ICON TVE Series Level Display and Controller User Guide
- September 24, 2024
- Icon
Table of Contents
- ICON TVE Series Level Display and Controller
- Product Usage Instructions
- Symbol Explanation
- Basic Requirements | User Safety
- Specifications
- Front Panel Description
- Function of Push Buttons
- Dimensions
- Power Supply & Relay Connection
- Flow Meter Connections (Relay Type)
- Programming K Factor
- Programming Batching
- Resetting Batch
- Warranty, Returns and Limitations
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ICON TVE Series Level Display and Controller
Specifications
General
- Display: LED | 6 Digit | 13mm High | Red | Adjustable Brightness
- Displayed Values: 0 ~ 999999
- RS485 Transmission: 1200…115200 bit/s, 8N1 / 8N2
- Housing Material: Polycarbonate
- Protection Class: NEMA 4X | IP67
Input Signal | Supply
- Standard Voltage: 85 – 260V AC/DC | 16 – 35V AC, 19 – 50V DC*
Output Signal | Supply
- 2 x Relays (5A) | 1 x Relay (5A) + 4-20mA RS485
- Standard Communication Voltage: 24VDC
Performance
- Accuracy:
- Temperatures: Operating Temperature *Optional
Product Usage Instructions
User Safety Guidelines
- Do not use the unit in areas threatened with excessive shocks, vibrations, dust, humidity, corrosive gasses, and oils.
- Do not use the unit in areas where there is a risk of explosions.
- Do not use the unit in areas with significant temperature variations, exposure to condensation or ice.
Installation and Operation
- Switch off and disconnect the unit from the power supply before installation or troubleshooting.Avoid disassembling, repairing, or modifying the unit yourself as it contains dangerous voltage.
- Defective units must be submitted for repairs at an authorized service center.
Front Panel Description
- Relay LED Indicator for Relay 1 & 2
- SunBright LED Display with 8 Levels of Brightness
- Flow | Batching Mode LED Indicator
- Push Button Programming with functions like ENTER, PAUSE, RESET
Symbol Explanation
This symbol denotes especially important guidelines concerning the installation and operation of the device. Not complying with the guidelines denoted by this symbol may cause an accident, damage or equipment destruction.
Basic Requirements | User Safety
- Do not use the unit in areas threatened with excessive shocks, vibrations, dust, humidity, corrosive gasses and oils.
- Do not use the unit in areas where there is risk of explosions.
- Do not use the unit in areas with significant temperature variations, exposure to condensation or ice.
- The manufacturer is not responsible for any damages caused by inappropriate installation, not maintaining the proper environmental conditions and using the unit contrary to its assignment.
- If in the case of a unit malfunction there is a risk of a serious threat to the safety of people or property additional, independent systems and solutions to prevent such a threat must be used.
- The unit uses dangerous voltage that can cause a lethal accident. The unit must be switched off and disconnected from the power supply prior to starting installation of troubleshooting (in the case of malfunction).
- Do not attempt to disassemble, repair or modify the unit yourself. The unit has no user serviceable parts.
- Defective units must be disconnected and submitted for repairs at an authorized service center.
Specifications
General
Display| LED | 6 Digit | 13mm High | Red | Adjustable Brightness
Displayed Values| 0 ~ 999999
RS485 Transmission| 1200…115200 bit/s, 8N1 / 8N2
Housing Material| Polycarbonate
Protection Class| NEMA 4X | IP67
Input Signal | Supply
Standard| Current: 4-20mA | 0-20mA | 0-5V | 0-10V
Voltage| 85 – 260V AC/DC | 16 – 35V AC, 19 – 50V DC
Output Signal | Supply
Standard| 2 x Relays (5A) | 1 x Relay (5A) + 4-20mA
Communication| RS485
Voltage| 24VDC
Passive current output | 4-20mA | (Operating Range Max. 2.8 – 24mA)
Performance
Accuracy| 0.1% @ 25°C One Digit
Temperatures
Operating Temperature| -40 – 158°F | -40 – 70°C
Front Panel Description
Function of Push Buttons
Dimensions
Wiring Diagram
Due to possible significant interference in industrial installations,
appropriate measures assuring correct operation of the unit must be applied.
The unit is not equipped with an internal fuse or power supply circuit
breaker.
For this reason, an external time-delay cut-out fuse with a small nominal
current value must be used (recommended bipolar, max. 2A) and a power supply
circuit breaker located near the unit.
Power Supply & Relay Connection
Contacts of relay outputs are not equipped with spark suppressors. When using the relay outputs for switching of inductive loads (coils, contactors, power relays, electromagnets, motors etc.) it is required to use additional suppression circuit (typically capacitor 47nF/ min. 250VAC in series with 100R/5W resistor), connected in parallel to relay terminals or (better) directly on the load.
Suppression Circuit Connection
Figure: Examples of Suppression Circuit Connection a) To Stepper Relay Terminals b) To the Inductive Load (Motor)
OC-Type Output Connection
Current Output Connection Using Internal Power Supply
Flow Meter Connections (Relay Type)
TKM Series : 4-20mA Output
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
11| Yellow| mA+
12| Grey| mA-
TKS Series : Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| Black| NPN Pulse
Jump 13 & 8
TKW Series : Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| Black| Pulse
Jump 13 & 8
TKW Series : 4-20mA Output
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
11| Black| mA+
12| White| mA-
Programming K Factor
Programming Relays
Programming Batching
Programming Output (For 4-20mA Output Models)
Resetting Batch
Resetting Totalizer
Setting Decimal Point
Warranty, Returns and Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its
products that such products will be free from defects in material and
workmanship under normal use and service in accordance with instructions
furnished by Icon Process Controls Ltd for a period of one year from the date
of sale of such products. Icon Process Controls Ltd obligation under this
warranty is solely and exclusively limited to the repair or replacement, at
Icon Process Controls Ltd option, of the products or components, which Icon
Process Controls Ltd examination determines to its satisfaction to be
defective in material or workmanship within the warranty period. Icon Process
Controls Ltd must be notified pursuant to the instructions below of any claim
under this warranty within thirty (30) days of any claimed lack of conformity
of the product. Any product repaired under this warranty will be warranted
only for the remainder of the original warranty period. Any product provided
as a replacement under this warranty will be warranted for the one year from
the date of replacement.
Returns
Products cannot be returned to Icon Process Controls Ltd without prior
authorization. To return a product that is thought to be defective, go to
www.iconprocon.com, and submit a customer return
(MRA) request form and follow the instructions therein. All warranty and non-
warranty product returns to Icon Process Controls Ltd must be shipped prepaid
and insured. Icon Process Controls Ltd will not be responsible for any
products lost or damaged in shipment.
Limitations
- This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada.
- If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.
For additional product documentation and technical support visit:
www.iconprocon.com | e-mail: sales@iconprocon.com or support@iconprocon.com | Ph: 905.469.9283
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>