Eurolaikas CAME Proteco Hormann EURO CK 1500 Garage Door Automation Instruction Manual

June 13, 2024
Eurolaikas CAME Proteco Hormann

Eurolaikas CAME Proteco Hormann EURO CK 1500 Garage Door Automation

Functions

  • Micro intellectual control – One button to control open, stop and close. The light is on while opening or closing the door, three minutes later the light is off automatically. The unit running is controlled by computer program. Test the force of open or close the door, the optional functions are photo beam, auto-close, lock door, etc. The door pauses momentarily then rebounds when it reaches the hinders on the closing way. The protecting functions are overload, over hot or low power input, etc.
  • DC motor • Low noise, soft start, slow stopping to protect the unit and make sure it can be used for a long time.
  • LED display – Working situation can be shown on the LED screen.
  • Decoding Rolling code.
  • Manual Disengagement – Open and close the door by hand without power.
  • Optional Functions Photo beam, battery backup and wall button.

WARNING Do not operate this opener unless you are trained and authorized. if you have questions, please call professionals.

Technical Specifications

Power Input| 230V AC ±10% 50- , 60Hz| Reception frequency| 433.92MHz/

390MHz

---|---|---|---
Motor| 24V DC| Decoding| Rolling Code
Working Temperature| >-20°C,<+50°C| Transmitter power| 27A 12V Battery

/2032

Relative Humidity| 90%| Globe| LED
Open and close force| 600N BOON 1000N 1200N| Courtesy light time| 3 minutes

lnstallation

Recommended Tools

  • Installing the Operator and Rail

SUPER IMPORTANT INSTRUCTION
To avoid the original limits loosing ,this mechanical limit stopper must be installed to ensure the trolley be able to hit it in every fully opening ; It must be tightly mounted and not allowed to move when trolley crash .

Please refer to below installation steps:

  • Prepare the mechanical limit stopper ,check how it will be assembled ;
  • Make the limits setting (UP & DOWN ) ,when door is in fully opening position, put the mechanical limit stopper into the rail close the trolley (must make sure it touches the trolley )
  • Tighten the screw M6 10 first,Then tighten 2 screws M6 14.make sure mechanical stopper clamp the rail and not able to move when trolley crash

Control panel

0ptional Terminals and Connections

Programming the Operator

6.5 Force Adjustments
6.5.1 Press and hold SET, it displays “P1”.
6.5.2 Press UP once, it displays”P2″,
6.5.3 Press SET once again, it will show the current situation. Press

UP to increase the force one degree or press DOWN to decrease one degree. Maximum degree is “F9”, minimum is “F1”.| F · I
6.5.4| Press SET to confirm. The default setting is “F5”. Lt.| F5
6.5.5| After finishing all the setting, please check the force to make safe.
6.6| Photo Beam P j
6.6.1| Press and hold SET, it displays II P11| p11
6.6.2| Press UP twice, it displays “P311| P3
6.6.3| Press SET to show current situation. Press UP once it displays “H1”, the photo beam is enabled. Press down once, It displays “HO”, the photo beam is disabled. Press SET to confirm and quit.| HO

HI

6.6.4| If you do not use photo beam device, please make sure it displays” HO;’ to close this function.| HO
6.7| Auto-Close ON/OFF P ,
6.7.1| Press and hold SET, it displays “P1”.| p1
6.7.2| Press UP three times, it displays “P4”.| | p4

6.7.3

| Press SET to show current situation. Press UP to increase the auto-close one or press DOWN to decrease one.
L Ma t x . imum degree is “b9” , minimum is “b0”. Press SET to confirm.| b0

b9

6.7.4| The default setting is “b0:”‘b0″shows auto- close off. This function works when the door reaches the open position.| b0

Auto close time

LED| b0| b1| b2| b3| b4| b5| b6| b7| b8| b9
---|---|---|---|---|---|---|---|---|---|---
time(SEC.)| 0| 10| 20| 30| 40| 50| 60| 90| 120| 180

Auto close doesn’t work until photo beam is fitted and works!

0wners’ Guide

7.1 Attention in use
7.1.1

system to see if it moves well. (Test method: unlock the trolley, pull and push the door by hand.)
7.1.2| | Connected with the appropriate power and socket by professionals, and connected the earthing wire with earth.
7.1.3| | Using the transmitters in your sight. Do not stand or walk under a moving door. The transmitters should be out of reaching of children.
7.1.4| | Make sure the door out off fire, moisture, electromagnetism and some other places.
7.1.5| | Check at least twice a year to make sure the door is properly balanced and that all working parts are in good working condition. Adjust the tensile force of chain. Add suitable amount of lubricant to the active.
7.2| Examination Guide
7.2.1| Problem| Causes| Solution
7.2.2| The chain is noisy.| The chain is too loose.| Adjust nut-M8 referring to 3.2.C.
7.2.3| The motor does not work.| The socket is not well connect or the fuse is broken.| Check the socket or replace the fuse.
7.2.4| After setting open and close positions, the motor does not work.| The screws of fixing the Hall components are loose or program mistakes.| Tighten the screws or resetting open and close positions.
7.2.5| The door can’t be closed.| Photo beam function works.| Cancel the photo beam function, referring to 6.6.
7.2.6| The wall button works well, but the transmitter doesn’t work.| No transmitter learning or transmitter battery is power off.| Code referring to 6.4 or change new transmitter battery.
7.2.7| Transmitter distance is too short.| The transmitter battery is nearly power off.| Change new battery.

ENVIRONMENT FRIENDLY DISPOSAL


  • You can help protect the environment!
  • Please remember to respect the local regulations: hand in the non-working electrical equipments to an appropriate waste disposal center

Read User Manual Online (PDF format)