vanEE 41301 Fresh Air System Wall Control Owner’s Manual

August 31, 2024
vanEE

vanEE 41301 Fresh Air System Wall Control

Product Information

Specifications

  • Main Controls:
    • Model: ADVANCED TOUCHSCREEN (Part no. 41303)
    • Model: DEHUMIDISTAT (Part no. 41302)
    • Model: AUTOMATIC (Part no. 41304)

Product Usage Instructions

ADVANCED TOUCHSCREEN Wall Control

The ADVANCED TOUCHSCREEN wall control is designed for users who prefer advanced technology:

  • Features Virtuo Air TechnologyTM for intuitive, fully configurable modes.
  • Allows bidirectional communication for detailed maintenance information.
  • Easy programming of unit settings and simple pairing with auxiliary controls.
  • Schedules ventilation system operating modes for a week.
  • Offers CONT, INT, RECIRC, SCHEDULING, AWAY, and STB modes.

DEHUMIDISTAT Wall Control

The DEHUMIDISTAT wall control is perfect for managing humidity levels:

  • Features integrated humidity sensor for continuous comfort.
  • Indicates MIN and MAX speed continuous exchange ventilation.
  • Provides INT mode for specified time intervals.
  • Indicates filter maintenance and system error alerts.
  • Includes STB Standby mode.

AUTOMATIC Wall Control

The AUTOMATIC wall control simplifies user experience with basic features:

  • Operates according to outdoor temperature in AUTO mode.
  • Offers CONT, INT, RECIRC, TURBO modes.
  • Indicates filter maintenance and system error alerts.
  • Includes STB Standby mode.

Frequently Asked Questions (FAQ)

  • What are the main differences between the AUTOMATIC and SMART modes?
    AUTOMATIC MODE: Operates based on outdoor temperature.
    SMART MODE: Uses indoor humidity level and outdoor temperature for enhanced comfort.

Wall Controls

The vänEE wall controls line-up is modern, stylish and user-friendly. It has been designed to please both homeowners and installers. The line-up offers various controls that have been created to meet specific needs and different applications. This line-up is compatible exclusively with our products driven by Virtuo Air TechnologyTM.
From the basic wall control to the most advanced fresh air system wall control ever put on the market, there is a wall control to suit your needs.

Main Controls

ADVANCED TOUCHSCREEN

It is the most advanced wall control thanks to Virtuo Air TechnologyTM. It features intuitive, fully configurable modes via the touch screen. It is the perfect wall control for those who love technology. It offers bidirectional communication between the unit and the wall control to get detailed maintenance information. All unit settings are easy to program. The pairing with auxiliary control(s) is simple. The installer can also save a program to reuse it for a similar dwelling. SMART: The system will operate according to outdoor temperature and indoor temperature/humidity.
CONT: MIN, MED or MAX speed continuous exchange ventilation.
INT: Alternate between continuous exchange mode and standby or recirculation (if available) modes as per selected configuration. Speed and time are adjustable.
RECIRC (if available): Recirculate air inside the house at the selected speed.
TURBO: 4-hour MAX speed exchange ventilation then comes back to its previous mode.
DEHUM/HUMIDISTAT: The wall control includes a programmable dehumidistat/humidistat. The dehumidistat will deactive if outside temperature exceeds 24°C (75°F).
SCHEDULING: It is possible to schedule the ventilation system operating modes for a week.
The indicator lights up when filter maintenance is required and there is a detailed system error log for easier maintenance.
AWAY    When you are not home, the system provides minimum ventilation of your house.
STB          Standby mode
NOTE: The temperature displayed on ADVANCED TOUCHSCREEN wall control may vary by 5ºC (9ºF) (more or less) compared to the  outside temperature since the temperature sensor is located inside the unit to ensure a reading that optimizes Virtuo Air Tech-nologyTM algorithms.
PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

DEHUMIDISTAT

It is the perfect wall control to manage the humidity percentage in the house. It features an integrated humidity sensor to support the humidity level selected, which allows continuous comfort even in the changing seasons.

DEHUM: Select from 30% to 55% RH. If the set point is exceeded, the system will operate in MAX speed until the set point is reached. The dehumidistat will deactive if outside temperature exceeds 24°C (75°F).
CONT: MIN speed (light LED indicator) continuous exchange ventilation. MAX speed (dark LED indicator) continuous exchange ventilation.
INT: 20 min in MIN speed continuous exchange ventilation and 40 min in standby or recirculation (if available) modes as per selected configuration.
The indicator lights up when filter maintenance is required and the indicator flashes when a system error is detected.
STB      Standby mode

AUTOMATIC
It is designed to make customer’s life easier. All basic features as well as the most popular modes are included with this wall control.

AUTO: The system will operate according to outdoor temperature.
CONT: MIN, MED or MAX speed continuous exchange ventilation.
INT: 20 min in MIN speed continuous exchange ventilation and 40 min in standby or recirculation (if available) modes as per selected configuration.
RECIRC (if available): Recirculate air inside the house at MAX speed.
TURBO: 4-hour MAX speed exchange ventilation then comes back to its previous mode.
The indicator lights up when filter maintenance is required and the indicator flashes when a system error is detected.
Standby mode

Difference between Automatic Mode and Smart Mode

AUTOMATIC MODE SMART MODE

In AUTOMATIC mode, the system operates according to outdoor temperature. The system operates as follows:

  •  Less than -25°C = 10 min/hr
  • -25°C to -7°C = 20 min/hr
  • -7°C to 10°C = 40 min/hr
  • 10°C to 25°C = MIN speed
  • 25°C to 28°C = 30 min/hr
  • 28°C to 33°C = 20 min/hr
  • Above 33°C = 10 min/hr

| The SMART mode uses indoor relative humidity level and outdoor temperature to manage the air exchange with the outdoors, in order  to enhance comfort in the house. See  graph  below.



Auxiliary Controls

For installation in a bathroom, a laundry room or a workshop. This wall control can be installed with any of the main controls listed above and is compatible with previous series.
CONT: MAX speed exchange ventilation for 20, 40 or 60 minutes.
20-40-60 DELUXE

It is designed to make installers and customers life easier with its wireless and automatic RH detection. For installation in a bathroom, a laundry room or a workshop. Bluetooth® wireless pairing with the ADVANCED TOUCHSCREEN main control (part no. 41303).

CONT: MAX speed exchange ventilation for 20, 40 or 60 minutes.
Integrated sensor detects humidity rise and sets MAX speed for 20 minutes or as per  selected   configuration.
Wireless pairing with the ADVANCED TOUCHSCREEN main control.
Low batteries indicator – requires 2 AAA 1.5 V batteries.
“The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Venmar Ventilation ULC is under license. Other trademarks and trade names are those of their respective owners.”
Venmar Ventilation ULC, 550, Lemire Blvd, Drummondville (Quebec) 1-800-567-3855 www.broan- nutone.ca

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals