“`html
Specifications:
- Lifetime warranty on body
- 2 years warranty on vacuum motors and pump
- 1 year warranty on heater and all electrical parts
- 90 days warranty on tools and accessories
- 3-Gallon Capacity
- Manufactured in the U.S.A.
Product Usage Instructions:
Warranty Information:
The product comes with a comprehensive warranty covering
different components for varying periods. It is important to adhere
to the warranty terms to ensure coverage in case of any issues.
Machine Registration:
Make sure to complete and return the Machine Registration Card
immediately after purchase to establish the warranty start date.
Proof of purchase is required for warranty validation.
Safety Instructions:
Before using the product, carefully read the Safety, Operation,
and Maintenance Manual provided. Ensure you understand all safety
precautions to prevent accidents.
Product Maintenance:
Regular maintenance of the machine is essential for optimal
performance and longevity. Refer to the Parts List for guidance on
replacement parts and maintenance procedures.
Usage Guidelines:
Follow the recommended guidelines for operating the 3-Gallon
Spot Extractor Series. Avoid misuse or abuse of the machine to
prevent voiding the warranty on motors and associated
components.
FAQ:
What does the warranty cover?
The warranty covers lifetime protection on the body, 2 years on
vacuum motors and pump, 1 year on heater and electrical parts, and
90 days on tools and accessories.
Where can I get labor services under warranty?
Labor services are provided only by a CleanFreak Repair Center.
If one is not nearby, it is the purchaser’s responsibility to
transport the machine to a designated repair center.
“`
New Equipment Warranty
Limited Warranty
CleanFreak warrants new equipment against defects in material and workmanship
under normal use and service to the original purchaser. Any statutory implied
warranties, including any warranty of merchantability or fitness for a
particular purpose, are expressly limited to the duration of this written
warranty. CleanFreak will not be liable for any other damages, including but
not limited to indirect or special consequential damages arising out of or in
connection with the furnishing, performance, use or inability to use the
machine. This remedy shall be the exclusive remedy of the purchaser. The
warranty period is subject to the conditions stated below.
Lifetime Warranty on Body, 2 Years on Vacuum Motors and Pump, 1 Year on Heater
and on all Electrical Parts, 90 Days on Tools and Accessories
CleanFreak warrants the roto-molded body to be free from defects in material
and workmanship, under normal use and service for a lifetime. CleanFreak
warrants the motors and pump to be free from defects in material and
workmanship, under normal use and proper maintenance service for two (2) years
from the original date of sale, heater for one (1) year and all electrical
parts one (1) year. Parts replaced or repaired under this warranty are
warranted for the remainder of the original warranty period. Service labor
charges are covered for one (1) year from the date of purchase, when performed
by a CleanFreak Repair Center.
Labor is only provided by a CleanFreak Repair Center. If a CleanFreak Repair
Center is not near you, it is the purchaser’s responsibility to take their
machine to a CleanFreak Repair Center.
Normal wear items, such as capacitors, cords, finishes or switches, will be
warranted for manufacturing defects for ninety (90) days from the purchase
date.
All warranties of motors and associated components will be voided: if the
machine is serviced by anyone other than a CleanFreak Repair Center; if the
machine is mechanically modified; if the machine is operated when not
operating properly; or if the machine is misused or abused.
The warranty starts on the purchase date by the original purchaser from
CleanFreak subject to proof of purchase. The Machine Registration Card must be
completed and returned immediately at the time of purchase. If proof of
purchase cannot be identified, the warranty start date is ninety (90) days
after the inventory stocking date at the distributor’s warehouse.
5109 N National Dr, Knoxville, TN 37914 Toll Free:
888-722-5508 | Local:
920-882-8453
www.CleanFreak.com
Make a copy of this card for future reference.
© All Rights Reserved
Safety, Operation and Maintenance Manual with Parts List
Please read before use!
3-Gallon Capacity
Important Information and Safety Instructions
Serial No: _____
Manufactured with Pride in the U.S.A.
© All Rights Reserved
3-Gallon Spot Extractor Series
Notes:
Dear Valued Client,
Congratulations on the purchase of your 3-Gallon Spot Extractor carpet and
upholstery machine! The world of carpet cleaning is becoming more high-tech
and competitive and we strive to provide you with the most innovative
products. Our spot extractor with heat is yet another example of this,
bringing a new dimension to carpet and upholstery cleaning with its cutting-
edge features, quality and value. Please review this manual, paying careful
attention to the Safety Instructions section. Keep in mind that any
unnecessary damage, neglect or abuse of this machine will void your warranty.
You can be confident that simple maintenance will ensure that your spot
extractor with heat provides quality performance for many years to come. If
warranty questions arise, please consult your manual or contact your
CleanFreak representative Should you have any questions regarding maintenance,
replacing parts or ordering parts, please call your CleanFreak representative.
Before you begin using your Spot Extractor, please thoroughly review the
Owner’s Manual. Again, congratulations on the purchase of your 3-Gallon Spot
Extractor carpet and upholstery machine!
Questions or Comments?
Phone: 920-882-8453 Toll Free:
888-722-5508 Fax:
920-380-0878 Mailing Address: 5109 N
National Dr, Knoxville, TN 37914 Visit our Web site at www.CleanFreak.com
(2) 3-Gallon Spot Extractor Series
11.0 Machine Parts List Continued – with Heat
Drawing No.
65
66
67 68 69 70 71
Item ID
10-0027
10-0448
10-0025 10-1026 10-0400-C 80-0022-A 10-0204
Item Description
Pigtail Strain Relief
20-Foot Spotter/Air Mover Cord
On/Off Switch Switch Plate for 3-Gallon w/ Heat Keeper Latch for Sniper Screw
for 500 PSI Panel Motor Mount Back-Up Washer
Qty. Needed
1.00
1.00
3.00 1.00 1.00 2.00 2.00
12.0 Hoses and Hand Tool Drawing and Parts List
10-0501 Stainless Steel Hand Tool for Machines with Heat
Parts List
Drawing No. 1 2 3 4 5 6 7 8 9 10 11
Item No.
10-0501 10-0463 50-1008 10-0868
80-8007 10-0388 10-0870
10-0507 10-0506 10-0504 10-0502
(14) 3-Gallon Spot Extractor Series
Item Description
4″ Stainless Steel Upholstery Tool Black Slip Hose Cuff for Spotter 15-Foot
Black Hose 1-1/4″ 1/4″ Female QD for Spotter
1/4″ x 15-Foot Extractor Hose Velcro Strap 1/4″ Male QD
8″ Black Hose for Stainless Steel Hand Tool Valve Clamp for Stainless Steel
Hand Tool Valve for Stainless Steel Hand Tool Jet for Stainless Steel Hand
Tool
Qty. Needed
1.00 2.00 1.00 1.00
1.00 1.00 1.00
1.00 1.00 1.00 1.00
New Equipment Warranty
Lifetime on body, 2 years on vacuum motors and pump, 1 year on heater and on
all electrical components, 90 days on tools and accessories.
Warranty Policy
All equipment is inspected and tested before shipping from the manufacturer.
All parts are warranted to be new and free from defects in workmanship and
material, under normal use to the original retail purchaser. This warranty
limits manufacturer’s liability for defects in workmanship or materials for
replacement of defective parts only. Manufacturer accepts no liability for
incidental or consequential damages arisen from the use of any equipment,
defective or not. This warranty is in lieu of all expressed or implied
warranties and is extended only to the original retail purchaser. Manufacturer
sales and service representatives are not authorized to waive or alter the
terms of this warranty, or to increase the obligations of the manufacturer
under the warranty. Parts replaced or repaired under warranty are warranted
for the remainder of the original warranty period.
Freight charges shall be covered for ninety (90) days from the original
purchase date. After this ninety (90) day period, freight charges shall be
paid by the equipment owner, subject to manufacturer discretion. Certain
circumstances may require additional consideration.
Manufacturer covers up to 1-year (365 days) of service labor at manufacturer’s
calculated hourly labor rate/repair time when performed by a manufacturer’s
authorized-service provider. Ultimately, labor reimbursement costs are at the
discretion of the manufacturer. After 1-year, the original retail purchaser is
responsible for all labor costs with no manufacturer reimbursement.
Manufacturer charges a 15% restocking fee for any items that are being
returned to stock. Items must be new, unused and free of damage. Only good for
up to 1-year (365 days). After 1-year, manufacturer does not accept the return
of any item(s) for a reimbursed price. Authorized warranty replacement parts
need to come directly from the manufacturer. Use of any other parts will void
warranty. Manufacturer does not reimburse for parts used by the customer that
were not supplied directly for the machine under warranty.
Returned Material Authorization (RMA) Procedure
Original purchaser (distributor/service center) must contact the manufacturer
to follow correct RMA/warranty procedures. Must include a copy of RMA Sheet
enclosed in the box with returned item. No returns shall be authorized unless
proper RMA procedures are followed. It is the responsibility of the
distributor to repair the customer’s equipment as soon as possible. If the
distributor does not have the facilities to repair the equipment, it may be
shipped or taken to an authorized service center for repair.
Customer must contact the distributor prior to working on or changing out any
parts, etc. Manufacturer must issue an RMA Sheet containing approved labor
time and replacement parts. Do not send parts or equipment back to
manufacturer without an RMA number and approval. No labor will be paid for,
nor part costs paid for or reimbursed that have not been previously approved
by the manufacturer. All warranty work must be approved and authorized to
qualify and appropriate warranty procedures must be followed.
3-Gallon Spot Extractor Series (3)
Table of Contents
New Equipment Warranty……………………………………………………………………………………………………….3 Returned
Material Authorization (RMA) Procedure…………………………………………………………….3 1.0 Safety
Instructions …………………………………………………………………………………………………………….5 2.0 Set-Up/Prepare
Unit for Use…………………………………………………………………………………………….5 3.0 How to Use 3-Gallon
Spotter ………………………………………………………………………………………….6 4.0 Preventative Instructions for
Heater Use……………………………………………………………………….7 5.0 Maintenance
………………………………………………………………………………………………………………………8 6.0 Grounding
Instructions…………………………………………………………………………………………………….8 7.0 Machine Schematic
Drawing – No Heat …………………………………………………………………………9 8.0 Machine Parts List – No
Heat ……………………………………………………………………………………….. 10 9.0 Hoses and Hand Tool Drawing
and Parts List (Clear)………………………………………………… 11 10.0 Machine Schematic Drawing –
Heat………………………………………………………………………….. 12 11.0 Machine Parts List –
Heat………………………………………………………………………………………..13-14 12.0 Hoses and Hand Tool Drawing
and Parts List (Stainless Steel)……………………………… 14
(4) 3-Gallon Spot Extractor Series
11.0 Machine Parts List – with Heat
Drawing No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
45 46 47 48 49 50 51 52 53 54 55 56 57 58 59
60 61 63 64 65
Item ID
SP-3-ST-BLKGRAN SP-3-RT-GRNGRAN 10-0383 10-0400-D 10-0412 10-0414 10-0384
10-0385 10-0074 10-0216 10-0379 10-0405 10-0302-A 10-0416-A 10-0304 10-0419
SP-3-HS-BLKGRAN 10-0831 10-0832 10-0300 10-0403-M 10-0901 10-0510 80-0017
80-0024-B 10-0826 10-0843 10-0434 10-0407 10-0845-2 10-0301 10-0828 10-0022
10-0017 T-C-011 T-WPUR 80-0011-2 80-0010 10-0843 10-0852 80-0101-M 80-0014
10-0479 10-0870
10-1500-B 10-0814 10-0814-B 10-0907 10-0906 10-0900 10-0801-G SP-3-H-BLK
10-0387 10-0303 10-0822 10-0419-A 10-0014 10-0380 10-1024
10-0354 10-0386 10-1030 10-0027-A T-WBLA
Item Description
Qty. Needed
3-Gallon Solution Tank – Black Granite
1.00
3-Gallon Recovery Tank – Green Granite
1.00
6-32 x 1/4″ Phil Pan Screw
6.00
Latch for Sniper
1.00
C-Channel for Spotter Handle
2.00
Rivet for Spotter Handle
4.00
.125 Thick Nylon Washer
4.00
.06 Thick Nylon Washer
4.00
Flat Washer #8 SAE
11.00
Allen Head Screw for Backpack
4.00
8-32 x 3/8″ Screw
4.00
1-1/2″ PVC SCH40 Slip Thread
1.00
Hatch Cover Gasket for Spotter
1.00
1-1/2″ Black ABS Stand Pipe
1.00
Spotter Cap and Float Assembly
1.00
Screw for Spotter Hatch
6.00
3-Gallon Heater Skirt – Black Granite
1.00
S/R Bracket for Sniper
1.00
S/R Strap Bolts
2.00
55 PSI Pump for Spotter
1.00
1/8″ Brass Male Nipple
1.00
175 PSI Relief Valve for Heater
1.00
1/8″ Brass Plug
1.00
Bulk Head fitting for Sniper
2.00
1/4″ MPT x 3/8″ Barb
4.00
3/4″ Hose Clamp for Sniper
6.00
3/8″ Black Hose for Sniper
1.00
Threaded Hose for Spotter
1.00
1/8″ Strait Nylon Barb NPT
2.00
1/8″ Strainer for Spotter
1.00
L Bracket for Spotter
1.00
90 Degree Brass Fitting for Sniper
1.00
Shoulder and Waist Belt Screw
3.00
Deflector Screw
1.00
Female Terminal Connector
10.00
Purple Wire
90 Degree Street Elbow
1.00
1/4″ Brass Tee
1.00
3/8″ Black Hose for Sniper
1.00
1/4″ 90 Degree Brass Elbow
1.00
1/4″ Male Check Valve
1.00
3/8″ B x 1/4″ F 90 Degree
1.00
1/4″ Male Close Nipple
1.00
1/4″ Male QD
1.00
Heater Element 600 Watt
1.00
Senor for Sniper Heater
1.00
Manual Sensor for Heater
1.00
Strain Relief for Tube Heater
1.00
Box for Tubular Heater
1.00
Heater Body Tubular
1.00
Pipe Wrap Insulation for Heater
1.00
3-Gallon Spotter Handle – Black
1.00
5/16″ x 1″ Spotter Wheel Bolt
2.00
Roller Blade Wheel for Spotter
2.00
Exhaust Grate for Sniper
2.00
Screw for Sniper Hatch
2.00
Motor Screw
2.00
10-32 x 3/8″ Screw
2.00
Motor Mount Plate for Spotter
1.00
3 Gallon Spotter Motor
1.00
Stamped Motor Screen
1.00
Spotter Motor Gasket
1.00
Strain Relief Nut
1.00
Black Wire
3-Gallon Spot Extractor Series (13)
10.0 Machine Schematic Drawing – with Heat
(12) 3-Gallon Spot Extractor Series
1.0 Safety Instructions
WARNING: PLEASE READ AND SAVE! FOLLOW THESE PRECAUTIONS WHEN USING YOUR SPOT
EXTRACTOR. · DO NOT operate this unit if any part of the unit appears to be
damaged. · DO NOT operate if ground plug is broken. · ELECTROCUTION RISK: DO
NOT operate if the unit is in standing water. · DO NOT use volatile substances
or operate where volatile substances exist. · DO NOT service while unit is
running or connected to electricity. Unplug the unit! · DO NOT use water hot
water in your unit. · DO NOT use solvents with this unit. · DO NOT use as a
dry vacuum. This will damage your motor. · DO NOT use unit unless completely
assembled. · Use only liquid detergents. Powders do not fully dissolve and
will damage the pump. · Always use defoamerin the recovery tank. Foam will
suspend moisture particles
that damage motor.
2.0 Setup / Prepare Unit for Use
DO NOT EXPOSE TO RAIN. STORE INDOORS. · All spot extractors no matter what
the time of year are shipped with antifreeze
in the pump and solution lines. Prior to first use, fill the tank with one
quart of water. Attach the hose and using the hand tool, flush out the system
by spraying the one quart of water through the pump. · Attach the 1-1/2-inch
vacuum hose and the brass quick disconnect. · Fill the base unit (the recovery
tank must be removed) with warm water (less than 100 degrees Fahrenheit). Fill
to approximately 4 inches from the top. Use a liquid detergent made for carpet
cleaning or upholstery. Read and mix to the dilution ratios as directed. · If
you use detergent/shampoo, you MUST clean your machine with 50/50 water/
vinegar solution after EVERY USE. · DO NOT use the heater without turning on
the pump. Running the heater without spraying for more than 5 mins will cause
the pump to overheat. Water/solution needs to run through the pump at all
times to keep the pump cool while in use. Failure to do so will void the
warranty. · Be sure to replace any filters back into the machine prior to use.
· Do not use citrus acid, buterol or harsh degreasers inside the machine.
Vacuum Shut-Off
The spot extractor is designed with a vacuum restrictor to reduce the vacuum
when the recovery tank is full. When the vacuum is restricted, the liquid will
not travel up the nozzle of the hand tool. The motor speeds up (the sound of
the motor will change) and this is your warning to dispose of recovered
solution. The restrictor is a foam float that slides up and down the vacuum
tube in the recovery tank.
3-Gallon Spot Extractor Series (5)
3.0 How to Use the 3-Gallon Spotter
· Remove 3-Gallon Spotter from its box.
· Place on level surface.
· Open rotating lock on back of machine and remove top tank (recovery tank)
from bottom tank (solution tank). Note: tip tank to allow it to come free from
the bottom of tank.
· Fill bottom tank with about a quart of water.
· Replace top tank by tipping front of tank to allow it to connect with bottom
tank. Center tank properly and then close rotating lock at back to secure in
place.
· Plug unit into a grounded electrical outlet.
· Attach Solution Hose to Unit: Hold female quick disconnect (female QD) on
hose and slide collar back on female QD. Slide on to male quick disconnect
(male QD) on machine. Release collar of female QD. You should hear hose click
into place. If you do not hear it click into place, repeat the previous steps.
· Secure vacuum hose securely onto drain spout on front of recovery tank. You
may have to force vacuum hose on by turning it back and forth while pushing
hose onto drain spout. If tool is not connected to hoses, repeat procedures to
attach tool to hoses.
· Turn on pump only and depress trigger on tool to flush the antifreeze
completely from unit.
· After flushing antifreeze from unit, remove top tank, fill bottom tank with
desired amount of clean water only (highly recommended), leaving water level
at least 4″ from top. Do not over fill.
· Tip solution tank into sink or drain if overfilled or to empty tank after
use.
· Pre-spray a small section of carpet with carpet cleaning solution. Agitate
with brush. Allow it to dwell a few minutes before extraction begins.
· For a heated unit, turn on heater for about 5 minutes to preheat water.
· For cold or heated spotters, turn on pump and depress trigger on tool to
begin spraying solution to carpet. Agitate carpet with end of tool. Then
alternate spraying solution and vacuuming. Alternating spraying and vacuuming
will allow heater to keep water at optimal temperature. CAUTION: brass QD’s
can get hot. Allow to cool before disconnecting.
· If you are not spraying solution for more than a few minutes, turn off
heater. Water should remain hot. When you begin to spray solution again, turn
heater back on.
· Listen for any changes to the vacuum motors. When recovery tank fills, the
yellow vacuum restrictor slides up pipe to partially block air. The sound of
the motor will be different and this is notice to shut off machine completely
and empty recovery tank. Failure to stop at this point will void warranty, as
water will be sucked into vacuum motors.
· Remove top tank from unit, open hatch on top by unscrewing counter clockwise
to allow air in and tip and pour recovered solution into a sink, toilet or
drain.
· Close top hatch by screwing it on clockwise, fill bottom tank if necessary,
reattach top tank to unit and continue cleaning.
(6) 3-Gallon Spot Extractor Series
9.0 Hoses and Hand Tool Drawing and Parts List
10-0505 4″ Stainless Steel Hand Tool with Clear View Head for Machines with No
Heat
Parts List
Drawing No. 1
2 3 4 5 6 7 8 9 10 11
Item No. 10-0505
10-0463 50-1007 10-0474 10-0475 10-0388 10-0402 10-0403 10-0506 10-0504
10-0502
Item Description
4″ Stainless Steel Hand Tool with Clear View Head Black Slip Hose Cuff for
Spotter 7-Foot Black Hose for Spotter 1/8″ Female QD for Spotter
Solution Hose for Spotter Velcro Strap 1/8″ Male QD for Stainless Steel Hand
Tool 1/8″ Brass Female Coupler Valve Clamp for Stainless Steel Hand Tool Valve
for Stainless Steel Hand Tool Jet for Stainless Steel Hand Tool
Qty. Needed
1.00 2.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
3-Gallon Spot Extractor Series (11)
8.0 Machine Parts List – No Heat
Drawing No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
22 23 24
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
43 44 45
Item ID
SP-3-ST-BLKGRAN SP-3-R-BLKGRAN 10-0383 10-0400-D 10-0412 10-0414 10-0384
10-0385 10-0074 10-0216 10-0379 10-0405 10-0302-A 10-0416-A 10-0304 10-0419
SP-3-H-BLK 10-0406 80-0017-2 10-0403 10-0402
10-0434 10-0407 10-0845-2
10-0300 10-0301 10-0435 10-0303 10-0387 10-0022 10-0017 10-1028 10-0492
10-0014 10-0380 10-1024 10-0354 10-0386 10-1030 10-0027-A 10-1026 10-0027
10-0448 10-0025 10-0400-C
Item Description
Qty. Needed
3-Gallon Solution Tank – Black Granite
1.00
3-Gallon Recovery Tank – Black Granite
1.00
6-32 x 1/4″ Phil Pan Screw
6.00
Latch for Sniper
1.00
C-Channel for Spotter Handle
2.00
Rivet for Spotter Handle
4.00
.125 Thick Nylon Washer
4.00
.06 Thick Nylon Washer
4.00
Flat Washer #8 SAE
5.00
Allen Head Screw for Backpack
4.00
8-32 x 3/8″ Screw
4.00
1-1/2″ PVC SCH40 Slip Thread
1.00
Hatch Cover Gasket for Spotter
1.00
1-1/2″ Black ABS Stand Pipe
0.60
Spotter Cap and Float Assembly
1.00
Screw for Spotter Hatch
6.00
3-Gallon Spotter Handle – Black
1.00
Nylon Barb 90 1/8″ NPT 1/4″
2.00
Bulk Head fitting for Spotter
1.00
1/8″ Brass Female Coupler
1.00
1/8″ Male QD
1.00
Threaded Hose for Spotter
2.50
1/8″ Strait Nylon Barb NPT
4.00
1/8″ Strainer for Spotter
1.00
55 PSI Pump for Spotter
1.00
L Bracket for Spotter
1.00
Oetiker Clamp
4.00
Roller Blade Wheel for Spotter
2.00
5/16″ x 1″ Spotter Wheel Bolt
2.00
Shoulder and Waist Belt Screw
1.00
Deflector Screw
1.00
Bottom Base Plate for Spotter
1.00
Screw for Plates on Spotter
2.00
Motor Screw
2.00
10-32 x 3/8″ Screw
2.00
Motor Mount Plate for Spotter
1.00
3-Gallon Spotter Motor
1.00
Stamped Motor Screen
1.00
Spotter Motor Gasket
1.00
Strain Relief Nut
1.00
Switch Plate for 3-Gallon w/ Heat
1.00
Pigtail Strain Relief
1.00
20-Foot Spotter Cord
1.00
On/Off Switch
2.00
Keeper Latch for Spotter
1.00
4.0 Preventative Instructions for Heater Use
Before Initial Use · Drain antifreeze from the machine system. · Ensure secure
outlet connection with no loose parts. · Confirm correct pigtail attachment. ·
Use only Sandia-approved extensions to prevent malfunctions. · For long-term
storage, use antifreeze every two months, especially in hot areas to
prevent scale buildup. · In cold climates, use antifreeze and store the unit
in a location above 65°F to
prevent heater damage.
During Heater Use · Activate both pump and heater buttons simultaneously. ·
Allow 5 minutes for water to heat with pump running before use. · Alternate
between 5-minute vacuuming and 5-minute hot water use intervals. · Allow at
least 2 minutes for hot water to flow from the unit. · DO NOT pour hot water
into the solution tank.
After Heater Use · Rinse the machine system with a 50/50 vinegar-water
solution (2 gallons for
spotters), then flush with water to maintain pump and system condition.
(10) 3-Gallon Spot Extractor Series
3-Gallon Spot Extractor Series (7)
5.0 Maintenance
Following Each Use
Remove the vacuum hose from the upper body. Un-clip and rotate the latch on
the back of the unit and remove the upper section of the spotter. Dispose of
the used solution by pouring the solution out of the vacuum inlet (not the
hatch cover) into the toilet or janitor’s closet sink. IMPORTANT! Be sure to
thoroughly drain water out of heater lines prior to storage in colder
climates. This heater will freeze and possibly crack, voiding your warranty. ·
For long-term storage, use antifreeze every two months, especially in hot
areas to prevent
scale buildup. · In cold climates, use antifreeze and store the unit in a
location above 65°F to prevent heater
damage.
Prevent Mineral Deposit Buildup
Vinegar may be used to prevent mineral deposit buildup in your machine’s lines
and pump. Failure to do so may clog your lines and pump. Every two weeks, pour
vinegar into the solution tank (dilute with 1/2 water). Run the pump, while
squeezing your wand or upholstery tool’s trigger until you smell vinegar or
notice it coming out of the tool. Let the machine sit overnight, and no
longer, with the vinegar in its lines. The next day, flush the machine with 1
gallon of clean water or until you do not smell vinegar any longer. We advise
you to do this every day, if you use your machine daily. PLEASE NOTE: If you
choose to use CLR, follow the directions on the bottle. DO NOT leave CLR in
the machine’s lines. Be sure to flush thoroughly. CLR may corrode the
machine’s components and VOID your warranty. If you choose to use vinegar, you
MUST dilute with 1/2 water. Failure to do so may damage the machine’s
components and VOID your warranty.
6.0 Grounding Instructions
DANGER: IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK OF
ELECTRIC SHOCK! This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by providing an
escape wire with an appropriate grounding plug. The plug must be plugged into
an outlet that is installed properly and grounded in accordance with all local
codes and ordinances.
Check with a qualified electrician or serviceman if the grounding instructions
are not completely understood, or if in doubt as to whether the product is
grounded properly. DO NOT modify the plug provided. If it will not fit into
the outlet, have a proper outlet installed by a qualified electrician.
This electric equipment is for use on a normal 120 volt circuit. It has a
grounded plug that looks like the plug illustrated in (Fig A). The use of a
temporary adaptor is NOT recommended.
NOTE: In Canada, the use of a temporary adapter is not permitted by the
Canadian Electrical Code.
· Ensure secure outlet connection with no loose parts.
· Confirm correct pigtail attachment.
· Use only Sandia-approved extensions to prevent malfunctions.
(8) 3-Gallon Spot Extractor Series