HUAWEI 5-12K-MAP0 Specs Solar Inverter Three Phase Specs User Guide
- September 17, 2024
- Huawei
Table of Contents
HUAWEI 5-12K-MAP0 Specs Solar Inverter Three Phase Specs
Specifications
- Rated Voltage: 415 V AC
- Rated Current:
- 5K and 6K: 16 A
- 8K: 25 A
- 10K and 12K: 32 A
Product Usage Instructions
- Make sure the device is installed according to the specified guidelines.
- The device is intended for use in Australia only.
- Follow the installation instructions provided in the manual.
- Securely install the device following the recommended steps.
- Prior to connecting, prepare a PE cable according to the provided instructions to ensure proper grounding and safety measures.
- Prepare the DC cables as instructed before connecting them to the device.
- Prepare the AC cable for connection by following the guidelines.
- Ensure all connections are secure and properly insulated.
- After installation, power on the device and proceed with the commissioning process as outlined in the manual.
- Follow the steps for a successful setup.
FAQ
- Q: Can this device be used in countries other than Australia?
- A: Well, this device is designed for use in Australia only and should not be used in other regions.
- Q: What is the recommended rated voltage and current for this device?
- A: The rated voltage is 415 V AC, and the rated current varies depending on the model: 5K and 6K have a 16 A rating, 8K has a 25 A rating, and 10K and 12K have a 32 A rating.
Before installing the equipment, read the user manual carefully to get familiar with product information and safety precautions. The product warranty does not cover equipment damage caused by failure to follow the storage, transportation, installation, and usage guidelines specified in this document and the user manual. Scan the QR code on the equipment to view the user manual and safety precautions. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure the accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Installation Requirements
Installing the Device
Preparing a PE Cable
Preparing DC Cables
- Use the positive and negative metal terminals and DC connectors supplied with the inverter.
Preparing an AC Cable
- Do not connect loads between the inverter and the AC switch that directly connects to the inverter. Otherwise, the switch may trip by mistake.
- If an AC switch is used with specifications beyond local standards, regulations, or Huawei‘s recommendations, the switch may fail to turn off on time in case of exceptions, causing serious faults.
- Each inverter must be equipped with an AC output switch. Multiple inverters cannot connect to the same AC output switch.
- To ensure that the inverter can be safely disconnected from the power grid when an exception occurs, connect an AC switch to the AC side of the inverter. Select an appropriate AC switch under local industry standards and regulations.
Strip the insulation layers of the AC output power cable by the recommended length (17–19 mm) to ensure that the cable conductors are completely inside the conductor insertion points and no insulation layer is pressed into the conductor insertion points. Tighten the cable conductors to a torque of 2.8–3.2 N·m. Otherwise, the device may fail to run properly or be damaged during operation.
Preparing Signal Cables
- A: Cascaded Inverter
- B: Power meter
- C: Ripple control device
- D: Rapid shutdown switch
Electrical Connections
Connecting DC Input Power Cables
Power-On and Commissioning
Before installing the equipment, read the user manual carefully to get familiar with product information and safety precautions. The product warranty does not cover equipment damage caused by failure to follow the storage, transport, installation, and usage guidelines specified in this document and the user manual. Scan the QR code on the equipment to view the user manual and safety precautions. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure the accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
CONTACT
Huawei Digital Power Technologies Co., Ltd.
- Huawei Digital Power Antuoshan Headquarters
- Futian, Shenzhen 518043
- People’s Republic of China
- digitalpower.huawei.com
Copyright © Huawei Digital Power Technologies Co., Ltd. 2024. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>