TRACTIAN SR-PRO Smart Receiver Pro Instruction Manual

August 20, 2024
TRACTIAN

TRACTIAN SR-PRO Smart Receiver Pro

About your Smart Trac Receiver Pro

TRACTIAN System

  • By monitoring assets online and in real-time, the TRACTIAN system guarantees solutions to optimize daily maintenance management.
  • The system integrates vibration and temperature sensors with mathematical models, generating alerts that avoid unwanted shutdowns and high costs resulting from unexpected failures.
  • Fault detection

TRACTIAN’s

  • unique analysis system enables accurate fault detection. The algorithms are constantly trained based on feedback from field analysis, always under the supervision of our vibration specialists. Thousands of spectra are
  • collected daily in a system that pinpoints asset failures before they happen.

Real-time data

  • Collections and analyses are displayed intuitively on TRACTIAN’s online platform, which is easily accessible from a computer or cell phone, enabling integrations with other systems.
  • The platform also allows for complete main-tenance control with hour meters, energy con-sumption, and automatic calculation of asset indicators.

Smart Receiver Pro

  • The Smart Receiver Pro is a transmitter responsible for receiving sensor data and sending it to TRACTIAN’s platform. The data is sent via the 2G, 3G and 4G/LTE mobile network via the best available operator in the region, selected
  • automati-cally. If necessary, data can be sent via a Wi-Fi network.

Installation

  • Smart Receiver Pro supports up to 100 sensors within a radius of 100 meters (330 feet) with obstacles and 1 kilometer (0.62 mile) in the open field, depending on the topography of the plant.
  • To install more sensors or cover greater distances, more receivers are required. It is recommended to position the receiver in an elevated location, centered in relation to the sensors.
  • DO NOT place the device on surfaces that reach a temperature above 230°F.
  • DO NOT clean the device with solvents such as Acetones, Hydrocarbons, Ethers, or Esters.
  • DO NOT subject the device to submersion.
  • DO NOT subject the device to excessive mechanical impact, dropping, crushing or friction.
  • TRACTIAN doesn’t take responsibility for damages caused by the use of devices outside the standards defined in this manual.

Activation

Before installing the devices, activate your access to the platform as follows:

TRACTIAN-SR-PRO-Smart-Receiver-Pro-FIG-6

app.tractian.com

Smart Receiver Ultra

TRACTIAN’s Smart Receiver Pro requires an external power supply. So make sure there are electrical connections near the installation site.

DO NOT set up the Smart Receiver Pro inside metal electrical panels, because these may block the receiver’s signal. As for other types of electrical panels, such as plastic ones, there is no risk to receivers.

TRACTIAN-SR-PRO-Smart-Receiver-Pro-FIG-7

Range & Reach
The receiver supports a maximum distance of 100 meters (330 feet) from the sensors with obstacles and 1 kilometer (0.62 mile) in the open field. It can communicate with up to 100 sensors, depending on the case. For this reason, to obtain the best results in places with a large number of assets, it is recommended to use more receivers in the same area.

Installation

  • This device must be professionally installed.
  • The number of receivers to be installed depends on the number of sensors installed and plant topology.
  • Only use the antenna that is provided with the device.
  • In an open field, it is necessary a direct view between the sensor and the receiver.
  • This device is designed and tested for industrial environments.

Installation Site

For best results, set up the receiver only in elevated places with the antenna in front of the sensors. Also note areas with no obstacles between the sensors and receiver.

TRACTIAN-SR-PRO-Smart-Receiver-Pro-FIG-8

  • Ideal
  • Not ideal, but acceptable
  • Inadequate position
  • Smart Trac Pro Sensor

Connection

TRACTIAN-SR-PRO-Smart-Receiver-Pro-FIG-14

Mobile Network

  • The Smart Receiver Pro connects automatically to the best available LTE/4G network in your region.

Wi-Fi

  • In case there is no mobile network available or you would rather connect it to a Wi-Fi network, the connection is possible. When plugged into the power outlet, the receiver will turn on a white light and generate its own network that
  • can be found in the Wi-Fi settings of nearby devices (such as smartphones or computers). By connecting your device to the receiver’s temporary network, you will see a form that must be filled out with your company’s Wi-Fi
  • information so the receiver can connect to it.

The receiver’s own network will be generated 10 seconds after it is plugged in. If no device connects within 1 minute, the receiver will search for the best available mobile network.

TRACTIAN-SR-PRO-Smart-Receiver-Pro-FIG-15

Technical Specifications

Smart Receiver Pro Technical Specifications

Connections

Physical input Physical output

| ****

Power supply and external antennas (Mobile and Wi-Fi) LED indicates operating status

---|---
Wireless Communication

Frequency Protocol Bands

Sensor connectivity

| ****

915 MHz ISM and 2.4GHz ISM

IEEE 802.15.4g and IEEE 802.11 b/g/n

2.4 GHz: 14 frequency channels, dynamically defined Up to 100 sensors within a 100m (330 feet) radius with obstacles or 1km (0.62 miles) in the open field

Host Network Commun.

Mobile

Mobile Frequencies



Wi-Fi Network

| ****

LTE (4G), WCDMA (3G) e GSM (2G)

LTE B1/B2/B3/B4/B5/B7/B8/B28/B66/B40 WCDMA B1/B2/B5/B8

GSM 850/900/1800/1900 MHz

802.11 b/g/n, 2.4 GHz, WPA2-Personal and WPA2- Enterprise

Wi-Fi Configuration

Wi-Fi network setup

| ****

Captive Portal through a smartphone or a computer

Physical Characteristics

Dimensions


Attachment Weight

External Material Building

| ****

86mm / 3.4in (W) x 61mm / 2.4in (H) x 35mm / 1.4in (D), excluding power supply and antennas

Attached by magnets

180g or 6.35oz, excluding power supply Makrolon 2407

Environmental Characteristics

Operation Temperature Humidity

Hazardous Area Rating

| ****

From –10°C to +60 °C (14°F to 140°F)

Maximum 95% of relative humidity Safe areas only.

For zone 2 (gas) and zone 22 (dust), ask our team of

experts for the Smart Receiver Ex.

---|---
Power Source

Power supply Input Power supply Output

| ****

127/220V, 50/60Hz

5V DC, 15W

Other

RTC (Real Time Clock) Receiver firmware update Sensor firmware update

| ****

Yes Yes

Yes, when associated with a receiver

Certification

FCC ID IC ID ANATEL IFT

| ****

2BCIS-SR-PRO

31644-SRPRO

06239-23-14488

TRTRSM23-29726

Antenna

Type Model/Manufacturer Peak Gain

| ****

Dipole antenna with SMA connector (50 ohm) ANT-LTE-WS-SMA/TE

4.1 dBi(698 to 803 MHz), 3.4dBi(791 to 960 Mhz),

5.0dBi(1553 to 1609 MHz),5.9 dBi(1710 to 2200 MHz),

3.1 dBi(2300 to 2400 MHz), 4.1(2496 to 2690 MHz)

FCC STATEMENT

Smart Receiver PRO Regulatory Compliance

FCC Class A Information
This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference
  2. This device must accept any interference received, including interference that may cause undesired operation

This equipment has been tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The radiated output power of this device meets the limits of FCC radio frequency exposure limits. This device should be operated with a minimum separation distance of 20 cm (8 inches) between the equipment and a person’s body.

ISED Certification
This device complies with ISED Canada’s license-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause interference; and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The radiated output power of this device meets the limits of ISED Canada radio frequency exposure limits. This device should be operated with a minimum separation distance of 30 cm between the equipment

2D  Drawing

TRACTIAN-SR-PRO-Smart-Receiver-Pro-FIG-16

CONTACT

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals