GARDENA 3500-4 Automatic Home and Garden Pump Instruction Manual

September 9, 2024
Gardena

3500-4 Automatic Home and Garden Pump

“`html

Product Specifications:

  • Model: 3500/4 (Art. 1757)
  • Intended Use: Automatic Home & Garden Pump
  • Maximum Pressure: 4 bar
  • Model: 4000/5 (Art. 1758)
  • Maximum Pressure: 5 bar

Product Usage Instructions:

1. Safety Instructions:

It is crucial to read the operator’s manual carefully before
using the product. Keep it for future reference.

Symbols on the product:

  • Read operator’s manual.

General Safety Warnings – Electrical Safety:

DANGER! Electric shock! Risk of injury due to
electric current. The product must be supplied through a residual
current device (RCD) with a rated residual operating current not
exceeding 30 mA.

DANGER! Electric shock! Disconnect the product
from the mains before maintaining or replacing parts. The
disconnected socket must be in the visual range.

Dry-running Protection:

If no water is pumped (undercurrent), the pump switches off
automatically.

Anti-lock Protection:

If the motor blocks (overcurrent), the pump switches off
automatically.

Additional Safety Warnings – Electrical Safety:

DANGER! Cardiac arrest! The product generates
an electromagnetic field while operating, which may interfere with
medical implants. Consult a physician and the implant manufacturer
before using the product if you have medical implants.

DANGER! Electric shock! The product must not be
operated if there are people in the swimming pool or garden pond.
Ensure electrical connections are in areas that cannot be flooded
and protect the power plug from moisture.

Connecting Cable:

DANGER! Electric shock! Do not cut off the
mains plug to feed through a wall, as moisture can cause a short
circuit.

2. Intended Use:

The GARDENA Automatic Home & Garden Pump is designed for
private use in homes and hobby gardens. It should not be used for
operating irrigation equipment in public gardens. Suitable for
pumping rainwater, tap water, and chlorinated water. Not intended
for continuous operation in industrial applications or continuous
circulating operation.

3. Prohibited Liquids:

DANGER! Corrosive, easily combustible,
aggressive, or explosive liquids such as gasoline, petroleum,
nitrothinner, saltwater, and food intended for consumption must not
be pumped.

“`

Frequently Asked Questions (FAQ):

Q: Can children use this product unsupervised? A: The product
can be used by children aged 8 years and above if they have been
given proper supervision and instruction on safe usage. Q: What
kind of liquids should not be pumped using this product?
A:
Corrosive, easily combustible, aggressive, or explosive liquids
such as gasoline, petroleum, nitrothinner, saltwater, and food
intended for consumption must not be pumped. Q: Is the pump
suitable for continuous operation in industrial settings?
A: No,
the product is not intended for continuous operation in industrial
applications or continuous circulating operation.

3500/4

Art. 1757

en Operator’s manual Automatic Home & Garden Pump

4000/5

Art. 1758

GAR_01757-52.960.04_2024-06-27.indd 1

27.06.24 08:45

en
1. SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 5. STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 6. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 7. TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 8. ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 9. WARRANTY / SERVICE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Translation of the original instructions.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. (IEC 60335-1)
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (EN 60335-1)
Intended use: The GARDENA Automatic Home & Garden Pump is intended for private use in the home and hobby garden and is not intended to be used for operating irrigation equipment and systems in public gardens. It can be used for pumping rainwater, tap water and chlorinated water. The product is not intended for continuous operation (e. g. industrial applications, continuous circulating operation).
DANGER! v Corrosive, easily combustible, aggressive or explosive liquids
(such as gasoline, petroleum or nitrothinner), saltwater and food intended for consumption must not be pumped.
Pressure amplification: If you use the pump for pressure amplification, the maximum permissible internal pressure must not exceed 6 bar. Consequently, the maximum inlet pressure is: Model 1757 3500/4 ­ 2.0 bar Model 1758 4000/5 ­ 1.5 bar To ensure the correct inlet pressure, it is essential to use an adjustable pressure limiting valve.
1. SAFETY INSTRUCTIONS
IMPORTANT! Read the operator’s manual carefully before use and keep for future reference.
Symbols on the product:
Read operator’s manual.

General safety warnings Electrical safety
DANGER! Electric shock! Risk of injury due to electric current. v The product must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
DANGER! Electric shock! Risk of injury due to electric current. v Disconnect the product from the mains before you maintain or replace parts. Thereby the disconnected socket must be in the visual range.
Safe operating practices The water temperature should not exceed 35 °C. The pump must not be used when people are in the water. Leaking lubricants can contaminate the pumped liquid.
Circuit breakers Dry-running protection: If no water is pumped (undercurrent) the pump switches off automatically. Anti-lock protection: If the motor blocks (overcurrent), the pump switches off automatically.
Additional safety warnings Electrical safety
DANGER! Cardiac arrest! This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before you operate the product.
DANGER! Electric shock! The product must not be operated if there are people in the swimming pool or garden pond. v Make sure that the electrical plug and socket connections are fitted in
an area which cannot be flooded. v Protect the power plug from moisture.
Connecting cable
DANGER! Electric shock! With a cut off mains plug, moisture can get into electrical parts via the mains cable and cause a short circuit. v Do not cut the mains plug off (e. g. to feed through a wall).
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
According to DIN VDE (German Electrical Engineers’ Association) 0620, mains power cables and extension cables must not have a smaller cross-section than the rubber-sheathed cables of the designation H07RN-F. The cable length must be at least 10 m. Data indicated on the type plate must match technical data of the mains supply. Disconnect the product from the mains when it is not in use. Protect plug and power cable from heat, oil and sharp edges. Do not use the power cable to carry or to unplug the pump. As an additional safety device an approved safety switch can be used. v Please ask your electrician for his advice. Only use extension cables with earth connectors for operating this pump. A damaged pump must not be used. Before operating the pump look and see if there is any damage to the pump (especially to the power cable and plug). v In case of damage, please have the pump checked by our GARDENA
Service Centre.
Personal safety
DANGER! Risk of suffocation! Small parts can be easily swallowed. There is also a risk that the poly bag can suffocate toddlers. Keep toddlers away when you assemble the product.
DANGER! Risk of injury due to hot water! If the electronic control is defective or if the water supply on the intake side of the pump fails, any water remaining in the pump may heat up, generating a risk of injuries caused by hot water on leakage.

2
GAR_01757-52.960.04_2024-06-27.indd 2

27.06.24 08:45

v Disconnect the pump from the mains, let the water cool (approx. 10 ­ 15 min.) and secure the water supply on the intake side before putting into operation again.
Do not use the product while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while you operate the product may result in serious personal injury. When connecting the pump to the water supply system, the country-specific sanitary regulations must be observed to prevent water not of drinking water quality being drawn back in. When water flows through the pump it is no drinking water anymore. When using the product, cover hair and do not wear scarves and other loose items of clothing. Make sure that no children or unauthorised persons are within reach of the pump and the pumped medium without supervision. In order to avoid dry-running of the pump, take care that the end of the suction hose is always submerged into the water. v Before each operation, fill the pump with liquid to be pumped (approx. 2 to 3 l). The pump must be located on solid, even ground, protected from flooding. Take care that the pump cannot fall into water. Very fine sand can pass through the integrated filter (mesh size 0.45 mm) and cause accelerated wear in the hydraulic parts. v For sandy water, you should additionally use the GARDENA Pump
Preliminary Filter, art. 1730 (mesh size 0.1 mm). The temperature of the pumped liquid must be between 2 °C and 35 °C. Only stow the product in temperatures between 2 °C and 70 °C.
2. INSTALLATION
DANGER! Electric shock! Risk of injury due to electric current. v Disconnect the product from the mains before you install the product.
Installation location [ Fig. I1 ]:
The pump must be installed in a location with sufficient venti lation in the area of the ventilation slots. It must be at a distance of at least 5 cm from the walls. No dirt contamination (e. g. sand or soil) may be sucked in through the ventilation slots.
Set up the pump so that it is prevented from slipping and that an appropriately large collecting vessel for draining the pump or the system can be
placed under the drain screw 1.
Install the pump at a safe distance (min. 2 m) from the pumping medium. If possible, install the pump higher than the surface of the water to be pumped. If this is not possible, install a vacuum-resistant shut-off device between the pump and the suction hose to allow the integrated filter to be cleaned. If the system is permanently installed, appropriate shut-off devices must be installed on the input and output sides. Important for maintenance and cleaning work on the pump or for shutdown, for example.
Connections:
CAUTION! The GARDENA connection pieces on the intake and deli very sides may only be tightened by hand. Check whether the seal ring is present and undamaged before screwing the suction hose onto the suction inlet. When using metal connections, damage could occur on the connection thread due to inapprop riate assembly. Therefore, screw on the connection fittings with the upmost care. Use sealing tape only for sealing metallic connection fittings.
Suction side: Do not use modular water hose components on the suction side! A vacuum-tight suction hose must be used e.g.: ­ GARDENA Suction Hose Art. 1411 / 1418 ­ GARDENA Bore Hole Suction Hose Art. 1729 ­ GARDENA Suction Hose sold by the metre with
GARDENA Hose Clamp Art. 7192 / 7191. If very fine dirt is present, we recommend the use of a GARDENA Pump preliminary filter Art. 1730 / 1731 in addition to the integrated filter. To reduce the pump repriming time, we recommend to use a suction hose with backflow preventer, which prevents the suction hose emptying automatically when the Automatic Home & Garden Pump is switched off.

Important for fixed installation: For greater suction heads, use a suction hose with a small diameter (3/4″).
Pressure side: A pressure-resistant hose must be used on the pressure side, e. g.: ­ GARDENA Garden Hose (3/4″) Art. 18113 with
GARDENA Connection Set Art. 1752.
Important for fixed installation: If the product is permanently installed in an enclosed space, only flexible hoses (e.g. reinforced hoses) may be used for connecting the service water supply, rather than rigid piping. Flexible hoses will reduce the noise level and prevent damage caused by pressure surges. Install fixed pipes at an upward gradient on the first 2 m only. To avoid damage to the thread, ensure careful and accurate installation when using metal connections.
To connect the suction hose [ Fig. I2 ]:
1. Screw the suction hose fitting 3 onto the suction inlet 4 and tighten
it by hand.
2. Slide the suction hose 2 onto the suction hose fitting 3 and secure
it e.g. with a GARDENA Hose Clamp Art. 7192 / 7191. 3. For suction head exceeding 4 m secure the suction hose
(e. g. by fastening it to a wooden post). The pump and the suction hose are relieved from the weight of the water.
To connect the pressure hose [ Fig. I3 ]: The pressure hose can be connected either to the delivery side
33.3 mm (G1)-thread of the 120° swivelling connection 5 and / or of the horizontal connection 8. 1. Screw the tap connector 7 onto the pressure outlet 5 / 8 and tighten
it by hand.
2. Connect the pressure hose with hose connector 6 onto the tap connector 7.
3. OPERATION
DANGER! Electric shock! Risk of injury due to electric current. v Disconnect the product from the mains before you fill the pump.
To start the Automatic Home & Garden Pump [ Fig. O1 / O2 ]:
NOTE: The specified maximum selfpriming level (see 7. TECHNI CAL DATA) is reached only when the pump is full and the pressu re hose is held up high directly upstream of the pressure output during the first selfpriming phase. This ensures that the pumped medium cannot leak from the pressure hose. When using a full suction hose with a check valve, it is not necessary to hold up the pressure hose.
1. Unscrew the lid 9 of the filter chamber with the spanner > provided. 2. Slowly fill in the liquid to be pumped via the filler connection 0 up to
the overflow (approx. 2 to 3 l) until the water level no longer drops under the suction side inlet or the water flows out at the horizontal connector.
3. With fixed installation: Unscrew the cover r and fill with liquid until it
flows towards the horizontal connector. 4. Empty any water remaining in the delivery hose so that the air can
escape during filling and priming. 5. Open any shut-off devices in the delivery line (watering accessories,
tap, etc.) so that air can escape before the priming procedure begins. 6. With fixed installation: If the delivery line cannot be emptied due to
fixed installation, unscrew the cover r. Considerable amounts of liquid
may escape. Please keep a sufficiently large receptacle at hand for collection.
7. Tighten the lid 9 of the filter chamber up to the stopper <.
8. Without fixed installation: Lift up the delivery hose just behind the pressure outlet.
9. Plug the power plug of the connecting cable into a mains socket.
10. Push the on / off switch q to position I.
The on/off switch lights up and the pump starts.

3

GAR_01757-52.960.04_2024-06-27.indd 3

27.06.24 08:45

The suction process can take up to 6 min. If no water is pumped afterwards, the pump will shut down automatically and display Error 2 (see 6. TROUBLESHOOTING). 11. Close shut-off devices in the delivery pipeline again when the pump
begins to deliver water continuously. The pump turns off automatically approx. 10 seconds after closing the shutoff device. The pump is ready for operation (Standby).
Electronic control: The pump features an electronic controller. If the pressure level falls below the start-up pressure, the pump is started automatically. As soon as the water supply is no longer required, the pump is switched off automatically.
Low quantity programme and leakage warning: Leakage warning: In the event of a leakage or a dripping tap, the pressure constantly falls below the turn-on pressure and the pump switches itself on and off continuously. If the pump is constantly switched on and off, the pump switches off automatically to prevent unwanted water leakage (error 4 “Leakage warning” is displayed).
Low quantity programme: To prevent the pump from switching off earlier when used with low quantity of water (e.g. washing machines or drip irrigation), the leakage warning is only activated after 60 minutes. Switching the pump on and off cyclically during the small quantity program has no effect on the service life of the pump.

3. Loosen the cover r of the check valve with a suitable tool. 4. Remove the check valve t and clean it under running water. 5. Assemble the check valve t again in reverse order.
6. Start the pump (see 3. OPERATION).
5. STORAGE
To put into storage [ Fig. S1 ]: The product must be stored away from children.
1. Push the on / off switch q to position 0.
2. Disconnect the pump from the mains. 3. Open the consumer on the pressure side. 4. Remove the connected hoses on the pressure and suction side.
5. Unscrew drain bolt 1.
6. Tilt the pump to the suction and pressure side until water is no longer discharged from either side.
7. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations.
IMPORTANT! v Dispose of the product through or via your municipal recycling
collection centre.

Use of washing machines: Upon completion of the low quantity water supply cycle in washing machines, the 60-minute operating interval of the low quantity programme is automatically reset to normal operation of the pump and allows a trouble-free use of the washing machine for > 60 minutes.
For continuous drip irrigation: If the low quantity programme is to be used for more than 60 minutes, the irrigation must be disrupted for at least 5 minutes before the end of the 60 minute period. The low quantity programme can then be used for a further 60 minutes.
4. MAINTENANCE
DANGER! Electric shock! Risk of injury due to electric current. v Disconnect the product from the mains before you maintain the product.

6. TROUBLESHOOTING
DANGER! Electric shock! Risk of injury due to electric current. v Disconnect the product from the mains before you troubleshoot the product.

To troubleshoot with the error diagnosis system [ Fig. T1 ]:
The pump is equipped with an error diagnosis system which indicates
various error states via the error LED v.
1. Disconnect the pump from the mains.
2. Make the respective remedies from the table below.
3. Start the pump again. The error display has been cleared and the pump is ready for operation again.

Problem

Possible Cause

Remedy

To clean the filter [ Fig. M1 / M2 ]: 1. If applicable, close all the shutoff devices on the intake side.
2. Loosen the lid 9 of the filter chamber with the spanner > provided. 3. Remove the filter unit w / e vertically upwards. 4. Hold the cup w firmly, turn the filter e counterclockwise 1 and
remove the filter 2 (bayonet fitting).
5. Clean the cup w under running water and clean the filter e
e. g. with a soft brush. 6. Assemble the filter again in reverse order. 7. Start the pump (see 3. OPERATION).
To clean the check valve [ Fig. M3 / M4 ]:
CAUTION! The pump must not be operated without the check valve.
1. If applicable, close all the shut-off devices on the intake side. 2. Open all tapping points so that the pressure escapes on the pressure
side. Now close the tapping points again so that the connected pipes do not drain via the pump.

Error-LED flashes 1 time The pump does not pump water for 30 seconds during the (with a 2 second break) initial operation.

Pump does not suck water

Pump was not sufficiently

v Fill the pump and make sure

filled with liquid to be pumped. that water does not drain out

on the pressure side during

the suctioning process

(see 3. OPERATION).

Air cannot escape on the pres- v Open the pressure side sure side, because the pressure outlets (see 3. OPERATION). side outlets are closed.

Pump does not start

The pump housing has heated 1. Open possible shut-off device

up and the thermal circuit brea- in the pressure line (release

ker has been activated.

pressure).

2. Ensure sufficient ventilation and let the pump cool down for 20 min.

The impeller is blocked.

1. Loosen the impeller (see “To loosen the impeller”).
2. Let the pump cool down for 20 min.

Only for Art. 1758:

The flow sensor is dirty.

Flow sensor signal is faulty

v Clean the flow sensor (see “To clean the flow sensor”).

4

GAR_01757-52.960.04_2024-06-27.indd 4

27.06.24 08:45

Problem

Possible Cause

Remedy

Error-LED flashes

The pump does not pump water for 6 minutes during the

2 times (with a 2 second initial operation.

break)

Pump does not suck water

Problem on the suction side.

v Immerse the suction hose end under water.
v Eliminate any leak on the suction side.
v Clean the check valve on the suction line and check the installation direction.
v Clean the suction filter on the suction hose end.
v Clean the filter lid seal and turn the lid until the stopper (see 4. MAINTENANCE),
v Clean the filter in the pump.

Suction hose deformed or bent.

v Use a new suction hose.

Pump does not start

The thermal circuit breaker has been activated (motor overheated).

v Let the pump cool down for 20 min.

Error-LED flashes

The pump does not pump water for 30 seconds during the

3 times (with a 2 second current operation.

break)

Water supply disrupted on the suction side

Problem on the suction side.

v Immerse the suction hose end under water.
v Eliminate any leak on the suction side.
v Clean the check valve on the suction line and check the installation direction.
v Clean the suction filter on the suction hose end.
v Clean the filter lid seal and turn the lid until the stopper (see 4. MAINTENANCE),
v Clean the filter in the pump.

Suction hose deformed or bent. v Use a new suction hose.

Pump does not start

The thermal circuit breaker has been activated (motor overheated).

v Let the pump cool down for 20 min.

Only for Art. 1758:

The flow sensor is dirty.

Flow sensor signal is faulty

v Clean the flow sensor (see “To clean the flow sensor”).

Error-LED flashes

The pump switches off during on-going operation

4 times (with a 2 second after 60 minutes.

break)

Leakage warning is activated

Leak on pressure side (e. g. dripping tap).

v Eliminate any leak on the pressure side.

The maximum duration of the leakage warning (low quantity program 60 min. or 2 min.) has been exceeded.

v When using the low quantity programme, shorten the watering duration or interrupt for 5 minutes.
v Increase the water consumption.

The check valve is blocked.

v Clean the check valve (see “To clean the check valve”).

Only for Art. 1758:

The flow sensor is dirty.

Flow sensor signal is faulty

v Clean the flow sensor (see “To clean the flow sensor”).

Error-LED is off

Pump does not start or stops suddenly during operation

Mains plug is disconnected. v Connect the mains plug.

Power failure.

v Check the fuse and the cables.

RCD has triggered (residual current).

v Disconnect the pump and contact the GARDENA Service.

Electrical interruption.

v Disconnect the pump and contact the GARDENA Service.

Error-LED is off
Only for Art. 1757 (see fig. T4)

Pump frequently switches on and off without water retrieval.

Longer periods of non-use.

v Pull piston !K at the check
valve several times prior to commissioning after longer periods of non-use.

To loosen the impeller [ Fig. T2 ]: If the impeller is stuck due to dirt, the Error LED flashes 1 time (with a 2 second break).
1. Turn the motor shaft z with a screw driver.
This will loosen the blocked impeller. 2. Start the pump (see 3. OPERATION).
Only for Art. 1758: To clean the flow sensor [ Fig. T3 ]: If the flow sensor is stuck due to dirt, the Error LED flashes (with a 2 second break).
1. Loosen both screws u. 2. Remove the cover i. 3. Loosen the screw o and remove the clip p. 4. Loosen the cap a counterclockwise (e. g. with a screwdriver). 5. Remove and clean the impeller s.
6. Clean the housing of the flow sensor.
7. Assemble the impeller s again in reverse order. 8. First insert the cover i at the top and then tighten both screws u
at the bottom. 9. Start the pump (see 3. OPERATION).
NOTE: For any other malfunctions please contact the GARDENA service department. Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA.

7. TECHNICAL DATA

Automatic Home & Garden Unit Pump

Value (Art. 1757)

Mains voltage

V (AC)

220 ­ 240

Mains frequency

Hz

50

Rated Power / Standby consumption

W

800 / 1.5

Connection cable

m

1.5 (H07RN-F)

Max. delivery capacity

l/h

3500

Max. pressure

bar

4.0

Max. delivery head

m

40

Max. suction height

m

7

Cut-in pressure

bar

1.9 ± 0.2

Permitted internal pressure (delivery side)

bar

6

Weight

kg

8.1

Sound power level LWA1): measured/guaranteed Uncertainty k 1)
WA

dB (A)

77 / 81 4

Measuring process complying with: 1) RL 2000/14/EC

Value (Art. 1758)
220 ­ 240 50 1100 / 1.5 1.5 (H07RN-F) 4000 4.5 45 8 1.9 ± 0.2 6 12.5
83 / 83 1

8. ACCESSORIES

GARDENA Suction Hoses
GARDENA Suction Hose Fittings GARDENA Suction Filter with Backflow Preventer GARDENA Bore Hole Suction Hose
GARDENA Pump Preliminary Filter GARDENA Pump Connection Set GARDENA Pump Connection Set

Kink and vacuum-resistant, sold by the metre with 19 mm (3/4″), 25 mm (1″) or 32 mm (5/4″) diameter without fittings or in fixed lengths complete with fittings, suction filter and backflow preventer.

For vacuum-resistant connection of the pump Art. 1723 / 1724 to the suction hose sold by the metre.

To equip suction hoses with Backflow Preventer Art. 1726 / 1727 sold by the metre.

For vacuum-resistant connection of the pump Art. 1729 to boreholes or pipe networks. Length 0.5 m. With 33.3 mm (G1) female thread at both ends.

Recommended for pumping sandy water.

Art. 1730 / 1731

Connection Set for 1/2″ Pressure Hoses.

Art. 1750

Connection Set for 3/4″ Pressure Hoses.

Art. 1752

5

GAR_01757-52.960.04_2024-06-27.indd 5

27.06.24 08:45

9. WARRANTY / SERVICE
9.1 Product registration:
Please register your product at gardena.com/registration.
9.2 Service:
Please find the current contact information of our service on the back page and online: · Australia: https://www.gardena.com/au/support/advice/contact/ · New Zealand: https://www.gardena.com/nz/support/advice/contact/
9.3 Warranty:
Husqvarna provides a manufacturer’s warranty against faulty workmanship in manufacture and / or defective components to initial purchaser for each new GARDENA branded product produced by Husqvarna and purchased in Australia. To make a valid claim under this manufacturer’s warranty the product and proof of purchase must be provided to the retailer. This warranty does not cover damage caused by misuse, neglect, adjustments and / or modifications by the consumer or normal wear and tear, the costs of shipping and handling, travel expense, lost time, or pickup and delivery.
Australia
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Husqvarna Australia Pty Ltd (ABN 45 115 475 619) 4 Pioneer Avenue Tuggerah NSW 2259 Tel: 1300 804 213
New Zealand
This manufacturer’s warranty is in addition to the rights and remedies provided by the New Zealand Consumer Guarantees Act. Husqvarna New Zealand Ltd (Company No. 111861) 51 Aintree Avenue Airport Oaks, Manukau 2022 Tel: 09 920 2410

6
GAR_01757-52.960.04_2024-06-27.indd 6

27.06.24 08:45

Page 7 width 2 mm less: 208 mm

Performance characteristics

Classic 3500/4

bar

m

5

50

4

40

3

30

2

20

1

10

0

0

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 l/h

Comfort 4000/5

bar

m

5

50

4

40

3

30

2

20

1

10

0

0

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 l/h

GAR_01757-52.960.04_2024-06-27.indd 7

7
27.06.24 08:45

Fold-out Page width 5 mm less: 205 mm

I1

I2

I3

O1

Art. 1723 / Art. 1724
4 3 2

5 8
Art. 1752
76

ßA
9 r
q 0

1

a
r t
Art. 1758
i

O2
ßA 9 0
M4

ßA M1
9
e w
q w

M2 r

2

t

1e

Art. 1757

S1

T1

q

ßv

q q
1

M3 q
T2 z

T3

T4

Only for Art. 1757

s u

p

a

o

GAR_01757-52.960.04_2024-06-27.indd 8

8
27.06.24 08:45

Fold-out Page width 5 mm less: 205 mm

9
GAR_01757-52.960.04_2024-06-27.indd 9

27.06.24 08:45

Page 10 width 2 mm less: 208 mm

Deutschland / Germany GARDENA Manufacturing GmbH Central Service Hans- Lorenser-Straße 40 D-89079 Ulm Produktfragen: (+49) 731 490-123 Reparaturen: (+49) 731 490-290 www.gardena.com/de/kontakt
Albania KRAFT SHPK Autostrada Tirane-Durres Km 7 1051 Tirane Phone: (+355) 69 877 7821 info@kraft.al
Argentina ROBERTO C. RUMBO S.R.L. Predio Norlog Lote 7 Benavidez. ZC: 1621 Buenos Aires Phone: (+54) 11 5263-7862 ventas@rumbosrl.com.ar
Armenia AES Systems LLC Marshal Babajanyan Avenue 56/2 0022 Yerevan Phone: (+374) 60 651 651 masisohanyan@icloud.com
Australia Husqvarna Australia Pty. Ltd. Locked Bag 5 Central Coast BC NSW 2252 Phone: (+ 61) (0) 2 4352 7400 customer.service@husqvarna.com.au
Austria / Österreich Husqvarna Austria GmbH Industriezeile 36 4010 Linz Tel.: (+43) 732 77 01 01-485 www.gardena.com/at/service/beratung/kontakt/
Azerbaijan Proqres Xüsusi Firmasi Aliyar Aliyev 212, Baku, Azerbaijan Sales: +994 70 326 07 14 Aftersales: +994 77 326 07 14 www.progress-garden.az info @progress-garden.az
Bahrain M.H. Al-Mahroos BUILDING 208, BLOCK 356, ROAD 328 Salhiya Phone: +973 1740 8090 almahroos@almahroos.com
Belarus / « » 220118, . , , 7 . (+375) 17 257 00 33 mg@mastergarden.by
Belgium Husqvarna Belgium nv Gardena Division Leuvensesteenweg 542 Planet II E 1930 Zaventem België
Bosnia / Herzegovina Silk Trade d.o.o. Poslovna Zona Vila Br. 20 Phone: (+387) 61 165 593 info@silktrade.com.ba
Brazil Nordtech Maquinas e Motores Ltd. Avenida Juscelino Kubitschek de Oliveira Curitiba 3003 Brazil Phone: (+55) 41 3595-9600 contato@nordtech.com.br www.nordtech.com.br
Bulgaria AGROLAND . 8 , 13 5 1700 .: (+359) 24 66 6910 info@agroland.eu
Canada / USA GARDENA Canada Ltd. 125 Edgeware Road Unit 15 A Brampton L6Y 0P5 ON, Canada Phone: (+1) 905 792 93 30 gardena.customerservice@husqvarnagroup.com
Chile REPRESENTACIONES JCE S.A. AV. DEL VALLE NORTE 857 PISO 4 HUECHURABA, SANTIAGO, CHILE Phone: (+ 56) 2 2414 2600 contacto@jce.cl
China Husqvarna (Shanghai) Management Co., Ltd. 3F, Benq Square B, No 207, Song Hong Rd., Chang Ning District, Shanghai, PRC. 200335 207 B3, : 200335
Colombia Equipos de Toyama Colombia SAS Cra. 68 D No 25 B 86 Of. 618 Edificio Torre Central Bogota Phone: +57 (1) 703 95 20 /
+57 (1) 703 95 22 servicioalcliente@toyama.com.co www.toyama.com.co
Costa Rica Exim CIA Costa Rica Calle 25A, B°. Montealegre Zapote San José Costa Rica Phone: (+506) 2221-5654 / (+506) 2221-5659 eximcostarica@gmail.com

Croatia Husqvarna Austria GmbH Industriezeile 36 4010 Linz Phone: (+43) 732 77 01 01-485 service.gardena@husqvarnagroup.com
Cyprus Pantelis Papadopoulos S.A. 92 Athinon Avenue Athens 10442 Greece Phone: (+30) 21 0519 3100 infocy@papadopoulos.com.gr
Czech Republic Gardena Service Center Vrbno c/o Husqvarna Manufacturing CZ s.r.o. Jesenická 146 79326 Vrbno pod Pradedem Phone: 800 100 425 servis@gardena.cz
Denmark GARDENA DANMARK Lejrvej 19, st. 3500 Værløse Tlf.: (+45) 70 26 47 70 gardenadk@husqvarnagroup.com www.gardena.com/dk
Dominican Republic BOSQUESA, S.R.L Carretera Santiago Licey Km. 5 ½ Esquina Copal II. Santiago De Los Caballeros 51000 Dominican Republic Phone: (+1) 809-562-0476 contacto@bosquesa.com.do
Egypt Universal Agencies Co 26, Abdel Hamid Lotfy St. Giza Phone: (+20) 3 761 57 57
Estonia Husqvarna Eesti OÜ Valdeku 132 EE-11216 Tallinn info@gardena.ee
Finland Oy Husqvarna Ab Juurakkotie 5 B 2 01510 Vantaa www.gardena.fi
France Husqvarna France 9/11 Allée des pierres mayettes 92635 Gennevilliers Cedex France http://www.gardena.com/fr N° AZUR: 0 810 00 78 23 (Prix d’un appel local)
Georgia Transporter LLC #70, Beliashvili street 0159 Tbilisi, Georgia Number: (+995) 322 14 71 71 info@transporter.com.ge www.transporter.com.ge
Service Address and Importer to Great Britain Husqvarna UK Ltd Preston Road Aycliffe Industrial Park Newton Aycliffe County Durham DL5 6UP Phone: (+44) (0) 344 844 4558 info.gardena@husqvarna.co.uk
Greece . . 92 ..104 42 . (+30) 210 5193 100 info@papadopoulos.com.gr
Hong Kong Tung Tai Company 151-153 Hoi Bun Road Kwun Tong, Kowloon Hong Kong Phone: (+852) 3583 1662 admin@tungtaico.com
Hungary Husqvarna Magyarország Kft. Ezred u. 1 ­ 3 1044 Budapest Phone: (+36) 1 251-4161 vevoszolgalat.husqvarna@husqvarna.hu
Iceland BYKO ehf. Skemmuvegi 2a 200 Kópavogur Phone: (+354) 515 4000 byko@byko.is
MHG Verslun ehf Víkurhvarf 8 203 Kópavogur Phone: (+354) 544 4656
India B K RAMAN AND CO Plot No. 185, Industrial Area, Phase-2, Ram Darbar Chandigarh 160002 India Phone: (+91) 98140 06530 raman@jaganhardware.com
Iraq Alshiemal Alakhdar Company Al-Faysalieah, Near Estate Bank Mosul Phone: (+964) 78 18 18 46 75
Ireland Liffey Distributors Ltd. 309 NW Business Park, Ballycoolen 15 Dublin Phone: (+353) 1 824 2600 info@liffeyd.com

10
GAR_01757-52.960.04_2024-06-27.indd 10

Israel HAGARIN LTD. 2 Nahal Harif St. 8122201 Yavne internet@hagarin.co.il Phone: (+972) 8-932-0400
Italy Husqvarna Italia S.p.A. Centro Direzionale Planum Via del Lavoro 2, Scala B 22036 ERBA (CO) Phone: (+39) (0) 31 4147700 assistenza.italia@it.husqvarna.com
Japan Husqvarna Zenoah Co. Ltd. Japan 1-9 Minamidai, Kawagoe 350-1165 Saitama Japan gardena-jp@husqvarnagroup.com
Kazakhstan “” Russian : , . , . , 155/1 .: (+7) (727) 355 64 00 /
(+7) (700) 355 64 00 lamed@lamed.kz
Kazakh -: , ., . , 155/1 .: (+7) (727) 355 64 00 /
(+7) (700) 355 64 00 lamed@lamed.kz
Kuwait Palms Agro Production Co Al Rai- Fourth Ring Road ­ Block 56. P.O Box: 1976 Safat 13020 Al-Rai Phone: (+965) 24 73 07 45 info@palms-kw.com
Kyrgyzstan OOsO Alye Maki Av. Moladaya Guardia 83 720014 Bishkek Phone: (+996) 312 322115
Latvia Husqvarna Latvija SIA Ulbrokas 19A LV-1021 Rga info@gardena.lv
Lebanon Technomec Safra Highway (Beirut ­ Tripoli) Center 622 Mezher Bldg. P.O.Box 215 Jounieh Phone: (+961) 9 853527 /
(+961) 3 855481 tecnomec@idm.net.lb
Lithuania UAB Husqvarna Lietuva Ateities pl. 77C LT-52104 Kaunas info@gardena.lt
Luxembourg Magasins Jules Neuberg 39, rue Jacques Stas Luxembourg-Gasperich 2549 Case Postale No. 12 Luxembourg 2010 Phone: (+352) 40 14 01 api@neuberg.lu
Malaysia Glomedic International Sdn Bhd Jalan Ruang No. 30 Shah Alam, Selangor 40150 Malaysia Phone: (+60) 3-7734 7997 oase@glomedic.com.my
Malta I.V. Portelli & Sons Ltd. 85, 86, Triq San Pawl Rabat – RBT 1240 Phone: (+356) 2145 4289
Mauritius Espace Maison Ltée La City Trianon, St Jean Quatre Bornes Phone: (+230) 460 85 85 digital@espacemaison.mu
Mexico AFOSA Av. Lopez Mateos Sur # 5019 Col. La Calma 45070 Zapopan, Jalisco, Mexico Phone: (+52) 33 3818-3434 isolis@afosa.com.mx
Moldova Convel SRL Republica Moldova, mun. Chisinau, sos. Muncesti 284 Phone: (+373) 22 857 126 www.convel.md
Mongolia Soyolj Gardening Shop Narnii Rd Ulaanbaatar 14230 Mongolia Phone: +976 7777 5080 soyolj@magicnet.mn
Morocco Proekip 64 Rue de la Participation Casablanca-Roches Noires 20303 Morocco Phone: (+212) 661342107 hicham.hafani@proekip.ma
Netherlands Husqvarna Nederland B.V. GARDENA Division Postbus 50131 1305 AC ALMERE Phone: (+31) 36 521 00 10 info@gardena.nl
Neth. Antilles Jonka Enterprises N.V. Sta. Rosa Weg 196 P.O. Box 8200 Curaçao Phone: (+599) 9 767 66 55 info@jonka.com

New Zealand Husqvarna New Zealand Ltd. PO Box 76-437 Manukau City 2241 Phone: (+64) (0) 9 9202410 support.nz@husqvarna.co.nz
North Macedonia Sinpeks d.o.o. Ul. Kravarski Pat Bb 7000 Bitola Phone: (+389) 47 20 85 00 sinpeks@mt.net.mk
Norway Husqvarna Norge AS Gardena Division Trøskenveien 36 1708 Sarpsborg info@gardena.no
Northern Cyprus Mediterranean Home & Garden No 150 Alsancak, Karaolanolu Caddesi Girne Phone: (+90) 392 821 33 80 info@medgardener.com
Oman General Development Services PO 1475, PC – 111 Seeb 111 Oman Phone: 96824582816 gdsoman@gdsoman.com
Paraguay Agrofield SRL AV. CHOFERES DEL CHACO 1449 C/25 DE MAYO Asunción Phone: (+595) 21 608 656 consultas@agrofield.com.py
Peru Sierras y Herramientas Forestal SAC Av. Las Gaviotas 833, Chorrillos Lima Phone: (+51) 1 2 52 02 52 supervisorventas1@siersac.com www.siersac.com
Philippines Royal Dragon Traders Inc 10 Linaw Street, Barangay Saint Peter Quezon City 1114 Philippines Phone: (+63) 2 7426893 aida.fernandez@rdti.com.ph
Poland Gardena Service Center Vrbno c/o Husqvarna Manufacturing CZ s.r.o. Jesenická 146 79326 Vrbno pod Pradedem Czech Republic Phone: (22) 336 78 90 serwis@gardena.pl
Portugal Husqvarna Portugal, SA Lagoa – Albarraque 2635 – 595 Rio de Mouro Phone: (+351) 21 922 85 30 Fax: (+351) 21 922 85 36 info@gardena.pt
Romania Madex International Srl Soseaua Odaii 117 – 123, RO 013603 Bucureti, S1 Phone: (+40) 21 352 7603 madex@ines.ro
Russia / ,,” 141400, ., . , , 39, .6 ,, “, 02_04 http://www.gardena.ru
Saudi Arabia SACO Takhassusi Main Road P.O. Box: 86387 Riyadh 12863 40011 Saudi Arabia Phone: (966) 11 482 8877 webmaster@saco-ksa.com
Al Futtaim Pioneer Trading 5147 Al Farooq Dist. Riyadh 7991 Phone: (+971) 4 206 6700 Owais.Khan@alfuttaim.com
Serbia Domel d.o.o. Slobodana uria 21 11000 Belgrade Phone: (+381) 11 409 57 12 ofgce@domel.rs
Singapore Hy-Ray PRIVATE LIMITED 40 Jalan Pemimpin #02-08 Tat Ann Building Singapore 577185 Phone: (+65) 6253 2277 info@hyray.com.sg
Slovak Republic Gardena Service Center Vrbno c/o Husqvarna Manufacturing CZ s.r.o. Jesenická 146 79326 Vrbno pod Pradedem Phone: 0800 154044 servis@gardena.sk
Slovenia Husqvarna Austria GmbH Industriezeile 36 4010 Linz Phone: (+43) 732 77 01 01-485 service.gardena@husqvarnagroup.com
South Africa Husqvarna South Africa (Pty) Ltd Lifestyle Business Park ­ Ground Floor Block A Cnr Beyers Naude Drive and Ysterhout Road Randpark Ridge, Randburg Phone: (+27) 10 015 5750 service@gardena.co.za

South Korea Kyung Jin Trading Co., Ltd 8F Haengbok Building, 210, Gangnam- Daero 137-891 Seoul Phone: (+82) 2 574 6300 kjh@kjh.co.kr Spain Husqvarna España S.A. Calle de Rivas nº 10 28052 Madrid Phone: (+34) 91 708 05 00 atencioncliente@gardena.es Sri Lanka Hunter & Company Ltd. 130 Front Street Colombo Phone: 94-11 232 81 71 hunters@eureka.lk Suriname Deto Handelmaatschappij N.V. Kernkampweg 72-74 P.O. Box: 12782 Paramaribo Suriname Phone: (+597) 43 80 50 info@deto.sr Sweden Husqvarna AB / GARDENA Sverige Drottninggatan 2 561 82 Huskvarna Sverige Phone: (+46) (0) 36-14 60 02 service@gardena.se Switzerland / Schweiz Husqvarna Schweiz AG Consumer Products Industriestrasse 10 5506 Mägenwil Phone: (+ 41) (0) 62 887 37 90 info@gardena.ch Taiwan Hong Ying Trading Co., Ltd. No. 46 Wu-Kun-Wu Road New Taipei City Phone: (+886) (02) 2298 1486 salesgd1@7friends.com.tw Tajikistan ARIERS JV LLC 39, Ayni Street, 734024 Dushanbe, Tajikistan Thailand Spica Co. Ltd 243/2 Onnuch Rd., Prawat Bangkok 10250 Thailand Phone: (+66) (0)2721 7373 surapong@spica-siam.com Tunisia Société du matériel agricole et maritime Nouveau port de peche de Sfax Bp 33 Sfax 3065 Phone: (+216) 98 419047/
(+216) 74 497614 commercial@smamtunisia.com Türkiye Dost Bahçe Yunus Mah. Adil Sk. No:3 Kartal Istanbul 34873 Türkiye Phone: (+90) 216 389 39 39 Turkmenistan I.E. Orazmuhammedov Nurmuhammet 80 Ataturk, BERKARAR Shopping Center, Ground floor, A77b, Ashgabat 744000 TURKMENISTAN Phone: (+993) 12 468859 Mob: (+993) 62 222887 info@jayhyzmat.com / bekgiyev@jayhyzmat.com www.jayhyzmat.com UAE Al-Futtaim ACE Company L.L.C Building, Al Rebat Street Festival City, Dubai 7880 UAE Phone: (+971) 4 206 6700 ace@alfuttaim.ae
Ukraine / «» 4 08130, . – -. . .: (+38) 0 800 503 000 Uruguay FELI SA Entre Ríos 1083 11800 Montevideo Phone: (+598) 22 03 18 44 info@felisa.com.uy Uzbekistan AGROHOUSE MChJ O’zbekiston, 111112 Toshkent viloyati Toshkent tumani Hasanboy QFY, THAY yoqasida Phone: (+998)-93-5414141 /
(+998)-71-2096868 info@agro.house www.agro.house Vietnam Vision Joint Stock Company BT1-17, Khu biet thu ­ Khu oan ngoai giao Nguyen Xuan Khoat Xuan inh, Bac Tu Liem Hanoi, Vietnam Phone: (+8424)-38462833/34 quynhnm@visionjsc.com.vn Zimbabwe Cutting Edge 159 Citroen Rd, Msasa Harare Phone: (+263) 8677 008685 sales@cuttingedge.co.zw
1757-52.960.04/0624 © GARDENA Manufacturing GmbH D-89079 Ulm http://www.gardena.com
1

27.06.24 08:45

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals