which have a 180 day limited warranty)
  • ADJ DMX Controllers = 2 Year (730 Days) Limited Warranty

SAFETY GUIDELINES

THIS FIXTURE IS COMPOSED OF SOPHISTICATED ELECTRONIC COMPONENTS. TO GUARANTEE SMOOTH OPERATION, IT IS IMPORTANT TO FOLLOW ALL INSTRUCTIONS AND GUIDELINES IN THIS MANUAL. ADJ PRODUCTS, LLC IS NOT RESPONSIBLE FOR INJURY AND/OR DAMAGES RESULTING FROM THE MISUSE OF THIS FIXTURE DUE TO THE DISREGARD OF THE INFORMATION PRINTED IN THIS MANUAL. ONLY QUALIFIED AND/OR CERTIFIED PERSONNEL SHOULD PERFORM INSTALLATION OF THIS FIXTURE AND ONLY THE ORIGINAL RIGGING PARTS INCLUDED WITH THIS FIXTURE SHOULD BE USED FOR INSTALLATION. ANY MODIFICATIONS TO THE FIXTURE AND/OR CERTIFIED PERSONNEL SHOULD PERFORM INSTALLATION OF THIS FIXTURE AND/OR THE INCLUDED MOUNTING HARDWARE WILL VOID THE ORIGINAL MANUFACTURER’S WARRANTY AND INCREASE THE RISK OF DAMAGE AND/OR PERSONAL INJURY.

  • PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED
  • THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
  • DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURE’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
  • DO NOT PLUG FIXTURE INTO A DIMMER PACK!
  • NEVER OPEN THIS FIXTURE WHILE IN USE!
  • UNPLUG POWER BEFORE SERVICING FIXTURE!
  • NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
  • KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
  • NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
  • RETINA INJURY RISK – MAY INDUCE BLINDNESS!
  • SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
  • INDOOR / DRY LOCATIONS USE ONLY!
  • DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE!
  • MINIMUM DISTANCE TO OBJECTS/SURFACES
  • MUST BE 6.6 FEET (2 METERS)
  • MAXIMUM TEMP OF EXTERNAL SURFACE 185° F (85°C)
  • MINIMUM DISTANCE OF INFLAMMABLE MATERIALS
  • FROM THE SURFACE 1.6 FEET (0.5 METER)
  • DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 60 minutes for the fixture to cool down before serving.
  • DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
  • DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease. NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of similar power rating.
  • DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
  • When installing fixture in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable.
  • Always disconnect fixture from main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.
  • During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
  • Consistent operational breaks will ensure fixture will function properly for many years.
  • ONLY Use original packaging and materials to transport the fixture in for service.

POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS

  • External sources of light beams from direct sunlight, lighting moving head fixtures, and lasers, which are focused directly towards the exterior housing and/or penetrate the front lens opening of ADJ lighting fixtures, can cause severe internal damage including burning to optics, dichroic color filters, glass and metal gobos, prisms, animation wheels, frost filters, iris, shutters, motors, belts, wiring, discharge lamps, and LEDs.
  • This issue is not specific to ADJ lighting fixtures, it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the following guidelines can prevent any potential damage from occurring if followed. Contact ADJ Service for more details.
  • DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM DIRECT SUNLIGHT, OTHER LIGHTING MOVING HEAD FIXTURES, AND LASERS WHILE UNPACKING, INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS. DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.

OVERVIEW

INSTALLATION

FLAMMABLE MATERIAL WARNING
Keep fixture at least 7.9in. (0.2m) away from any flammable materials, decorations, pyrotechnics, etc.

ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.

  • MINIMUM DISTANCE TO OBJECTS/SURFACES MUST BE 40 FEET (12 METERS)
  • MAXIMUM TEMPERATURE OF EXTERNAL SURFACE 167°F (75°C)

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

  • Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations. Before rigging/mounting the fixture to any metal truss/structure or placing the fixture on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture, clamps, cables, and accessories.
  • Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that meets all local, national, and country codes and regulations.
  • Fixture ambient operating temperature range is -14°F to 113°F. (-10°C to 45°C)
  • Do not use this fixture outside this temperature range.
  • Fixture should be installed in areas outside walking paths, seating areas, or away from areas were unauthorized personnel might reach the fixture by hand.
  • NEVER stand directly below the fixture when rigging, removing, or servicing.
  • Allow approximately 15-minutes for the fixture to cool down before servicing.

RIGGING
Overhead rigging requires extensive experience, including among others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
ALWAYS ATTACH AN APPROPRIATELY RATED SAFETY CABLE (NOT INCLUDED) THAT MEETS ALL LOCAL, NATIONAL, AND COUNTRY CODES AND REGULATIONS WHENEVER INSTALLING FIXTURE IN A SUSPENDED ENVIRONMENT!

INSTALLATION

Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Always use safety cables that can hold 12 times the weight of the unit when installing the fixture. This equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
The Encore Profile Pro WW is fully operational in three different mounting positions; hanging upside-down, mounted sideways on trussing, or set on a flat level surface. Please note that if the optional iris accessory has been installed, the unit can only be installed in an upright position position with the iris handle facing upward, in order to prevent the iris from accidentally falling out. Be sure this fixture is kept at least 12m (40ft) away from any flammable materials (decoration etc.).

OVERHEAD RIGGING:
The Encore Profile Pro WW includes two rigging options.

  1. OMEGA BRACKET – Mount the fixture with an appropriately rated professional grade rigging clamp (not included) to the included Omega Bracket using an M12 screw and nut (not included). With the rigging clamp securely attached to the Omega Bracket, attach the Omega Bracket to the fixture by inserting both of the 1/4-turn quick-lock fasteners into the aligning holes on the fixture yoke bracket, and turning each clockwise to secure.
    MAKE SURE THE OMEGA BRACKET IS SECURELY ATTACHED BEFORE RIGGING FIXTURE!

  2. MOUNTING YOKE – Mount the fixture with an appropriately rated professional grade rigging clamp (not included) to the fixture yoke bracket center hole using an M12 screw and nut (not included). MAKE SURE THE CLAMP IS

SECURELY ATTACHED BEFORE RIGGING FIXTURE!
SAFETY CABLE: Pull the safety-cable through the opening located on the rear of the unit and over the trussing system or a safe fixation spot. Insert the end in the carabiner and tighten the safety screw. Always use and install a safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails.

CLAMP INSTALLATION
When mounting fixture to truss, be sure to secure an appropriately rated professional grade rigging clamp to either the included Omega Brackets using an M10 screw fitted through the center hole of the Omega Brackets, or to the Mounting Yoke. The fixture provides a built-in rigging point for a SAFETY CABLE (not included). Be sure to only use one of the designated rigging point for the safety cable and never secure a safety cable to the carrying handle.

*SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS. The Safety Cable must be attached to the fixture and routed around the truss, or other secure fixation point, and both ends securely affixed to the carabiner attached at the built-in rigging points.

ACCESSORY INSTALLATION

LENS AND GOBO

ACCESSORY INSTALLATION

IRIS
Follow the steps below to install the optional iris accessory. Please note that when the iris is installed, the fixture should only be mounted in an upright orientation with the iris handle pointing upwards, to reduce the risk of the iris falling out.

  1. Locate the iris cover plate at the top of the fixture, just forward of the blade shutters. Loosen (but do not completely remove) the two thumb screws that hold the plate in place, then slide the cover plate forward to expose the iris slot.

  2. Orient the iris so that the tabs along the side are facing toward the front of the fixture, as shown above.

  3. Slide the iris down into the iris slot. Ensure that the tabs on the side of the iris are facing toward the front of the fixture.

  4. Slide the plate back to cover the iris slot, and tighten the thumb screws to secure in place. The plate should be in contact with the handle of the iris, but be careful not to push the plate too tightly against the handle. Do not overtighten the thumb screws.

SYSTEM MENU

The fixture includes an easy to navigate system-menu control panel display where all necessary settings and adjustments are made. (See image below) During normal operation, pressing the MENU button once will access the fixture’s main menu. Once in the main menu, you can navigate through the different menu’s with the UP, DOWN, and MENU buttons. When you reach a field that requires adjusting, press the ENTER button to access that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more to confirm your setting. You may exit the menu’s at any time without making any adjustments by pressing the MENU button. If there are no changes/adjustments made within 10 seconds, the unit will revert back to the setting made under “No DMX State”.

SYSTEM MENU

Supports Software Versions: 1.03

MENU| OPTIONS / VALUES (Default Settings BOLD)| DESCRIPTION

DMX Address

|

001

|

001 – 512

| Shall be used to set the units starting DMX address channel. Depending on set DMX mode, unit shall not allow to be addressed any higher that will not allow for all channels to be accessed from the console.
DMX Channel Mode| 1CH/ 2CH /3CH/6CH| Shall be used to set the units desired DMX mode.

Personality

| Status| Lost Dmx| Black/ Hold| No dmx status

LCD Set

| Display| ON /OFF| 30S blackout display
Key Lock| ON /OFF|
Flash| ON /OFF| No DMX Flash
Invert| ON/ OFF| Screen 180° flip

Disp. Set

| Address

CHAN. VAL

Pri/Sec

| Starting DMX Address

Shall display last active DMX value Primary/Secondary

|
Temp.C/F| C/ F|

Dim Mode

| Standard|
Stage|
TV|
Architec|
Theatre|
Stage 2|
Dim Spd| 0-10s|

Dim Curve

| Square|
Linear|
Inv. Squa|
S. Curve|

Frequen

| 900HZ, 1000HZ, 1100HZ, 1200HZ , 1300HZ,

1400HZ, 1500HZ, 2500HZ, 4000HZ, 5000HZ,

10KHZ, 15KHZ, 20KHZ, 25KHZ

|
PrimarySw| ON/ OFF| Primary transmit signal (should be on for primary & secondary)
USB_Data| ON/ OFF|
DFSE| ON/ OFF| Default Setting
Manual Control| ManCtrl| Strobe=XXX|
Dimmer = XXX|
Service| Calibrat| Password (50)|
WW LED = XXX|

Info

|

Time Info

| Current| Current fixture running time (H)
Total| Fixture total running time (H)
Last| Clear last fixture running time (H)

Password

| clear the current running time Password = 050, total running time

= 060

Clear| ON/ OFF
TempInfo| xxxF/xxxC|
Err.Info| None. Temp|
ModelInf| Encore Profile Pro WW|
Software| Vx.xx|

SYSTEM MENU

  • DMX Address – In this menu you can find and set your desired DMX address.
  • Channel Mode – In this menu you can find and set your desired DMX channel mode.
  • Function Status – This menu setting is used as a precaution mode in case the DMX signal is lost or interrupted. The operating mode chosen in this menu is the running mode the fixture will go into when the DMX signal is lost. Listed below are the 3 modes.
    • Hold – This setting will have the fixture stay in the last DMX setup.
    • Black – This setting will have the fixture automatically go into stand by mode.
  • LCD Set – In this menu you are able to activate/deactivate the display blackout and activate/deactivate the display lock.
  • Temp.C/F – Set temperature display between Celsius and Fahrenheit.
  • Dim Mode – In this menu you are able to select your desired dimmer mode and adjust the dimming speed time.
  • Disp. Set – In this menu you are able to activate/deactivate the display blackout and activate/deactivate the display lock.
  • Dim Curve – Set Dimming Curve
  • Frequen – Set fixture frequency.
  • primarySW- This transmits the DMX signal via a primary & secondary control hierarchy.
  • Service – In this menu you are able to access and adjust/change: the calibration (effect adjust) and restore the factory settings.
  • USB_Data – Turns USB data access on or off.
  • DFSE – Turns Default Setting on or off.
  • Time Info – Select between Current fixture running time and Fixture total running time. Only the Fixture Current fixture running time can be cleared
  • TempInfo – Displays fixture temperature.
  • Err.Info – Displays fixture error information.
  • ModelInf – Displays fixture information.
  • Software – Displays current software version.
  • ManCTRL – Manual Dimmer Control.
  • Strobe=XXXX – Test Strobe Effect.
  • Calibrate – Calibrate LED, password protected.

MULTIPLE UNIT POWER LINKING

With this feature you can connect the fixtures to one another using the power cable input and output sockets.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAXIMUM POWER OUTPUT ON THIS FIXTURE! CHECK SILK SCREEN FOR MAXIMUM AMPERES.

DIMMER MODE CHART

DMX TRAITS: CHANNEL FUNCTIONS & VALUES (1/2/3/6 DMX Channels)

Supports Software Versions: ≥ 1.07

Features subject to change without notice.
MODE/CHANNEL| VALUE| FUNCTION
1CH| 2CH| 3CH| 6CH
1| 1| 1| 1|  | Dimmer Intensity 8bit
000-255| 0 to 100%
 | 2| 2| 2| 000-255| Dimmer Fine 16bit
 |  |

3

|

3

|  | Shutter
000-031| Shutter Closed (LEDs OFF)
032-063| Shutter OPEN (LEDs ON)
064-095| Strobe effect slow to fast
096-127| Shutter OPEN (LEDs ON)
128-159| Pulse effect in sequences
160-191| Shutter OPEN (LEDs ON)
192-223| Random strobe effect slow to fast
224-255| Shutter OPEN (LEDs ON)
 |  |  |

4

|  | Dim Modes
000-020| Default to Unit Setting
021-040| Standard
041-060| Stage
061-080| TV
081-100| Architectural
101-120| Theatre
121-140| Stage 2
 | Dimming Speed
141| 0.1Sec.
142| 0.2Sec.
143| 0.3Sec.
144| 0.4Sec.
145| 0.5Sec.
146| 0.6Sec.
147| 0.7Sec.
148| 0.8Sec.
149| 0.9Sec.
150| 1.0Sec.
151| 1.5Sec.
152| 2.0Sec.
153| 3.0Sec.
154| 4.0Sec.
155| 5.0Sec.
156| 6.0Sec.
157| 7.0Sec.
158| 8.0Sec.
159| 9.0Sec.
160| 10Sec.
161-255| Default to Unit Setting
 |  |  |

5

|  | Dim Curves
000-020| Square
021-040| Linear
041-060| Inv. Squa
061-080| S. Curve
081-255| No Function
Supports Software Versions: ≥ 1.07

Features subject to change without notice.
MODE/CHANNEL| VALUE| FUNCTION
1CH| 2CH| 3CH| 6CH
 |  |  |

6

|  | LED Refresh Rates
000-028| 1200 HZ LED Refresh Rate (Default)
029-029| 1080 Hz LED Refresh Rate
030-030| 1090 Hz LED Refresh Rate
031-031| 1100 Hz LED Refresh Rate
032-032| 1110 Hz LED Refresh Rate
033-033| 1120 Hz LED Refresh Rate
034-034| 1130 Hz LED Refresh Rate
035-035| 1140 Hz LED Refresh Rate
036-036| 1150 Hz LED Refresh Rate
037-037| 1160 Hz LED Refresh Rate
038-038| 1170 Hz LED Refresh Rate
039-039| 1180 Hz LED Refresh Rate
040-040| 1190 Hz LED Refresh Rate
041-041| 1210 Hz LED Refresh Rate
042-042| 1220 Hz LED Refresh Rate
043-043| 1230 Hz LED Refresh Rate
044-044| 1240 Hz LED Refresh Rate
045-045| 1250 Hz LED Refresh Rate
046-046| 1260 Hz LED Refresh Rate
047-047| 1270 Hz LED Refresh Rate
048-048| 1280 Hz LED Refresh Rate
049-049| 1290 Hz LED Refresh Rate
050-050| 1300 Hz LED Refresh Rate
051-051| 1310 Hz LED Refresh Rate
052-052| 1320 Hz LED Refresh Rate
053-053| 1330 Hz LED Refresh Rate
054-054| 1340 Hz LED Refresh Rate
055-055| 1350 Hz LED Refresh Rate
056-056| 1360 Hz LED Refresh Rate
057-057| 1370 Hz LED Refresh Rate
058-058| 1380 Hz LED Refresh Rate
059-059| 1390 Hz LED Refresh Rate
060-060| 1400 Hz LED Refresh Rate
061-061| 1410 Hz LED Refresh Rate
062-062| 1420 Hz LED Refresh Rate
063-063| 1430 Hz LED Refresh Rate
064-064| 1440 Hz LED Refresh Rate
065-065| 1450 Hz LED Refresh Rate
066-066| 1460 Hz LED Refresh Rate
067-067| 1470 Hz LED Refresh Rate
068-068| 1480 Hz LED Refresh Rate
069-069| 1490 Hz LED Refresh Rate
070-070| 1500 Hz LED Refresh Rate
071-071| 2500 Hz LED Refresh Rate
072-072| 4000 Hz LED Refresh Rate
073-073| 5000 Hz LED Refresh Rate
074-074| 6000 Hz LED Refresh Rate
075-075| 10K Hz LED Refresh Rate
076-076| 15K Hz LED Refresh Rate
077-077| 20K Hz LED Refresh Rate
078-078| 25K Hz LED Refresh Rate
079-079| Disable LED Refresh Rate
080-255| No Function

SPECIFICATIONS

  • SOURCE

    • 260W Warm White LED Engine
    • 50,000 Hour Average LED Life*
    • *LED Life may vary depending on several factors including but not limited to:
    • Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.
  • PHOTOMETRIC DATA
    97CRI 10,000 Total Lumens (with 26° lens) 3200K Color Temperature

  • EFFECTS

    • Electronic Strobe and Dimming
    • Variable Dimming Curves and Dimming Modes
  • GOBOS

    • Supports “B” Size Metal, HT Transparency Gobos*
    • *Gobos and Holder not included.
  • CONTROL / CONNECTIONS

    • (4) DMX Channel Modes (1 / 2 / 3 / 4)
    • Adjustable Refresh Rates (900-1500, 25,000 Hz)
    • 4 Button Control Panel
    • LED Menu Display
    • Locking 5pin XLR Connector In/Out
    • Locking Power Connector In/Out
    • With Wired Digital Communication Network
  • SIZE / WEIGHT

    • Length: 26.9” (688mm) (Lens In)
    • Width: 111.3” (287mm)
    • Vertical Height: 17.7” (450mm)
    • Weight: 20.0 lbs. (9.1 kg)
  • ELECTRICAL / THERMAL

    • Quiet Fan Cooling
    • AC 100-240V – 50/60Hz
    • 295W Max Power Consumption
    • Power Linking: 3pcs Max @120V / 8pcs Max @240V
    • 14° to 113°F (-10° to 45°C)
    • BTU: 0.28
    • BTU/H: 1005.95
  • APPROVALS / RATINGS
    CE | cETLus (Pending) | IP20

  • INCLUDED ITEMS
    Locking Power Cable
    Specifications and documentation subject to change without notice.

DIMENSIONAL DRAWINGS

DIMENSIONAL DRAWINGS – OPTIONAL LENS KITS

TROUBLESHOOTING

Listed below are a few common problems the user may encounter, with solutions.

  • Unit not powered on:
    Check that the fixture is plugged in.

  • Unit not responding to DMX:
    Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right connectors; it does matter which way the inputs and outputs are connected.

CLEANING

  • Frequent cleaning is recommended to ensure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky, or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. Clean the external lens surface periodically with a soft cloth to avoid dirt/debris accumulation.
  • NEVER use alcohol, solvents, or ammonia-based cleaners.

MAINTENANCE

  • Regular inspections are recommended to ensure proper function and extended life.
  • There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized ADJ service technician. Should you need any spare parts, please order genuine parts from your local ADJ dealer.
  • Please refer to the following points during routine inspections:
    • A detailed electrical check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition in order to prevent overheating.
    • Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation, resulting in damage or injury as larger parts could fall.
    • Check for any deformations on the housing, color lenses, rigging hardware, and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust or liquids to enter into the fixture. Damaged rigging points or unsecured rigging could cause fixture to fall and seriously injure a person(s).
    • Electric power supply cables must not show any damage, material fatigue, or sediments.
    • NEVER remove the ground prong from the power cable.

OPTIONAL ACCESSORIES

SKU# Models
US EU
EPP IRIS PENDING
EPL140 PENDING
EPL166 PENDING
EPL190 1237000308
EPL260 1237000309
EPL360 1237000310
EPL500 1237000311
SIP064 PENDING
SIP113 PENDING
SIP126 PENDING
SIP139 PENDING
SIP152 PENDING
SIP165 PENDING
SIP178 PENDING
SIP191 PENDING

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

  • Reorient or relocate the device.
  • Increase the separation between the device and the receiver.
  • Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals