SICK MLG10S-0290D10501 Measuring Automation Light Grids Owner’s Manual

September 2, 2024
SICK

SICK MLG10S-0290D10501 Measuring Automation Light Grids

Specifications:

  • Device Version: Prime – Standard functionality
  • Sensor Principle: Sender/receiver
  • Minimum Detectable Object (MDO): 14 mm
  • Beam Separation: 10 mm
  • Type of Synchronization: Optical
  • Number of Beams: 30
  • Detection Height: 290 mm
  • Operating Mode: Standard
  • Function: Cross beam, Beam blanking
  • Applications: Switching output, Object detection

Product Usage Instructions

Installation:

  1. Choose a suitable mounting location ensuring proper alignment and height.
  2. Securely mount the automation light grids using appropriate fixtures.

Configuration:

  1. Connect the device to a power source within the specified voltage range.
  2. Adjust the beam separation and synchronization settings as needed for your application.

Operation:

  1. Power on the device and ensure proper functionality.
  2. Monitor the detection area for any objects and observe the switching output for responses.

FAQ:

  1. Q: What is the maximum range of the automation light grids?
    A: The maximum range is 7 meters, providing ample coverage for various applications.

  2. Q: Can the device be used in outdoor conditions?
    A: Operating in outdoor conditions is possible only with an external protection housing due to specific requirements.

Ordering information

Other models and accessories www.sick.com/MLG-2

Illustration may differ

Detailed technical data

Features

Device version Prime – Standard functionality
Sensor principle Sender/receiver
Minimum detectable object (MDO) 14 mm 1)
Beam separation 10 mm
Type of synchronization Optical
Number of beams 30
Detection height 290 mm
Software features (default)
Q1 Auto-define height classification
Q2 / IN Auto-define height classification
Q3 Auto-define height classification
inverted
Teach
key lock off
Operating mode
Standard
Function
Cross beam
Beam blanking
Applications
Switching output Object detection

1) Depending on beam separation without cross beam setting.

| | Object recognition
Height classification
---|---|---
| Data interface| Object detection
Object height measurement
Included with delivery| | 1 × sender
1 × receiver
4/6 x QuickFix brackets (6 x QuickFix brackets for monitoring heights above 2 m) 1 × Quick Start Guide

1) Depending on beam separation without cross beam setting.

Mechanics/electronics

Light source LED, Infrared light
Wave length 850 nm
Supply voltage V s DC 19.2 V… 28.8 V 1)
Power consumption sender 56.5 mA 2)
Power consumption receiver 126 mA 2)
Ripple < 5 Vpp
Output current I max. 100 mA
Output load, capacitive 100 nF
Output load, Inductive 1 H
Initialization time < 1 s
Switching output Push-pull: PNP/NPN
Connection type Male connector M12, 5-pin, 0.22 m
Male connector M12, 5-pin, 0.22 m
Housing material Aluminum
Indication LED
Enclosure rating IP65, IP67
3)
Circuit protection UV connections, reverse polarity protected
Output Q short-circuit protected
Interference pulse suppression
Protection class III
Weight 0.849 kg
Front screen PMMA
Option None
UL File No. NRKH.E181493
  1. Without load.
  2. Without load with 24 V.
  3. Operating in outdoor condition only with a external protection housing.

Performance

Maximum range 7 m 1)
Maximum range ≥ 0.2 m
Operating range 5 m
Response time 6.1 ms

1) No reserve for environmental issue and deterioration of the diode.

Communication interface

IO- Link ✔, IO-Link V1.1
Data transmission rate 38,4 kbit/s (COM2)
Maximum cable length 20 m
Cycle time 6 ms
VendorID 26
DeviceID HEX 800067
DeviceID DEC 8388711
Process data length 6 Byte (TYPE_2_V) 1)
Inputs/outputs 3 x Q (IO-Link)
Digital output Q1 … Q3
Number 3
Digital input In1
Number 1

1) With an IO-Link master with V1.0, fall back to interleaved mode (consisting of TYPE_1_1 (ProcessData) and TYPE_1_2 (On-request Data)).

Ambient data

  • Shock resistance Continuous shocks 10 g, 16 ms, 1000 shocks Single shocks 15 g, 11 ms 3 per axle
  • Vibration resistance Sinusoidal oscillation 10-150 Hz 5 g
  • EMC EN 60947-5-2
  • Ambient light immunity Direct: 12,000 lx 1) Indirect: 50,000 lx 2)
  • Ambient operating temperature –30 °C … +55 °C
  • Ambient temperature, storage –40 °C … +70 °C
  1.  Outdoor mode.
  2.  Light resistance indirect.

Smart Task

  • Smart Task name Base logics

Classifications

  • ECLASS 5.0 27270910
  • ECLASS 5.1.4 27270910
  • ECLASS 6.0 27270910
  • ECLASS 6.2 27270910
  • ECLASS 7.0 27270910
  • ECLASS 8.0 27270910
  • ECLASS 8.1 27270910
  • ECLASS 9.0 27270910
  • ECLASS 10.0 27270910
  • ECLASS 11.0 27270910
  • ECLASS 12.0 27270910
  • ETIM 5.0 EC002549
  • ETIM 6.0 EC002549
  • ETIM 7.0 EC002549
  • ETIM 8.0 EC002549
  • UNSPSC 16.0901 39121528

Dimensional drawing (Dimensions in mm (inch))

Dimensional drawing

  1. Distance: MLG edge – first beam
  2. MLG20x-xx40: 68.3 mm
    MLG20x-xx80: 78.3 mm
  1. First beam
  2. Last beam
  3. Detection height (see technical data)
  4. Beam separation
  5. Optical axis
  6. Status indicator: green, yellow, red LEDs
  7. Connection

Adjustments

Adjustments

  1. MLG-2 with switching outputs Q
  2. MLG-2 with analog outputs QA
  3. Status indicator: green, yellow, red LEDs

Connection type and diagram

Connector M12, 5-pin, switching outputs Q

  1. Not assigned

Recommended accessories

Other models and accessories www.sick.com/MLG-2

Brief description Type Part no.

Plug connectors and cables
|

  • Connection type head A: Female connector, M12, 5-pin, straight, A-coded
  • Connection type head B: Flying leads
  • Signal type: Sensor/actuator cable
  • Cable: 5 m, 5-wire, PVC
  • Description: Sensor/actuator cable, unshielded
  • Application: Zones with chemicals

| YF2A15- 050VB5XLEAX| 2096240
Sensor Integration Gateway

|

  • Further functions: Web server integrated, USB connection for easy configuration of the SIG200 Sensor Integration Gateway with SOPAS ET, the engineering tool from SICK, logic editor is available for easy configuration of logic functions
  • Connection CONFIG: 1 x M8, 4-pin female connector, USB 2.0 (USB-A)
  • Logic editor: yes
  • Communication interface: IO-Link, USB, Ethernet, PROFINET, REST API
  • Product category: IO-Link Master

| SIG200-0A0412200| 1089794

  • Further functions: Web server integrated, USB connection for easy configuration of the SIG200 Sensor Integration Gateway with SOPAS ET, the engineering tool from SICK, logic editor is available for easy configuration of logic functions
  • Connection CONFIG: 1 x M8, 4-pin female connector, USB 2.0 (USB-A)
  • Logic editor: yes
  • Communication interface: IO-Link, USB, Ethernet, REST API
  • Product category: IO-Link Master

| SIG200-0A0G12200| 1102605

SICK AT A GLANCE
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”

WORLDWIDE PRESENCE:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals