Murdock A192-BF Series Wall Mounted Drinking Fountain With Bottle Filler Instruction Manual
- September 14, 2024
- murdock
Table of Contents
- A192-BF Series Wall Mounted Drinking Fountain With Bottle Filler
- Specifications
- Product Usage Instructions
- Installation Guidelines
- Roughing-In and Dimensional Drawing
- Q: What should I do if the installation requires modifications
- Q: Can the drinking fountain be installed at a different height
- Q: How can I ensure the proper anchoring of the fixture?
A192-BF Series Wall Mounted Drinking Fountain With Bottle Filler
“`html
Specifications
- Model: A192400F-BF / A192400S-BF
- Technical Assistance Telephone: 1.800.743.8259
- Technical Assistance E-Mail: Fieldservice@acorneng.com
- Compliance: Federal Public Law 111-380 (No Lead)
Product Usage Instructions
Installation Guidelines
1. Review the entire manual before starting the
installation.
2. Ensure compliance with plumbing, electrical, and other
relevant codes.
3. Verify rough-ins before commencing any work.
4. Wall backing and anchors must meet specified
requirements.
5. Electrical receptacles should be connected to a GFCI
protected circuit.
Roughing-In and Dimensional Drawing
Prior to roughing in, consult local, state, and federal codes
for mounting height guidelines.
Ensure proper installation of the wall-mounted drinking fountain
and bottle filler according to the provided dimensional
drawing.
FAQ
Q: What should I do if the installation requires modifications
due to specific code requirements?
A: If modifications are needed for compliance with specific
codes, consult with the local code authority and make necessary
adjustments as per their requirements.
Q: Can the drinking fountain be installed at a different height
than recommended?
A: Adjust vertical dimensions as necessary to comply with
federal, state, and local codes while ensuring proper functionality
and accessibility.
Q: How can I ensure the proper anchoring of the fixture?
A: Utilize appropriate wall anchors and anchoring hardware with
a minimum pull-out rating of 1000 lbs (453.6 kg) to securely anchor
the fixture to the wall construction.
“`
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS A192-BF Series Wall Mounted Drinking Fountain with Bottle Filler and Trim Panel
A192400F-BF / A192400S-BF
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.743.8259
Technical Assistance E-Mail: Fieldservice@acorneng.com
NOTES TO INSTALLER: 1. Please leave this documentation with the owner of the fixture when finished. 2. Please read this entire booklet before beginning the installation. 3. Check your installation for compliance with plumbing, electrical and other applicable codes.
For current Warranty click hyperlink Product Warranty or visit: www.murdockmfg.com/terms-and-warranty
COMPLIES WITH
Murdock assumes no responsibility for use of void or
suspended data. © Copyright Murdock, City of
Industry, CA Member of Morris Group International.
Please visit www.murdockmfg.com for most current specifications.
Federal Public Law
111-380 (No Lead)
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 · www.murdoNcSkFm/AfgN.cSoIm/CAN 61
7072012-10-3013-10-00101 Page 1 of 16
Date: 03/29/24 A
A192-BF
Member of
15125 Proctor Ave, City of Industry, MeCmAb,er9o1f746 U.S.A. Phone
800-591-9360
Dwawtwe.m: 0u3rd/2oc9k/2m0fg2.4coAm
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE
INSTRUCTIONS
IMPORT ANT
Some options may slightly alter installation. To ensure proper installation
review the manual thoroughly and verify rough-ins before beginning any work.
File this manual with the owner or maintenance personnel upon completion of
installation.
MGI Engineered Plumbing Products are designed in accord with applicable
National Codes and Standards, which may include UPC, ANSI, and ASSE.
Installers should use industry standard practice for details not covered
within Manual. Prior to installation, supply lines must be flushed of all
foreign material such as pipe dope, chips, or solder. Debris or foreign
material in water supply may damage valve. An appropriate thread sealant is
recommended on all threaded waste and supply connections to reduce the
possibility of leaks.
When applicable: Industry standard wall backing, for wall hung fixtures, is
required. Installer provided wall anchors and wall anchoring hardware must be
appropriate for wall construction and have a minimum pull-out rating of 1000
lbs. (453.6 kg).
When applicable: ANSI, UFAS or ADA compliance is subject to the interpretation
and requirements of the local code authority and is the responsibility of the
installer for verification.
When applicable: Electrical receptacle(s) must be wired to a GFCI protected
circuit. Fixture must be earth grounded per N.E.C. (National Electrical Code).
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 2 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
ROUGHING-IN AND DIMENSIONAL DRAWING Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
A192-BF Wall Mounted Drinking Fountain and Bottle Filler
Notes: 1-Standard Bi-Level rough-ins shown. For -RBL Reverse Bi-Level,
Mounting Frame rough-ins opposite
19″ [484] TRIM PANEL
138″
[35] Typ
478″ [125]
27″ [686]
1821″ [470]
42″ [1067]
6″ [152]
*27″ [686]
1-1/4″ [32] O.D. P-TRAP
PROVIDED
3821″ [978]
10″ [254] 33″ [838] 1521″ [393]
GENERAL NOTES: 1. ALL DIMENSIONS ARE IN INCHES [MM] 2. DIMENSIONS SHOWN ARE
FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL
DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES
NOTES: 1. Dimensions shown for ADA compliant installation. For Child ADA 2010
compliant parallel approach installation,
decrease height of dimensions by 2-3/4″. 2. Provide clear floor space as
required. Adjust vertical dimensions as required to comply with federal,
state, and
local codes.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 3 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
A192-BF Rough-In and Mounting Plate Detail
41″
34″
[19]
5″
3921″ [1041] [1003] 5″
[127] [127] 4
Typ
Typ
2
834″
*5158″ [222] [1311]
*3521″
5
[902]
*2778″
[708]
1441″ [362] 3
534″ [146]
441″ [108] Typ
6
CL
23
General Notes: 1. Dimension indicated with (*) is for 33″ drinking fountain discharge height. If discharge height differs, adjust accordingly. 2. Standard Bi-Level rough-in shown. For -RBL Reverse Bi-Level rough-in opposite. 3. Framed wall shown for reference. (Site conditions may differ)
1 38″
[9] Typ
41″ [6] 5 6 6
1034″ [273]
8 *2921″ [749]
5 7
Approx 24″ [608]
38″ [965] Opening
1 Supplied Wall Mounting Plate 2 1-1/4″ OD Waste Outlet 3 3/8″ NCT Supply Inlet 4 “S” Clip Mounting Bracket (Provided) 5 1/4″ Screw and Washers by Installer
6 5/16-18 UNC Studs and Hardware (Provided)
7 Support Framing by Installer
8 BF12 Models Only: 110VAC, 50-60Hz, Electrical Receptacle (by others) for 9
VDC, 0.8A Plug-In Power Supply (Provided)
NOTES:
1. Dimensions shown for ADA compliant installation. For Child ADA 2010
compliant parallel approach installation, decrease height of * dimensions by
2-3/4″.
2. Provide clear floor space as required. Adjust vertical dimensions as
required to comply with federal, state, and local codes.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 4 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
A192-BF-WF Rough-In and Mounting Plate Detail
41″
34″
[19]
5″
3921″ [1041] [1003] 5″
[127] [127] 8
Typ
Typ
6
*5158″ [1311]
834″ [222]
3521″ [902] 2778″
[708]
1441″ [362]
534″ [146]
23
7
441″ [108] Typ
5
4
9″ [228] Typ
CL
10 2 3
421″
[115]
Typ
General Notes: 1. Dimension indicated with (*) is for 33″ drinking fountain discharge height. If discharge height differs, adjust accordingly. 2. Standard Bi-Level rough-in shown. For -RBL Reverse Bi-Level rough-in opposite. 3. Framed wall shown for reference. (Site conditions may differ)
1 38″
[9] Typ
41″ [6] 6
7
7
1034″ [273]
2921″ [749] 25″ [635]
6 5 321″ [89] 9
9
Approx 21″ [533]
38″ [965] Opening
1 Supplied Wall Mounting Plate
7 5/16-18 UNC Studs and Hardware (Provided)
2 1-1/4″ OD Waste Outlet
8 “S” Clip Mounting Bracket (Provided)
3 3/8″ NCT Supply Inlet
9 Support Framing by Installer
4 Water Filter Enclosure 5 #12 Screws by Installer 6 1/4″ Screw and Washers by Installer
10 BF12 Models Only: 110VAC, 50-60Hz, Electrical Receptacle (by others) for 9 VDC, 0.8A Plug-In Power Supply (Provided)
NOTES:
1. Dimensions shown for ADA compliant installation. For Child ADA 2010
compliant parallel approach installation, decrease height of * dimensions by
2-3/4″.
2. Provide clear floor space as required. Adjust vertical dimensions as
required to comply with federal, state, and local codes.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 5 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE
INSTRUCTIONS
IMPORTANT: 1. Water Supply Service Stop Valve and Water Connections to be
supplied by others in accordance with local
codes. 2. Waste is 1-1/4″ Outer Diameter. Drinking Fountain water inlet is
3/8″ Outer Diameter copper tube. Bottle
Filler water inlet is 3/8″ Outer Diameter copper tube. Water line by others.
3. Completely flush supply lines of all foreign debris before connecting to
fixture. Optional Water Filter (WF), is
available should any problems with taste, odor, color, or sediment arise from
the water supply. 4. All burrs must be removed from outside of cut tubes
before inserting into strainer or other components. 5. Per UPC 609.10-All
building water supply systems in which quick acting valves are installed shall
be
provided with devices to absorb the hammer caused by high pressure resulting
from the quick closing of the valve. These pressure-absorbing devices shall be
approved mechanical devices. Water pressure-absorbing devices shall be
installed as close as possible to the quick closing valve.
PRIOR TO INSTALLATION: 1. Read all installation instructions carefully, before
proceeding. 2. Carefully remove all fixture components from packaging,
preventing scratching or damage. Inspect fixture
and all parts from damages and all parts that are bolted on. 3. Provide
mounting surface, adequate to support the fixture and loads on the fixture. 4.
Provide rough-ins as shown on the roughing-in and dimensional drawing,
including water supply and drain
pipe. 5. Completely flush water supply lines of all foreign debris, before
connecting to the fixture.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 6 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE
INSTRUCTIONS
DRINKING FOUNTAIN INSTALLATION: 1. Insert mounting frame into the rough-in
block out and secure using 1/4″-20 UNC mounting hardware
(provided by others). 2. Install the four threaded studs into the Wall
Mounting Frame. 3. Remove the drinking fountain top by taking out the drain
screw and lifting at the front while pulling forward.
Disconnect bubbler tube. Set top aside in a safe place where it will not be
damaged. Place the screw in a secure location where it will not be lost. 4.
Plug Power Supply into Electrical Receptacle (by others). 5. Hang Upper Trim
Panel on Mounting Clips. 6. Slide Fixture over studs and secure with nuts and
washers. 7. For -WF option: Insert Filter Enclosure using #12 wood screws (by
others). 8. Assemble P-Trap to drain adapter and then assemble to unit with
Phillips head screws. 9. Make-up 1-1/4″ outer diameter waste connection. 10.
After thoroughly flushing the 3/8″ outer diameter supply line, connect water
supply to Angle Stop (by others). 11. Place drain gasket on drain adapter.
Reconnect bubbler tube. Reassemble top to unit by engaging back clip and
securing with screw. 12. For -WF option: Place Lower Trim Panel onto Upper
Trim Panel and secure to wall with #12 wood screws or as required for site
conditions (by others) and snap in Round Plug into bottom holes.
5 A192-BF-WF Shown
26 5
1
4
3
4
12
7
3
DRINKING FOUNTAIN START UP:
1. Thoroughly flush the supply line, turn on building water supply and check
all connections for leaks. 2. Air within the drinking fountain system or the
structure supply piping will cause an irregular bubbler outlet
stream until purged out by incoming water. Covering the bubbler with a clean
cup (or similar object) is recommended when first activating drinking fountain
to prevent excessive splashing. Depress front pushbutton until steady water
stream is achieved. 3. If water flow requires adjustment, insert a slotted
narrow blade screwdriver in the hole centered on the underside of the fixture
in the knee clearance area up to the flow regulator. Turning clockwise will
increase flow and turning counterclockwise will decrease flow. 4. Recheck all
water connections with water flowing through system. THOROUGHLY CHECK FIXTURE
FOR WATER LEAKS.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 7 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
BF11/BF12 INSTALLATION INSTRUCTIONS
1 Unfasten screws that hold the Bottle Filler Housing to the Mounting Channel.
Disconnect insulated 41″ riser tubing from Solenoid Valve to separate. Place
Bottle Filler Housing and screws in a secure location.
2 4 5
1 Bottle Filler Housing 2 Mounting Channel 3 #10-32 x 1″ Button Head Screw 4 Solenoid Valve 5 1/4″ OD Insulated Tubing
3
3
1
1
2 Center BF Mounting Channel over Fountain deck and anchor to upper trim panel, securing with wall anchors and anchoring hardware provided.
1 Drinking Fountain deck and cabinet 2 Mounting Channel 3 4x Mounting Holes (A) 4 Anchoring Hardware provided
7″ Typ (A)
14″ Typ (A)
2
Ø1/4″ Mounting
Holes
(A)
(A)
*NOTE: Thread 1/4″ OD insulated inlet
tubing through Grommet and into
15″
3
4
3
cabinet prior to securing to wall.
Typ (A)
CL
*NOTE: Insulation Tubing may overlap Fittings. Illustrations may show exposed 1/4″ OD Tubing for clarity only.
2
(A)
(A)
1
BF12 Shown
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 8 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
BF11/BF12 INSTALLATION INSTRUCTIONS (Continued)
BF11 SERIES
3A
With Mounting Panel secured, place Bottle Filler Housing on top of the Water Cooler and connect water supply line from Bottle Filler to Pneumatic Valve Outlet. Connect 1/8″ Air-Line to Pushbutton and Pneumatic Valve Inlet.
3
5
1/4″ Min.
1
1 Bottle Filler Housing 2 Water Cooler Assembly 3 1/4″ O.D. Polyethylene Supply Line 4 Pneumatic Valve 5 Mounting Panel 6 Valve Water Supply Outlet Elbow 7 Valve Air-Line Supply Inlet 8 1/8″ O.D. Polyethylene Supply Line 9 Pushbutton
4 6
8
2
7
9
1/4″ Min.
! IMPORTANT
FOR BF11 SERIES, FOLLOW STEP 3A FOR BF12 SERIES, FOLLOW STEP 3B
8
BF12 SERIES
3B With Mounting Panel secured, place Bottle Filler Housing on top of the
Water Cooler and connect water supply line from Bottle Filler to Solenoid
Valve Outlet.
3
1/4″ Min.
5
1
1 Bottle Filler Housing
2 Water Cooler Assembly
3 1/4″ O.D. Polyethylene Supply Line 4
6
4 Solenoid Valve
5 Mounting Panel
6 Valve Water Supply Outlet Elbow
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 9 of 16
A192-BF
2
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
BF11/BF12 INSTALLATION INSTRUCTIONS (Continued)
BF12-BCD SERIES
4A Connect Electrical wiring as shown in diagram. If unit does not have -BCD
Bottle Count Display, skip to step 4B.
3
1 -BCD Bottle Count Display 2 Sensor 3 Solenoid Valve 4 Power Supply 5 Black Wire – BCD
1
2
5
4
4
BF12 SERIES
4B Connect Electrical wiring as shown in diagram. If unit has -BCD Bottle
Count Display, see step 4A before continuing.
2
3 1 Sensor 2 Solenoid Valve 3 Power Supply
1 3
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 10 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE
INSTRUCTIONS
TROUBLE SHOOTING: 1. ADJUSTMENTS:
a. Cartridge The water flow can be adjusted using a slotted narrow blade
screwdriver and turning clockwise to increase flow and counterclockwise to
decrease flow.
c. Bubbler Stream – Bubbler can be rotated slightly to direct the stream
backwards or forwards. Adjust the stream to minimize splashing. Splashing may
occur from bubbler stream if the unit is not level. Shim lower mounting point,
if necessary, to level chiller.
2. RESTRICTED OR NO WATER FLOW: a. Ensure water supply service stop valve is
fully open. b. Verify minimum 20 psig supply line flow pressure. c. Check for
twists or kinks in outlet tubing. d. Check the water inlet “Y” strainer.
Sediment from the main supply can get trapped in the screen along with
installation materials such as pipe dope and flux. The screen should be
cleaned and checked on a regular basis and replace if needed. e. The cartridge
valve located in the water control assembly or bubbler can also become clogged
with foreign material. The cartridge valve can only be replaced and not
repaired. f. Check flow adjustment. See start up note #3. g. Flow control in
solenoid valve outlet elbow clogged remove & clean. h. No power to transformer
connections, loose or wires cut.
3. WATER DRIPS OR WILL NOT SHUT OFF: a. Open fixture. Loosen nuts holding
valve bracket assembly to bottom of fixture but, do not remove. Move complete
valve bracket assembly further back from the front push pad and tighten to
lock in place. b. Replace valve cartridge.
CLEANING & MAINTENANCE GUIDE: 1. Periodically remove fountain top and clean
out in-line strainer. 2. Periodically remove panel of bottle filler and clean
out inline “Y” strainer.
For Stainless steel units: 1. To Remove water spots or rust spots, stainless
steel cleaner/polish on a cloth is recommended. 2. If there are stubborn spots
or if you wish to treat a scratch, using synthetic abrasive general
purpose pads, such as Scotch-BriteTM, are recommended. 3. Apply stainless
steel cleaner/ polish to the synthetic abrasive pads and carefully rub the
panel with the grain. 4. DO NOT use harsh chemicals, abrasive or petroleum
based cleaners. Use of these will void the Murdock
warranty. 5. Stainless steel should be kept clean at all times. If a coating
of stainless steel cleaner/ polish is maintained,
stainless steel surfaces will retain their new, clean, polished appearance
indefinitely.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 11 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE
INSTRUCTIONS
PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT CLEAN, BAGGED AND UNDAMAGED PRIOR TO
INSTALLATION.
TO CUT TUBE: Cut to fit length of 1/4″ PE tubing and remove any burrs or sharp
edges. Ensure that the outside diameter is free from score marks. Tube ends
should be square.
INSERTING THE TUBE: 1. Firmly and fully insert the tubing end into the
push-in fitting up to the tube stop located approximately ½” deep.
2. Pull on the fitted tubing to ensure it is secure. Tube should not come
free from the fitting. Water test the connection assembly prior to leaving the
site to ensure there are no leaks.
COLLET
O-RING O-RING
TUBE STOP COLLET
COLLET
DISCONNECTING THE TUBE: To disconnect the tube from the fitting ensure that the water line is depressurized. Push collet square towards the push-in fitting body and hold. While holding the collet in, pull on the PE tubing to remove from the push-in fitting.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 12 of 16
A192-BF
COLLET
COLLET
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE
INSTRUCTIONS
CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE Note: Use the Universal
Maintenance Tool to perform the following: 1. Strainer Plug must be removed
before Cartridge replacement and Strainer maintenance (no need to turn the
water off at the Angle Stop). Some residual water will drain during Plug
removal. 2. Clean Strainer as needed using clean water. 3. Cartridge
Replacement – insert diamond end of the Universal Tool into Pushbutton, rotate
90 degrees and pull
firmly to remove the Button. Remove Cartridge Retaining Nut . Remove and
replace Cartridge. When replacing Cartridge, be sure to align the inlet and
outlet Ports on the Cartridge with the Ports in the Valve Body. — NOTE:
STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.
CARTRIDGE VALVE PARTS BREAKDOWN
ITEM # 1 2 3 4 5 6
PART NUMBER 7003-095-002 7000-060-000 7000-052-000 7003-864-000 7003-097-001 7003-194-199
DESCRIPTION Valve Body Sub Assembly Valve Cartridge Retaining Nut Strainer, Auto Stop Strainer Cap Maintenance Tool
1
2 3
4
5
6
Universal Maintenance Tool
-Button Removal -Cartridge Retaining Nut -Strainer Plug -Removal of P.E. Tubing from Push-in Fittings
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 13 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE
INSTRUCTIONS
DRINKING FOUNTAIN PARTS BREAKDOWN DRAWING
19 5
6A 6B
NOTE: ** Flow Restrictor Only Available
With Low Flow Bubbler.
16 2
1
18
3 4 17 7
8
9 10 11
15 14 13 12
ITEM # PART NUMBER DESCRIPTION 1 7000-005-199 Drain Adapter 2 0116-016-000
10-32 x 3/8″ Phillips Truss Head Screw 3 7000-006-000 Flat Drain Adapter
Gasket 4 7000-015-000 1-1/4″ OD P-Trap 5 0126-209-000 #10-32 x 3/4″ Torx Button Head Screw 6A 7000-012-001 Stainless Steel Bubbler Assembly 6B 7000-099-002 Flexible Gray Bubbler Assembly 7 1895-710-000 1/4″ Push-In Union Tee 8 7003-195-000 Spring, Overtravel 9 7003-193-000 Spring, Pushbutton Return
ITEM # PART NUMBER DESCRIPTION 10 7003-196-199 Pushbutton, Chrome 11 7003-197-199 Escutcheon, Chrome 12 0161-060-000 #6-32 x 1/2″ Socket Cap, Flat Hd Screw 13 0124-055-000 #8 x 3/4″ Phillips, Round Head Screw 14 7003-198-199 Mounting Sleeve 15 7003-095-001 Valve Body Sub Assembly 16 7003-093-001 Flow Restrictor – Low-Flow Bubbler Only 17 1895-715-000 1/4″ Acetal Plug 18 0250-016-000 #10 x 3/4″ Sheet Metal Screw 19 7003-166-000 Round Plug
Repairs must be made with Murdock Manufacturing parts only. Please order through your local representative or distributor. The phone number to locate your local representative is 1.800.591.9360.
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 14 of 16
A192-BF
Member of
Date: 03/29/2024 A
DRINKING FOUNTAIN
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
12 11 10 4
1
2
8 9
12 11 10 4
1
2
8 9
3 3
5 7
A192-BF
3 3
5
6
7
A192-BF-WF
ITEM # 1
2
3 4 5
6
7 8 9 10 11 12
PART NUMBER 7001-716-001
BF11 BF12 BF12-BCD 7001-700-001 7001-711-001 7001-714-001 7001-718-001
7001-719-001 7001-726-000 7001-709-199 0250-013-000 0243-026-000 0332-006-000
0304-006-000
DESCRIPTION Wall Mounting Plate Bottle Filler with Pushbutton Operation Bottle Filler with Sensor Operation Bottle Filler with Sensor Operation & Bottle Counter Display Wide Contour Fountain Upper Trim Panel Assembly Lower Trim Panel Filter Assembly, 1,500 Gallons Filter Assembly, 3,000 Gallons Round Plug Bracket, Upper Trim Panel Support Wood Screw, #12 x 1-1/4″, Flat Head, S/S Stud, 5/16-18 UNC x 4″ Lg, Zinc Plated Flat Washer, 5/16 Zinc Plated Hex Nut, 5/16-18 UNC , Zinc Plated Steel
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 15 of 16
A192-BF
Member of
Date: 03/29/2024 A
CONTEMPDORRINAKRINYGWFAOTEURNTCAOINOSLERS INSTALLATION/MAINTENANCE INSTRUCTIONS
Optional -WF1 Water Filter
ITEM PART NUMBER
DESCRIPTION
1 7001-730-001 FILTER ENCLOSURE ASSY, 1,500 GALLONS
2 7001-728-002 FILTER ENCLOSURE
7
3 7012-309-001 WF1 FILTER, 1,500 GALLONS
4 2169-000-000 1/4″ OD TUBE, 3-1/2 FEET LONG
5 1895-709-000 ELBOW, 1/4″ OD PUSH-IN x 1/4″ OD STEM
6 7012-319-000 STRAP W/ BUCKLE
7 7012-313-000 REPLACEMENT CARTRIDGE
1
2
6 3 5 4
Optional -WF3 Water Filter
ITEM PART NUMBER
DESCRIPTION
1 7001-728-001 FILTER ENCLOSURE ASSY, 3,000 GALLONS
2 7001-728-002 FILTER ENCLOSURE
3 7012-333-001 WF3 FILTER, 3,000 GALLONS
4 2169-000-000 1/4″ OD TUBE, 3-1/2 FEET LONG
5 1895-709-000 ELBOW, 1/4″ PUSH-IN x 1/4″ OD STEM
7
6 7012-319-000 STRAP W/ BUCKLE
7 7012-318-000 REPLACEMENT CARTRIDGE
1
2
6 3 5 4
MURDOCK MFG. · 15125 Proctor Avenue · City of Industry, CA 91746 USA Phone 800-453-7465 or 626-333-2543 · www.murdockmfg.com
7021-031-001 Page 16 of 16
A192-BF
Member of
Date: 03/29/2024 A
References
- Drinking Fountains, Hydrants, Bottle Fillers & Hand Wash Stations - Murdock Manufacturing
- Terms and Warranty - Murdock Manufacturing
Read User Manual Online (PDF format)