waveform lighting CENTRIC PRO Series Flicker Free Dimmable Power Supply Installation Guide

September 9, 2024
Waveform Lighting

CENTRIC PRO Series Flicker Free Dimmable Power Supply

“`html

Product Information

Specifications:

  • Model: CENTRIC PRO SERIES
  • Part Number: 3902
  • Manufacturer: Waveform Lighting
  • Location: Vancouver, WA, USA

Product Usage Instructions

Junction Box Mounting:

Use appropriate-sized screws to mount the integrated junction
box using the mounting holes and tabs located along the product
ends. Ensure the mounting location meets electrical code
ventilation. If required, the product can also be mounted
horizontally using the mounting holes and tabs located along the
short edge of the product ends.

Power Supply Positioning:

For best LED strip performance, position the power supply unit
as close to the LED strip as possible.

Junction Box Configuration:

Remove the small screws to release the front-side wires and
compartment. Place the wires in an organized manner within the
junction box for efficient configuration.

Wire Routing and Configuration:

1. Remove the circular knockouts on both the input and output
ends.

2. Install wire reliefs, ensuring appropriate wire gauge and
code-compliant components are selected.

3. Route the wires from LED strip light through the strain
relief and knockout, connecting them to corresponding output wires
using code-compliant wire connectors.

4. If using 0-10V or 1-10V dimming, feed the dimming circuit
wires through the strain relief and knockout, connecting them to
the dimming signal input wires using code-compliant wire
connectors.

5. For installations using phase-dimming (e.g., TRIAC), skip the
dimming signal input step and proceed to connect line voltage wires
through the strain relief and knockout to corresponding input wires
using code-compliant wire connectors.

FAQ

Q: Can I perform the installation without prior knowledge of

lighting systems?

A: No, installation should only be performed by qualified
individuals with knowledge of lighting systems operation and
installation. Seek a qualified electrician’s assistance if you are
not comfortable with electrical work.

Q: What is the recommended positioning for the power supply

unit?

A: For best LED strip performance, position the power supply
unit as close to the LED strip as possible.

“`

CENTRIC PRO SERIESTM Installation Instructions

PN: 3902

ALWAYS OBSERVE ELECTRICAL SAFETY PRECAUTIONS. ENSURE POWER IS SHUT OFF PRIOR TO PERFORMING ELECTRICAL WORK. INSTALLATION SHOULD ONLY BE PERFORMED BY QUALIFIED INDIVIDUALS WITH KNOWLEDGE OF LIGHTING SYSTEMS OPERATION AND INSTALLATION. IF YOU ARE NOT QUALIFIED OR NOT COMFORTABLE, SEEK A QUALIFIED ELECTRICIAN’S ASSISTANCE.

JUNCTION BOX MOUNTING

+ +

+ +

+ +

Use appropriate-sized screws to mount the integrated junction box using the mounting holes and tabs located along the product ends. Ensure the mounting location meets electrical code
ventilation.

If required, the product can also be mounted horizontally, using the mounting holes and tabs located along the short edge of the product ends.
For best LED strip performance, the power supply unit should be positioned as close to the LED strip as possible.

Remove the small screws to release the front-side wires and compartment.

JUNCTION BOX CONFIGURATION

Rev 1.0 / 06-23-2024 © 2024 Waveform Lighting, LLC

place.
WIRE ROUTING AND CONFIGURATION

+ + +

+ +

Remove the circular knockouts on both the input and output ends.

Install wire reliefs, ensuring that the appropriate wire gauge and code- compliant components are selected.

Wires from LED Strip

Wires for 0-10V Dimming

Line Voltage Wires

Route the wires from the LED strip light through the strain relief and knockout, and connect them to the corresponding output wires using code- compliant wire connectors. Ensure that the polarity of the output wires is correct.

If utilizing 0-10V or 1-10V dimming, the dimming circuit wires also need to be fed through the strain relief and knockout. Connect these wires to the corresponding dimming signal input wires using code-compliant wire connectors.
Installations using phase-dimming (e.g. TRIAC) can skip this step and leave the dimming signal input

Finally, route the line voltage wires through the strain relief and knockout, and connect them to the corresponding input wires using code-compliant wire connectors. Ensure that the polarity of the output wires is correct.

WAVEFORM LIGHTING, L LC 4400 NE 77th Ave Ste 275 | Vancouver, WA 98662, USA

//ww w.wav

.com | sup port@wav

.com