EMPV-54WIT08 Aromatherapy Electric Wall Ovens
“`html
Product Information
Specifications
- Product Model: EMPV-54WIT08
- Size: 54.33 x 30.31 x 39.76 inches
Product Usage Instructions
1. Instruction before Installation
Warning: When using this tub, follow basic
precautions:
-
Connect only to a circuit protected by a ground-fault circuit
interrupter (GFCI). -
All electrical connections should be made by a licensed
electrician. -
Comply with all state and local building codes when installing
the unit.
2. Preparing Tools before Installation
- Impact drill
- Spirit level
- Adjustable wrench
- 19mm Sleeve
- 5mm hexagonal key
- 10*100mm expansion bolts
- Waste bunker
- Expansion tube
- Tape rule
- Phillips screwdriver
- Glass Glue & Rob
- Art knife
- A hand saw
- Stainless steel screws
3. Size Chart
The product size is 54.33 x 30.31 x 39.76 inches.
4. Bathtub Plumbing Locator Diagram
Ensure proper positioning of the adjustable foot pads, drain
body, and hard drain pipe as shown in the diagram.
5. Installation Procedures
Follow the detailed installation procedures provided in the user
manual for proper setup of the walk-in tub.
6. Operational Use
Operate the walk-in tub according to the instructions provided
to enjoy a comfortable and safe bathing experience.
7. Care and Maintenance
Refer to the care and maintenance section in the user manual to
keep your walk-in tub in optimal condition.
8. Troubleshooting Guide
If you encounter any issues with the walk-in tub, refer to the
troubleshooting guide for solutions.
Frequently Asked Questions (FAQ)
Q: What should I do if I notice water leaks from the tub?
A: If you notice water leaks, check the connections and seals.
Tighten any loose connections or replace damaged seals as
needed.
Q: Can I install the walk-in tub myself?
A: It is recommended to have the walk-in tub installed by a
professional to ensure proper setup and compliance with safety
regulations.
“`
EMPV-54WIT08
TABLE OF CONTENTS
Instruction before installation
01
Preparing tools before installation
02
Size chart
03
Bathtub Plumbing Locator Diagram
04
Installation procedures
05
Operational use
08
Care and Maintenance
10
Troubleshooting Guide
10
Instruction before installation
WARNING : when usingthis tub,the following basic procautions should be
followed:
Avoid the risk of electrical shock Connect only to a circuit protected by a
grount-fault circuitinnterrupter(GFCI).Grounding is required; All electrical
connections should be made by a licensed electrician,in accordance with
requirements of national electrical codes and procedures.
Installer/owenr bears all responsibilty to comply with all state and local
building codes when installing this unit
Testing your walk-in tub before installation by following procedures
1.Before unpack the unit,please inspect the carton carefully for any
damage.any damage, please take a picture or record all admage carefully.if
necessary,contact your dealer/ distributor immediately. to file a freight
claim.
2.Unpack the carton,then inspect thr carton carefully for any damage and check
if all the spare parts are there. if there is any damage,please take a picture
or record all it carefully. if necessary,contact your dealer/distributor
immediately.
3.Water test before installation .although all our walk-in tub are water
tested before they leave our factory,there may be some loose of the hose
connections due to the transport. (1) Place the tub on a flat surface in an
area where it may be drained after testing. (2) Check if there is any loose of
the connection system. (3) Close the door,fill the tub with water to the
overflow and allow standing for a few minutes
to inspect the tub for leaks.
IMPORTANT : Failure to follow the pre-installation instruction and water test
the bathtub before installation, manufacturer will not be liable for the
removal or installation of the bathtub.
1
Preparing tools before installation
Impact drill
Spirit level
Adjustable wrench
19mm Sleeve
5mm hexagonal key 10*100mm expansion bolts
Waste bunker
Expansion tube
Tape rule
Phillips screwdriver Glass Glue & Rob
Art knife
A hand saw
Stainless steel screws
2
Size chart
PRODUCT
size
54.33″x30.31″x39.76″
17.72″
54.33″
Shower Head
15.02″
30.31″
Head Restraint
21.63″
15.72″
Drainer
Switch Drainer
19.27″
Water Line
19.25″
45.48″ 39.76″
14.91″ 23.89″
41.93″ 7.97″
3
Bathtub Plumbing Locator Diagram
Five-hole socket (with a
separate circuit for grounding, 10A current)
Flirnoenot fotuhteerbeadthgteub
Reserved Bathtub Drain Outlet ø50-ø100
Be sure to avoid the positions of the adjustable foot pads, the drain body,
and the hard drain pipe.
Flexible Drain Hose
Hot water Bathtub position
Rigid Drain Pipe
Cold water
lRinigehotfotuhteerbaetdhgtueb
Drain Body Housing
Legend in Range of Values the Diagram
Bathtub Adjustment Foot Position Bathtub Adjustment Foot Position
Within the Range of 200-500mm from the Bathtub Surface Space Below the Bathtub
Surface Within the Range of 200-500mm from the Bathtub Surface Height from
Ground: 600-800mm
Five-hole socket (with a
separate circuit for grounding, 10A current)
Bathtub Installation Plumbing and Electrical Schematic 1
Reserved Bathtub Drain Outlet ø50-ø100
Be sure to avoid the positions of the adjustable foot pads, the drain body,
and the hard drain pipe.
Drain Body Housing
lFinreonotfothuetebr aetdhgtueb
Hot water Bathtub position
Cold water lRinigehotfotuhteerbaetdhgtueb
Flexible Drain Hose
Rigid Drain Pipe
Bathtub Installation Plumbing and Electrical Schematic 2
4
Installation procedures
Installation Step 1:
Connecting Bathtub Water Supply and Drainage Pipes (Faucet Assembly)
The bathtub’s water supply pipes consist of cold water inlet and hot water inlet pipes. As shown in the diagram, connect the cold water pipe and the hot water pipe to the corresponding fittings reserved at the blade corners.
Manual
1aHydraulic Flow Regulator
2aHandheld Showerhead (with Detachable Hose)
3aHot Water Inlet Valve
4aShowerhead/Waterfall Control Valve
Hot water Cold water
As shown in the diagram right
Installation Step 2:
Installation of the Showerhead
1 Start by installing the showerhead base. 2 Install the showerhead. 3Unscrew
the hexagonal nut at the other end of the shower hose 4Thread the shower hose
through the showerhead base. 5Reattach the hexagonal nut, then connect it to
the shower control knob.
As shown in the diagram below
Bathtub surface
Connect the shower control knob
5
Installation Step 3:
Installation of the U-shaped Handrail
U-shaped Handrail
Accessories List: Stainless Steel Decorative Cover × (2) Bolts × (2) Rubber
Washers × (2) Metal Washers × (2)
Installation Step 4:
Installation of the Backrest
U-shaped Handrail
Stainless Steel Decorative Cover Rubber Washers Bathtub Surface Rubber Washers
Metal Washers
Bolts
Bracket Central Axis
Decorative Cover
Bracket Legs Backrest Bracket Spindle Bathtub Surface Bolts
Accessories List: Decorative Cover × (2)Bolts × (2)
Installation Step 5:
Leveling the Bathtub
1aUse a wrench to loosen the nut on the upper part of the footpad.
2aTwist the adjustable feet at the four corners of the bathtub until the level
of the cylinder surface.
3aTighten the adjusted nut with a wrench.
Spirit level Adjustable feet
Note:
If the bathtub is not leveled, the cylinder may be twisted and deformed,
resulting in water leakage. After adjusting the level of the bathtub, check
whether the upper doorway is too narrow or too wide, and if so, adjust it
according to step 6
6
Installation Step 6:
Adjust the size of the door gap
1aWhen the doorway is small up and big down, adjust the adjusting foot under
the door downward. 2aWhen the doorway is large and small, adjust the
adjustable feet under the door upward
Installation Step 7:
Door Handle Installation
The door handle must be installed correctly in its position in order to avoid damage to the
internal mechanisms of the door.
1: Align the positioning point of the handle with the slot of the door handle hole and insert it
3: The M12 threaded rod is inside the central threaded hole
5: Tighten the exterior decorative cover
2: Press down with your hand completely; it should not be suspended.
4: Use a socket wrench to tighten
6: Installation completed
1aDiagram illustrating the range of handle rotation
2aEnlarge the diagram showing the installation
180°
positioning point of the handle
Installation step 8:
How to connect water ?
For ease of use, our bathtub is equipped withstainless steel cold and hot
water hoses (connector 3/4″). Please connect the cold and hot water hoses
tothe bathroom’s cold and hot water hoses accordingly
Notice
The red hose stands for hot water hose;the blue hose stands for cold water hose; Drain-pipe should be installed with slope above 1:50; Do not hold the drain-pipe and cold/hot water hoses when moving the bathtub, and do not crash it with hard objects.
How to connect the clectricity ?
Users need to prepare the power supply for 110-120V plugs install the proper
dedicated plug with a ground electrode tothe
power line,Then insert the plug frmly.
Notice
The product should be installedalongside ground and electric leakageswitches by a licensed electrician.
Make sure the ground is connected. One side of the ground should be connected to the ground terminal of the motor and the stainless steel frame; the other side should be connected to the ground wires of the plug
From electrical source 110-120W
Notice
The bathtub must be connected to the ground. The power outlet must be sealed well.Make sure the surface of each wire is in tact.
7
Installation completed
To ensure the stability and prolong the lifespan of the bathtub, apply
silicone sealant at the points where the bathtub walls make contact. This
helps keep the bottom of the bathtub dry, thus extending its lifespan (as
shown in the diagram below).
Note:
After installation is complete, please conduct an electricity and water test
to ensure that all systems are functioning properly.
Operational use
Overview of the Main System Panel
Figure 1: Panel Structure Diagram
Total Open/Key
Wall tiles Silicone sealant Bathtub body
Wind Pump On/Key
Water Pump On/Key
Temperature Setting Key
Function Brief
1aTotal On/Off Function Mode: Power On Mode and Standby Mod 2aMaximum 3KW
Constant Temperature Heating Function, Water Temperature Display
and Setting Function 3a1 Water Pump 4a1 Wind Pump 5aThe DIP switch can select
different functions. 6aError Code Indication
Operation of Common Functions
(1) Main Board Description and DIP Jumper Settings (see Figure 6)
A1: OFF: Display Fahrenheit Temperature ON: Display Celsius Temperature
A2: OFF: With Water Level Sensor ON: Without Water Level Sensor
A3: OFF: Water Flow Sensor, Heater Does Not Operate When No Water Flow is
Detected ON: Without Water Flow Sensor
A4: Figure 6: Switchbank A/B
8
Attention:
1aAll jumper settings are only effective when power is cycled. The power-off
interval should be greater than 60 seconds.
2aAll jumpers have been set at the factory. It is recommended that users do
not change the product settings.
(2) When first powered on, the display shows “- – -“, indicating that the
system is in standby mode (see Figure 12)
Figure 12: Standby Mode
Figure 13: Power On Mode
(3) Operation for Powering On/Off
In standby mode (see Figure 12), press the ” off state. In power on mode (see Figure 13), press the ” are turned off.
” keyThe “—” disappears, and all loads are in the ” key, “—” appears, and all high-voltage loads
(4) Function Operations in Power On Mode
Operation of the Surf Water Pump The ” ” key controls the on/off state of the
surf water pump. The surf water pump will automatically turn off after 1 hour.
Note: The surf water pump will not start if the water level sensor detects no
water. Operation of the ” ” Key. The ” ” key controls the on/off state of the
wind pump. The wind pump will automatically turn off after 15 minutes.
Temperature Control (77-104°F/25-40°C) Press the ” ” key for the first time to
enter the temperature setting mode. The set temperature will flash on the
screen. Before the temperature stops flashing, each press of the ” ” key
increases the set temperature by 1°C. Holding down the ” ” key continuously
increases the set temperature until it reaches the maximum setting of 40°C
(104°F). Pressing the ” ” key once more resets the set temperature to the
minimum setting of 25°C (77°F). Heating Function Description When the
temperature is in Celsius, the temperature control range is -1°C. This means
that when the set temperature TsetT{set}Tset is 30°C, the heater will turn
off when the water temperature reaches 30°C. The heater will restart when the
water temperature drops to 29°C or below. When the temperature is in
Fahrenheit, the temperature control range is -2°F. This means that when the
set temperature TsetT{set}Tset is 90°F, the heater will turn off when the
water temperature reaches 90°F. The heater will restart when the water
temperature drops to 88°F or below.
Note:
The heating function automatically starts when the water pump is turned on;
the heating function automatically stops when the water pump is turned off.
9
Warnings and Error Indications
1.For equipment used in multi-family residences, a clearly labeled emergency
switch must be provided during installation. The user should have unobstructed
access to this switch, and it must be installed at least 1.52 meters away,
near the equipment and within the user’s line of sight. 2.If any wiring is
damaged, it must be replaced immediately. 3.Power must be turned off before
repairing or replacing any wiring connected to the equipment. 4.To prevent the
risk of electric shock and/or water damage to the controller, all unused wire
lead outlets must be sealed with plugs. 5.This controller must not be
installed near highly flammable substances. 6.Do not enter the water when any
error indications are present!
Care and Maintenance
Walk-in bathtubs require regular maintenance to keep them clean and in top
working condition. After using the old man’s tank, wash it with water and dry
it with a clean rag.
Troubleshooting Guide
SYMPTOMS Door leaks slightly Water hose leaks
PROBLEMS
1.Door lock is not closed tightly; 2.There is some debris on the door seal.
1.Rubber ring is not good; 2.Screw nut is not tightened, the connection
is not good.
SOLUTIONS
1.Close the door lock tightly; 2.Clean the debris on door seal. 1.Change a new
rubber ring; 2.Tighten screw nut and make sure its
connection is good.
EMPAVA APPLIANCES INC. 15253 DON JULIAN RD CITY OF INDUSTRY,CA 91745