LED2WORK Tubeled 40 Element Ac LED Surface Mounted Light Instruction Manual

June 12, 2024
LED2WORK

LED2WORK-LOOG

Tubeled 40 Element Ac LED Surface Mounted Light

LED2WORK-Tubeled-40-Element-Ac-LED-Surface-Mounted-Light-PRODUCT-
IMAGE

Product Information

  • Product Name: TUBELED_40 Element AC
  • Model: BA TUBELED_40 Element AC
  • Input Voltage: 230V AC
  • Manufacturer: LED2WORK
  • Year of Manufacture: 2014
  • Compliance: EU Directive 2014/35/EU

Product Usage Instructions

For safe operation:

  • Read the entire operating manual carefully before mounting and turning on the luminaire.

Safety information

  • Follow all safety instructions and information provided in the operating manual.

Assembly/Mounting:

  • Ensure that the luminaire is securely and stably mounted to prevent it from falling down, as it can cause injuries due to its weight.

Connection:

  • The luminaire is connected to the power supply via an M12 plug connection. Refer to the luminaire label and/or Technical data for connection values.

Maintenance and Care:

  • Regularly maintain and clean the luminaire as per the instructions provided in the operating manual.

Disposal:

  • Follow proper disposal procedures for the luminaire in accordance with local regulations.

Customer Service:

  • If you have any problems or questions regarding this product, please contact LED2WORK customer service:
  • Phone: +49 7231 44920-00 (Monday to Thursday: 8:00 AM to 12:00 PM and 1:00 PM to 4:30 PM, Friday: 8:00 AM to 12:00 PM and 1:00 PM to 3:00 PM)
  • Email: [email protected]

Technical Data:

Product Variant Article Number Power Consumption
TUBELED_40 Element AC 119110-03 ~8.5 W
TUBELED_40 Element AC 119310-03 ~17 W
TUBELED_40 Element AC 119510-03 ~34 W
TUBELED_40 Element AC 119610-03 ~51 W

Drawings

LED2WORK-Tubeled-40-Element-Ac-LED-Surface-Mounted-
Light-01

Structure of safety and supplementary information

Important instructions are marked with signal words or symbols in this operating manual. Some signal words denote the degree of the potential risk of injury. Colours and the different shades of grey and triangular symbols visually underline the degree of danger.

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, could result in minor or slight injury.
ATTENTION: Indicates a potentially hazardous situation which, if not avoided, could result in property damage.
NOTE: Gives you additional information for the safe and efficient use of the product.
Refers to compliance with these operating instructions.
CE: CE marking: confirms conformity with applicable standards and regulations.

Proper use
The luminaire is used for illumination. A continuous operation is admissible. For connection values, see luminaire label and/or “Technical data”.
The supply cable is connected to the luminaire via an M12 plug connection.

The safety information and all other information in this manual must be followed. Read the entire operating manual carefully before mounting and turning on.

For safe operation
The operating parameters of the LED luminaire specified on the type plate must correspond to the supply parameters of the connection.
Operate the luminaire only in a mounted status.

CAUTION: Under no circumstances may the luminaire be covered with cloths, foils or similar. Object distance the light-emitting surface should be at least 10 cm.
ATTENTION: During the operation of the luminaire in a 220-240V power supply net, it could be the cause, that machines (induction perpetrators) inside the same power supply net cause interference spikes at start. This deviations may only 10% max.
ATTENTION: Hot plugging should be avoided, since this can lead to the destruction of the LED luminaire.

Safety information

WARNING: Installation of electrical equipment may only be carried out by qualified electricians. Follow the five safety rules according to DIN VDE 0105. Failure to do so may result in damage to the LED luminaire, as well as fire or other hazards.
DANGER: Danger of electric shock!
Disconnect before working on the device or load. Ensure to disconnect all circuit breakers that supply dangerous voltages to the device or load, when doing so. Even when the device is switched off, the load is not galvanically isolated from the mains.
ATTENTION: Only use the device if it is completely free of faults, and with safety and awareness in mind. If warnings or symbols are attached to the luminaire, they must not be removed.

Assembly / Mounting

Check the LED luminaire before installation to ensure it is complete and shows no signs of damage. Do not use the luminaire or accessories if they are damaged, as there is a risk of injury.

The LED luminaire comes fully assembled. The luminaire is intended for mounting in optional luminaire holders or mounting angles. As option there are this mounting accessories:

  Product no.
Luminaire holder, Aluminium, pair 210200-06
Luminaire bracket, VA, pair, luminaire infinitely adjustable 110° 210200-11
Luminaire bracket, VA, pair, with magnet 210200-12
Luminaire holder, VA, 1 pair, luminaire adjustable ± 180° 210200-14

CAUTION: When mounting the luminaire, make sure that the luminaire is fastened securely and stably. If the luminaire falls down, its weight poses a risk of injury!

Connection

On the luminaire is an input for about a M12 connector S-type encoded. About this jack and with suitable connection material the luminaire is connected with a 220–240V AC electric power supply system.
Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK.

PIN assignment of the M12 connector is as follows:

LED2WORK-Tubeled-40-Element-Ac-LED-Surface-Mounted-
Light-03 Schematic drawing of M12 S-type encoded

PIN assignment

PIN 1 = not connected brown
PIN 2 = external conductor/phase (L) black
PIN 3 = neutral conductor (N) blue
PIN 4 = protective earth conductor (PE) green/yellow

ATTENTION: For the installation on the power supply system the luminaire must be electrically load-free. This means that if the luminaire is connected directly to a machine or a 220–240V AC power supply, these must be switched off and load-free for installation, otherwise the LEDs may be destroyed.

Maintenance and Care

The LED luminaire is maintenance-free. Do not make any alterations to the luminaire (except according to the mounting information contained in this manual).

ATTENTION: Do not open the luminaire!

The LED light sources mounted in the luminaire are connected to the luminaire housing in a special way (thermal coupling) and may react sensitively to electrostatic discharges (ESD). Improper replacement of the illuminant or other components may impair the tightness of the luminaire. That is the reason why repairs may only be carried out by the manufacturer or by persons authorized and qualified by the manufacturer.
Turn off the light before cleaning and let it cool down completely. Clean the outside of the luminaire with a soft, dry and clean cloth. To remove excess dirt, moisten the cloth with water. Never use aggressive cleaning agents, as these may cause discoloration of the housing.

ATTENTION: No liability is assumed for damages resulting from the use of unsuitable cleaning agents.

Warranty

We supply a full warranty for the product for 36 months from the date of purchase. This warranty applies for fault-free working under proper use and in accordance with the operating instructions.
During the warranty period defects and faults in the product will be rectified free of charge if they are proven to be caused by material, processing or design errors. If the purchaser complains of a material defect, he bears the burden of proof to demonstrate that the product was already defective upon receipt.

NOTE: The warranty does not extend to defects caused by wear, negligence or improper use.
Further claims, in particular claims for compensation for damage that did not occur on the LED luminaire itself, are excluded.

Disposal
The luminaire must be disposed of at a suitable disposal site designated for recycling of electrical and electronic equipment in accordance with local, national regulations. (WEEE-Nr. 32828318)

Customer service
If you have any problems or questions concerning this product, please contact us!

  • By phone: +49 7231 44920-00
  • Monday to Thursday 8 am to 12 midday and 1 pm to 4:30 pm
  • Friday 8 am to 12 midday and 1 pm to 3 pm
  • By email: [email protected]

Technical data

  • Connection values 220–240V AC, 50-60 Hz
  • Class of protection I (protective grounding)
  • Beam angle (optics) 100°
  • LED lifetime > 50.000 h (L80/B10)
  • Operating temperature -30… +50 °C
  • System of protection IP54
  • Technical safety inspection DIN EN 62471
  • Light color 5200-5700K
  • Color rendering Ra ≥ 80

LED luminaire| Product no.| Length A| Max. power consumption
---|---|---|---
TUBELED_40 Element AC| 119110-03| 280 mm| ~8,5 W
TUBELED_40 Element AC| 119310-03| 540 mm| ~17 W
TUBELED_40 Element AC| 119510-03| 1040 mm| ~34 W
TUBELED_40 Element AC| 119610-03| 1540 mm| ~51 W

Particulars according to the Regulation ErP 2019/2020/EU (Energy-Related Products)

2941-5030-00-LE-249AC is a light source with energy efficiency class E

Included light sources:

LED2WORK-Tubeled-40-Element-Ac-LED-Surface-Mounted-
Light-06

EU Declaration of Conformity

Description of the electrical equipment:

  • Function: The LED light is used to light up a working area
  • Type/Model: TUBELED_40 Element AC
  • Item no.: 119110-03, 119310-03, 119510-03, 119610-03
  • Year of manufacture: from October 2020

Conformity with other directives/regulations that apply to the product is declared:

  • 2014/30/EU EMC Directive dated 26.02.2014
  • 2014/35/EU Low Voltage Directive dated 26.02.2014
  • 2011/65/EU RohS Directive dated 08.06.2011
  • 2009/125/EG Ecodesign Directive dated 21.10.2009 with Regulation 2019/2020/EU
  • 1907/2006 Regulation (EC) No. 1907/2006 (REACH Directive) dated 1st June 2008; SVHC proportion >0.1%

Applied harmonized standards that have been applied:

  • DIN EN 55015:2016-04
  • DIN EN 61547:2010-03
  • DIN EN 60598-1:2015 + A1:2018
  • DIN EN 60529:2014-09
  • DIN EN 61347-1:2016-05
  • DIN EN 62471:2009-03

Year of the CE marking:
2022

This declaration of conformity shall lose its validity in the event that the product is modified or changed without our consent.

Pforzheim, 2022-04-28  Jan Schiga, Management Board

LED2WORK GmbH
Stuttgarter Str. 13 A 75179 Pforzheim | Germany
T +49 7231 44920 -00 [email protected]

UK Declaration of Conformity

Description of the electrical equipment:

  • Function: The LED light is used to light up a working area
  • Type/Model: TUBELED_40 Element AC
  • Item no.: 119110-03, 119310-03, 119510-03, 119610-03
  • Year of manufacture: from October 2020

Conformity with other directives/regulations that apply to the product is declared:

  • S.I. 2016 No. 1091 Electromagnetic Compatibility
  • S.I. 2016 No. 1101 Electrical Equipment (Safety) Regulations
  • S.I. 2012 No. 3032 Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
  • S.I. 2010 No. 2617 Ecodesign for Energy-Related Products Regulations

Applied harmonised standards that have been applied:

  • EN IEC 55015:2019/A11:2020
  • EN 61547:2009
  • EN 61000-3-2:2014
  • EN 61000-3-3:2013
  • EN 60598-1:2015 + A1:2018
  • EN 60529:1991/A2:2013/AC:2019-02
  • EN 61347-1:2015
  • EN 62471:2008

Year of the UKCA marking: 2022

This declaration of conformity shall lose its validity in the event that the product is modified or changed without our consent.

Pforzheim, 2022-09-28 Jan Schiga, Management Board

LED2WORK GmbH
Stuttgarter Str. 13 A 75179 Pforzheim | Germany
T +49 7231 44920 -00
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LED2WORK User Manuals

Related Manuals