Drawings
Structure of safety and supplementary information
Important instructions are marked with signal words or symbols in this operating manual. Some signal words denote the degree of the potential risk of injury. Colours and the different shades of grey and triangular symbols visually underline the degree of danger.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, could
result in minor or slight injury.
ATTENTION
Indicates a potentially hazardous situation which, if not avoided, could
result in property damage.
NOTE
Gives you additional information for the safe and efficient use of the
product.
Refers to compliance with these
operating instructions.
CE marking: confirms conformity with applicable standards and
regulations.
Proper use
The light is used for illumination. A continuous operation is admissible. For connection values, see luminaire label and/or “Technical data”. The power connection is made via the SCHUKO plug and cable at a 220–240V AC connection.
The safety information and all other information in this manual must be followed. Read the entire operating manual carefully before mounting and turning on.
For safe operation
The operating parameters of the LED light specified on the type plate must correspond to the supply parameters of the connection.
Operate the light only in a mounted status.
CAUTION
Under no circumstances may the light be covered with cloths, foils or
similar. Object distance the light-emitting surface should be at least 10 cm
(3.94″).
Danger of electric shock!
Disconnect before working on the device or load. Ensure to disconnect all
circuit breakers
that supply dangerous voltages to the device or load, when doing so. Even when
the
device is switched off, the load is not galvanically isolated from the
mains.When using the LED light in a supply network with 220-240V AC low
voltage, make sure that the running of cables is correctly. Supply
fluctuations plus xtreme surge voltages and burst voltages can destroy LED
modules, especially in the neighborhood of large electrical loads.
Safety information
WARNING
Installation of electrical equipment may only be carried out by qualified
electricians. Follow the five safety rules according to DIN VDE 0105. Failure
to do so may result in damage to the LED light, as well as fire or other
hazards.
DANGER
Danger of electric shock!
Disconnect before working on the device or load. Ensure to disconnect all
circuit breakers that supply dangerous voltages to the device or load, when
doing so. Even when the device is switched off, the load is not galvanically
isolated from the mains.
ATTENTION
Only use the device if it is completely free of faults, and with safety and
awareness in mind. If warnings or symbols are attached to the light, they must
not be removed.
Assembly / Mounting
Check the LED light before installation to ensure it is complete and shows no signs of damage. Do not use the light or accessories if they are damaged, as there is a risk of injury.
The LED light comes fully assembled. The light is mounting at the screw-on base with four screws M6 (in delivery scope). As option there are this mounting accessories:
Permanent Holding Magnet CENALED screw-on base: 220500-01
Table clamp CENALED screw-on base: 220500-02
Wall angle bracket CENALED screw-on base: 220500-03
CAUTION
When mounting the light, make sure that the luminaire is fastened securely
and stably. If the light falls down, its weight poses a risk of injury!
Connection
The light is connected with a 220–240V AC electric power supply system via the cable with SCHUKO plug.
ATTENTION
For the installation on the power supply system the light must be electrically load-free. This means that if the light is connected directly to a machine or a 220–240V AC power supply, these must be switched off and load-free for installation, otherwise the LEDs may be destroyed.
NOTE:
To turn on the light, activate the push button on top the head of the
light. Hold on the push button for setting of the light intensity. Another
pushing of the button turns the light off.
Maintenance and Care
The LED light is maintenance-free. Do not make any alterations to the light (except according to the mounting information contained in this manual).
Do not open the light!
ATTENTION
Do not open the light!
The LED light sources mounted in the light are connected to the luminaire housing in a special way (thermal coupling) and may react sensitively to electrostatic discharges (ESD). Improper replacement of the illuminant or other components may impair the tightness of the light. That is the reason why repairs may only be carried out by the manufacturers or by persons authorized and qualified by the manufacturer. Turn off the light before cleaning and let it cool down completely. Clean the outside of the light with a soft, dry and clean cloth. To remove excess dirt, moisten the cloth with water. Never use aggressive cleaning agents, as these may cause discoloration of the housing.
ATTENTION
No liability is assumed for damages resulting from the use of unsuitable
cleaning agents.
Warranty
We supply a full warranty for the product for 36 months from the date of purchase. This warranty applies for fault-free working under proper use and in accordance with the operating instructions.
During the warranty period defects and faults in the product will be rectified free of charge if they are proven to be caused by material, processing or design errors. If the purchaser complains of a material defect, he bears the burden of proof to demonstrate that the product was already defective upon receipt.
NOTE
The warranty does not extend to defects caused by wear, negligence or improper use.
Further claims, in particular claims for compensation for damage that did not occur on the LED light itself, are excluded.
Disposal
ATTENTION
The light must be disposed of at a suitable disposal site designated for recycling of electrical and electronic equipment in accordance with local, national regulations. (WEEE-Nr. 32828318)
Customer service
If you have any problems or questions concerning this product, please contact us!
By phone: +49 7231 44920-00
Monday to Thursday: 8 am to 12 midday and 1 pm to 4:30 pm
Friday: 8 am to 12 midday and 1 pm to 3 pm
By email: info@led2work.com
Technical data
Connection values: 100–305V AC, 50-60 Hz
Class of protection: I (protective grounding)
Beam angle (optics): 30°
LED lifetime: > 60.000 h (L80/B10)
Operating temperature: -10… +50°C (14… 122°F)
System of protection: IP67 (head), IP65 (screw-on base)
Technical safety inspection: DIN EN 62471
Light colour: 5000K
Colour rendering: Ra ≥ 80
LED light: CENALED SPOT AC Flexarm
Product no: ~9 W
Max. power consumption: 121012-11