CALEFFI 116 Series ThermoSetter Thermal Balancing Valve Installation Guide
- June 11, 2024
- CALEFFI
Table of Contents
16 Series ThermoSetter Thermal Balancing Valve
Installation Guide
116 Series ThermoSetter Thermal Balancing Valve
Manufacturer & Product:| Califia 116, 1164 Thermometer
Balancing_Valve-ThermoSetter-Caleffi-LF_Brass-116.rfa
---|---
Files:| Balancing_Valve-ThermoSetter-Caleffi-LF_Brass-1164.rfa
Type Catalogs:| Balancing_Valve-ThermoSetter-Caleffi-LF_Brass-116.txt
Balancing_Valve-ThermoSetter-Caleffi-LF_Brass-1164.txt
Rendering file:| Not Applicable
Schedule file:| Not Applicable
This family contains the following main variations or types:
- Sizes include 0.5 in., 0.75 in., 1 in., and 1.25 in. with FNPT connection type
- Options of adding isolation valve at both ports
- Option to add temperature gauge
- Option to add check valve
- Option to select one of 1161, 1162, 1163, 1166 Series (Not applicable for 1164 Series)
All the above variations are included as separate types in the type catalog of
each family Instance Properties
Here is a curated list of notable parameters for the Revit user within the
Caleffi 116, 1164 ThermoSetter family.
Construction
▼ Thermo-electric Actuator Selection (default)1. 656404 Actuator (default) 2.
656414 Actuator (default)| Specify one of the listed actuators (Applicable for
1161/2/3/6 Thermal Setters only).
This shows a checkbox based on selection above.
This shows a checkbox based on selection above.
Mechanical – Flow
Design Flow Rate (default)| This tells you the flow that this component is
reading in the system.
Flow Warning (default)| This tells you a warning if the flow rate exceeds the
maximum allowable.
Mechanical – Loads
Pressure Drop Feet of Water (default)| Specify the pressure drop in feet of
water.
System Pressure Drop (default)| This tells you the system pressure drop.
Type Properties
Here is a curated list of notable parameters for the Revit user within the Caleffi 116, 1164 ThermoSetter family. 1163 ThermoSetter
Identity Data|
---|---
Assembly Code| D3040
Contact URL| http://www.caleffi.com/usa/en-us/contacts/contact-us
Copyright| ©Caleffi North America
Cost|
Description| Adjustable thermal balancing valve for domestic hot water
recirculation circuits.
Family Version|
Keynote|
Manufacturer| Caleffi North America, Inc.
Model| 116340A
Product Page URL| https://www.caleffi.com/usa/en-us/catalogue
/thermosettertm-thermal-balancingvalve-thermal-disinfection-116240a[
](https://www.caleffi.com/usa/en-us/catalogue/thermosettertm-thermal-
balancingvalve-thermal-disinfection-116240a)
Type Comments|
Type Image
Series| 1163 Series
Standards| NSF/ANSI/CAN 61; NSF/ANSI/CAN 372; S.3874; Reduction of Lead in
Drinking Water
Act; Vermont Act 193; Maryland’s Lead-Free Law Hb.373
URL| https://www.caleffi.com/usa/en-us
1164 ThermoSetter
Identity Data|
---|---
Assembly Code| D3040
Contact URL| http://www.caleffi.com/usa/en-us/contacts/contact-us
Copyright| ©Caleffi North America
Cost|
Description| Adjustable thermal balancing valve for domestic hot water
recirculation circuits.
Family Version| 1
Keynote|
Manufacturer| Caleffi North America, Inc.
Model| 116440A
Product Page URL| https://www.caleffi.com/usa/en-us/catalogue
/thermosettertm-thermal-balancingvalve-116440a
Type Comments|
Type Image|
Series| 1164 Series
Standards| NSF/ANSI/CAN 61; NSF/ANSI/CAN 372; S.3874; Reduction of Lead in
Drinking Water
Act; Vermont Act 193; Maryland’s Lead-Free Law Hb.373
URL| https://www.caleffi.com/usa/en-us
Halftone text in the property tables indicates that the value is locked from
editing.
*Indicates Shared Parameter and can be scheduled
Rendering
Note: Standard Calefied materials are imported. These may be modified,
but please ensure that the modification selection matches an actual
manufacturer supplied option.
Loading and Placing into the Project
To work with the Califia 116, 1164 Thermometer in Revit, a family and a type
catalog are provided. Navigate to the Insert Tab > Load Family button on the
Revit ribbon to load the family. Be sure the type catalog (.txt) file is
located in the same folder as the family you are loading.
Please ensure that the visibility settings within the project are modified to
have the Piping category visible. A. 1161 Thermometer with 0.5 in. FNPT connection
B. 1161 Thermometer with 0.5 in. FNPT connection, isolation valves, check,
temperature gauge
C. 1164 Thermometer with 0.5 in. FNPT connection
D. 1164 Thermometer with 0.5 in. FNPT connection, isolation valves, check,
temperature gauge
Project Behavior
One way to place a Caleffi 116, 1164 ThermoSetter is to go to the Systems Tab
on the Revit ribbon and navigate to the Component button with Place a
Component fly-out selected.
Figure 5.2 – The Califia 116, 1164 Thermometer families can be found under
pipe accessories in the project browser and placed directly onto pipe of the
same size. It will then read flows and consider pressure drop in the system
Schedule Creation
Within the type and instance properties dialogues, the Revit user will find
useful information for scheduling purposes such as Type, Part Description,
Part Number/Model, Family Version, Manufacturer, Series, & Product Page URL.
The resulting Pipe Accessories schedule in your project will show
counts/quantities of the Caleffi 116, 1164 Thermometer as well as separate
quantities/counts of any separately purchased accessory products that do not
come in box with the Caleffi 116, 1164 ThermoSetter.
Caleffi North America, Inc.
3883 West Milwaukee Road Milwaukee,
WI 53208 T: 414.238.2360 F: 414138.2366
References
- Caleffi Hydronic Solutions | Caleffi S.p.a.
- Get in touch with Caleffi US
- Caleffi S.p.A. | Hydronic Solutions