Murdock A192-BF Series Wall Mounted Drinking Fountain With Bottle Filler Instruction Manual

September 14, 2024
murdock

A192-BF Series Wall Mounted Drinking Fountain With Bottle Filler

“`html

Specifications

  • Model: A192400F-BF / A192400S-BF
  • Technical Assistance Telephone: 1.800.743.8259
  • Technical Assistance E-Mail: Fieldservice@acorneng.com
  • Compliance: Federal Public Law 111-380 (No Lead)

Product Usage Instructions

Installation Guidelines

1. Review the entire manual before starting the
installation.

2. Ensure compliance with plumbing, electrical, and other
relevant codes.

3. Verify rough-ins before commencing any work.

4. Wall backing and anchors must meet specified
requirements.

5. Electrical receptacles should be connected to a GFCI
protected circuit.

Roughing-In and Dimensional Drawing

Prior to roughing in, consult local, state, and federal codes
for mounting height guidelines.

Ensure proper installation of the wall-mounted drinking fountain
and bottle filler according to the provided dimensional
drawing.

FAQ

Q: What should I do if the installation requires modifications

due to specific code requirements?

A: If modifications are needed for compliance with specific
codes, consult with the local code authority and make necessary
adjustments as per their requirements.

Q: Can the drinking fountain be installed at a different height

than recommended?

A: Adjust vertical dimensions as necessary to comply with
federal, state, and local codes while ensuring proper functionality
and accessibility.

Q: How can I ensure the proper anchoring of the fixture?

A: Utilize appropriate wall anchors and anchoring hardware with
a minimum pull-out rating of 1000 lbs (453.6 kg) to securely anchor
the fixture to the wall construction.

“`

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS A192-BF Series Wall Mounted Drinking Fountain with Bottle Filler and Trim Panel

A192400F-BF / A192400S-BF
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.743.8259
Technical Assistance E-Mail: Fieldservice@acorneng.com

NOTES TO INSTALLER: 1. Please leave this documentation with the owner of the fixture when finished. 2. Please read this entire booklet before beginning the installation. 3. Check your installation for compliance with plumbing, electrical and other applicable codes.

For current Warranty click hyperlink Product Warranty or visit: www.murdockmfg.com/terms-and-warranty

COMPLIES WITH

Murdock assumes no responsibility for use of void or

suspended data. © Copyright Murdock, City of

Industry, CA Member of Morris Group International.

Please visit www.murdockmfg.com for most current specifications.

Federal Public Law

111-380 (No Lead)
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA

Phone 800-453-7465 or 626-333-2543 · www.murdoNcSkFm/AfgN.cSoIm/CAN 61

7072012-10-3013-10-00101 Page 1 of 16

Date: 03/29/24 A

A192-BF

Member of

15125 Proctor Ave, City of Industry, MeCmAb,er9o1f746 U.S.A. Phone 800-591-9360
Dwawtwe.m: 0u3rd/2oc9k/2m0fg2.4coAm

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
IMPORT ANT
Some options may slightly alter installation. To ensure proper installation review the manual thoroughly and verify rough-ins before beginning any work. File this manual with the owner or maintenance personnel upon completion of installation.
MGI Engineered Plumbing Products are designed in accord with applicable National Codes and Standards, which may include UPC, ANSI, and ASSE. Installers should use industry standard practice for details not covered within Manual. Prior to installation, supply lines must be flushed of all foreign material such as pipe dope, chips, or solder. Debris or foreign material in water supply may damage valve. An appropriate thread sealant is recommended on all threaded waste and supply connections to reduce the possibility of leaks.
When applicable: Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall anchors and wall anchoring hardware must be appropriate for wall construction and have a minimum pull-out rating of 1000 lbs. (453.6 kg).
When applicable: ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the local code authority and is the responsibility of the installer for verification.
When applicable: Electrical receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National Electrical Code).

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 2 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

ROUGHING-IN AND DIMENSIONAL DRAWING Prior to roughing in, consult with local, state, and federal codes for proper mounting height.

A192-BF Wall Mounted Drinking Fountain and Bottle Filler
Notes: 1-Standard Bi-Level rough-ins shown. For -RBL Reverse Bi-Level,
Mounting Frame rough-ins opposite

19″ [484] TRIM PANEL

138″

[35] Typ

478″ [125]

27″ [686]

1821″ [470]

42″ [1067]

6″ [152]

*27″ [686]

1-1/4″ [32] O.D. P-TRAP
PROVIDED

3821″ [978]

10″ [254] 33″ [838] 1521″ [393]

GENERAL NOTES: 1. ALL DIMENSIONS ARE IN INCHES [MM] 2. DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL
DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES
NOTES: 1. Dimensions shown for ADA compliant installation. For Child ADA 2010 compliant parallel approach installation,
decrease height of
dimensions by 2-3/4″. 2. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and
local codes.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 3 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

A192-BF Rough-In and Mounting Plate Detail

41″

34″

[19]

5″

3921″ [1041] [1003] 5″

[127] [127] 4

Typ

Typ

2

834″

*5158″ [222] [1311]

*3521″

5

[902]

*2778″

[708]

1441″ [362] 3

534″ [146]

441″ [108] Typ

6
CL

23

General Notes: 1. Dimension indicated with (*) is for 33″ drinking fountain discharge height. If discharge height differs, adjust accordingly. 2. Standard Bi-Level rough-in shown. For -RBL Reverse Bi-Level rough-in opposite. 3. Framed wall shown for reference. (Site conditions may differ)

1 38″
[9] Typ

41″ [6] 5 6 6

1034″ [273]

8 *2921″ [749]

5 7

Approx 24″ [608]

38″ [965] Opening

1 Supplied Wall Mounting Plate 2 1-1/4″ OD Waste Outlet 3 3/8″ NCT Supply Inlet 4 “S” Clip Mounting Bracket (Provided) 5 1/4″ Screw and Washers by Installer

6 5/16-18 UNC Studs and Hardware (Provided)
7 Support Framing by Installer
8 BF12 Models Only: 110VAC, 50-60Hz, Electrical Receptacle (by others) for 9 VDC, 0.8A Plug-In Power Supply (Provided)

NOTES:
1. Dimensions shown for ADA compliant installation. For Child ADA 2010 compliant parallel approach installation, decrease height of * dimensions by 2-3/4″.
2. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and local codes.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 4 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

A192-BF-WF Rough-In and Mounting Plate Detail

41″

34″

[19]

5″

3921″ [1041] [1003] 5″

[127] [127] 8

Typ

Typ

6

*5158″ [1311]

834″ [222]

3521″ [902] 2778″
[708]

1441″ [362]

534″ [146]

23

7

441″ [108] Typ

5

4

9″ [228] Typ

CL

10 2 3

421″

[115]

Typ

General Notes: 1. Dimension indicated with (*) is for 33″ drinking fountain discharge height. If discharge height differs, adjust accordingly. 2. Standard Bi-Level rough-in shown. For -RBL Reverse Bi-Level rough-in opposite. 3. Framed wall shown for reference. (Site conditions may differ)

1 38″
[9] Typ

41″ [6] 6
7
7

1034″ [273]

2921″ [749] 25″ [635]

6 5 321″ [89] 9

9
Approx 21″ [533]

38″ [965] Opening

1 Supplied Wall Mounting Plate

7 5/16-18 UNC Studs and Hardware (Provided)

2 1-1/4″ OD Waste Outlet

8 “S” Clip Mounting Bracket (Provided)

3 3/8″ NCT Supply Inlet

9 Support Framing by Installer

4 Water Filter Enclosure 5 #12 Screws by Installer 6 1/4″ Screw and Washers by Installer

10 BF12 Models Only: 110VAC, 50-60Hz, Electrical Receptacle (by others) for 9 VDC, 0.8A Plug-In Power Supply (Provided)

NOTES:
1. Dimensions shown for ADA compliant installation. For Child ADA 2010 compliant parallel approach installation, decrease height of * dimensions by 2-3/4″.
2. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and local codes.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 5 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
IMPORTANT: 1. Water Supply Service Stop Valve and Water Connections to be supplied by others in accordance with local
codes. 2. Waste is 1-1/4″ Outer Diameter. Drinking Fountain water inlet is 3/8″ Outer Diameter copper tube. Bottle
Filler water inlet is 3/8″ Outer Diameter copper tube. Water line by others. 3. Completely flush supply lines of all foreign debris before connecting to fixture. Optional Water Filter (WF), is
available should any problems with taste, odor, color, or sediment arise from the water supply. 4. All burrs must be removed from outside of cut tubes before inserting into strainer or other components. 5. Per UPC 609.10-All building water supply systems in which quick acting valves are installed shall be
provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices shall be installed as close as possible to the quick closing valve.
PRIOR TO INSTALLATION: 1. Read all installation instructions carefully, before proceeding. 2. Carefully remove all fixture components from packaging, preventing scratching or damage. Inspect fixture
and all parts from damages and all parts that are bolted on. 3. Provide mounting surface, adequate to support the fixture and loads on the fixture. 4. Provide rough-ins as shown on the roughing-in and dimensional drawing, including water supply and drain
pipe. 5. Completely flush water supply lines of all foreign debris, before connecting to the fixture.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 6 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
DRINKING FOUNTAIN INSTALLATION: 1. Insert mounting frame into the rough-in block out and secure using 1/4″-20 UNC mounting hardware
(provided by others). 2. Install the four threaded studs into the Wall Mounting Frame. 3. Remove the drinking fountain top by taking out the drain screw and lifting at the front while pulling forward.
Disconnect bubbler tube. Set top aside in a safe place where it will not be damaged. Place the screw in a secure location where it will not be lost. 4. Plug Power Supply into Electrical Receptacle (by others). 5. Hang Upper Trim Panel on Mounting Clips. 6. Slide Fixture over studs and secure with nuts and washers. 7. For -WF option: Insert Filter Enclosure using #12 wood screws (by others). 8. Assemble P-Trap to drain adapter and then assemble to unit with Phillips head screws. 9. Make-up 1-1/4″ outer diameter waste connection. 10. After thoroughly flushing the 3/8″ outer diameter supply line, connect water supply to Angle Stop (by others). 11. Place drain gasket on drain adapter. Reconnect bubbler tube. Reassemble top to unit by engaging back clip and securing with screw. 12. For -WF option: Place Lower Trim Panel onto Upper Trim Panel and secure to wall with #12 wood screws or as required for site conditions (by others) and snap in Round Plug into bottom holes.
5 A192-BF-WF Shown
26 5
1
4

3

4

12

7

3

DRINKING FOUNTAIN START UP:
1. Thoroughly flush the supply line, turn on building water supply and check all connections for leaks. 2. Air within the drinking fountain system or the structure supply piping will cause an irregular bubbler outlet
stream until purged out by incoming water. Covering the bubbler with a clean cup (or similar object) is recommended when first activating drinking fountain to prevent excessive splashing. Depress front pushbutton until steady water stream is achieved. 3. If water flow requires adjustment, insert a slotted narrow blade screwdriver in the hole centered on the underside of the fixture in the knee clearance area up to the flow regulator. Turning clockwise will increase flow and turning counterclockwise will decrease flow. 4. Recheck all water connections with water flowing through system. THOROUGHLY CHECK FIXTURE FOR WATER LEAKS.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 7 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

BF11/BF12 INSTALLATION INSTRUCTIONS
1 Unfasten screws that hold the Bottle Filler Housing to the Mounting Channel. Disconnect insulated 41″ riser tubing from Solenoid Valve to separate. Place Bottle Filler Housing and screws in a secure location.
2 4 5

1 Bottle Filler Housing 2 Mounting Channel 3 #10-32 x 1″ Button Head Screw 4 Solenoid Valve 5 1/4″ OD Insulated Tubing

3

3

1

1

2 Center BF Mounting Channel over Fountain deck and anchor to upper trim panel, securing with wall anchors and anchoring hardware provided.

1 Drinking Fountain deck and cabinet 2 Mounting Channel 3 4x Mounting Holes (A) 4 Anchoring Hardware provided

7″ Typ (A)

14″ Typ (A)

2
Ø1/4″ Mounting
Holes

(A)

(A)

*NOTE: Thread 1/4″ OD insulated inlet

tubing through Grommet and into

15″

3

4

3

cabinet prior to securing to wall.

Typ (A)

CL

*NOTE: Insulation Tubing may overlap Fittings. Illustrations may show exposed 1/4″ OD Tubing for clarity only.

2

(A)

(A)

1

BF12 Shown

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 8 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

BF11/BF12 INSTALLATION INSTRUCTIONS (Continued)

BF11 SERIES

3A

With Mounting Panel secured, place Bottle Filler Housing on top of the Water Cooler and connect water supply line from Bottle Filler to Pneumatic Valve Outlet. Connect 1/8″ Air-Line to Pushbutton and Pneumatic Valve Inlet.

3

5

1/4″ Min.

1

1 Bottle Filler Housing 2 Water Cooler Assembly 3 1/4″ O.D. Polyethylene Supply Line 4 Pneumatic Valve 5 Mounting Panel 6 Valve Water Supply Outlet Elbow 7 Valve Air-Line Supply Inlet 8 1/8″ O.D. Polyethylene Supply Line 9 Pushbutton

4 6

8

2

7

9
1/4″ Min.

! IMPORTANT
FOR BF11 SERIES, FOLLOW STEP 3A FOR BF12 SERIES, FOLLOW STEP 3B

8

BF12 SERIES
3B With Mounting Panel secured, place Bottle Filler Housing on top of the Water Cooler and connect water supply line from Bottle Filler to Solenoid Valve Outlet.

3

1/4″ Min.

5

1

1 Bottle Filler Housing

2 Water Cooler Assembly

3 1/4″ O.D. Polyethylene Supply Line 4

6

4 Solenoid Valve

5 Mounting Panel

6 Valve Water Supply Outlet Elbow

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 9 of 16

A192-BF

2
Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

BF11/BF12 INSTALLATION INSTRUCTIONS (Continued)

BF12-BCD SERIES
4A Connect Electrical wiring as shown in diagram. If unit does not have -BCD Bottle Count Display, skip to step 4B.
3

1 -BCD Bottle Count Display 2 Sensor 3 Solenoid Valve 4 Power Supply 5 Black Wire – BCD

1

2

5

4

4
BF12 SERIES
4B Connect Electrical wiring as shown in diagram. If unit has -BCD Bottle Count Display, see step 4A before continuing.
2

3 1 Sensor 2 Solenoid Valve 3 Power Supply

1 3

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 10 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
TROUBLE SHOOTING: 1. ADJUSTMENTS:
a. Cartridge ­ The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow.
c. Bubbler Stream – Bubbler can be rotated slightly to direct the stream backwards or forwards. Adjust the stream to minimize splashing. Splashing may occur from bubbler stream if the unit is not level. Shim lower mounting point, if necessary, to level chiller.
2. RESTRICTED OR NO WATER FLOW: a. Ensure water supply service stop valve is fully open. b. Verify minimum 20 psig supply line flow pressure. c. Check for twists or kinks in outlet tubing. d. Check the water inlet “Y” strainer. Sediment from the main supply can get trapped in the screen along with installation materials such as pipe dope and flux. The screen should be cleaned and checked on a regular basis and replace if needed. e. The cartridge valve located in the water control assembly or bubbler can also become clogged with foreign material. The cartridge valve can only be replaced and not repaired. f. Check flow adjustment. See start up note #3. g. Flow control in solenoid valve outlet elbow clogged remove & clean. h. No power to transformer connections, loose or wires cut.
3. WATER DRIPS OR WILL NOT SHUT OFF: a. Open fixture. Loosen nuts holding valve bracket assembly to bottom of fixture but, do not remove. Move complete valve bracket assembly further back from the front push pad and tighten to lock in place. b. Replace valve cartridge.
CLEANING & MAINTENANCE GUIDE: 1. Periodically remove fountain top and clean out in-line strainer. 2. Periodically remove panel of bottle filler and clean out inline “Y” strainer.
For Stainless steel units: 1. To Remove water spots or rust spots, stainless steel cleaner/polish on a cloth is recommended. 2. If there are stubborn spots or if you wish to treat a scratch, using synthetic abrasive general
purpose pads, such as Scotch-BriteTM, are recommended. 3. Apply stainless steel cleaner/ polish to the synthetic abrasive pads and carefully rub the panel with the grain. 4. DO NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the Murdock
warranty. 5. Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/ polish is maintained,
stainless steel surfaces will retain their new, clean, polished appearance indefinitely.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 11 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT CLEAN, BAGGED AND UNDAMAGED PRIOR TO INSTALLATION.
TO CUT TUBE: Cut to fit length of 1/4″ PE tubing and remove any burrs or sharp edges. Ensure that the outside diameter is free from score marks. Tube ends should be square.

INSERTING THE TUBE: 1. Firmly and fully insert the tubing end into the
push-in fitting up to the tube stop located approximately ½” deep.
2. Pull on the fitted tubing to ensure it is secure. Tube should not come free from the fitting. Water test the connection assembly prior to leaving the site to ensure there are no leaks.

COLLET

O-RING O-RING

TUBE STOP COLLET

COLLET

DISCONNECTING THE TUBE: To disconnect the tube from the fitting ensure that the water line is depressurized. Push collet square towards the push-in fitting body and hold. While holding the collet in, pull on the PE tubing to remove from the push-in fitting.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 12 of 16

A192-BF

COLLET
COLLET
Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE Note: Use the Universal Maintenance Tool to perform the following: 1. Strainer Plug must be removed before Cartridge replacement and Strainer maintenance (no need to turn the
water off at the Angle Stop). Some residual water will drain during Plug removal. 2. Clean Strainer as needed using clean water. 3. Cartridge Replacement – insert diamond end of the Universal Tool into Pushbutton, rotate 90 degrees and pull
firmly to remove the Button. Remove Cartridge Retaining Nut . Remove and replace Cartridge. When replacing Cartridge, be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body. — NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.

CARTRIDGE VALVE PARTS BREAKDOWN

ITEM # 1 2 3 4 5 6

PART NUMBER 7003-095-002 7000-060-000 7000-052-000 7003-864-000 7003-097-001 7003-194-199

DESCRIPTION Valve Body Sub Assembly Valve Cartridge Retaining Nut Strainer, Auto Stop Strainer Cap Maintenance Tool

1
2 3
4
5

6
Universal Maintenance Tool
-Button Removal -Cartridge Retaining Nut -Strainer Plug -Removal of P.E. Tubing from Push-in Fittings

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 13 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
DRINKING FOUNTAIN PARTS BREAKDOWN DRAWING
19 5
6A 6B

NOTE: ** Flow Restrictor Only Available
With Low Flow Bubbler.
16 2
1

18
3 4 17 7

8
9 10 11

15 14 13 12

ITEM # PART NUMBER DESCRIPTION 1 7000-005-199 Drain Adapter 2 0116-016-000

10-32 x 3/8″ Phillips Truss Head Screw 3 7000-006-000 Flat Drain Adapter

Gasket 4 7000-015-000 1-1/4″ OD P-Trap 5 0126-209-000 #10-32 x 3/4″ Torx Button Head Screw 6A 7000-012-001 Stainless Steel Bubbler Assembly 6B 7000-099-002 Flexible Gray Bubbler Assembly 7 1895-710-000 1/4″ Push-In Union Tee 8 7003-195-000 Spring, Overtravel 9 7003-193-000 Spring, Pushbutton Return

ITEM # PART NUMBER DESCRIPTION 10 7003-196-199 Pushbutton, Chrome 11 7003-197-199 Escutcheon, Chrome 12 0161-060-000 #6-32 x 1/2″ Socket Cap, Flat Hd Screw 13 0124-055-000 #8 x 3/4″ Phillips, Round Head Screw 14 7003-198-199 Mounting Sleeve 15 7003-095-001 Valve Body Sub Assembly 16 7003-093-001 Flow Restrictor – Low-Flow Bubbler Only 17 1895-715-000 1/4″ Acetal Plug 18 0250-016-000 #10 x 3/4″ Sheet Metal Screw 19 7003-166-000 Round Plug

Repairs must be made with Murdock Manufacturing parts only. Please order through your local representative or distributor. The phone number to locate your local representative is 1.800.591.9360.

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 14 of 16

A192-BF

Member of
Date: 03/29/2024 A

DRINKING FOUNTAIN

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

12 11 10 4
1
2

8 9

12 11 10 4
1
2

8 9

3 3

5 7

A192-BF

3 3

5

6

7

A192-BF-WF

ITEM # 1
2
3 4 5
6
7 8 9 10 11 12

PART NUMBER 7001-716-001
BF11 BF12 BF12-BCD 7001-700-001 7001-711-001 7001-714-001 7001-718-001 7001-719-001 7001-726-000 7001-709-199 0250-013-000 0243-026-000 0332-006-000 0304-006-000

DESCRIPTION Wall Mounting Plate Bottle Filler with Pushbutton Operation Bottle Filler with Sensor Operation Bottle Filler with Sensor Operation & Bottle Counter Display Wide Contour Fountain Upper Trim Panel Assembly Lower Trim Panel Filter Assembly, 1,500 Gallons Filter Assembly, 3,000 Gallons Round Plug Bracket, Upper Trim Panel Support Wood Screw, #12 x 1-1/4″, Flat Head, S/S Stud, 5/16-18 UNC x 4″ Lg, Zinc Plated Flat Washer, 5/16 Zinc Plated Hex Nut, 5/16-18 UNC , Zinc Plated Steel

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 15 of 16

A192-BF

Member of
Date: 03/29/2024 A

CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS

Optional -WF1 Water Filter

ITEM PART NUMBER

DESCRIPTION

1 7001-730-001 FILTER ENCLOSURE ASSY, 1,500 GALLONS

2 7001-728-002 FILTER ENCLOSURE

7

3 7012-309-001 WF1 FILTER, 1,500 GALLONS

4 2169-000-000 1/4″ OD TUBE, 3-1/2 FEET LONG

5 1895-709-000 ELBOW, 1/4″ OD PUSH-IN x 1/4″ OD STEM

6 7012-319-000 STRAP W/ BUCKLE

7 7012-313-000 REPLACEMENT CARTRIDGE

1
2
6 3 5 4

Optional -WF3 Water Filter

ITEM PART NUMBER

DESCRIPTION

1 7001-728-001 FILTER ENCLOSURE ASSY, 3,000 GALLONS

2 7001-728-002 FILTER ENCLOSURE

3 7012-333-001 WF3 FILTER, 3,000 GALLONS

4 2169-000-000 1/4″ OD TUBE, 3-1/2 FEET LONG

5 1895-709-000 ELBOW, 1/4″ PUSH-IN x 1/4″ OD STEM
7
6 7012-319-000 STRAP W/ BUCKLE

7 7012-318-000 REPLACEMENT CARTRIDGE

1
2
6 3 5 4

MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com

7021-031-001 Page 16 of 16

A192-BF

Member of
Date: 03/29/2024 A

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>