Specifications
- Product Model: Coreline Panel G6
- Power Supply: indoor 220V 50Hz
- Lifetime: Up to 100,000 hours at L80
- Lumen Output: 2900 – 4300 lm
- Color Rendering Index (CRI): 80
- Dimensions (L x W x H): 595 x 595 x 73 mm
- Weight: 2.5 Kg
- IP Rating: IP20
Product Usage Instructions
Installation
- Ensure the power supply matches the required specifications.
- Mount the Coraline Panel G6 securely in the desired location.
- Connect the wiring according to the provided instructions.
Powering On/Off
- To power on the Coraline Panel G6, switch on the main power source.
- To power off, switch off the main power source.
Maintenance
- Regularly clean the panel using a soft, dry cloth.
- Avoid using harsh chemicals that may damage the surface.
FAQ
- Q: What should I do if the luminaire’s external cable is damaged?
- A: If the external cable is damaged, it must be replaced with a special cord available from the manufacturer or authorized service agent.
- Q: How do I know when to replace the battery in the emergency luminaire?
- A: The indicator LED will provide a signal when the battery needs replacement.
What In The Box
Features
Product info label
Lifetime table
Lumen| CRI| 50k hrs| 100k hrs
2900 – 4300 lm| 80| L90| L80
| Lumen (lm)| CCT (K)| P(W)| L x W x H (mm)| H1/H2| Weight (Kg)| IP| IK| The
energy efficacy class of the light source
---|---|---|---|---|---|---|---|---|---
RC132V G6 43S/840 SIA W60L60 OC IA4| 4300| 4000| 32| 595 x 595 x 73| 37/11|
2.5| IP20| IK02| C
RC132V G6 40S/830 SIA W60L60 OC IA4| 4000| 3000| 32| 595 x 595 x 73| 37/11|
2.5| IP20| IK02| C
RC133V G6 36S/840 PSED W62L62 OC| 3600| 4000| 28| 620 x 620 x 73| 37/11| 2.5|
IP40/IP20| IK03| C
RC132V G6 36S/840 PSU W60L60 OC ELB3| 3600| 4000| 28| 595 x 595 x 69| 37/11|
3.2| IP44/IP20| IK03| C
RC132V G6 36S/840 PSD W60L60 OC ELB3| 3600| 4000| 28| 595 x 595 x 69| 37/11|
3.2| IP44/IP20| IK03| C
RC132V G6 36S/840 WIA W60L60 OC ELB3| 3600| 4000| 28| 595 x 595 x 69| 37/11|
3.2| IP44/IP20| IK03| C
RC132V G6 36S/840 PSU W30L120 OC ELB3| 3600| 4000| 28| 1195 x 295 x 69| 37/11|
3.2| IP44/IP20| IK03| C
RC132VG6 29_36_43/830_40 PSU 60x60OC CCE
| 2900/ *3600
/4300
| 3000/ *4000*| 23.2/ 26.5**
/31.8
|
595 x 595 x 69
|
37/11
|
2.3
|
IP44/IP20
|
IK02
|
C
RC132VG6_29_36_43/830_40 PSU 30x120OCCCE
| 2900/ *3600
/4300
| 3000/ *4000*| 23.2/ 26.5**
/31.8
|
1195 x 295 x 69
|
37/11
|
2.4
|
IP44/IP20
|
IK02
|
C
RC132VG6 29_36_43/830_40 PSU 60x60OC WA3
| 2900/ *3600
/4300
| 3000/ *4000*| 23.2/ 26.5**
/31.8
|
595 x 595 x 69
|
37/11
|
2.5
|
IP44/IP20
|
IK02
|
C
RC132V G6 40_43S/830_40 PSD 60×60 OC WA5| 4000/ *4300*| 3000/ 4000**| 32| 595 x 595 x 69| 37/11| 2.6| IP44/IP20| IK02| C
RC132VG6_29_36_43/830_40 PSU 30x120OCWA3
| 2900/ *3600
/4300
|
3000/ *4000
| 23.2/ *26.5
/31.8
|
1195 x 295 x 69
|
37/11
|
2.7
|
IP44/IP20
|
IK02
|
C
RC132V G6 40_43S/830_40 PSD 30×120 OCWA5| 4000/ *4300*| 3000/ 4000|
32| 1195 x 295 x 69| 37/11| 2.8| IP44/IP20| IK02| C
RC132V G6 40_43S/830_40 WIA 60×60 OC CCE| 4000/ 4300| 3000/ 4000|
32| 595 x 595 x 69| 37/11| 2.4| IP44/IP20| IK02| C
RC132V G6 40_43S/830_40 WIA 60×60 OC WA3| 4000/ 4300| 3000/ 4000**|
32| 595 x 595 x 69| 37/11| 2.4| IP44/IP20| IK02| C
RC132V G6 40_43S/830_40 WIA 30×120 OCWA3
| 4000/ *4300*| 3000/ 4000**| 32|
1195 x 295 x 69
|
37/11
|
2.3
|
IP44/IP20
|
IK02
|
C
*Default settings
Dimension
Quick connectors
Installation Instructions
Versions with WAGO connector (WA3, WA5)
PSED version
SIA version
CCE version
- If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent
VPC – Visible Profile Ceiling/ Lay-in mounting
Safety cable
Multi Lumen / Multi color
Battery replacement
Indicator LED
Emergency Luminaire
- In case a self-contained emergency driver has been added, this is how to set the timers (IEC62034 (§6.3.2)):
- BASIC version: No timers available, only manual testing through the test button.
Polar diagrams for ELB3 versions
Polar diagram for PSED version
Charge time
Lifetime
- The batteries have a lifetime expectancy of 4 years when maintained properly. Replace after that time!
- Automatic emergency time selection
- After installation and power up the driver will detect the battery and start the automatic detection process.
- During automatic detection, the indicator LED will light up with short green flashes.
- Between a minimum 6 and a maximum 30 seconds, the TrustSight driver will set the battery type (number of ce and will set the emergency output power accordingly.
- After that, the system is defined and fully operational. The battery type definition has an influence on the performance during the self-test and on the battery charge method. When the automatic battery detection process is disrupted, e.g. by switching off the permanent mains, the detection process is stopped and the TrustSight emergency driver will go into emergency mode with the lowest output power. At the next power-up, the automatic detection process will start again.
Periodic testing
Periodic tests of emergency lighting luminaires must be performed according to
EN50172 clauses 7.2.3 and 72.4.
Switch on in the emergency mode each month by simulation of a failure of the
supply to the normal lighting fire a period sufficient to ensure that each
lamp is illuminated. Twice per year, each luminaire shall be tested for its
full rated duration (at least 3hrs).
For more information please consult the TrustSight Gen 3 Design in guide. The
latest version is available online.
LED indicator status
The luminaire shall be installed by a qualified electrician and wired under the latest IEE electrical regulations or the national requirements.
- The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced – During the installation or maintaining the luminaire please use gloves to avoid spots on the cover.
- To remove dirt and spots use the following:
- Dust: use microfiber cloths only.
- Fingerprints, etc.: use cleaner for synthetic materials with antistatic properties.
- Luminaires were not suitable for covering with thermally insulating material.
- For controllable luminaires, the classification of the insulation between LV supply and control conductors shall be basic insulation at least.
- Luminaires must not be used or stored in corrosive environments where hazardous materials such as Sulphur, Chlorine, Phthalates, etc., are present.
Battery Unit (LFP)
Manufacturer:| Philips
Unit:| TrustSight 3.2V 3cell
4500mAh battery LFP+
Technology:| Lithium-Ion
Luminous flux:| 250 lm
Capacity:| 4500 mAh
Power:| 2W
Duration:| 3h
Nominal voltage:| 3.2V
| PSU| PSU (DIP
Switch)
| PSD (DIP
Switch)
| PSD| WIA| PSED/SIA
---|---|---|---|---|---|---
| Electrical characteristics
Imax(A)| 16| 20| 26| 20,4| 4,8| 20,4
Tref (us)| 200| 220| 260| 195| 56| 195
MCB| No. Of luminaires max.
B-10 A| 18| 13| 9| 16| 32| 16
B-16 A| 30| 21| 15| 24| 50| 24
C-10 A| 31| 21| 15| 25| 52| 25
C-16 A| 51| 37| 28| 41| 85| 41
Disconnect before servicing
- Luminaire has basic insulation between Low Voltage supply and control conductors.
- The control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. The light source contained in this luminaire is not replaceable, in case of damage replace the luminaire.
- Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to ensure maximum strength over lifetime.
- This product contains a light source of energy efficiency class: see table or label.
Zhaga-D4i and SR-certified compatibility
For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products / https://www.lighting.philips.co.uk /oem-emea/products/driving-connected-lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-D4i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non-compliance for which Signify cannot take any responsibility.
© 2023 Signify Holding
All rights reserved. This document contains information relating to the
product portfolio of Signify which information may be subject to change. No
representation or warranty as to the accuracy or completeness of the
information included herein is given and any liability for any action in
reliance thereon is disclaimed. The information presented in this document is
not intended as any commercial offer and does not form part of any quotation
or contract. Philips and the Philips Shield Emblem are registered trademarks
of Koninklijke Philips N.V… All other trademarks are owned by Signify Holding
or their respective owners.
Signify Holding
The Netherlands
References
- Sustainable LED lighting solutions | Philips lighting
- Sustainable LED lighting solutions | Philips lighting
- Sustainable LED lighting solutions | Philips lighting
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>