Feyree TS-NACS 7KW EV Charger Station User Manual

August 30, 2024
feyree

TS-NACS 7KW EV Charger Station

EV Charging Station
Manual

It is recommended to read the instructions before use

Safety instructions

Warning: The charging station must be grounded (PE) in order to use t properly Warning: Do not place flammable, explosive or combustible materials, chemicals, combustible vapors or other hazardous materials near the charging station.
Warning: Keep the charging plug head clean and dry, if dirty, please wipe it with a clean and dry cloth, it is strictly forbidden to touch the charging plug core by hand when it s charged
Warning: t s strictly forbidden to use the charging station when the charging plug or charging cable s defective, cracked, worn, broken or when the charging cable is exposed
Warning: Do not attempt to disassemble, repair or modify the charging station. If you need to repair or modify t, please contact the relevant staff. mproper operation may cause the charging station damage, water eakage, leakage of electricity, short circuit, electric shock and other risks
Warning: Use with caution during thunderstorms
Warning: Children should not approach or use the charging station during the charging process to avoid electric shock
Warning: Do not drive the car while t s charging. You can only start charging
When the car is stationary. For hybrid Cars, please turn off the engine before charging
Warning: n case of emergency during the operation of the product, press the emergency stop button mmediately to cut off all input and output power
Warning: The use of the charging post s prohibited n the following cases and the manufacturer should be contacted mmediately:

  • Charging Station shell is broken
  • When the charging cable on the charging station is damaged, cracked, frayed, broken, etc.
  • Lightning strikes charging station
  • Accidents or fires near charging stations
  • Water in the charging station
  • The ength of the charging cable on charging station is not ong enough to connect to the car, an extension cable needs to be installed

Product Overview

Brief description:
This product is used for electric vehicle AC charging, the product design is highly simple, divided into Type2, Type1, GB/T, Tesla four kinds of specifications. It is equipped with swipe card and plug-and-play charging methods and multiple safety protection functions. with good dustproof and waterproof function, can be operated safely outdoor. Type 2 Parameter introduction

Type2 IEC61851

Power Rating| 7.6KW| 11KW| 22KW
Load balancing| /| | /| | /| |
APP| /| | /| | /| |
RFID Card| /| | /| | /| |
Type A RCD| | | /| /| /| /| /| | /
Type B RCD| /| | /| | | /| | /| | •| /| | /| |
Power supply
system| Single Phase| Three
Phase| Three
Phase
Rated voltage| 85V-264V| 380V±20%| 380V±20%
Rated current| 8-10-13-16-20-25-32A| 8-10-13-16A| 8-10-13-16-20-25-32A
Input Frequency| 50Hz/60Hz| 50Hz/60Hz| 50Hz/60Hz
Protection level| IP65| IP65| IP65
Working
temperature| -35°C — +55°C| -35°C — +55°C| -35°C — +55°C
Storage
temperature| -40°C — +80°C| -40°C — +80°C| -40°C — +80°C
Standby power| <3W| <3W| <3W
Working humidity| 5% – 95%
non-condensation| 5% – 95%
non-condensation| 5% – 95%
non-condensation
LWH| 31016186 mm| 31016186 mm| 31016186 mm
ISpecification| 3G 6gmm,² ++10.5mm²
3G 6mm² +2
0.5mm ²| 5Gmm²+10.5mm²
5G 2.5mm²+ 2
0.5mm²| 5G 6mm²+10.5mm²
5G 6mm² + 2
0.5mm²

Control box function :

  1. Earth leakage protection (restart recovery)
  2. 0vervoltage and undervoltage protection (self-test recovery)
  3. Lightning protection
  4. 0vercurrent protection
  5. 0verheat protection
  6. Grounding protection
  7. RFI D card function (can be set according to user needs)
  8. Appointment Time
  9. WIFI

Product Performance:

  1. Charging plug according to IEC 62196-2 standard
  2. Charging control box in accordance with IEC 61851 control principle
  3. lnsulation resistance: >10000
  4. Terminal temperature rise: <SOK
  5. Mechanical life: Charging Plug plugging and unplugging times (Non operating state)>10000 times
  6. External impact: Charging staion’s Plug can withstand the 1-meter drop and 2 tons of vehicle crushing
  7. With emergency stop function

Type 1 Parameter introduction

Type 1 SAE J 1772

Power Rating| 7.6KW| | | | 12KW| |
Load balancing| | | | | | | | |
APP| | | | | | | | |
RFID Card| ‘| | | | | | | | | |
Type A RCD| | | | | | | | | | | | | |
Type B RCD| | | | | | | | | | | | | |
Power supply
system| Level 1 and Level 2| Level 1 and Level 2| Level 1 and Level 2
Rated voltage| 85V-264V| 85V-264V| 85V-264V
Rated current| 8-10-13-16-20-25-32A| 8-10-13-16-20-25-32-40A| 8-10-13-16-20-25-32-40-50A
Input Frequency| 50Hz/60Hz| 50Hz/60Hz| 50Hz/60Hz
Protection level| IP66| IP66| IP66
Working
temperature| -35°C — +55°C| -35°C — +55°C| -35°C — +55°C
Storage
temperature| -40°C – +80°C| -40°C – +80°C| -40°C – +80°C
Standby power| <3W| <3W| <3W
Working humidity| 5% – 95%
non-condensation| 5% – 95%
non-condensation| 5% – 95%
non-condensation
LWH| 31016186mm| 31016186mm| 31016186mm
Cable
Specification| 3G 6mm2+10.5mm2 3G 6mm2+20.5mm2 3G10AWG+118AWG
301 OAWG+2
1 flAWG| 3G 8mm2+ 10.5mm2
3G 8mm2+2
0.6mm2
2G8AWG+110AWG+118AWG
2G8AWG+1.10AWG+2.18AWG| 3G 10mm2+10.5mm2
3G 10mm2+2
0.5mm2
2G6AWG+1’8AWG+1-18AWG
2G6AWG+1’8AWG+21-18AWG