CleanFreak 3-Gallon Spot Extractor Instruction Manual

September 12, 2024
CleanFreak

3-Gallon Spot Extractor

“`html

Specifications:

  • Lifetime warranty on body
  • 2 years warranty on vacuum motors and pump
  • 1 year warranty on heater and all electrical parts
  • 90 days warranty on tools and accessories
  • 3-Gallon Capacity
  • Manufactured in the U.S.A.

Product Usage Instructions:

Warranty Information:

The product comes with a comprehensive warranty covering
different components for varying periods. It is important to adhere
to the warranty terms to ensure coverage in case of any issues.

Machine Registration:

Make sure to complete and return the Machine Registration Card
immediately after purchase to establish the warranty start date.
Proof of purchase is required for warranty validation.

Safety Instructions:

Before using the product, carefully read the Safety, Operation,
and Maintenance Manual provided. Ensure you understand all safety
precautions to prevent accidents.

Product Maintenance:

Regular maintenance of the machine is essential for optimal
performance and longevity. Refer to the Parts List for guidance on
replacement parts and maintenance procedures.

Usage Guidelines:

Follow the recommended guidelines for operating the 3-Gallon
Spot Extractor Series. Avoid misuse or abuse of the machine to
prevent voiding the warranty on motors and associated
components.

FAQ:

What does the warranty cover?

The warranty covers lifetime protection on the body, 2 years on
vacuum motors and pump, 1 year on heater and electrical parts, and
90 days on tools and accessories.

Where can I get labor services under warranty?

Labor services are provided only by a CleanFreak Repair Center.
If one is not nearby, it is the purchaser’s responsibility to
transport the machine to a designated repair center.

“`

New Equipment Warranty
Limited Warranty
CleanFreak warrants new equipment against defects in material and workmanship under normal use and service to the original purchaser. Any statutory implied warranties, including any warranty of merchantability or fitness for a particular purpose, are expressly limited to the duration of this written warranty. CleanFreak will not be liable for any other damages, including but not limited to indirect or special consequential damages arising out of or in connection with the furnishing, performance, use or inability to use the machine. This remedy shall be the exclusive remedy of the purchaser. The warranty period is subject to the conditions stated below.
Lifetime Warranty on Body, 2 Years on Vacuum Motors and Pump, 1 Year on Heater and on all Electrical Parts, 90 Days on Tools and Accessories
CleanFreak warrants the roto-molded body to be free from defects in material and workmanship, under normal use and service for a lifetime. CleanFreak warrants the motors and pump to be free from defects in material and workmanship, under normal use and proper maintenance service for two (2) years from the original date of sale, heater for one (1) year and all electrical parts one (1) year. Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period. Service labor charges are covered for one (1) year from the date of purchase, when performed by a CleanFreak Repair Center.
Labor is only provided by a CleanFreak Repair Center. If a CleanFreak Repair Center is not near you, it is the purchaser’s responsibility to take their machine to a CleanFreak Repair Center.
Normal wear items, such as capacitors, cords, finishes or switches, will be warranted for manufacturing defects for ninety (90) days from the purchase date.
All warranties of motors and associated components will be voided: if the machine is serviced by anyone other than a CleanFreak Repair Center; if the machine is mechanically modified; if the machine is operated when not operating properly; or if the machine is misused or abused.
The warranty starts on the purchase date by the original purchaser from CleanFreak subject to proof of purchase. The Machine Registration Card must be completed and returned immediately at the time of purchase. If proof of purchase cannot be identified, the warranty start date is ninety (90) days after the inventory stocking date at the distributor’s warehouse.
5109 N National Dr, Knoxville, TN 37914 Toll Free: 888-722-5508 | Local: 920-882-8453
www.CleanFreak.com
Make a copy of this card for future reference.
© All Rights Reserved

Safety, Operation and Maintenance Manual with Parts List
Please read before use!
3-Gallon Capacity

Important Information and Safety Instructions
Serial No: _____

Manufactured with Pride in the U.S.A.

© All Rights Reserved

3-Gallon Spot Extractor Series

Notes:
Dear Valued Client,
Congratulations on the purchase of your 3-Gallon Spot Extractor carpet and upholstery machine! The world of carpet cleaning is becoming more high-tech and competitive and we strive to provide you with the most innovative products. Our spot extractor with heat is yet another example of this, bringing a new dimension to carpet and upholstery cleaning with its cutting- edge features, quality and value. Please review this manual, paying careful attention to the Safety Instructions section. Keep in mind that any unnecessary damage, neglect or abuse of this machine will void your warranty. You can be confident that simple maintenance will ensure that your spot extractor with heat provides quality performance for many years to come. If warranty questions arise, please consult your manual or contact your CleanFreak representative Should you have any questions regarding maintenance, replacing parts or ordering parts, please call your CleanFreak representative. Before you begin using your Spot Extractor, please thoroughly review the Owner’s Manual. Again, congratulations on the purchase of your 3-Gallon Spot Extractor carpet and upholstery machine!
Questions or Comments?
Phone: 920-882-8453 Toll Free: 888-722-5508 Fax: 920-380-0878 Mailing Address: 5109 N National Dr, Knoxville, TN 37914 Visit our Web site at www.CleanFreak.com
(2) 3-Gallon Spot Extractor Series

11.0 Machine Parts List Continued – with Heat

Drawing No.
65
66
67 68 69 70 71

Item ID
10-0027
10-0448
10-0025 10-1026 10-0400-C 80-0022-A 10-0204

Item Description
Pigtail Strain Relief
20-Foot Spotter/Air Mover Cord
On/Off Switch Switch Plate for 3-Gallon w/ Heat Keeper Latch for Sniper Screw for 500 PSI Panel Motor Mount Back-Up Washer

Qty. Needed
1.00
1.00
3.00 1.00 1.00 2.00 2.00

12.0 Hoses and Hand Tool Drawing and Parts List
10-0501 Stainless Steel Hand Tool for Machines with Heat

Parts List
Drawing No. 1 2 3 4 5 6 7 8 9 10 11

Item No.
10-0501 10-0463 50-1008 10-0868
80-8007 10-0388 10-0870
10-0507 10-0506 10-0504 10-0502

(14) 3-Gallon Spot Extractor Series

Item Description
4″ Stainless Steel Upholstery Tool Black Slip Hose Cuff for Spotter 15-Foot Black Hose 1-1/4″ 1/4″ Female QD for Spotter
1/4″ x 15-Foot Extractor Hose Velcro Strap 1/4″ Male QD
8″ Black Hose for Stainless Steel Hand Tool Valve Clamp for Stainless Steel Hand Tool Valve for Stainless Steel Hand Tool Jet for Stainless Steel Hand Tool

Qty. Needed
1.00 2.00 1.00 1.00
1.00 1.00 1.00
1.00 1.00 1.00 1.00

New Equipment Warranty
Lifetime on body, 2 years on vacuum motors and pump, 1 year on heater and on all electrical components, 90 days on tools and accessories.
Warranty Policy
All equipment is inspected and tested before shipping from the manufacturer. All parts are warranted to be new and free from defects in workmanship and material, under normal use to the original retail purchaser. This warranty limits manufacturer’s liability for defects in workmanship or materials for replacement of defective parts only. Manufacturer accepts no liability for incidental or consequential damages arisen from the use of any equipment, defective or not. This warranty is in lieu of all expressed or implied warranties and is extended only to the original retail purchaser. Manufacturer sales and service representatives are not authorized to waive or alter the terms of this warranty, or to increase the obligations of the manufacturer under the warranty. Parts replaced or repaired under warranty are warranted for the remainder of the original warranty period.
Freight charges shall be covered for ninety (90) days from the original purchase date. After this ninety (90) day period, freight charges shall be paid by the equipment owner, subject to manufacturer discretion. Certain circumstances may require additional consideration.
Manufacturer covers up to 1-year (365 days) of service labor at manufacturer’s calculated hourly labor rate/repair time when performed by a manufacturer’s authorized-service provider. Ultimately, labor reimbursement costs are at the discretion of the manufacturer. After 1-year, the original retail purchaser is responsible for all labor costs with no manufacturer reimbursement.
Manufacturer charges a 15% restocking fee for any items that are being returned to stock. Items must be new, unused and free of damage. Only good for up to 1-year (365 days). After 1-year, manufacturer does not accept the return of any item(s) for a reimbursed price. Authorized warranty replacement parts need to come directly from the manufacturer. Use of any other parts will void warranty. Manufacturer does not reimburse for parts used by the customer that were not supplied directly for the machine under warranty.
Returned Material Authorization (RMA) Procedure
Original purchaser (distributor/service center) must contact the manufacturer to follow correct RMA/warranty procedures. Must include a copy of RMA Sheet enclosed in the box with returned item. No returns shall be authorized unless proper RMA procedures are followed. It is the responsibility of the distributor to repair the customer’s equipment as soon as possible. If the distributor does not have the facilities to repair the equipment, it may be shipped or taken to an authorized service center for repair.
Customer must contact the distributor prior to working on or changing out any parts, etc. Manufacturer must issue an RMA Sheet containing approved labor time and replacement parts. Do not send parts or equipment back to manufacturer without an RMA number and approval. No labor will be paid for, nor part costs paid for or reimbursed that have not been previously approved by the manufacturer. All warranty work must be approved and authorized to qualify and appropriate warranty procedures must be followed.
3-Gallon Spot Extractor Series (3)

Table of Contents
New Equipment Warranty……………………………………………………………………………………………………….3 Returned Material Authorization (RMA) Procedure…………………………………………………………….3 1.0 Safety Instructions …………………………………………………………………………………………………………….5 2.0 Set-Up/Prepare Unit for Use…………………………………………………………………………………………….5 3.0 How to Use 3-Gallon Spotter ………………………………………………………………………………………….6 4.0 Preventative Instructions for Heater Use……………………………………………………………………….7 5.0 Maintenance ………………………………………………………………………………………………………………………8 6.0 Grounding Instructions…………………………………………………………………………………………………….8 7.0 Machine Schematic Drawing – No Heat …………………………………………………………………………9 8.0 Machine Parts List – No Heat ……………………………………………………………………………………….. 10 9.0 Hoses and Hand Tool Drawing and Parts List (Clear)………………………………………………… 11 10.0 Machine Schematic Drawing – Heat………………………………………………………………………….. 12 11.0 Machine Parts List – Heat………………………………………………………………………………………..13-14 12.0 Hoses and Hand Tool Drawing and Parts List (Stainless Steel)……………………………… 14
(4) 3-Gallon Spot Extractor Series

11.0 Machine Parts List – with Heat

Drawing No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
45 46 47 48 49 50 51 52 53 54 55 56 57 58 59
60 61 63 64 65

Item ID
SP-3-ST-BLKGRAN SP-3-RT-GRNGRAN 10-0383 10-0400-D 10-0412 10-0414 10-0384 10-0385 10-0074 10-0216 10-0379 10-0405 10-0302-A 10-0416-A 10-0304 10-0419 SP-3-HS-BLKGRAN 10-0831 10-0832 10-0300 10-0403-M 10-0901 10-0510 80-0017 80-0024-B 10-0826 10-0843 10-0434 10-0407 10-0845-2 10-0301 10-0828 10-0022 10-0017 T-C-011 T-WPUR 80-0011-2 80-0010 10-0843 10-0852 80-0101-M 80-0014 10-0479 10-0870
10-1500-B 10-0814 10-0814-B 10-0907 10-0906 10-0900 10-0801-G SP-3-H-BLK 10-0387 10-0303 10-0822 10-0419-A 10-0014 10-0380 10-1024
10-0354 10-0386 10-1030 10-0027-A T-WBLA

Item Description

Qty. Needed

3-Gallon Solution Tank – Black Granite

1.00

3-Gallon Recovery Tank – Green Granite

1.00

6-32 x 1/4″ Phil Pan Screw

6.00

Latch for Sniper

1.00

C-Channel for Spotter Handle

2.00

Rivet for Spotter Handle

4.00

.125 Thick Nylon Washer

4.00

.06 Thick Nylon Washer

4.00

Flat Washer #8 SAE

11.00

Allen Head Screw for Backpack

4.00

8-32 x 3/8″ Screw

4.00

1-1/2″ PVC SCH40 Slip Thread

1.00

Hatch Cover Gasket for Spotter

1.00

1-1/2″ Black ABS Stand Pipe

1.00

Spotter Cap and Float Assembly

1.00

Screw for Spotter Hatch

6.00

3-Gallon Heater Skirt – Black Granite

1.00

S/R Bracket for Sniper

1.00

S/R Strap Bolts

2.00

55 PSI Pump for Spotter

1.00

1/8″ Brass Male Nipple

1.00

175 PSI Relief Valve for Heater

1.00

1/8″ Brass Plug

1.00

Bulk Head fitting for Sniper

2.00

1/4″ MPT x 3/8″ Barb

4.00

3/4″ Hose Clamp for Sniper

6.00

3/8″ Black Hose for Sniper

1.00

Threaded Hose for Spotter

1.00

1/8″ Strait Nylon Barb NPT

2.00

1/8″ Strainer for Spotter

1.00

L Bracket for Spotter

1.00

90 Degree Brass Fitting for Sniper

1.00

Shoulder and Waist Belt Screw

3.00

Deflector Screw

1.00

Female Terminal Connector

10.00

Purple Wire

90 Degree Street Elbow

1.00

1/4″ Brass Tee

1.00

3/8″ Black Hose for Sniper

1.00

1/4″ 90 Degree Brass Elbow

1.00

1/4″ Male Check Valve

1.00

3/8″ B x 1/4″ F 90 Degree

1.00

1/4″ Male Close Nipple

1.00

1/4″ Male QD

1.00

Heater Element 600 Watt

1.00

Senor for Sniper Heater

1.00

Manual Sensor for Heater

1.00

Strain Relief for Tube Heater

1.00

Box for Tubular Heater

1.00

Heater Body Tubular

1.00

Pipe Wrap Insulation for Heater

1.00

3-Gallon Spotter Handle – Black

1.00

5/16″ x 1″ Spotter Wheel Bolt

2.00

Roller Blade Wheel for Spotter

2.00

Exhaust Grate for Sniper

2.00

Screw for Sniper Hatch

2.00

Motor Screw

2.00

10-32 x 3/8″ Screw

2.00

Motor Mount Plate for Spotter

1.00

3 Gallon Spotter Motor

1.00

Stamped Motor Screen

1.00

Spotter Motor Gasket

1.00

Strain Relief Nut

1.00

Black Wire

3-Gallon Spot Extractor Series (13)

10.0 Machine Schematic Drawing – with Heat
(12) 3-Gallon Spot Extractor Series

1.0 Safety Instructions
WARNING: PLEASE READ AND SAVE! FOLLOW THESE PRECAUTIONS WHEN USING YOUR SPOT EXTRACTOR. · DO NOT operate this unit if any part of the unit appears to be damaged. · DO NOT operate if ground plug is broken. · ELECTROCUTION RISK: DO NOT operate if the unit is in standing water. · DO NOT use volatile substances or operate where volatile substances exist. · DO NOT service while unit is running or connected to electricity. Unplug the unit! · DO NOT use water hot water in your unit. · DO NOT use solvents with this unit. · DO NOT use as a dry vacuum. This will damage your motor. · DO NOT use unit unless completely assembled. · Use only liquid detergents. Powders do not fully dissolve and will damage the pump. · Always use defoamerin the recovery tank. Foam will suspend moisture particles
that damage motor.
2.0 Setup / Prepare Unit for Use
DO NOT EXPOSE TO RAIN. STORE INDOORS. · All spot extractors ­ no matter what the time of year ­ are shipped with antifreeze
in the pump and solution lines. Prior to first use, fill the tank with one quart of water. Attach the hose and using the hand tool, flush out the system by spraying the one quart of water through the pump. · Attach the 1-1/2-inch vacuum hose and the brass quick disconnect. · Fill the base unit (the recovery tank must be removed) with warm water (less than 100 degrees Fahrenheit). Fill to approximately 4 inches from the top. Use a liquid detergent made for carpet cleaning or upholstery. Read and mix to the dilution ratios as directed. · If you use detergent/shampoo, you MUST clean your machine with 50/50 water/ vinegar solution after EVERY USE. · DO NOT use the heater without turning on the pump. Running the heater without spraying for more than 5 mins will cause the pump to overheat. Water/solution needs to run through the pump at all times to keep the pump cool while in use. Failure to do so will void the warranty. · Be sure to replace any filters back into the machine prior to use. · Do not use citrus acid, buterol or harsh degreasers inside the machine.
Vacuum Shut-Off
The spot extractor is designed with a vacuum restrictor to reduce the vacuum when the recovery tank is full. When the vacuum is restricted, the liquid will not travel up the nozzle of the hand tool. The motor speeds up (the sound of the motor will change) and this is your warning to dispose of recovered solution. The restrictor is a foam float that slides up and down the vacuum tube in the recovery tank.
3-Gallon Spot Extractor Series (5)

3.0 How to Use the 3-Gallon Spotter
· Remove 3-Gallon Spotter from its box.
· Place on level surface.
· Open rotating lock on back of machine and remove top tank (recovery tank) from bottom tank (solution tank). Note: tip tank to allow it to come free from the bottom of tank.
· Fill bottom tank with about a quart of water.
· Replace top tank by tipping front of tank to allow it to connect with bottom tank. Center tank properly and then close rotating lock at back to secure in place.
· Plug unit into a grounded electrical outlet.
· Attach Solution Hose to Unit: Hold female quick disconnect (female QD) on hose and slide collar back on female QD. Slide on to male quick disconnect (male QD) on machine. Release collar of female QD. You should hear hose click into place. If you do not hear it click into place, repeat the previous steps.
· Secure vacuum hose securely onto drain spout on front of recovery tank. You may have to force vacuum hose on by turning it back and forth while pushing hose onto drain spout. If tool is not connected to hoses, repeat procedures to attach tool to hoses.
· Turn on pump only and depress trigger on tool to flush the antifreeze completely from unit.
· After flushing antifreeze from unit, remove top tank, fill bottom tank with desired amount of clean water only (highly recommended), leaving water level at least 4″ from top. Do not over fill.
· Tip solution tank into sink or drain if overfilled or to empty tank after use.
· Pre-spray a small section of carpet with carpet cleaning solution. Agitate with brush. Allow it to dwell a few minutes before extraction begins.
· For a heated unit, turn on heater for about 5 minutes to preheat water.
· For cold or heated spotters, turn on pump and depress trigger on tool to begin spraying solution to carpet. Agitate carpet with end of tool. Then alternate spraying solution and vacuuming. Alternating spraying and vacuuming will allow heater to keep water at optimal temperature. CAUTION: brass QD’s can get hot. Allow to cool before disconnecting.
· If you are not spraying solution for more than a few minutes, turn off heater. Water should remain hot. When you begin to spray solution again, turn heater back on.
· Listen for any changes to the vacuum motors. When recovery tank fills, the yellow vacuum restrictor slides up pipe to partially block air. The sound of the motor will be different and this is notice to shut off machine completely and empty recovery tank. Failure to stop at this point will void warranty, as water will be sucked into vacuum motors.
· Remove top tank from unit, open hatch on top by unscrewing counter clockwise to allow air in and tip and pour recovered solution into a sink, toilet or drain.
· Close top hatch by screwing it on clockwise, fill bottom tank if necessary, reattach top tank to unit and continue cleaning.
(6) 3-Gallon Spot Extractor Series

9.0 Hoses and Hand Tool Drawing and Parts List
10-0505 4″ Stainless Steel Hand Tool with Clear View Head for Machines with No Heat

Parts List
Drawing No. 1
2 3 4 5 6 7 8 9 10 11

Item No. 10-0505
10-0463 50-1007 10-0474 10-0475 10-0388 10-0402 10-0403 10-0506 10-0504 10-0502

Item Description
4″ Stainless Steel Hand Tool with Clear View Head Black Slip Hose Cuff for Spotter 7-Foot Black Hose for Spotter 1/8″ Female QD for Spotter
Solution Hose for Spotter Velcro Strap 1/8″ Male QD for Stainless Steel Hand Tool 1/8″ Brass Female Coupler Valve Clamp for Stainless Steel Hand Tool Valve for Stainless Steel Hand Tool Jet for Stainless Steel Hand Tool

Qty. Needed
1.00 2.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00

3-Gallon Spot Extractor Series (11)

8.0 Machine Parts List – No Heat

Drawing No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
22 23 24
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
43 44 45

Item ID
SP-3-ST-BLKGRAN SP-3-R-BLKGRAN 10-0383 10-0400-D 10-0412 10-0414 10-0384 10-0385 10-0074 10-0216 10-0379 10-0405 10-0302-A 10-0416-A 10-0304 10-0419 SP-3-H-BLK 10-0406 80-0017-2 10-0403 10-0402
10-0434 10-0407 10-0845-2
10-0300 10-0301 10-0435 10-0303 10-0387 10-0022 10-0017 10-1028 10-0492 10-0014 10-0380 10-1024 10-0354 10-0386 10-1030 10-0027-A 10-1026 10-0027
10-0448 10-0025 10-0400-C

Item Description

Qty. Needed

3-Gallon Solution Tank – Black Granite

1.00

3-Gallon Recovery Tank – Black Granite

1.00

6-32 x 1/4″ Phil Pan Screw

6.00

Latch for Sniper

1.00

C-Channel for Spotter Handle

2.00

Rivet for Spotter Handle

4.00

.125 Thick Nylon Washer

4.00

.06 Thick Nylon Washer

4.00

Flat Washer #8 SAE

5.00

Allen Head Screw for Backpack

4.00

8-32 x 3/8″ Screw

4.00

1-1/2″ PVC SCH40 Slip Thread

1.00

Hatch Cover Gasket for Spotter

1.00

1-1/2″ Black ABS Stand Pipe

0.60

Spotter Cap and Float Assembly

1.00

Screw for Spotter Hatch

6.00

3-Gallon Spotter Handle – Black

1.00

Nylon Barb 90 1/8″ NPT 1/4″

2.00

Bulk Head fitting for Spotter

1.00

1/8″ Brass Female Coupler

1.00

1/8″ Male QD

1.00

Threaded Hose for Spotter

2.50

1/8″ Strait Nylon Barb NPT

4.00

1/8″ Strainer for Spotter

1.00

55 PSI Pump for Spotter

1.00

L Bracket for Spotter

1.00

Oetiker Clamp

4.00

Roller Blade Wheel for Spotter

2.00

5/16″ x 1″ Spotter Wheel Bolt

2.00

Shoulder and Waist Belt Screw

1.00

Deflector Screw

1.00

Bottom Base Plate for Spotter

1.00

Screw for Plates on Spotter

2.00

Motor Screw

2.00

10-32 x 3/8″ Screw

2.00

Motor Mount Plate for Spotter

1.00

3-Gallon Spotter Motor

1.00

Stamped Motor Screen

1.00

Spotter Motor Gasket

1.00

Strain Relief Nut

1.00

Switch Plate for 3-Gallon w/ Heat

1.00

Pigtail Strain Relief

1.00

20-Foot Spotter Cord

1.00

On/Off Switch

2.00

Keeper Latch for Spotter

1.00

4.0 Preventative Instructions for Heater Use
Before Initial Use · Drain antifreeze from the machine system. · Ensure secure outlet connection with no loose parts. · Confirm correct pigtail attachment. · Use only Sandia-approved extensions to prevent malfunctions. · For long-term storage, use antifreeze every two months, especially in hot areas to
prevent scale buildup. · In cold climates, use antifreeze and store the unit in a location above 65°F to
prevent heater damage.
During Heater Use · Activate both pump and heater buttons simultaneously. · Allow 5 minutes for water to heat with pump running before use. · Alternate between 5-minute vacuuming and 5-minute hot water use intervals. · Allow at least 2 minutes for hot water to flow from the unit. · DO NOT pour hot water into the solution tank.
After Heater Use · Rinse the machine system with a 50/50 vinegar-water solution (2 gallons for
spotters), then flush with water to maintain pump and system condition.

(10) 3-Gallon Spot Extractor Series

3-Gallon Spot Extractor Series (7)

5.0 Maintenance
Following Each Use
Remove the vacuum hose from the upper body. Un-clip and rotate the latch on the back of the unit and remove the upper section of the spotter. Dispose of the used solution by pouring the solution out of the vacuum inlet (not the hatch cover) into the toilet or janitor’s closet sink. IMPORTANT! Be sure to thoroughly drain water out of heater lines prior to storage in colder climates. This heater will freeze and possibly crack, voiding your warranty. · For long-term storage, use antifreeze every two months, especially in hot areas to prevent
scale buildup. · In cold climates, use antifreeze and store the unit in a location above 65°F to prevent heater
damage.
Prevent Mineral Deposit Buildup
Vinegar may be used to prevent mineral deposit buildup in your machine’s lines and pump. Failure to do so may clog your lines and pump. Every two weeks, pour vinegar into the solution tank (dilute with 1/2 water). Run the pump, while squeezing your wand or upholstery tool’s trigger until you smell vinegar or notice it coming out of the tool. Let the machine sit overnight, and no longer, with the vinegar in its lines. The next day, flush the machine with 1 gallon of clean water or until you do not smell vinegar any longer. We advise you to do this every day, if you use your machine daily. PLEASE NOTE: If you choose to use CLR, follow the directions on the bottle. DO NOT leave CLR in the machine’s lines. Be sure to flush thoroughly. CLR may corrode the machine’s components and VOID your warranty. If you choose to use vinegar, you MUST dilute with 1/2 water. Failure to do so may damage the machine’s components and VOID your warranty.
6.0 Grounding Instructions
DANGER: IMPROPER INSTALLATION OF THE GROUNDING PLUG CAN RESULT IN A RISK OF ELECTRIC SHOCK! This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire with an appropriate grounding plug. The plug must be plugged into an outlet that is installed properly and grounded in accordance with all local codes and ordinances.
Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the product is grounded properly. DO NOT modify the plug provided. If it will not fit into the outlet, have a proper outlet installed by a qualified electrician.
This electric equipment is for use on a normal 120 volt circuit. It has a grounded plug that looks like the plug illustrated in (Fig A). The use of a temporary adaptor is NOT recommended.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electrical Code.
· Ensure secure outlet connection with no loose parts.
· Confirm correct pigtail attachment.
· Use only Sandia-approved extensions to prevent malfunctions.
(8) 3-Gallon Spot Extractor Series

7.0 Machine Schematic Drawing – No Heat
3-Gallon Spot Extractor Series (9)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals