LED2WORK 210200-06 Lamp Holder

Drawings

Structure of safety and supplementary information

Important instructions are marked with signal words or symbols in this operating manual. Some signal words denote the degree of the potential risk of injury. Colours and the different shades of grey and triangular symbols visually underline the degree of danger.

  • Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • Indicates a potentially hazardous situation which, if not avoided, could result in minor or slight injury.
  • Indicates a potentially hazardous situation which, if not avoided, could result in property damage.
  • Gives you additional information for the safe and efficient use of the product.
  • Refers to compliance with these operating instructions.
  • CE marking: confirms conformity with applicable standards and regulations.

Proper use

The light is used for illumination. A continuous operation is admissible. For connection values, see luminaire label and/or “Technical data”.
The supply cable is connected to the light via an M12 plug connection.

The safety information and all other information in this manual must be followed. Read the entire operating manual carefully before mounting and turning on.

For safe operation

The operating parameters of the LED light specified on the type plate must correspond to the supply parameters of the machine or of the switched-mode power supply.
Operate the light only in a mounted status.

Under no circumstances may the light be covered with cloths, foils or similar. Object distance the light-emitting surface should be at least 10 cm (3.94″).
Machines can emit voltage spikes due to various factors. These voltage spikes in the power supply via machines should be avoided: Only use regulated 24V DC switched-mode power supplies, not transformers with rectifiers, as these can give rise to voltage spikes due to inductance.
Hot plugging should be avoided (connection of the light to a power supply which is already connected to the mains), since this can lead to the destruction of the LED light.
LED lights react sensitively to high voltage transients if the necessary PSU are incorrectly selected. Choose a power supply solution that is adapted to your interference environ-ment.
Lights without grounding and with conductive housing supplied via safety extra low voltage (SELV – protection class III), smallest discharge currents may occur when contact is made. According to DIN VDE 0701 – 0702, this discharge current must be limited to a maximum of 0.5 mA. All corresponding products from LED2WORK GmbH fall significantly below this specification.

Safety information

Installation of electrical equipment may only be carried out by qualified electricians. Follow the five safety rules according to DIN VDE 0105. Failure to do so may result in damage to the LED light, as well as fire or other hazards.
Danger of electric shock!
Disconnect before working on the device or load. Ensure to disconnect all circuit breakers that supply dangerous voltages to the device or load, when doing so. Even when the device is switched off, the load is not galvanically isolated from the mains.
Only use the device if it is completely free of faults, and with safety and awareness in mind. If warnings or symbols are attached to the light, they must not be removed.

Assembly / Mounting

Check the LED light before installation to ensure it is complete and shows no signs of damage. Do not use the light or accessories if they are damaged, as there is a risk of injury.
The LED light comes fully assembled. The light is intended for mounting in optional light holders or mounting angles. As option there are this mounting accessories:

| Product no.
---|---
Light holder, Aluminium, pair| 210200-06
Luminaire bracket, VA, pair, light infinitely adjustable 110°| 210200-11
Luminaire bracket, VA, pair, with magnet| 210200-12
Light holder, VA, 1 pair, light adjustable ± 180°| 210200-14

When mounting the light, make sure that the luminaire is fastened securely and stably. If the light falls down, its weight poses a risk of injury!

Connection

Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK. PIN assignment of the M12 connector is as follows:

PIN assignment

  • PIN 1 = 24V DC
  • PIN 2 = not used
  • PIN 3 = GND
  • PIN 4 = 24V DC
  • PIN 5 = not used

PIN 3 = 0V DC. 24V DC for supply can be connected to PIN1 or PIN 4. It is not necessary to assign both PINs (PIN 1 and PIN 4) at once!
Through-wiring (cascadable): Via through-wiring (cascadable) allows the electrical connection of several lights provided for this purpose.
Cascadable: The total current consumption must not exceed 8 A DC at ta +30°C max.
(86°F max.) [… or 7 A DC at ta +40°C max. (104°F max..)].
The light is not equipped with a ON/OFF switch. Usually you switch the light ON or OFF via external switches of machines or systems.
Lights with cascading capability output +24V DC at PIN 4 and GND at PIN 3 of the output socket.

Maintenance and Care

The LED light is maintenance-free. Do not make any alterations to the light (except according to the mounting information contained in this manual).

  • Do not open the light!
    The LED light sources mounted in the light are connected to the light housing in a special way (thermal coupling) and may react sensitively to electrostatic discharges (ESD). Improper replacement of the illuminant or other components may impair the tightness of the luminaire. That is the reason why repairs may only be carried out by the manufacturer or by persons authorised and qualified by the manufacturer.
    Turn off the light before cleaning and let it cool down completely. Clean the outside of the luminaire with a soft, dry and clean cloth. To remove excess dirt, moisten the cloth with water. Never use aggressive cleaning agents, as these may cause discolouration of the housing.

  • No liability is assumed for damages resulting from the use of unsuitable cleaning agents.

Warranty

We supply a full warranty for the product for 36 months from the date of purchase. This warranty applies for fault-free working under proper use and in accordance with the operating instructions.
During the warranty period defects and faults in the product will be rectified free of charge if they are proven to be caused by material, processing or design errors. If the purchaser complains of a material defect, he bears the burden of proof to demonstrate that the product was already defective upon receipt.

The warranty does not extend to defects caused by wear, negligence or improper use.
Further claims, in particular claims for compensation for damage that did not occur on the LED light itself, are excluded.

Disposal

The light must be disposed of at a suitable disposal site designated for recycling of electrical and electronic equipment in accordance with local, national regulations. (WEEE-Reg.-Nr. DE 38003906)

Customer service

If you have any problems or questions concerning this product, please contact us!

  • By phone: +49 7231 44920-00
  • Monday to Thursday 8 am to 12 midday and 1 pm to 4:30 pm
  • Friday 8 am to 12 midday and 1 pm to 3 pm
  • By email: info@led2work.com

Technical data|
---|---
|
Connection values| 24V DC ±10 %
Class of protection| III
Beam angle (optics)| 100°
LED lifetime| > 60.000 h (L80/B10)
Operating temperature| -30… +70°C (-22… 158 °F)
System of protection| IP54
Technical safety inspection| DIN EN 62471
Light colour| 5200-5700K
Colour rendering| Ra ≥ 85
LED light| Product no.| Length A| Max. current| Max. power consumption
---|---|---|---|---
TUBELED_40 Element DC| 119010-02| 190 mm (7.48″)| 0,17 A| ~4 W
TUBELED_40 Element DC| 119110-02| 280 mm (11.02″)| 0,25 A| ~6 W
TUBELED_40 Element DC| 119210-02| 365 mm (14.37)| 0,33 A| ~8 W
TUBELED_40 Element DC| 119310-02| 540 mm (21.26″)| 1,54 A| ~13 W
TUBELED_40 Element DC| 119410-02| 715 mm (28.15″)| 0,79 A| ~19 W
TUBELED_40 Element DC| 119510-02| 1040 mm (40.94″)| 1,0 A| ~24 W
TUBELED_40 Element DC| 119610-02| 1540 mm (60.63″)| 1,54 A| ~37 W
TUBELED_40 Element DC, cascadable| 119010-12| 190 mm (7.48″)| 0,17 A| ~4 W
TUBELED_40 Element DC, cascadable| 119110-12| 280 mm (11.02″)| 0,25 A| ~6 W
TUBELED_40 Element DC, cascadable| 119210-12| 365 mm (14.37)| 0,33 A| ~8 W
TUBELED_40 Element DC, cascadable| 119310-12| 540 mm (21.26″)| 1,54 A| ~13 W
TUBELED_40 Element DC, cascadable| 119410-12| 715 mm (28.15″)| 0,79 A| ~19 W
TUBELED_40 Element DC, cascadable| 119510-12| 1040 mm (40.94″)| 1,0 A| ~24 W
TUBELED_40 Element DC, cascadable| 119610-12| 1540 mm (60.63″)| 1,54 A| ~37 W

Cascadable: The total current consumption must not exceed 8 A DC at ta +30°C max. (86°F max.) [… or 7 A DC at ta +40°C max. (104°F max..)].

Particulars according to the Regulation ErP 2019/2020/EU (Energy-Related Products)

2941-5000-00-LE-332e is a light source with energy efficiency class C

2941-5010-00-LE-83e is a light source with energy efficiency class C

Included light sources

Light Engine

Product no. 2941-5000-00-LE-332e 2941-5010-00-LE-83e
119010-02 0 2
119110-02 0 3
119210-02 1 0
119310-02 1 2
119410-02 2 0
119510-02 3 0
119610-02 4 2

Light Engine

__**Product no.**

| 2941-5000-00-LE-332e| 2941-5010-00-LE-83e
119010-12| 0| 2
119110-12| 0| 3
119210-12| 1| 0
119310-12| 1| 2
119410-12| 2| 0
119510-12| 3| 0
119610-12| 4| 2

EU Declaration of Conformity

Description of the electrical equipment:

  • Function: The LED light is used to light up a working area
  • Type/Model: TUBELED_40 Element DC
  • Item no.: 119010-ff, 119110-ff, 119210-ff, 119310-ff, 119410-ff, 119510-ff, 119610-ff
  • Year of manufacture: from October 2020

Conformity with other directives/regulations that apply to the product is declared:

  • 2014/30/EU EMC Directive dated 26.02.2014
  • 2014/35/EU Low Voltage Directive dated 26.02.2014
  • 2011/65/EU RohS Directive dated 08.06.2011
  • 2009/125/EG Ecodesign Directive dated 21.10.2009 with Regulation 2019/2020/EU
  • 1907/2006 Regulation (EC) No. 1907/2006 (REACH Directive) dated 1st June 2008; SVHC proportion >0.1%

Applied harmonised standards that have been applied:

  • DIN EN 55015:2016-04
  • DIN EN 61547:2010-03
  • DIN EN 60598-1:2015 + A1:2018
  • DIN EN 60529:2014-09
  • DIN EN 61347-1:2016-05
  • DIN EN 62471:2009-03
  • Year of the CE marking: 2022

This declaration of conformity shall lose its validity in the event that the product is modified or changed without our consent.
Pforzheim, 2022-04-28 Jan Schiga, Management Board

LED2WORK GmbH
Stuttgarter Str. 13 A
75179 Pforzheim | Germany
T +49 7231 44920-00
info@led2work.com

UK Declaration of Conformity

Description of the electrical equipment:

  • Function: The LED light is used to light up a working area
  • Type/Model: TUBELED_40 Element DC
  • Item no.: 119010-ff, 119110-ff, 119210-ff, 119310-ff, 119410-ff, 119510-ff, 119610-ff
  • Year of manufacture: from October 2020

Conformity with other directives/regulations that apply to the product is declared:

  • S.I. 2016 No. 1091 Electromagnetic Compatibility
  • S.I. 2016 No. 1101 Electrical Equipment (Safety) Regulations
  • S.I. 2012 No. 3032 Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
  • S.I. 2010 No. 2617 Ecodesign for Energy-Related Products Regulations

Applied harmonised standards that have been applied:

  • EN IEC 55015:2019/A11:2020
  • EN 61547:2009
  • EN 61000-3-2:2014
  • EN 61000-3-3:2013
  • EN 60598-1:2015 + A1:2018
  • EN 60529:1991/A2:2013/AC:2019-02
  • EN 61347-1:2015
  • EN 62471:2008

Year of the UKCA marking:
2022

This declaration of conformity shall lose its validity in the event that the product is modified or changed without our consent.
Pforzheim, 2022-09-28 Jan Schiga, Management Board

LED2WORK GmbH
Stuttgarter Str. 13 A
75179 Pforzheim | Germany
T +49 7231 44920-00
info@led2work.com

www.led2work.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals