Lexco WT 5059340964577 Pegasi Indoor Emergency Round LED Bulkhead Instruction Manual

September 16, 2024
Lexco

Lexco WT 5059340964577 Pegasi Indoor Emergency Round LED Bulkhead

Specifications

  • Product Name: EN Emergency LED Bulkhead
  • EAN: 5059340964577
  • Ref: PRJ31758
  • Supply Voltage: 220-240 V~, 50 Hz
  • Bulb Type: LED (13/16/19 W)
  • Battery Type: 1 x 3.2 V 3000 mAh LiFePO4
  • Charging Time: 24 hours
  • IP Rating: IP65 Jet-proof

Product Usage Instructions

Safety Precautions

  1. Do not use the product with a dimmer switch.
  2. The light source contained in the luminaire should only be replaced by the manufacturer, service agent, or a qualified person.
  3. Do not stare directly at the operating light source to avoid eye strain.

Installation

  1. Ensure the power supply is switched off before installation.
  2. Mount the bulkhead securely on a suitable surface using the provided Besa Box.
  3. Connect the product to the power supply following the specified voltage requirements.

Maintenance

  1. Regularly clean the product using a soft, dry cloth to remove dust and dirt.
  2. Avoid using harsh chemicals or abrasive materials that may damage the surface.
  3. Check the battery periodically and replace it with the same or equivalent type when needed.

FAQ

1. What should I do if the product fails to operate?
If the product fails to operate, check the power supply and ensure it is connected correctly. If issues persist, contact the manufacturer or authorized service agent for assistance.

2. Can the bulb be replaced by the user?
No, the light source contained in the luminaire should only be replaced by the manufacturer, service agent, or a qualified person to ensure the safety and proper functioning of the product.

IMPORTANT – These instructions are for your safety. Please read through them thoroughly before handling the product and retain them for future reference.

DIMENSIONS

PARTS

You will need

Care & maintenance

Safety

  • IMPORTANT Do not use with a dimmer switch.
  • IMPORTANT , Retain for future reference: read carefully.
  • These instructions are for your safety. Please read through them thoroughly prior to installation and retain them for future reference.
  • All fittings must be installed by a competent person in accordance with local regulations (IET wiring regulation BS7671).
  • Check the pack and make sure you have all of the parts listed.
  • Remove all packaging, wrap etc from the product.
  • Decide on the appropriate location for your product.
  • CAUTION: IP65 is guaranteed when the product is properly installed and sealed.
  • Always refer to the installation drawing for the orientation of the product.
  • The product must be securely fixed to the mounting surface using the screws and wall plugs supplied. The screws and wall plugs supplied are suitable for “masonry” only. Other fixings not supplied and must be purchased.
  • Take care not to drill into any pipes or mains cables beneath the surface during mounting holes preparation.
  • IMPORTANT: The fixing point(s) selected must be capable of supporting the full weight of the light fitting.
  • CAUTION: Ensure the cable is routed so it does not present a hazard (avoid dangling loops where the cable is likely to be pulled/caught).
  • Maximum number of interconnected with same model: 15 pcs.
  • Wiring diagram is for reference only. Always refer to the terminal marking for wiring. Ensure that all electrical connections are tight and that no loose strands are left out of the terminal block.
  • USE ROUND CABLE ONLY.
  • Ensure the connection is tightened, to create a good water seal.
  • The round main cable should be at least 6.4 mm in diameter.
  • Never put anything on the product or hang anything on any part of this product.
  • Never use the terminal cables to bear the product weight.
  • The IP rating mentioned on the surround also applies to the front of the assembled product.
  • When the product does not light after installation:
    • Ensure there is no electricity failure
    • Ensure all the connections are secured
  • If you have any doubt about installation/use of this product, consult a qualified electrician.
  • Always disconnect the product from mains at least 10 minutes allowing to cool down before any maintenance or adjustment.
  • It is recommended to have a regular schedule of care and maintenance to keep the surface condition well.

Technical Data

Supply voltage:| ****

220-240 V~, 50 Hz

---|---




Bulb Type:

| LED (13/16/19 W)

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

Do not stare at the operating light source.



Battery:

| Charging time: 24hours

Type: 1 x 3.2 V 3000 mAh LiFePO4

(90 x 36.7 x 21 mm). Replace only

with the same or equivalent type.

Opteration ambient temperature (ta):| ****


0 °C to 45 °C

| This product complies with conformity requirements of the applicable European Regulations or Directives.
| This product complies with conformity requirements of the applicable UK Regulations.
Energy efficiency class:| ****

This product contains a light source

of energy efficiency class .

Control gear:| Replaceable control gear by a

professional.

**| Class II product – Double Insulated – No earth required.
IP65**| Jet-proof

| Waste electrical products should not be disposed of with household waste. Please recycle where

facilities exist. Check with your Local Authority or local store for recycling advice.

---|---
|

Caution! Risk of electric shock!

|

Do not use with a dimmer switch.

xxWyy:| xx-year; yy-week of the year.

Guarantee

We take special care to select high quality materials and use manufacturing techniques that allow us to create products incorporating design and durability. This product has a manufacturer’s guarantee of 7 years (4 years for battery pack) against manufacturing defects, from the date of purchase (if bought in store) or date of delivery (if bought online), at no additional cost for normal use. To make a claim under this guarantee, you must present your proof of purchase (such as a sales receipt, purchase invoice or other evidence admissible under applicable law), please keep your proof of purchase in a safe place. For this guarantee to apply, the product you purchased must be new, it will not apply to second hand or display products. Unless stated otherwise by applicable law, any replacement product issued under  this guarantee will only be guaranteed until expiry of theoriginal period guarantee period.

This guarantee covers product failures and malfunctions provided the product was used for the purpose for which it is intended and subject  to installation, cleaning, care and maintenance in accordance with the information contained in these terms and conditions, in the user manual and standard practice, provided that standard practice does not conflict with the user manual. This guarantee does not cover defects and damage caused by normal wear and tear or damage that could be the result of improper use, faulty installation or assembly, neglect, accident, misuse, or modification of the product. Unless stated otherwise by applicable law, this guarantee will not cover, in any case, ancillary costs (shipping, movement, costs of uninstalling and reinstalling, labour etc), or direct and indirect damage. If the product is defective, we will replace or refund, within a reasonable time. Rights under this guarantee are enforceable in the country in which you purchased this product. Guarantee related queries should be addressed to the store you purchased this product from. The guarantee is in addition to and does not affect your statutory rights.

Installation

Interconnection

Centre interconnection

Side interconnection

Max number interconnection

Maximum number of interconnected with same model: 15 pcs.

Maintenance

Type: 1 x 3.2 V 3000 mAh LiFePO4 (90 x 36.7 x 21 mm). Replace only with the same or equivalent type.

Self Test Functional test

The function test is conducted every week for 5 seconds to check the function and connection of battery and LED module.
NOTICE:

  • If a mains supply failure occurs while a functional test is in progress, the test shall be postponed and the system shall enter emergency operation. Following restoration of the mains supply, a postponed functional test shall re-commence automatically as soon as conditions permit. Duration test
  • Initial duration test: After AC mains power input for 24 hours, enter the 3-hour duration test.
  • Half year duration test: Conduct 3-hour duration test every 180-182 days to check the battery capacity.

NOTICE:

  •  A duration test shall only be started when the battery supply is fully charge if a mains supply failure occurs while a duration test is in progress, the test shall be postponed and the system shall enter emergency operation. Following restoration of the mains supply, a postponed duration test shall re-commence automatically when the battery supply is fully re-charge.
  • The indicator will be slow flashing Green within 5 days if the duration test be carried out successfully.
  • The replacement of the battery is needed when they no longer meet their rated duration of operation after the corresponding recharge period.

LED indicator

LED

Indication

| Status| Description
---|---|---
Permanent Green| Standby, System OK| Mains Operation, battery is charged
Fast flashing Green (0.25s on 0.25s off )| Function test

underway

| Function test

underway

Slow flashing Green (1s on 1s off)| Duration test underway| Duration test underway
Permanent Red| Lamp failure| Open Circuit or Short circuit or LED failure
Fast flashing Red (0.25s on 0.25s off )| Battery capacity failure| Battery failed duration test
Slow flashing Red (1s on 1s off)| Battery fault| Incorrect battery voltage or Short circuit or Open Circuit
Green and Red

off

| Battery

Operation

| Emergency mode

NOTICE:
Fault status: If an error is detected, the indicator LED switches to RED. If the error has been corrected please re-connecting the battery after the mains power off, the indicator LED immediately switches back to GREEN when mains power on. Emergency mode: The lumen output is 150 lm for 3 hours.

Battery

Case temperature from 0 °C to 60 °C to ensure 4 years design life.
NOTICE:

  • Batteries should be stored within the specified temperature range in low humidity conditions.
  • Optimal storage conditions are: Temperature: -20 °C to +40 °C Humidity: 45% – 85%.
  • Battery should be charged every three months in order to keep it’s initial performance.
  • The electric source for safety service is not a user serviceable item and shall only be replaced by the manufacturer service agent or a similar qualified person.

BHD4-EC WT 5059340964577 BHD4-EC BK 5059340963938 V20724_5059340964577_MAND2_2324

Manufacturer:

UK Manufacturer:
Kingfisher International Products Limited, 1 Paddington Square, London, W2 1GG, United Kingdom
EU Manufacturer:
Kingfisher International Products B.V., Rapenburgerstraat 175E, 1011 VM Amsterdam,
The Netherlands
EN www.diy.com
www.screwfix.com
www.screwfix.ie To view instruction manuals online, visit www.kingfisher.com/products
Made in China

Documents / Resources

| Lexco WT 5059340964577 Pegasi Indoor Emergency Round LED Bulkhead [pdf] Instruction Manual
BHD4-EC WT 5059340964577, BHD4-EC BK 5059340963938, WT 5059340964577 Pegasi Indoor Emergency Round LED Bulkhead, WT 5059340964577, Pegasi Indoor Emergency Round LED Bulkhead, Indoor Emergency Round LED Bulkhead, Emergency Round LED Bulkhead, Round LED Bulkhead, LED Bulkhead
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals