Product Specifications
- Product Name: 1200W Portable Power Station
- Product Model: G1200
- Total Charge Power: 1200W MAX
- Total Discharge Power: 1581W MAX
Product Usage Instructions
Charging Specifications
Ensure to follow the specific charging specifications for the G1200
Portable Power Station:
DC/DC & Solar Power Charge Specifications
- DC/DC Charge Voltage: 10Vdc – 50Vdc
- DC/DC Charge Protection: 53Vdc / 55Vdc / 57Vdc
- DC/DC Charge Current: Record the charge current values accordingly
- Solar Power Charge Current: Specify the MPPT power details
AC/AC Charge Specifications
- Charge Voltage: 110Vac – 130Vac
- Low Voltage Protection: 87Vac – 90Vac
- High Voltage Protection: 147Vac – 150Vac – 153Vac
- Charge Power: 1200W
- AC Charge Frequency: 44Hz – 60Hz
- Charge Power Factor: 0.9 – 1
- AC Charge Wave: Sine wave
Control Strategy of Charge (For Reference)
Detailed control strategies and power limitations for charging are outlined
in the manual. Refer to the manual for specific details.
Frequently Asked Questions (FAQ)
-
Q: Where can I find the charging specifications for the G1200?
A: The charging specifications are detailed in the product manual under the ‘Product Specification’ section. -
Q: What is the total charge power and discharge power of the G1200?
A: The G1200 has a total charge power of 1200W MAX and a total discharge power of 1581W MAX.
Customer: SOHO International Group Corporation
Product Specification of G1200
- Product Name:1200W Portable Power Station
- Product Model:G1200
- Customer P/N:
- Date:2024-09-13
Add: No.1,Yan’an Road Kuichong Dapeng New District Shenzhen, 518119,
P.R.China
TEL:+86-755-89888888
FAX: +86-755-84232333
http://www.byd.com.cn
Revision History
**** Edition | Content changed | Edit date |
---|---|---|
A-0 | First publish | 2024-09-13 |
Scope
Description
- Description:1200W
- Product model:G1200
- Total charge power:1200W MAX
- otal discharge power:1581W MAX
- Product photo:
Product Specification
Charge spec
DC DC/solar power charge spec
Item | Min | Rate | Max | Record |
---|---|---|---|---|
DC charge voltage | 10Vdc | / | 50Vdc | |
DC charge protection | 53Vdc | 55Vdc | 57Vdc | |
DC charge current | / | / | 8± |
0.5A
| 输入电压 charge voltage:10-16.5±
0.5V,23.5V-33V
solar power charge current
|
/
|
/
| 12±
0.5A
| Adjust charge current according
strength of solar:17-23.5±0.5V, 33V-55V
MPPT power| 400W±30W|
Item| Min| Rate| Max| **Record**
---|---|---|---|---
Charge voltage| 110Vac| 120Vac| 130Vac|
Low voltage protection| 87Vac| 90Vac| 93Vac|
High voltage protection| 147Vac| 150Vac| 153Vac|
Charge power| | | 1200W|
AC charge frequency| 44Hz| 60Hz| 66Hz|
Charge power factor| 0.9| | 1| Vin=100~120V@ac100% Load
AC charge wave| | | | Sine wave
Control strategy of charge Just for reference
BMS Power limitation from BMS
Tcell | Charge power limitation |
---|---|
[0℃,5℃] | ≤200W |
(5℃,20℃] | Charge power limitation is 200W at 5℃, it increase 56W per 1℃ |
increase
(20℃,40℃]| ≤1200W
(40℃,50℃]| Charge power limitation is 820W at 41℃, it decrease 67W per 1℃
increase before 48℃, then it remains 333W
Tcell
- Tcell means surface temperature of cell。
- SOC≤1%≤24V 120W
- Charge power limitation is 120W when SOC≤1% or battery voltage ≤24V。
- SOC 97%>28.2V 220W
- Charge power limitation is 220W when SOC≥97% and battery voltage >28.2V
Power limitation from INV
TINV | AC charge power |
---|---|
[0℃,68℃] | ≤1200W |
(68℃,73℃) | ≤860W |
[73℃,78℃) | ≤780W |
--- | --- |
[78℃,83℃) | ≤515W |
[83℃,92℃) | ≤250W,(92℃) |
Stop charge after trigger temperature protection。
Discharge specification
DC discharge spec
Discharge | Function |
---|---|
USB-A*2 | Discharge power |
Discharge protocol | APPLE2.4A、BC1.2 DCP、QC3.0、FCP、SCP、AFC。 |
USB-C*2 | Discharge power |
Discharge protocol | APPLE2.4A、SAMSUNG5V2A、QC3.0、QC2.0、PD3.0、PPS |
(3-11V3A/3-21V3A)、FCP、AFC、BC1.2。
Car port| Discharge spec| CC:12.9-14.3V/10A
CV:12V/10-13A
DC55212| Discharge spec| 13.6V/5A 2。
AC discharge spec
Item | Min | Rate | Max | Record |
---|---|---|---|---|
Discharge voltage | 110Vac | 120Vac | 130Vac | 100-120V。 |
Discharge power | 100W | 1200W | 1260W | |
U-turbo model power | – | – | 1260W | AC discharge power in U-turbo mode |
AC discharge frequency self-adaptation | 59Hz | 60Hz | 61Hz | Frequency>55Hz |
49Hz | 50Hz | 51Hz | Frequency≤55Hz | |
Discharge power factor | 0.95 | 1 | ||
AC discharge wave | Sine wave | |||
Conversion efficiency | 90% | / | / | |
Low voltage protection in U-turbo mode | 65V | 70V | 75V | When discharge current |
lower than 15A
Control strategy of discharge
Tcell | Power limitation |
---|---|
[-20℃,0℃) | ≤560W |
[0℃,10℃) | ≤1335W |
[10℃,50℃) | ≤1581W |
[50℃,60℃)* | ≤1200W |
Tcell means surface temperature of cell。
Product function
-
Power on: Click ON/OFF button, Other buttons are valid only after power-on
-
Standard mode: Default mode after power on, and automatically enter standard mode after exit standard always-on mode, power saving mode and forced discharge mode. In this mode, power off after small current detection time is 1 h and then no equipment connected for 4 h, but time will be reset if there is equipment connected. Power off after fault lasts 1 minute.
-
Standard always-on mode
Description: In this mode, the AC port and DC port (each function of the product) will remain open until the low battery shutdown or manual power off. Product will enter standard mode after next Power on.- Turn on: Press DC button for 3s
- Turn off: Press DC button for 3s or power off
-
Description: In this mode, the AC port and DC port (each function of the product) will remain open until the low battery shutdown or manual turn . Product will enter this mode after next Power on.
- Turn on: Press AC button for 3s
- Turn off: Press AC button for 3s or power off
-
Force discharge mode
- Description: Decrease low voltage protection for the use with USB-A/C and light.
- Turn on: Press both the DC button and LED button for 10s when SOC is 0%
- Turn off: Power off, charge or press the DC button for 10s
-
Power saving mode
- Description: Function that has not been used for a certain time will be automatically turned off: AC port small current detection for 1 h; DC port small current detection for 1 h. In the standby mode, product will automatically power off if no equipment is connected for 2 h. This function retained in the next power on.
- Turn on: Double click the ON/OFF button.
- Turn off: Double click the ON/OFF button.z
-
Discharge when charging: Product support AC and DC discharge when charging
-
U-turbo mode: Working with purely resistive loads lager than the rated power is supported by reducing the voltage.
-
Light
- Turn on: In the off state, click the LED button to start the cycle of “weak -strong -flash -SOS-off”.
- Turn off: Press the LED button for 3s in any mode that is turned on.
-
Shipment mode
- Description: Factory mode, to avoid power consumption caused by accidental touch during transportation.
- Turn on: Press all the three buttons (IOT button + LED button + DC button) together for 10s.
- Turn off: Charge.
-
Atmosphere lamp
- Turn on: Always on after power on, breathing when charging。
- Turn off: Double click mute button
-
Quiet mode
- Description: Reduce the heat and control the fan not to rotate as much as possible by reducing charging power, but increase charge time.
- Turn on/off: Click mute button
Display Screen