FAQ:
Q: How do I change the batteries in the remote control?
A: Slide the back cover downward to access the battery compartment, insert batteries matching the correct alignment, and slide the cover back into place.
Q: What should I do if the remote control is not working?
A: Check the battery alignment, replace batteries if needed, and ensure there are no obstructions between the remote and the unit.
Models Covered:
- EZ-09W-M
- EZ-12WPL-HP115
- EZ-12W-M
- EZ-18W-M
- EZ-24W-M
- EZ-36W-M
IMPORTANT NOTE
Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.
VERSION DATE: 04-27-24
Remote Controller Specifications
Model
| RG10B(D)/BGEF, RG10B(D1)/BGEFU1, RG10B1(D)/BGEF, RG10B2(D)/BGCEF,
RG10B10(D)/BGEF, RG10A4(D)/BGEF, RG10A4(D1)/BGEFU1, RG10A5(D)/BGEF,
RG10A5(D1)/BGEFU1, RG10A5(D1)/BGCEFU1, RG10A5(D)/BGCEF, RG10A11(D)/BGEF,
---|---
Rated Voltage| 3.0V( Dry batteries R03/LR03×2)
Signal Receiving Range| 8m
Environment| -5°C~60°C(23°F~140°F)
Quick Start Guide
NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions
sections of this manual for a detailed description of how to use your air
conditioner.
SPECIAL NOTE
- Button designs on your unit may differ slightly from the example shown.
- If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
- When there are wide differences between “Remote controller Manual” and “USER’S MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use.
- Slide the back cover from the remote control downward, exposing the battery compartment.
- Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
Remote Control
- Direct sunlight can interfere with the infrared signal receiver.
- There must be a clear line of sight between the remote and the appliance.
- If the signals from the remote control happen to control another appliance, move the appliance to another location or contact customer service.
Battery Disposal
- Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
- Batteries may have a chemical symbol at the bottom of the disposal icon. This chemical symbol means that the battery contains a heavy metal that exceeds a certain concentration. An example is Pb: Lead (>0.004%). Appliances and used batteries must be treated in a specialized facility for reuse, recycling and recovery. By ensuring correct disposal, you will help avoid possible negative consequences for the environment and human health.
Battery Performance
For optimal product performance:
- Do not mix old and new batteries, or batteries of different brands.
- Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.
Notes For Using Remote Control
The device could comply with the local national regulations.
In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
In USA, this device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment
Buttons and Functions
Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.
Model: RG10B(D)/BGEF & RG10B(D1)/BGEFU1(Fresh feature is not available)
RG10B2(D)/BGCEF (Cooling only models, AUTO mode and HEAT mode
are not available)
RG10B10(D)/BGEF(20-28 O C).
NOTE: For RG10B(D1)/BGEFU1 model, press together buttons at the same time for 3 seconds will alternate the temperature display between the °C & °F scale.
Model: RG10B1(D)/BGEF
Model:
RG10A4(D)/BGEF, RG10A4(D1)/BGEFU1, RG10A5(D)/BGEF, RG10A5(D1)/BGEFU1
RG10A5(D)/BGCEF & RG10A5(D1)/BGCEFU1(Cooling only models,
AUTO mode and HEAT mode are not available), RG10A11(D)/BGEF(20-28 C).O
NOTE: For models of RG10A4(D1)/BGEFU1, RG10A5(D1)/BGEFU1 and
RG10A5(D1)/BGCEFU1, press together & buttons at the same time for 3 seconds
will alternate the temperature display between the scale. Fresh feature is not
available for models of
RG10A4(D)/BGEF and RG10A4(D1)/BGEFU1.
Remote Screen Indicators
Information are displayed when the remote controller is power up.
Note:
All indicators shown in the figure are for the purpose of clear presentation.
But during the actual operation, only the relative function signs are shown on
the display window.
How to Use Basic Functions
Basic operation
ATTENTION! Before operation, please ensure the unit is plugged in and power is available.
COOL Mode
-
1. Press the MODE button to select COOL
mode -
Set your desired temperature using the
button. -
Press FAN button to select the fan speed:
AUTO, LOW, MED or HIGH. -
Press the ON/OFF button to start the unit.
SETTING TEMPERATURE
The operating temperature range for units is 17-30°C (62-86°F)/20-28 C.
You can increase or decrease the set temperature in 1°C (1°F) increments.
AUTO Mode
In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT operation based on the set temperature.
- Press the MODE button to select AUTO.
- Set your desired temperature using the button.
- Press the ON/OFF button to start the unit.
NOTE: FAN SPEED can’t be set in AUTO mode.
FAN Mode
-
Press the MODE button to select FAN mode.
-
Press FAN button to select the fan speed:
AUTO, LOW, MED or HIGH. -
Press the ON/OFF button to start the unit.
NOTE: You can’t set temperature in FAN mode. As a result, your remote control’s LCD screen will not display temperature.
DRY Mode (dehumidifying)
- Press the MODE button to select DRY.
- Set your desired temperature using the button.
- Press the ON/OFF button to start the unit.
NOTE: FAN SPEED cannot be changed in DRY mode.
HEAT Mode
- Press the MODE button to select HEAT mode.
- Set your desired temperature using the button.
- Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
- Press the ON/OFF button to start the unit.
NOTE: As outdoor temperature drops, the performance of your unit’s HEAT function may be affected. In such instances, we recommend using this air conditioner in conjunction with other heating appliances.
Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.
TIMER ON setting
- Press TIMER button to initiate the ON time sequence.
- Press Temp. up or down button for for multiple times to set the desired time to turn on the unit.
- Point remote to unit and wait 1sec, the TIMER ON will be activated.
TIMER OFF setting
- Press TIMER button to initiate the OFF time sequence.
- Press Temp. up or down button for for multiple times to set the desired time to turn off the unit.
- Point remote to unit and wait 1sec, the TIMER OFF will be activated.
NOTE:
- When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
- Cancel either function by setting its timer to 0.0h.
TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours
after the current time.
Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.
How to Use Advanced Functions
Swing function
Press Swing button
- The horizontal louver will swing up and down automatically when pressing Swing button. Press again to make it stop.
- Keep pressing this button more than 2 seconds, the vertical louver swing function is activated. (Model dependent)
LED DISPLAY
- Press this button to turn on and turn off the display on the indoor unit.
- Keep pressing this button more than 5 seconds, the indoor unit will display the actual room temperature. Press more than 5 seconds again will revert back to display the setting temperature.
Silence function
Keep pressing Fan button for more than 2 seconds to activate/disable Silence
function(some units).
Due to low frequency operation of compressor, it may result in insufficient
cooling and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button
while operating will cancel silence function.
ECO function
Press ECO button(some units)
Press ECO button to enter the energy efficient mode. Note:This function is only available under COOL mode.
ECO operation:
Under cooling mode, press this button, the remote controller will adjust the
temperature Oautomatically to 24 C/75 F, fan speed of Auto to save energy
(only when the set temperature Ois less than 24 C/75 F). If the set
temperature is above 24 C/75 F, press the ECO button,O O the fan speed will
change to Auto, the set temperature will remain unchanged.
NOTE:
Pressing the ECO button, or modifying the mode or adjusting the set
temperature to less Othan 24 C/75 F will stop ECO operation.
Under ECO operation, the set tmeperature should be 24 C/75 F or above, it may
result inO O insufficient cooling. If you feel uncomfortable, just press the
ECO button again to stop it.
FP function
The unit will operate at high fan speed (while compressor on) with temperature automatically set to 8 C/46 F.
Note: This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting
temperature of 17 C/62 F or 20 C/68 F(for models RG10B10(D)/BGEF,
RG10A11(D)/BGEF) to activate FP function.
Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel
this function.
LOCK function
Press together Clean button and Turbo button at the same time more than 5 seconds to activate Lock function. All buttons will not response except pressing these two buttons for two seconds again to disable locking.
SHORTCUT function
Press SHORTCUT button(some units)
Push this button when remote controller is on, the system will automatically
revert back to the previous settings including operating mode, setting
temperature, fan speed level and sleep feature (if activated).
If pushing more than 2 seconds, the system will automatically restore the
current operation settings including operating mode, setting temperature, fan
speed level and sleep feature (if activated ).
Clean Function
Press Clean button
Airborne bacteria can grow in the moisture that condenses around heat
exchanger in the unit. With regular use, most of this moisture is evaporated
from the unit.
By pressing the CLEAN button, your unit will clean itself automatically. After
cleaning, the unit will turn off automatically. Pressing the CLEAN button mid-
cycle will cancel the operation and turn off the unit. You can use CLEAN as
often as you like.
Note: You can only activate this function in COOL or DRY mode.
TURBO Function
Press Turbo button
When you select Turbo feature in COOL mode, the unit will blow cool air with
strongest wind setting to jump-start the cooling process.
When you select Turbo feature in HEAT mode, the unit will blow heat air with
strongest wind setting to jump-start the heating process(some units). For
units with Electrical heat elements, the Electrical HEATER will activate and
jump-start the heating process.
SET function
- Press the SET button to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm.
- To cancel the selected function, just perform the same procedures as above.
- Press the SET button to scroll through operation functions as follows:
- If your remote controller has Fresh and Sleep button, you can not use the SET button to select the Fresh/UV-C lamp and Sleep feature.
FRESH/UV-C lamp function (some units) :
When this function is selected, the Ionizer or UV-C lamp(model dependent) will
be activated. If has both features, these two features will be activated at
the same time. This function will help to purify the air in the room.
Sleep function :
The SLEEP function is used to decrease energy use while you sleep (and don’t
need the same temperature settings to stay comfortable). This function can
only be activated via remote control.
For the detail, see sleep operation in USER S MANUAL.
Note: The SLEEP function is not available in FAN or DRY mode.
AP function (some units) :
Choose AP mode to do wireless network configuration. For some units, it
doesn’t work by pressing the SET button. To enter the AP mode, continuously
press the LED button seven times in 10 seconds.
Follow me function :
The FOLLOW ME function enables the remote control to measure the temperature
at its current location and send this signal to the air conditioner every 3
minutes interval. When using AUTO, COOL or HEAT modes, measuring ambient
temperature from the remote control(instead of from the indoor unit itself)
will enable the air conditioner to optimize the temperature around you and
ensure maximum comfort.
NOTE: Press and hold Turbo button for seven seconds to start/stop memory
feature of Follow Me function.
- If the memory feature is activated, On” displays for 3 seconds on the screen.
- If the memory feature is stopped, OF displays for 3 seconds on the screen.
- While the memory feature is activated,press the ON/OFF button, shift the mode or power failure will not cancel the Follow me function.
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.