CALEFFI COMBO20A Combo Valve Kits Instruction Manual
- September 7, 2024
- CALEFFI
Table of Contents
COMBO20A Combo Valve Kits
“`html
Product Information
Specifications:
- Product Name: COMBO20A 20mm Caleffi Combo Valve Kit
- Manufacturer: Waterware
- Valve Size: 20mm
- Components: Cold water expansion valve, cylinder drain, check
valve, cylinder isolator, tempering valve feed
Product Usage Instructions:
Installation Configuration:
Before installing the COMBO20A Combo Valve Kit, ensure
compliance with local plumbing standards and regulations in New
Zealand and Australia. The valve train should connect directly to
the bottom of the cylinder via the cylinder isolation valve.
Important Tips:
- Ensure the hot water temperature does not exceed 50°C
- Connect the cold supply appropriately
Inlet Manifold (Left or Right Hand Entry):
The Inlet Manifold includes a cold water expansion valve,
cylinder drain, 20mm check valve non-return cold water entry,
cylinder isolator, and a cold balanced tempering valve feed. To
drain the hot water cylinder, follow these steps:
-
Turn the expansion valve knob after closing the cold
supply -
Open a hot water tap to allow air into the system and prevent
vacuum formation
For a quick installation video, scan the provided QR code.
FAQ:
Q: How do I ensure proper drainage of the hot water
cylinder?
A: To drain the hot water cylinder using the
COMBO20A Combo Valve Kit, turn the expansion valve knob after
closing the cold supply. Open a hot water tap to allow air into the
system and prevent vacuum formation.
“`
Product Warranty To be read in conjunction with and subject to warranty
conditions and exclusions found in this document. Claims that instructions
were missing are not accepted as a means of avoiding this condition. From date
of purchase, Waterware Sales Ltd warrants the following to be free from
manufacturing defect for 5 years on parts and labour. Warranty conditions and
exclusions; This limited warranty is not transferable, and rests with the
original householder. If any fault arising from the manufacturing processes is
found in a new product and if after consultation with Waterware, the product
is returned, within the stated warranty period for that product, for
inspection and or testing, Waterware will repair or exchange the product at
its sole discretion. Waterware Service Ltd shall in no way be liable for any
loss, damage (direct, indirect or consequential), cost or expense suffered or
incurred by the purchaser. Any costs associated with the removal, replacement
and return of any faulty product are not accepted without prior arrangement
with Waterware. Under no circumstances will such costs be accepted by
Waterware for products purchased and installed in remote, rural or locations
greater than 50km’s from the point of purchase. Warranty does not apply where
faults arise from; · Normal wear and tear of perishable components like
working seals and surface finishes. · Normal maintenance, cleaning or tuning
requirements or faults that are a result of minimum
maintenance requirements not being followed. · Foreign matter in the water
supplies. · Water supplies that do not meet normal expected municipal water
quality standards. · Installation in a manner not in accordance with the
manufacturers installation instructions or
relevant NZ and or Australian Standards and local plumbing codes including
G12. · Environment operating conditions that are outside the minimum and or
maximum
recommendations Evidence must be produced which confirms the relevant product
was purchased from a known customer of Waterware to validate any claim.
Obligations accepted by Waterware are in addition to all other rights and
remedies had by the Purchaser in law in respect of the product and does not
limit the right the Consumer may have under the Consumers Guarantee Act 1993.
Subject to the exceptions and conditions previously listed, all expressed or
implied conditions, statements warranties as to the quality of fitness on any
purpose of a product or otherwise are hereby expressly excluded to the fullest
extent permitted by law except under conditions and warrants which cannot be
legally excluded by law and which are intended in the contract for the supply
of the valve by the Trade Practises and any other Act of Law.
PH 09 273 9191 | info@waterware.co.nz PO Box 58 776 Botany, Manukau
waterware.co.nz
GENERAL
PLUMBING
COMBO VALVE KITS Installation Manual
COMBO20A 20mm Caleffi combo set
waterware.co.nz
INSTALLATION CONFIGURATION
Installations should firstly conform to any relevant local requirements, NZ
and or Australian plumbing standards. The valve train connects directly to the
bottom of the cylinder via the cylinder isolation valve. Important tips;
· The manifold inlet and cold water expansion adaptors can be swapped left to
right to provide either left or right hand entry to the manifold.
· The primary isolating valve provided can be located on the PRV as shown for
ease of maintenance. · Use only synthetic thread seal or tape on any
connections to the hot water cylinder.
50 C Hot
Cold Supply
INLET MANIFOLD (LEFT OR RIGHT HAND ENTRY)
The Inlet Manifold provides a cold water expansion valve, a cylinder drain, a
20mm check valve non-return cold water entry, a cylinder isolator and a 20mm
cold balanced tempering valve feed.
Inlet manifold features · The manifold inlet and cold water expansion adaptors
can be swapped left to right to provide either left or right hand entry to the
manifold. The adaptors use o-ring seals and so do not require thread tape or
similar. · The cylinder inlet isolator also uses o-ring seals. The flow can be
isolated using a spanner or similar to turn the hex shaped cap that drives the
isolator spindle.
Cold water expansion valve function The cold water expansion valve will start
to vent and then discharge at a pressure greater than 8 bar inside the
cylinder. As the cylinder heats and its contents expand, the volume of
discharged water could reach 3% of the cylinders total capacity during the
process. For example a 180 litre cylinder could vent 5.4 litres when heated
from cold. NOTE: The drain connection from the cold water expansion valve
should only vent to atmosphere and not to upstream pressure. No air break is
required unless the drain is over 10m in length.
To drain the hot water cylinder To drain the hot water cylinder, turn the
expansion valve knob having previously closed the cold supply. Ensure a hot
water tap is open to allow air into the system and prevent a vacuum being
formed in the system.
Cold water expansion valve specifications Factory set 800kPa Stainless steel
seat Maximum opening pressure + 20% Minimum reseating pressure -20% Maximum
Temperature 110ºC
Scan me to watch a quick installation video
Cold water expansion & cylinder drain
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>