LED2WORK CENALED SPOTDC LED Flexarm Light Instruction Manual

June 1, 2024
LED2WORK

LED2WORK-logo

LED2WORK CENALED SPOTDC LED Flexarm Light

LED2WORK-CENALED-SPOTDC-LED-Flexarm-Light-product-
image

Specifications

  • Product Name: CENALED SPOT DC Flexarm
  • Model Number: BA 01/2024
  • Power Consumption: ~8.5 W
  • Operating Voltage: +24V DC

Product Information

The CENALED SPOT DC Flexarm is an LED light designed for illumination purposes. It is suitable for continuous operation and must be operated according to the specified parameters.

Product Usage Instructions

  1. Proper Use
    The light is intended for illumination purposes and can be used continuously. Ensure that the connection values match the luminaire label and technical data provided.

  2. For Safe Operation
    Operate the LED light only when securely mounted. Verify that the operating parameters on the type plate align with the supply parameters of the machine or power supply.

  3. Safety Information
    Follow all safety instructions outlined in the manual. Pay attention to signal words, symbols, and visual cues that indicate the level of risk. Ensure thorough reading of the manual before installation and operation.

  4. Assembly/Mounting
    When mounting the light, ensure it is securely and stably fixed to prevent any risks of injury due to falling. Refer to the specific mounting instructions provided.

  5. Connection
    Connect the brown cable to +24V DC and the black cable to GND as per the provided guidelines.

  6. Maintenance and Care
    Regular maintenance is essential for optimal performance. Keep the light clean and free from dust accumulation. Refer to maintenance instructions for detailed guidance.

FAQ

Q: What should I do if I have issues with the product?
A: For problems or queries related to the product, please contact us through phone or email during our working hours.

  • Phone: +49 7231 44920-00 (Mon-Thurs: 8:00-12:00 & 13:00-16:30, Fri: 8:00-12:00 & 13:00-15:00)
  • Email: [email protected]

Drawings

LED2WORK-CENALED-SPOTDC-LED-Flexarm-Light-fig- \(1\)

Structure of safety and supplementary information

Important instructions are marked with signal words or symbols in this operating manual. Some signal words denote the degree of the potential risk of injury. Colours and the different shades of grey and triangular symbols visually underline the degree of danger.

  • Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • Indicates a potentially hazardous situation which, if not avoided, could result in minor or slight injury.
  • Indicates a potentially hazardous situation which, if not avoided, could result in property damage.
  • Gives you additional information for the safe and efficient use of the product.
  • Refers to compliance with these operating instructions.
  • CE marking: confirms conformity with applicable standards and regulations. ETL-safety test seal for North America: Proof of compliance with standards in the USA and Canada: e.g. UL, CSA, NEC, NFPA, NSF, ANSI and NOM.

Proper use

  • The light is used for illumination. A continuous operation is admissible. For connection values, see luminaire label and/or “Technical data”.
  • The safety information and all other information in this manual must be followed. Read the entire operating manual carefully before mounting and turning on.

For safe operation

  • The operating parameters of the LED light specified on the type plate must correspond to the supply parameters of the machine or of the switched-mode power supply.
  • Operate the light only in a mounted status.
  • Caution Under no circumstances may the light be covered with cloths, foils or similar. Object distance the light-emitting surface should be at least 10 cm (3.94″).
  • Attention Machines can emit voltage spikes due to various factors. These voltage spikes in the power supply via machines should be avoided: Only use regulated 24V DC switched-mode power supplies, not transformers with rectifiers, as these can give rise to voltage spikes due to inductance.
  • Hot plugging should be avoided (connection of the light to a power supply which is already connected to the mains), since this can lead to the destruction of the LED light.
  • Attention LED lights react sensitively to high voltage transients if the necessary PSU are incorrectly selected. Choose a power supply solution that is adapted to your interference environment.
  • Note Lights without grounding and with conductive housing supplied via safety extra low voltage (SELV – protection class III), smallest discharge currents may occur when contact is made. According to DIN VDE 0701 – 0702, this discharge current must be limited to a maximum of 0.5 mA. All corresponding products from LED2WORK GmbH fall significantly below this specification.

Safety information

  • Warning Installation of electrical equipment may only be carried out by qualified electricians. Follow the five safety rules according to DIN VDE 0105. Failure to do so may result in damage to the LED light, as well as fire or other hazards.
  • Danger   Danger of electric shock!
  • Disconnect before working on the device or load. Ensure to disconnect all circuit breakers that supply dangerous voltages to the device or load, when doing so. Even when the device is switched off, the load is not galvanically isolated from the mains.
  • Attention Only use the device if it is completely free of faults, and with safety and awareness in mind. If warnings or symbols are attached to the light, they must not be removed.

Assembly / Mounting

Check the LED light before installation to ensure it is complete and shows no signs of damage. Do not use the light or accessories if they are damaged, as there is a risk of injury.
The LED light comes fully assembled. The light is mounting at the screw-on base with four screws M6 (in delivery scope). As option there are this mounting accessories:

| Product no.
---|---
Permanent Holding Magnet CENALED screw-on base| 220500-01
Table clamp CENALED screw-on base| 220500-02
Wall angle bracket CENALED screw-on base| 220500-03

Caution
When mounting the light, make sure that the luminaire is fastened securely and stably. If the light falls down, its weight poses a risk of injury!

Connection

  • The direct current LED light has a sensor cable of three meters, PVC oil resistant, and two open cable ends for a direct connection to a machine control for example.
    • cable strand, brown +24V DC
    • cable strand, black GND
  • For further connection options, like cables, plugs or materials you can find in the accessories of LED2WORK.

Note
To turn on the light, activate the push button on top the head of the light. Hold on the push button for setting of the light intensity. Another pushing of the button turns the light off.

Maintenance and Care

  • The LED light is maintenance-free. Do not make any alterations to the light (except according to the mounting information contained in this manual).
  • Attention Do not open the light!
  • The LED light sources mounted in the light are connected to the luminaire housing in a special way (thermal coupling) and may react sensitively to electrostatic discharges (ESD).
  • Improper replacement of the illuminant or other components may impair the tightness of the light. That is the reason why repairs may only be carried out by the manufacturer or by persons authorised and qualified by the manufacturer.
  • Turn off the light before cleaning and let it cool down completely. Clean the outside of the light with a soft, dry and clean cloth. To remove excess dirt, moisten the cloth with water.
  • Never use aggressive cleaning agents, as these may cause discoloration of the housing.
  • Attention No liability is assumed for damages resulting from the use of unsuitable cleaning agents.

Warranty

  • We supply a full warranty for the product for 36 months from the date of purchase. This warranty applies for fault-free working under proper use and in accordance with the operating instructions.
  • During the warranty period defects and faults in the product will be rectified free of charge if they are proven to be caused by material, processing or design errors. If the purchaser complains of a material defect, he bears the burden of proof to demonstrate that the product was already defective upon receipt.

Note

  • The warranty does not extend to defects caused by wear, negligence or improper use.
  • Further claims, in particular claims for compensation for damage that did not occur on the LED light itself, are excluded.

Disposal

Attention
The light must be disposed of at a suitable disposal site designated for recycling of electrical and electronic equipment in accordance with local, national regulations. (WEEE-Nr. 32828318)

Customer service

If you have any problems or questions concerning this product, please contact us!

  • By phone: +49 7231 44920-00
  • Monday to Thursday 8 am to 12 midday and 1 pm to 4:30 pm
  • Friday 8 am to 12 midday and 1 pm to 3 pm
  • By email : [email protected]

Technical data

  • Connection values 24V DC ±10 %
  • Class of protection III
  • Beam angle (optics) 30°
  • LED lifetime >60.000 h (L80/B10)
  • Operating temperature – 10… +50°C (14… 122°F)
  • System of protection IP67
  • Technical safety inspection DIN EN 62471
  • Light colour 5000K
  • Colour rendering Ra ≥ 80

LED light| Product no.| Max. current| Max. power consumption
---|---|---|---
CENALED SPOT DC Flexarm| 121012-01| 0,35 A| ~8,5 W

Particulars according to the Regulation ErP 2019/2020/EU (Energy-Related Products)
2941-5040-00-LE-55×55 is a light source with energy efficiency class E

Included light sources:

Light Engine

Art.-Nr.|  |
Product no.

N° d’article

| P SB| 2941-5040-00-LE-55×55
Nº de artículo| |
Articolo no.| |
121012-01| < 0,1 W| 1

Standby power PSB in connected condition Puissance

EU Declaration of Conformity

  • Function:  The LED light is used to light up a working area
  • Type/Model: CENALED SPOT DC Flexarm
  • Item no.: 121012-01
  • Year of manufacture: from April 2021
  • Conformity with other directives/regulations that apply to the product is declared:
    • 2014/30/EU EMC Directive dated 26.02.2014
    • 2014/35/EU Low Voltage Directive dated 26.02.2014
    • 2011/65/EU RohS Directive dated 08.06.2011
    • 2009/125/EG Ecodesign Directive dated 21.10.2009 with Regulation 2019/2020/EU
    • 1907/2006 Regulation (EC) No. 1907/2006 (REACH Directive) dated 1st June 2008; SVHC proportion >0.1%
  • Applied harmonised standards that have been applied:
    • DIN EN 55015:2016-04
    • DIN EN 61547:2010-03
    • DIN EN 60598-1:2015 + A1:2018
    • DIN EN 60529:2014-09
    • DIN EN 61347-1:2016-05
    • DIN EN 62471:2009-03

Year of the CE marking:
2022

This declaration of conformity shall lose its validity in the event that the product is modified or changed without our consent.

Pforzheim, 2022-04-28 Jan Schiga, Management Board

LED2WORK GmbH
Stuttgarter Str. 13 A 75179 Pforzheim | Germany
T +49 7231 44920 -00 [email protected]
www.led2work.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LED2WORK User Manuals

Related Manuals