TSUNESS TSOL-MG3-MP Micro Inverter User Manual
- September 22, 2024
- TSUNESS
Table of Contents
TSOL-MG3-MP Micro Inverter
Specifications
Product Name: TSOL-MG3-MP
Version: V1.0
Manufacturer: TSUNESS Co., Ltd
Intended Users: Professional installation and maintenance
personnel
Product Description
The TSOL-MG3-MP is a product developed by TSUNESS Co., Ltd. It
is designed for specific use by professional installation and
maintenance personnel. The product is subject to change without
notice, and users are advised to refer to the manufacturer’s
website for the latest information.
System Introduction
The TSOL-MG3-MP is a versatile system that offers various
features for efficient installation and maintenance tasks. It is
essential to follow the provided instructions carefully to ensure
optimal reliability and meet warranty requirements.
Installation
Pre-installation Check
Before initiating the installation process, perform a thorough
pre-installation check to ensure all necessary components are
available and in good condition. Verify that all safety precautions
are in place to prevent any accidents during installation.
Installation Steps
Follow the step-by-step installation guide provided in this
manual to successfully install the TSOL-MG3-MP system. Make sure to
adhere to all guidelines and recommendations specified by the
manufacturer for optimal performance.
FAQ
Q: Can the TSOL-MG3-MP be used by non-professionals?
A: The TSOL-MG3-MP is specifically designed for professional
installation and maintenance personnel. It is recommended to seek
assistance from trained individuals to ensure proper usage and
performance.
Q: How often should the product documentation be checked for
updates?
A: It is advisable to regularly visit www.tsun-ess.com to access
the latest product information and updates regarding the
TSOL-MG3-MP system. Regularly updating the documentation ensures
that you have access to the most recent guidelines and
recommendations for product usage.
TSOL-MG3-MP
TSOL-MG3-MP
V1.0
– 1 –
TSOL-MG3-MP
Trademarks and Permissions
TSUN and other TSUNESS trademarks are trademarks of TSUNESS Co., Ltd. All
other trademarks and trade names mentioned in this document are the property
of their respective holders.
TSUNESS Co., Ltd makes no representations express or implied, concerning this
documentation or any of the equipment and/or software it may describe,
including (with no limitation) any implied warranties of utility,
merchantability, or fitness for any particular purpose.
All such warranties are expressly disclaimed. Neither TSUNESS nor its
distributors or dealers shall be liable for any indirect, incidental, or
consequential damages under any circumstances. (The exclusion of implied
warranties may not apply in all cases under some statutes, and thus the above
exclusion may not apply.)
Specifications are subject to change without notice. Every attempt has been
made to make this document complete, accurate, and up-to-date. Readers are
cautioned, however, that TSUNESS reserves the right to make changes without
notice and shall not be responsible for any damages, including indirect,
incidental, or consequential damages, caused by reliance on the material
presented, including, but not limited to, omissions, typographical errors,
arithmetical errors or listing errors in the content material.
All trademarks are recognized even if these are not marked separately. Missing
designations do not mean product or brand is not a registered trademark. All
trademarks are recognized as the property of their respective owners.
Product information is subject to change without notice. User documentation is
frequently updated; please check www.tsun-ess.com for the latest information.
To ensure optimal reliability and meet warranty requirements, TSUN products
must be installed according to the instructions in this manual. For warranty
text refer to www.tsun-ess.com.
© 2023 TSUNESS Co., Ltd All rights reserved.
Audience
This manual is intended for use by professional installation and maintenance
personnel.
V1.0
– 2 –
TSOL-MG3-MP
Content
Trademarks and Permissions …………………………………………………………………………………………………………………………..- 1
Audience………………………………………………………………………………………………………………………………………………………- 2
Content…………………………………………………………………………………………………………………………………………………………- 3 Read This
First………………………………………………………………………………………………………………………………………………- 4 –
Important Safety Information
………………………………………………………………………………………………………………………………………………….. – 4 Product
Label………………………………………………………………………………………………………………………………………………………………………… – 4 –
System Introduction……………………………………………………………………………………………………………………………………….- 5 –
Product Description
……………………………………………………………………………………………………………………………………………………………….. – 6 Datasheet
……………………………………………………………………………………………………………………………………………………………………………… – 7 –
Installation ……………………………………………………………………………………………………………………………………………………- 8 –
Pre-installation Check
……………………………………………………………………………………………………………………………………………………………. – 8 Installation
Steps …………………………………………………………………………………………………………………………………………………………………… – 8 –
Maintenance Guide ………………………………………………………………………………………………………………………………………- 16 –
Routine
Maintenance……………………………………………………………………………………………………………………………………………………………. – 16
Storage and Dismantling
………………………………………………………………………………………………………………………………………………………. – 16 –
Recycling and Disposal ………………………………………………………………………………………………………………………………..- 17
Warranty Service………………………………………………………………………………………………………………………………………….- 17 –
Exclusions…………………………………………………………………………………………………………………………………………………………………………… –
17 Distributor Responsibility
…………………………………………………………………………………………………………………………………………………….. – 18 –
Annex I: SunSpec Modbus Profile V1.2………………………………………………………………………………………………………….-
19 –
V1.0
– 3 –
TSOL-MG3-MP
Read This First
Dear customer, thank you for choosing TSUN products. We hope you will find our
products meet your needs for renewable energy. Meantime, we appreciate your
feedback regarding our products.
Data Transfer Unit (DTU) is a communication device for the TSUN RS485
microinverter system. This manual contains important instructions for TSOL-
MG3-MP DTU and must be read in its entirety before installing or commissioning
the equipment. For safety, only qualified technicians, who have received
training or have demonstrated skills can install and maintain this DTU under
the guide of this document.
Important Safety Information
During installation, testing, and inspection, adherence to all the handling
and safety instructions is mandatory. Failure to do so may result in injury or
loss of life and damage to the equipment.
Product Label
The symbols on the products are listed below and illustrated in detail.
Symbol
Description
This device fulfills the requirements of the Radio Equipment Directive.
This device complies with the RoHS Directive.
Please read the installation manual first before installation, operation, and
maintenance.
This device SHALL NOT be disposed of in residential waste.
V1.0
– 4 –
TSOL-MG3-MP
System Introduction
The TSOL-MG3-MP DTU is used in grid-tied applications which is comprised of
three key elements:
TSUN RS485 Microinverter. TSOL-MG3-MP DTU. Monitoring System: TSUN Portal
Website and TSUN Smart APP . The microinverter converts the DC electricity
generated by solar panels into AC electricity which is in accordance with the
requirements of the public grid and sends the AC into the grid, reducing the
load pressure of the grid.
DTU and microinverters are all connected by RS485 cables. DTU can collect the
operating data of microinverters and send control command to each
microinverter. DTU has an Ethernet port and an integrated WiFi module. DTU can
communicate with the network switch or router by Ethernet cable or WiFi. Users
can monitor the power generation of the system by TSUN Smart App and TSUN
Portal Website.
DTU can also connect to electricity meter devices, collect power grid
information, and control the output power of the photovoltaic system to
achieve zero-export function.
DTU also has an external communication interface, which can receive external dispatch commands and regulate output power of the system.
V1.0
– 5 –
Product Description
TSOL-MG3-MP
Object
Description
Object
Description
A
Power LED
E Communication LED (Dispatch)
B
Communication LED (Inverter)
F
Communication LED (Router)
C
Communication LED (Meter)
G*
SIM Card Slot (Reserve)
D
Alarm LED
- These ports are reserved. Pls contact TSUN for more details if you need.
Object
Description
Object
Description
H*
4G Antenna (Reserve)
L
Ethernet Port
I
RS485 Port (Inverter)
M
Reset Hole
J RS485 Port (Dispatch/Meter/Debug) N
Power Port
K*
DRM Port (Reserve)
O
WiFi Antenna
- These ports are reserved. Pls contact TSUN for more details if you need.
V1.0
– 6 –
TSOL-MG3-MP
Datasheet
Model Communication to MicroinverterRS485 Communication port Maximum Distance
Baud Rate Connection Limit Communication to MeterRS485 Communication port
Maximum Distance Grid Type Baud Rate Communication to Server (WiFi or
Ethernet) Communication port WiFi Signal WiFi Frequency Maximum
DistanceWiFi(Open Space)
Ethernet Port Ethernet Speed Maximum DistanceEthernet Sample Rate
Communication to App Signal BLE Frequency Maximum Distance to mobile phone
(Open Space) Power Supply Type Input Voltage/Frequency Power Consumption
Mechanical Data Ambient Temperature Mounting System Indicator Light
Communication Port Dimension Weight Protection
TSOL-MG3-MP
RS485 500m 9600 bps 64 Microinverters
RS485 100m Single phase / Three phase 9600 bps 4800 to 19200 optional
WiFi / Ethernet WIFI (802.11 b/g/n)
2.4GHz 100m RJ45802.3 10/100M Base-T 500m Per 5 minutes
Bluetooth 5.0 2.4GHz 50m
External adapter 100 to 240V AC / 50 or 60Hz 2.5W(typical), 5W(maximum)
-20 ~ +55 °C Wall mounted
6LED 5RS485, 2RJ45(DRM,Enthernet)
200 100 * 29 mm 232g IP20
TSUNESS Co., Ltd declares that the radio equipment (DTU) is in complies with Directive 2014/53/EU. OPERATING FREQUENCY (the maximum transmitted power) 2412MHz–2472MHz(EIRP 20dBm) 2402MHz–2480MHz(EIRP 10dBm)
V1.0
– 7 –
Installation
Pre-installation Check
Check the Package
TSOL-MG3-MP
DTU * 1
Antenna * 1
Adaptor * 1
Bracket * 1
Expansion Screw * 4
User Manual * 1
Check the Installation Environment and Position
When choosing the position of installation, comply with the following
conditions: Avoid electromagnetic interference that can compromise the correct
operation of electronic
equipment. An AC power source is needed while doing the installation.
Installation Steps
Step 1. (Optional) Install the WiFi Antenna.
Take the antenna out from the box, screw the antenna into the Wi-Fi port.
V1.0
– 8 –
TSOL-MG3-MP
Step 2. Install the bracket and fix the DTU Use at least two screw holes (one
from each side) to fix the bracket (the M4 screws need to be prepared by
installer).
Match the bracket’s upper buckle with monitor device. Then match the bracket’s
lower buckle by gently press the lower side of the monitor device until hear
the “Click”.
Step 3. Connect the RS485 port (Inverter) Connect the RS485 Port (inverter) A1 and B1 to the microinverters.
V1.0
– 9 –
TSOL-MG3-MP
The definition of microinverter RS485 connector can be found in the Quick
Installation Guide or User Manual of TSUN RS485 microinverter.
Step 4. Connect the Ethernet port
Connect the Ethernet Port to the WiFi router or network switch. Step 5. (Optional) Connect the Meter port
Connect the RS485 Port (Meter) A3 and B3 to the power meter.
V1.0
– 10 –
Step 6. (Optional) Connect the Dispatch port
TSOL-MG3-MP
Connect the RS485 Port (Dispatch) A2 and B2 to the power control device.
More information can be found in Annex I SunSpec Modbus Profile V1.2.
Step 7. Power on the DTU Power on the DTU. Step 8. Finish the installation of
microinverter Finish the installation of microinverters. Step 9. Register in
TSUN Portal Website Visit pro.talent-monitoring.com and register as an
installer.
Step 10. Create a solar plant and add DTU device. Create a new plant and
finish the plant detail.
Tips: The system type must be set to “solar + grid + consumption”
V1.0
– 11 –
Add the SN of DTU.
TSOL-MG3-MP
Tips: The 10-digts SN can be found in the backside of DTU.
V1.0
– 12 –
TSOL-MG3-MP
Step 11. Create an end-user account and authorize the solar plant. Create an
end-user account and finish the details.Authorize the solar plant to this end-
user account.
Step 12. Config the DTU.
Click
button in “Device List” page to configure DTU.
V1.0
– 13 –
TSOL-MG3-MP
Download template and fill in the SN and phase relationship in the template.
V1.0
– 14 –
TSOL-MG3-MP
Upload the module version and complete the configuration.
Step 13. Download the website.
Download “TSUN Smart” APP in Google Play or Apple Store. End user can visit
this solar plant by TSUN Smart.
V1.0
– 15 –
TSOL-MG3-MP
Maintenance Guide
Routine Maintenance
Only authorized personnel are allowed to carry out the maintenance operations
and are responsible for reporting any anomalies.
Always use the personal protective equipment provided by the employer when
carrying out maintenance.
During normal operation, check that the environmental and logistic conditions
are appropriate. Make sure that the conditions have not changed over time and
that the equipment is not exposed to adverse weather conditions and has not
been covered with foreign bodies.
DO NOT use the equipment if any problems are found and restore the normal
conditions after the fault has been corrected.
The firmware version can be checked by using the monitoring system. Do not
attempt to dismantle the DTU or make any internal repairs! To preserve the
integrity of
safety and insulation, the DTU is not designed to allow internal repairs!
Avoid temporary repairs. All repairs should be carried out using only genuine
spare parts.
Storage and Dismantling
If the equipment is not used immediately or is stored for long periods, check
whether it is correctly packed. The equipment must be stored in well-
ventilated indoor areas that do not have characteristics that might damage the
components of the equipment.
Take a complete inspection when restarting after a long time or prolonged
stop. Please dispose of the equipment properly after scrapping, as component
parts are potentially
harmful to the environment, following the regulations in force in the country
of installation.
V1.0
– 16 –
TSOL-MG3-MP
Recycling and Disposal
This device should not be disposed of as residential waste. A DTU that has
reached the end of its life is not required to be returned to the dealer.
Users must find an approved collection and recycling facility in the area.
Warranty Service
This Warranty is subject to the following conditions: The products must have
been installed and correctly commissioned by an authorized and
licensed installer. Proof may be required of correct commissioning of the
Product (such as a certificate of compliance). Claims for failures due to
incorrect installation or commissioning are not covered under this Warranty.
Where a Product or part thereof is replaced or repaired under this Warranty,
the balance of the original Warranty period will apply. The replacement
product or part(s) do not carry a new voluntary warranty. The product must
have its original serial number and rating labels intact and readable. This
Warranty does not extend to any product that has been completely or partially
disassembled or modified, except where such disassembly is carried out by
TSUNESS The terms of this Warranty cannot be amended except in writing by one
of our authorized officers. There must have been a commissioning report signed
by the end user and the installer for product commissioning and handling
instructions.
Exclusions
(a) TSUNESS makes no warranties, either expressed or implied, orally, or in
writing, concerning any other warranty coverage except those expressly stated
in this limited Factory Warranty.
(b) The Factory Warranty does not cover damages that occur due to: Transport
damage; Installation or commissioning through any person who is not an
Authorized, Certified Dealer; Failure to observe the user manual, maintenance
regulations, and intervals; Modifications, changes, or attempted repairs,
except as conducted by an Authorized Dealer; Incorrect use or inappropriate
operation; Failure to observe the applicable safety regulations; Force
majeure.
(c) This factory warranty does not cover cosmetic defects which do not
directly influence energy production, or degrade form, fit, and function.
(d) Claims that go beyond the scope of this limited Factory Warranty, in
particular claims for compensation for direct or indirect damages arising from
the defective device, for compensation for
V1.0
– 17 –
TSOL-MG3-MP
costs arising from disassembly and installation, or loss of profits, are
expressly NOT covered by this Factory Warranty. (e) In no event will TSUNESS
Co., Ltd be held responsible or liable for any personal injuries resulting
from the use of the system, or for any other damages, whether direct,
indirect, incidental, or consequential; even if TSUNESS Co., Ltd has been
advised of such damages.
Distributor Responsibility
In the event of an equipment failure or fault, it is the Distributor’s
responsibility to work directly with the TSUNESS Service Centre to limit the
return of non-faulty equipment. TSUNESS Service Centre will work with the
Distributor to rectify the fault or fault message through telephone support or
with direct PC links. Note: To qualify for further compensation and a
replacement unit, the distributor/installer must first contact TSUNESS and
fulfill the distributor’s /installer’s responsibilities under instruction.
Within the warranty period of the DTU, the invoice and date of purchase are
required for the service. Besides, the trademark on the product should be
visible, otherwise, a warranty is not available. More information can be found
in TSUN Warranty Policy.
V1.0
– 18 –
TSOL-MG3-MP
Annex I: SunSpec Modbus Profile V1.2
Modbus Register Number
40001
40003 40004
40005
40021 40037 40045 40053 40069 40344 40345
SunSpec-Name Description / Number code(s)
Type Access Remark
A well-known value 0x53756e53. Uniquely
SID
identifies this as a SunSpec Modbus Map:
uint32 RO
1400204883
A well-known value 1. Uniquely identifies this as a
ID
uint16 RO
SunSpec Common Model
L
Well-known # of 16 bit registers to follow : 66
uint16 RO
Well known value registered with SunSpec for
Mn
compliance:
string16 RO
SMA
Manufacturer specific value (32 chars): Md
Solar Inverter
string16 RO
Opt
Manufacturer specific value (16 chars): Model ID
string8 RO
Vr
Manufacturer specific value (16 chars)
string8 RO
SN
Manufacturer specific value (32 chars)
string16 RO
DA
modbus device address
uint16 RW
A well-known value 123. Uniquely identifies this as
ID
uint16 RO
a SunSpec Immediate Controls Model
L
Well-known # of 16 bit registers to follow : 24
uint16 RO
40348 40349 40353 40359
Conn
Enumerated valued. Connection control
uint16 RW
WMaxLimPct Set power output to specified level
uint16 RW
Enumerated valued. Throttle enable/disable control:
WMaxLim_Ena 0
uint16 RW
VArWMaxPct Reactive power in percent of WMax
int16 RW
40365
VArPct_Mod Enumerated value. VAR percent limit mode
uint16 RW
Enumerated valued. Percent limit VAr
enable/disable control:
40366
VArPct_Ena 0
1Adder 1
2Standard Modbus Protocol
396008bit, No parity bit, 1bit Stopbit
uint16 RW
0-100 (0-100%) 0:disable 1:enable
0-100 (0-100%) 0x99 QPLeading 0x9A QPLagging
0:disable 1:enable
V1.0
– 19 –
TSOL-MG3-MP
V1.0
– 20 –