Cariitti 1816012 LED Linear Sauna Installation Guide
- September 19, 2024
- Cariitti
Table of Contents
1816012 LED Linear Sauna
Specifications:
- Product Name: Sauna Linear LED
- Max Length:
- Sauna Linear 3M: 10′ 08” (3072 mm)
- Sauna Linear 6M + spot: 2 x 10′ 08” (2 x 3072 mm)
- IP Rating: IP55
- Power Supply: 100 – 277 V
- Output: 350 mA
- Country of Origin: Finland
Product Usage Instructions:
Installation Process:
Follow the steps below to install the Sauna Linear LED:
Mounting Box Assembly:
-
Drill a 5/8 in. (16 mm) hole for PG9 for the stove lens
fibre. -
Drill a 3/4 in. (19 mm) hole for PG11 for the Sauna Linear
cable and power supply cord. -
Make appropriate holes for installation based on the Sauna
Linear model.
Mounting Box Installation:
For wall installation, use the provided screws and plastic caps
to secure the mounting box.
Ensure the correct installation position with a maximum height
of 22 inches (55 cm) inside the sauna.
Connection and Setup:
-
Ensure there is no voltage (100 – 277 V) before making any
connections. -
Serial connection module must be fully utilized without any
empty slots. -
Tighten all cable glands after making connections.
-
Do not exceed the maximum current of 350 mA to avoid damage to
the LEDs. -
Avoid connecting or disconnecting LEDs when voltage is applied
to prevent LED failure.
FAQ:
Q: What tools are required for the installation?
A: You will need a drill machine, Torx screwdriver (T20 and
T10), slotted screwdriver, drill bits (5/8 in. and 3/4 in.), fixed
tools (3/4 in. and 7/8 in.), voltage meter, miter saw, Phillips
screwdriver (3.0), and flathead screwdriver (2.0).
Sauna Linear LED
Installation Instruction Instructions d’installation
1816012 1816013
1
2
13
3
4
5
6
7
8
T20
9
10
T10
IP65
www.cariitti.com
Version 12.2022
Made in Finland
EN
Sauna Linear 3M ( max length 10′ 08” = 3072 mm)
IP55
Include:
1. 2 pc LED heads incl. cable 100 in. (2,5 m) 2. 1 pc middle LED head incl. cable 100 in. (2,5 m) 3. 2 pc optical rods L = 4′ 11” (1500 mm) 4. 2 pc supportt brackets + 4 pc screws (for the rods) 5. 6 pc screws (for the LED heads) 6. 1 pc mounting box IP66 7. 4 pc screws (for the mounting box) 8. 4 pc PG11 cable gland 9. 1 pc PG9 cable gland 10. 1 pc power supply 11. 1 pc serial connection module 12. 6 pc short circuit jumpers
Sauna Linear 6M + spot ( max length 2 x 10′ 08” = 2 x 3072 mm)
IP55
1. 4 pc LED heads incl. cable 100 in. (2,5 m) 2. 2 pc middle LED heads incl. cable 100 in. (2,5 m) 3. 4 pc optical rods L = 4′ 11” (1500 mm) 4. 4 pc supportt brackets + 8 pc screws(for the rods) 5. 12 pc screws (for the LED heads) 6. 1 pc mounting box IP66 7. 4 pc screws (for the mounting box) 8. 7 pc PG11 cable glands 9. 1 pc PG9 cable gland 10. 1 pc power supply 11. 1 pc serial connection module 12. 6 pc short circuit jumpers 13. 1 pc stove lens fibre 16′ 4” ( fibre, lens and LED) (5000 mm)
In case the manufacturer´s installation instructions are not followed, and if
any other components than those listed in the instructions are used, the
manufacturer´s guarantee and liability become null and void.
You will need the following tools
Drill machine Torx screwdriver T20 and T10 Slotted screwdriver Drill bits 5/8
and 3/4 in. (16 mm and 19 mm) Fixed tool 3/4 and 7/8 in. (19 mm and 22 mm)
Voltage meter Miter saw Phillips 3.0 screwdriver Flathead 2.0 screwdriver
Version 06.2023
Mounting box assembly
PG9 for the stove lens fibre. Need a 5/8 in. hole (16 mm).
PG11 for the Sauna Linear cable and power supply cord Need a 3/4 in. hole (19
mm).
4 pc 3/4 in. (19 mm) holes 1 pc 5/8 in. (16 mm) hole
Sauna Linear 3M
PG9 Need to be installed if you use a stove lens fibre.
7 pc 3/4 in. (19 mm) holes 1 pc 5/8 in. (16 mm) hole
Sauna Linear 6M + spot
EN
Version 06.2023
EN
Mounting box installation
Installation on the wall
4 pc screws
4 pc
4 pc plastic caps Finishing the installation with plastic caps
Correct installation position
MAX 22 in. MAX 55 cm
When installing inside the sauna, the maximum installation height for the
mounting box.
Version 06.2023
OUTPUT 350 mA
EN
Sauna Linear 3M
LED
FIBRE (Optional)
minimum 2 x 18AWG SJT
LED
LED
Make sure there is no voltage
100 – 277 V
Serial connection module has to be full. No empty places! After connections tighten all cable glands
Do not change this setting! 350 mA is the maximum current. A higher current will damage the LEDs
LED
FIBRE (Optional)
minimum 2 x 18AWG SJT
LED
LED
Make sure there is no voltage
100 – 277 V
Never connect or disconnect LEDs when voltage is applied. Causes the LED to
fail.
Version 06.2023
L +
3 21 ON
OUTPUT
N
INPUT
DALI DIM DA/L DA/N
EN
Sauna Linear 6M + spot
LED
LED
LED
FIBRE
LED
minimum 2 x 18AWG SJT
LED FIBRE
LED
LED
Make sure there is no voltage
100 – 277 V
Serial connection module has to be full. No empty places! After connections tighten all cable glands
Do not change this setting! 350 mA is the maximum current. A higher current will damage the LEDs
LED LED LED
3 21 ON
OUTPUT
L +
N
minimum 2 x 18AWG SJT
LED
LED
Make sure there is no voltage
100 – 277 V
Never connect or disconnect LEDs when voltage is applied. Causes the LED to
fail.
Version 06.2023
INPUT
DALI DIM DA/L DA/N
INPUT 100 – 277 V
Make sure there is no voltage
100 – 277 V
L
INPUT
L
N
minimum 2 x 18AWG SJT
N
OUTPUT
+ –
EN
DALI DIM DA/L DA/N
Make sure there is no voltage
100 – 277 V
INPUT
L
minimum 2 x 18AWG SJT
N
+ –
OUTPUT
DALI DIM DA/L DA/N
Make sure there is no voltage
100 – 277 V
INPUT
L
minimum 2 x 18AWG SJT
N
+ –
OUTPUT
DALI DIM DA/L DA/N
Version 06.2023
FR
Sauna Linear 3M (longueur max 10′ 08” = 3072 mm)
IP55
Inclut :
1. 2 têtes de diodes avec câble 100 in. (2,5 m) 2. 1 tête de diodes centrale avec câble 100 in. (2,5 m) 3. 2 tiges optiques L = 4′ 11” (1500 mm) 4. 2 accroches pour tiges optiques + 4 vis 5. 6 vis (pour les têtes de diodes) 6. 1 boîtier de montage IP66 7. 4 vis pour le boîtier de montage 8. 4 presse- étoupes PG11 9. 1 presse-étoupe PG9 10. 1 alimentation 11. 1 module de connexion série 12. 6 ponts de court-circuit
Sauna Linear 6M + spot (longueur max 2 x 10′ 08” = 2 x 3072 mm)
IP55
1. 4 têtes de diodes avec câble 100 in. (2,5 m) 2. 2 têtes de diodes centrales avec câble 100 in. (2,5 m) 3. 4 tiges optiques L = 4′ 11” (1500 mm) 4. 4 accroches pour tiges optiques + 8 vis 5. 12 vis (pour les têtes de diodes) 6. 1 boîtier de montage IP66 7. 4 vis pour le boîtier de montage 8. 7 presse-étoupes PG11 9. 1 presse-étoupe PG9 10. 1 alimentation 11. 1 module de connexion série 12. 6 ponts de court-circuit 13. 1 fibre pour lentille de poêle 16′ 4” (fibre, lentille et diode) (5000 mm)
En cas de non-respect des instructions d’installation du fabricant et si d’autres composants que ceux énumérés dans les instructions sont utilisés, la garantie et la responsabilité du fabricant deviendront nulles et non avenues.
Vous aurez besoin des outils suivants :
Perceuse Tournevis Torx T20 et T10 Tournevis plat Forets 5/8 et 3/4 po. (16 mm
et 19 mm) Outil fixe 3/4 et 7/8 po. (19 mm et 22 mm) Voltmètre Scie à onglets
Tournevis Phillips 3.0 Tournevis plat 2.0
Version 12.2022
Ensemble de boîtier de montage
PG9 pour la fibre pour lentille de poêle.
PG11 pour le câble Sauna Linear et le câble d’alimentation Un trou de 3/4 in. (19 mm) et nécessaire.
4 trous de 3/4 po. (19 mm) 1 trou de 5/8 po. (16 mm)
Sauna Linear 3M
PG9 Doit être installé, si vous utilisez une fibre pour lentille de poêle.
7 trous de 3/4 po. (19 mm) 1 trou de 5/8 po. (16 mm)
Sauna Linear 6M + spot
FR
Version 06.2023
FR
Installation du boîtier de montage
Installation murale
4 vis
4 pc
4 bouchons en plastique Montage terminé avec des bouchons en plastique
Position de montage correcte
MAX 22 in. MAX 55 cm
Lors d’une installation à l’intérieur du sauna, hauteur maximale
d’installation pour la boîte de montage.
Version 06.2023
SORTIE 350 mA
FR
Sauna Linear 3M
DIODE
FIBRE (facultatif)
minimum 2 x 18AWG SJT
DIODE
FIBRE (facultatif)
DIODE
DIODE
Assurez-vous que la tension est nulle !
100 – 277 V
Le module de connexion série doit être complet. Pas d’emplacement vide ! Une fois les branchements terminés, serrez tous les presse-étoupes
Ne modifiez pas ce paramètre ! 350 mA est le courant maximum. Un courant supérieur endommagera les diodes
L +
minimum 2 x 18AWG SJT
N
DIODE
DIODE
Assurez-vous que la tension est nulle !
100 – 277 V
Ne jamais brancher ou débrancher les diodes lorsqu’une tension est appliquée.
Provoque la défaillance des diodes.
Version 06.2023
FR
DIODE FIBRE
Sauna Linear 6M + spot
DIODE DIODE DIODE
minimum 2 x 18AWG SJT
DIODE FIBRE
DIODE
DIODE
Assurez-vous que la tension est nulle !
100 – 277 V
Le module de connexion série doit être complet. Pas d’emplacement vide ! Une fois les branchements terminés, serrez tous les presse-étoupes
Ne modifiez pas ce paramètre ! 350 mA est le courant maximum. Un courant supérieur endommagera les diodes
DIODE DIODE DIODE
L +
N
minimum 2 x 18AWG SJT
DIODE
DIODE
Assurez-vous que la tension est nulle !
100 – 277 V
Ne jamais brancher ou débrancher les diodes lorsqu’une tension est appliquée.
Provoque la défaillance des diodes.
Version 06.2023
ENTRÉE 100 – 277 V
Assurez-vous que la tension est nulle !
100 – 277 V
L
L N
minimum 2 x 18AWG SJT
N
+ –
FR
Assurez-vous que la tension est nulle !
100 – 277 V
L
minimum 2 x 18AWG SJT
N
+ –
Assurez-vous que la tension est nulle !
100 – 277 V
L
minimum 2 x 18AWG SJT
N
+ –
Version 06.2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>