FuturaSun Silk Nova EU photovoltaic module Owner’s Manual

September 6, 2024
FuturaSun

FuturaSun Silk Nova EU photovoltaic module

Product Usage Instructions

Installation Guide

  1. Ensure proper mounting surface and secure installation area.
  2. Connect the cables according to the provided wiring diagram.
  3. Avoid shading the solar panels for optimal performance.

Maintenance

  • Regularly clean the surface of the solar panels with a soft cloth and mild detergent to remove dirt and debris.

Troubleshooting

  • If the solar panels are not producing power, check the connections and ensure there are no obstructions blocking sunlight.

FAQ

Frequently Asked Questions

  • Q: What is the warranty on the product?
    • A: The product guarantees are provided by the Italian headquarters, ensuring performance and quality.
  • Q: Can the solar panels be used in all weather conditions?
    • A: The solar panels are designed to withstand various weather conditions, but optimal performance may vary based on environmental factors.
  • Q: How should I dispose of the product at the end of its life cycle?
    • A: Please refer to local regulations for proper disposal methods of electronic products to ensure environmental responsibility.

KEY BENEFITS AND FEATURES

  • Power of 430 Watt
  • European supply chain to reduce the carbon footprint
  • Made in Europe
  • 108 M10 n-type half-cut cells
  • High efficiency and enhanced low light performance
  • 1722 x 1134 x 30 mm

Specification

  • Maximum power: 430 W
  • Maximum efficiency: 22 %

Guarantee

Performance guarantee

  • 25-years performance warranty with max power decrease from first year 0.4%/year
  • 99% at the end of first year
  • 92% at the end of 20th year
  • 89% at the end of 25th year

Product guarantees

  • 15-year product warranty
  • Third-party product liability insurance
  • All FuturaSun’s modules are designed and guaranteed by the Italian headquarters

All images shown are for illustration purpose only, product appearance may vary according to the installation, light and ambient reflection.

Specifications

Mechanical Specifications

Dimensions 1722 x 1134 x 30 mm
Weight 20.8 kg
Glass High transmission, Low iron, Tempered, ARC, Thickness 3.2 mm
Cells 108 monocrystalline half-cut MBB n-type cells 182 x 91 mm
Frame Anodized aluminium frame with mounting and drainage holes
Junction boxes Certified according to IEC 62790, IP 68 approved, 3 bypass

diodes
Cables| Solar cable, length 1100 mm assembled with 4mm² compatible connectors
Backsheet| Composite Multilayer film – white
Maximum reverse current (Ir)| 25 A
Maximum system voltage| 1000 or 1500 V
Mechanical load (snow)| Design load: 3600 Pa, (5400 Pa including safety factor 1.5)
Mechanical load (wind)| Design load: 1600 Pa, (2400 Pa including safety factor 1.5)

*Electrical data – STC / FU 430 MV**

Sorting tolerance W 0/+5
Module power (Pmax) W 430
Open circuit voltage (Voc) V 38.24
Short circuit current (Isc) A 14.31
Maximum power voltage (Vmpp) V 31.72
Maximum power current (Impp) A 13.56
Module efficiency % 22.00

Electrical data – NOCT / FU 430 MV**

Module power (Pmax) W 325
Open circuit voltage (Voc) V 36.36
Short circuit current (Isc) A 11.56
Maximum power voltage (Vmpp) V 29.65
Maximum power current (Impp) A 10.96

Temperature ratings

Temperature coefficient Isc %/°C 0.045
Temperature coefficient Voc %/°C -0.25
Temperature coefficient Pmax %/°C -0.29
NOCT** °C 45 ± 2
Operating temperature °C from -40 to +85

Certifications

Factory ISO 9001 – 14001 – 45001
Product IEC EN 61730, IEC EN 61215, Fire Class C,

Class 1 UNI9177

Packaging

Quantity / Pallet 36 pcs
Container 40’ HC 936 pcs / 26 pallets

The information included in this module datasheet is subject to change without notice and is provided for informational purposes only. No contractual rights are established or should be inferred because of user’s reliance on the information contained in this module datasheet. Please refer to the appropriate module user guide and module product specification document for more detailed technical information regarding module performance, installation and use.

*Standard Test Conditions STC: 1000 W/m2 – AM 1.5 – 25 °C – tolerance: Pmax (±3%). Voc (±4%). Isc (±5%)
**Nominal Operating Cell Temperature NOCT: 800 W/m2 – T=45 °C – AM 1.5

Contact

For detailed information, please refer to the installation manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals