EWRF Technology US915 LoRaWAN RF Module User Manual

August 19, 2024
EWRF Technology

EWRF Technology US915 LoRaWAN RF Module

EWRF-Technology-US915-LoRaWAN-RF-Module-PRODUCT

Product Information

Specifications

  • Model: EWRF1022MLA LoRaWAN+wM-bus
  • Version: V1.0.1
  • Manufacturer: EWRF Technology, Co., LTD
  • Date: 2022.01.11
  • Frequency Range: 902-928 MHz
  • Protocols: LoRaWAN 1.0.3 Class A/C, Wireless M-bus T1/C1
  • Interface: UART
  • Data Encryption: AES 128
  • Compliance: CE RED/FCC 15.247

Product Usage Instructions

The EWRF1022MLA module integrates the LoRaWAN protocol stack (LoRaWAN Specification 1.0.3 Class A/C) and the wM-bus T1/C1 mode. It provides convenient and fast LoRaWAN network access and one-way data communication in wM-bus T1/C1 mode using a UART interface.

  • Ultra Low-power SoC chip ASR6601 embedded with one Sub 1G transceiver and one ARM STAR-MC1 MCU
  • Supports 902-928 MHz channels
  • Easy to use UART interface for communication and configuration
  • AT command support for communication and configuration
  • Data encryption using AES 128
  • Compliance with CE RED/FCC 15.247 requirements

Scope

  • This manual applies to firmware version LoRaWAN 1.0.3_wMbus 1.0.2-20220101 and later.

FAQ

  • Q: What are the supported protocols of the EWRF1022MLA module?
  • A: The module supports LoRaWAN 1.0.3 Class A/C and Wireless  M-bus T1/C1 protocols.
  • Q: How can I communicate with the module?
  • A: You can communicate with the module using the UART interface and AT commands for configuration and data exchange.
  • Q: What is the data encryption method used by the module?
  • A: The module uses AES 128 for data encryption.

Document History

Date Version Description/Changes
2022.01.11 V1.0 Initial version


2023.4.12

| ****


V1.0.1

| C1 of wM-busmodeadded Specification of module added Typical application circuit added

Fix some errors

 |  |

Introduction

EWRF1022MLA module integrates the LoRaWANprotocol stack (LoRaWAN Specification 1.0.3 Class A/C) and the wM-bus T1/C1 mode. The module uses the UART interface to exchange messages with the user’s equipment, providing convenient and fast LoRaWAN network access, and one-way data communication in wM-bus T1/C1 mode.

Feature

  • Ultra Low-power SoCchipASR6601 embeddedwithoneSub 1Gtransceiver and one ARM STAR-MC1 MCU, supporting 902-928 MHz channels
  • Embedded LoRaWAN (1.0.3) Class A/C and Wireless M-bus T1/C1 protocols
  • Easy to use UART interface for communication and configuration
  • AT command for communication and configuration
  • Data encryption AES 128
  • Conforms with CE RED/FCC 15.247 requirements

Scope
This manual applies to firmware version: LoRaWAN1.0.3_wMbus1.0.2-20220101 and later.

Working Mechanism

Modes
The module has two working modes: transparent transmission and command.

  1. The command mode uses AT commands to configure parameters, read status send data, etc.. In the command mode, when sending a parameter configuration or a status reading command, the user needs to wait for the module to return “OK” or “ERROR” before proceeding with the next command, otherwise the command may be invalid. When switching from transparent transmission mode to the command mode, the instruction (0x00 0x00 0x00) needs to be input and does not include the terminator “\r\n”.
  2. The transparent transmission mode is used to send and receive application data. In this mode, there are two kinds of communication, namely the LoRaWAN communication and the wM-bus communication. The LoRaWAN communication requires the module to join the network before it can access the LoRaWAN data services. The two communications can be switched from the AT command mode by inputting the “AT+SWTMD”.

Power-on/Resetinitialization
When the module is powered on/reset (hardware or software reset), it will be initialized. At this time, the module is in command mode, and the module can be operated through AT commands.

Parameters stored in non-volatile memory
If the user wants to store the parameters after power-off, the “AT+SAVE commands need to be executed to set the LoRaWAN orwM-bus parameters in the non-volatile memory. After the module is powered on/reset, the saved parameters will be read from the storage space. If the user doesn’t execute the “AT+SAVE” commands, the set parameters will be lost after power-off/ reset.

UART communication
The UART communication flow between the module and the user MCU includes three message types: command, response, and event. The command and response messages are used for parameter configuration and other operations, and the event messages are used for uplink/downlink data communication, as shown in Table 2-1.

Table 2-1 UART Communication Messages Type

Type Direction Function Description
command module<– user configuration The user’s MCU sends a command to the

module
response| module–> user| Module responses to the user MCU
event| Module <–>user| data communication| Asynchronous events that occur at any time: The user sends uplink data to the module;

The module sends downlink data to the user MCU;

The module sends the failure report, etc.

Specification

 | Parts No.

Items

|

EWRF 1022MLA

---|---|---

Electronics

| Operating voltage| 2.0-3.7v
TX current| <125 mA(@20dbm)
RX current| <10 mA
Sleep current| <1.5μ A
Operation current| < 20 μ A(@T1,30s TX period)

RF

| Frequency| US 902-928 Mhz(LoRaWAN)/868.95Mhz(T1,C1)
Modulation| LoRa/FSK
TX power| <21dBm

Data rate

| LoRaWAN:250-5470bps

T-mode: 100 kbps

C-mode: 100 kbps

RX sensitivity| -104 dBm(T/C-mode)
Ant.     impedance| 50 Ω

Security

| Data filter| CRC
Data encryption| AES 128

General

| Interface| Uart (TTL)
Uart Format| 8 N1 without parity
Uart baud| 9600bps
Operating temperature| -30℃ ~80℃
Operating humidity| 10~90% without condensation
Communication range| >200m(T1@868Mhz/14dbm/100Kbps,LOS)

Mechanics

EWRF-Technology-US915-LoRaWAN-RF-Module-FIG-1

Pin Description

  • Pin descriptions are shown in

Table 2-2: Table 2-2 Pin Descriptions of the Module

No. Pin I/0 Notes
1 VCC Power DC 2.0~3.7V
2 GND GND
3 TXD Output UART_TXD
4 CTS   UART_CTS(Reserved)
5 RXD Input UART_RXD
6 RTS   UART_ RTS(Reserved)
7 STAT Output Data communication status pin
8 BUSY Output Module idle indication pin
9 GND GND
10 RST Input Reset, active low
11 ANT   Antenna
12 GND GND

TypicalApplicationCircuit

EWRF-Technology-US915-LoRaWAN-RF-Module-FIG-2

Note: When using Transparent Transmission for data transmission and reception, it is recommended to connect the BUSY and STAT pins of the module to detect the status of the module. When using the AT+LSEND command to transmit and receive data in LoRaWAN, the BUSY and STAT pins fail and can be ignored.

Command Mode

The command mode is used for module parameter configuration, status reading, etc. Users can access the module by sending AT commands through the UART, to perform operations such as reading or writing configuration or query of status from registers. After the module is powered on/reset, it enters the command mode by default. In this case, the user can perform AT command operations directly. In command mode, the format of UARTport is fixed as: baud rate 9600bps, no parity, 8 bits data, 1 stop bit. The user sends an AT command to the module, the module parses the command, and returns a command response immediately, indicating the execution result of the command. If the module does not respond for a long time, it means the module status is abnormal.

AT Command Format
AT commands are used in uppercase ASCII format, starting with “AT” and ending with a carriage return and line feed (ie “\r\n”). The maximum length of the command string is 255 characters (including “\r\n”) . AT commands can be subdivided into four types, as shown in Table 3-1。

Table 3-1 AT Command Type

Type| Format| D e s c r i p t i on
---|---|---
query command| AT+?| return the current value of the parameter
set command| AT+=<…>| set user-defined parameter values
execute command| AT+| execute the internal program of the module without parameters
special command| 0x00 0x00 0x00| exit from the transparent transmission mode to AT command mode

Notes: Special command0x00 0x00 0x00 is only valid in transparent transmission mode, and does not contain the terminator “\r\n”.

Table 3-2 Error codes of AT command

Code D e s c r i p t i on
2 AT results have a generic error
3 AT command format error or no way to execute
4 ATcommandexpressionis error
5 AT command arguments parse is error

LoRaWAN Activation

According to the LoRaWAN specification, the necessary parameter configuration is required before using the module. There are two activation modes to choose from (OTAA activation mode is mainly used at present). The parameters required for each mode are different, as shown in Table 3-2.

Table 3-2Activation Mode and Required Parameters

Activation Description Parameters

Over the Air Activation (OTAA)

| The module obtains the network security  key  by  joining  the

network

|

DevEui、AppEui、AppKey, OTAA activation

Activation by personalization (ABP)

| The module has saved the network session key and application encryption key locally and  can  join  the  specified

LoRaWANserver

|

DevAddr、NwkSkey、AppSkey,  ABP activation

Transparent Transmission

  • A transparent transmission mode is used to send and receive application data.
  • In the command mode, use “AT + SWTMD” to select LoRaWAN communication or wM-bus communication .
  • In LoRaWAN, The module does not work until the module successfully join the network.

Data Communication Timing

Figure 4-1 describes in detail the flow of a complete data interaction after the module successfully joins the network when the user operates the module.

  1. The user waits for the module to be ready, that is, waits for BUSY to be low. When the module is ready, the user sends serial port data to the module.
  2. Wait for the serial port framing timeout (the data size transmitted by the user at one time is less than the maximum data packet limit of LoRaWAN or wM-bus), that is, wait for the completion of user data transmission from UART.
  3. When the module receives a frame of the user’s data, it will pull the BUSY pin high, indicating that the module is busy, and pull up the STAT pin at the same time.
  4. The module transmits data (uplink), and BUSY remains high. In LoRaWAN mode, if the Confirmed frame fails to be transmitted, the module will automatically retransmit.
  5. In LoRaWAN mode, if the current frame is Confirmed or the server has downlink data, the module will receive the data.
  6. The module completes data (uplink and downlink) processing, the BUSY pin is pulled low. If the communication data is abnormal, the STAT pin will remain high for indication. The STAT pin will not return to low until new data is coming from UART or the module switches to the command mode (inputting 0x00 0x00 0x00). If there is no abnormality, the STAT pin also becomes low.
  7. In LoRaWAN, if the server has downlink data, the module first completes data analysis and then sends it to the user through the UART after Td (default 10ms) time.

EWRF-Technology-US915-LoRaWAN-RF-Module-FIG-3

Note: According to the duty cycle requirements in CE RED, in LoRaWAN communication the next transmission interval is approximately 100 times the duration of the communication in the air. Otherwise, the LoRaWAN program may be forcibly stop sending user data.

The UART packet format in wM-bus
In wM-bus, the user’s device needs to send the packet to the UART of the module in the following format:

L C CI DATA
1 byte 1 byte 1 byte nbytes
  • L: Packet length(excluding itself)
  • C: Packet type, for example, SND-NR is 0x44
  • CI: Packet communication ID, for example, the short header of SND-NR is 0x7A
  • DATA: User application data, which is formed according to the data format of M-BUS, includes an 8-bit BCD meter readout, collection time in a certain format (year, month, day, hour), error flags, etc.

AT Command Set

  • The AT command set is classified into the Basic, LoRaWAN configuration, and wM-bus configuration.

Basic commands

  • The Basic AT commands are mainly to restart and configure UART and other application parameters that are not related to the network operation, as shown in Table 5-1。

Table5-1 Basic Commands

Command Description
AT Test and start AT commands
AT+RST Reset module
AT+GMI View version information
AT+SWTMD Switch from AT command mode to Transparent transmission mode
AT+RESTORE Restore to the factory default settings
AT+SAVE Save the parameters in the non-volatile memory
0x00 0x00 0x00(Hex) Switch from Transparent transmission mode to command mode

AT—AT Test


Write & Response

| ****

AT

| OK

or

+ERROR:

---|---|---
 | ****

:error code

Example

| AT

OK

AT+RST—Reset module


Command & Response

| ****

AT+RST

| OK

or

+ERROR:

---|---|---
Value &

Return

| ****

:error code

Example

| AT+RST

OK

AT+GMI—read information on module

Command &

Response

| ****

AT+GMI?

| + GMI:

OK

---|---|---
Value &

Return

| : includes manufacture ID, module name, version of hardware, LoRaWAN, and wM-BUSstacks

:error code

Example

| AT+GMI?

+ GMI:EWRF,1022MLA,V1.0.1,L1.0.3,W1.0.2 OK

AT+SAVE—Save parameters in the non-volatile memory


Command & Response

| ****

AT+SAVE

| OK

or

+ERROR:

---|---|---
Value &

Return

| ****

:error code

Example

| AT+SAVE

OK

AT+RESTORE—Restore to the factory default settings


Command & Response

| ****

AT+RESTORE

| OK

or

+ERROR:

---|---|---
Value &

Return

| ****

:error code

Example

| AT+RESTORE

OK

AT+SWTMD—SwitchAT Command Mode to Transparent Transmission Mode


Command & Response

| ****

AT+SWTMD=,[confirm],[port]

| OK

or

+ERROR:

---|---|---





Value & Return

| :Transparent Transmission:

l 0:LoRaWAN

l 1:wM-bus

[confirm]: data transmission type (only valid in the LoRaWAN)

l 0:Unconfirmed

l 1:Confirmed

[port]: data transmission port, value in decimal, default 10.(only valid in the LoRaWAN)

:error code

Example

| AT+SWTMD=0,1,12 OK

The example shows that the module is in the LoRaWAN, using the confirmed transmission on Port 12.

(0x00 0x00 0x00)—Switch Transparent Transmission Mode to AT Command Mode


Command & Response

| ****

0x00 0x00 0x00

| OK

or

+ERROR:

---|---|---
Value &

Return

| ****

:error code

---|---


Example

| 0x00 0x00 0x00

OK

LoRaWAN Configuration Commands

  • The LoRaWAN AT commands configure the network parameters of LoRaWAN, as shown in Table 5-2.

Table 5-2 LoRaWAN Configuration AT Commands

|
---|---
AT+LAPPEUI| read/write Application Eui
AT+LAPPKEY| read/write Application Key
AT+LDEVEUI| read/write Device EUI
AT+LNWKSKEY| read/write Network Session Key
AT +LAPPSKEY| read/write Application Session Key
AT+LDEVADDR| read/write Device address
AT+LSTATUS| Read the online status of the end device
AT+LJOIN| Join a LoRaWAN
AT+LSEND| Send data
AT+LADR| read/write Adaptive data rate
AT+LDATARATE| read/write RF data rate
AT+LCLASS| read/write the Class of end-device
AT+LJN1DL| read/write Join Accept RX1 delay, in ms
AT+LJN2DL| read/write Join Accept RX2 delay, in ms
AT+LRX1DL| read/write receiving RX1 delay, in ms
AT+LRX2DL| read/write receiving RX2 delay, in ms
AT+LRX2DR| read/write the data rate of Rx2
AT+ LRX2FQ| read/write the frequency of Rx2, in Hz
AT+ LTXP| read/write RF TX power

AT+LAPPEUI—read/write Application Eui

Read &

Response

| ****

AT+LAPPEUI?

| +APPEUI:

OK

---|---|---
Write & Response| ****

AT+LAPPEUI=

| OK

or

+ERROR:

Value &

Return

| :Application EUI

:error code

Example

| AT+LAPPEUI=AABBCCDD00112233

OK


Notes

| ****

Valid in OTAA mode, when read/ write AppEUI, the module returns Y1Y2…Y8 in hex, 8 bytes.

---|---

AT+LAPPKEY—read/write Application Key

Read &

Response

| ****

AT+LAPPKEY?

| +LAPPKEY:

OK

---|---|---


Write & Response

| ****

AT+LAPPKEY=

| OK

+ERROR:

Value &

Return

| :Application Key

:error code

Example

| AT+LAPPKEY=AABBCCDD00112233AABBCCDD00112233

OK


Notes

| ****

Valid in OTAA mode, when read/write Application Key, module returns Y1Y2…Y16 in hex, 16 bytes.

AT+LNWKSKEY—read/write Network Session Key

Read &

Response

| ****

AT+LNWKSKEY?

| +LNWKSKEY:

OK

---|---|---


Write & Response

| ****

AT+LNWKSKEY=

| OK

or

+ERROR:

Value &

Return

| :Network Session Key

:error code

Example

| AT+LNWKSKEY=AABBCCDD00112233AABBCCDD00112233

OK


Notes

| ****

Valid in ABP mode, when read/write Network Session Key, the module returns Y1Y2…Y16 in hex,16 bytes.

AT+LAPPSKEY—read/write Application Session Key

Read &

Response

| ****

AT+LAPPSKEY?

| +LAPPSKEY:

OK

---|---|---


Write & Response

| ****

AT+LAPPSKEY=

| OK

or

+ERROR:

Value &

Return

| :Application Session Key

:error code

Example

| AT+LAPPSKEY=AABBCCDD00112233AABBCCDD00112233

OK


Notes

| ****

Valid in ABP mode, when read/write Application Session Key, the module returns Y1Y2…Y16 in hex,16 bytes.

AT+LDEVADDR—read/write End-device Address

Read &

Response

| ****

AT+LDEVADDR?

| +LDEVADDR:

OK

---|---|---


Write & Response

| ****

AT+LDEVADDR=

| OK

or

+ERROR:

Value &

Return

| :Device address

:error code

Example

| AT+LDEVADDR=00112233

OK


Notes

| ****

Valid in ABP mode, when read/write Device Address, the module returns Y1Y2…Y4 in hex,4 bytes.

AT+LDEVEUI—read/write End-device identifier

Read &

Response

| ****

AT+LDEVEUI?

| +LDEVEUI:

OK

---|---|---


Write & Response

| ****

AT+LDEVEUI=

| OK

or

+ERROR:

Value &

Return

| : Device EUI, default is a globally unique ID generated by the chip.

:error code

Example

| AT+LDEVEUI?

+LDEVEUI=AABBCCDD00112233 OK


Notes

| ****

When read/write Device EUI, the module returns Y1Y2…Y8 in hex,8 bytes.

AT+LSTATUS—Read the online status of the End-device


Value & Return

| :Status:

l   0:unjoin

l   1:joined

:error code

---|---


Example

| AT+LSTATUS?

+LSTATUS=1 OK


Notes

| ****

Query whether the device is connected to a LoRaWAN

AT+LJOIN—Join a LoRaWAN





Write & Response

| ****




AT+LJOIN=,[dr],[nb]

| OK

or

+ERROR:


If the AT command is valid, then return OK, start authentication of joining, and return the authentication result:

+LEVT: JOIN OK

+LEVT: JOIN FAIL

---|---|---







Value & Return

| :Join mode

l 0:ABP,

l 1:OTAA [dr]:Join data rate

l 0:SF12,BW125

l 1:SF11,BW125

l 2:SF10,BW125

l 3:SF9,BW125

l 4:SF8,BW125

l 5:SF7, BW125 [nb]: Max attempts of Join

:error code

Example

| AT+LJOIN=1,3,8(JOIN settings:OTAA,SF9-BW125,Max attempts 8) OK

+LEVT: JOIN OK

AT+LSEND—Send data





Write & Response

| ****





AT+LSEND=,,

| >


Notes: Wait until the cursor comes out before entering the data to be sent


If joined a LoRaWAN, then returns:

+LEVT: SENDCONFIRMED/UNCONFIRMED OK

+LEVT: SEND FAIL

---|---|---




Value & Return

| : transmission port, in decimal

:data transmission type

l 0:Unconfirmed

l 1:Confirmed

.:data length

:error code

Example

| AT+LSEND=12,1,10

0123456789

  +LEVT: SENDCONFIRMED OK

Notes

| Users can send or receive data inTransparenttransmissionmode. This AT command only adds an option for

communication and ignore the pins of BUSY and STAT.

AT+LADR—read/write RF data-rate adaptation

Read &

Response

| ****

AT+LADR?

| +LADR:

OK

---|---|---


Write & Response

| ****

AT+LADR=

| OK

or

+ERROR:


Value & Return

| : ADR enable control, default is 1

  • ADR disable
  • ADR enable
:error code

Example

| AT+LADR=1

OK


Notes

|

AT+LDATARATE—read/write data- rate

Read &

Response

| ****

AT+LDATARATE?

| +LDATARATE:

OK

---|---|---


Write & Response

| ****

AT+LDATARATE=

| OK

or

+ERROR:





Value & Return

| : default is 3, range:

  • 0:SF12,BW125
  • 1:SF11,BW125
  • 2:SF10,BW125
  • 3:SF9,BW125
  • 4:SF8,BW125
  • 5:SF7,BW125
:error code

Example

| AT+LDATARATE=1

OK


Notes

| ****

If want to change the RF data rate, must disable ADR (AT+LADR=0).

AT+LCLASS—read/write End-device class

Read &

Response

| ****

AT+LCLASS?

| +LCLASS:

OK

---|---|---


Write & Response

| ****

AT+LCLASS=

| OK

or

+ERROR:



Value & Return

| :default classA

  • 0:class A
  • 1:class B(reserved)
  • 2:class C
:error code

Example

| AT+LCLASS=2

OK


Notes

| ****

Must set before joining a LoRaWAN network

AT+LJN1DL—read/writeJoin Accept RX1 delay

Read &

Response

| ****

AT+LJN1DL?

| +LJN1DL:

OK

---|---|---


Write & Response

| ****

AT+LJN1DL=

| OK

or

+ERROR:

Value &

Return

| : default is 5000 in milliseconds

:error code

Example

| AT+LJN1DL=5000

OK


Notes

|

AT+LJN2DL—read/writeJoin Accept RX2 delay

Read &

Response

| ****

AT+LJN2DL?

| +LJN2DL:

OK

---|---|---


Write & Response

| ****

AT+LJN2DL=

| OK

or

+ERROR:

Value &

Return

| : default is 6000 in milliseconds

:error code

Example

| AT+LJN2DL=6000

OK


Notes

|

AT+LRX1DL—read/writeRX1 delay

Read &

Response

| ****

AT+LRX1DL?

| +LRX1DL:

OK

---|---|---


Write & Response

| ****

AT+LRX1DL=

| OK

or

+ERROR:

Value &

Return

| : default is 1000 in milliseconds

:error code

Example

| AT+LRX1DL=5000

OK


Notes

|

AT+LRX2DL—read/writeRX2 delay

Read &

Response

| ****

AT+LRX2DL?

| +LRX2DL:

OK

---|---|---


Write & Response

| ****

AT+LRX2DL=

| OK

or

+ERROR:

Value &

Return

| : default is 2000 in milliseconds

:error code

Example

| AT+LRX2DL=5000

OK


Notes

|

AT+LRX2DR—read/write data rate of RX2

Read &

Response

| ****

AT+LRX2DR?

| +LRX2DR:

OK

---|---|---


Write & Response

| ****

AT+LRX2DR=

| OK

or

+ERROR:




Value & Return

| : default 0, range:

  • 0:SF12,BW125
  • 1:SF11,BW125
  • 2:SF10,BW125
  • 3:SF9,BW125
  • 4:SF8,BW125
  • 5:SF7,BW125
  :error code

Example

| AT+LRX2DR=0

OK


Notes

|

AT+LRX2FQ—read/write frequency of RX2

Read &

Response

| ****

AT+LRX2FQ?

| +LRX2FQ:

OK

---|---|---


Write & Response

| ****

AT+LRX2FQ=

| OK

or

+ERROR:

Value &

Return

| : default 869525000 in hz

:error code

Example

| AT+LRX2FQ=869525000

OK


Notes

|

AT+LTXP—read/write TX power

Read &

Response

| ****

AT+LTXP?

| +AT+LTXP:

OK

---|---|---


Write & Response

| ****

AT+LTXP=

| OK

or

+ERROR:






Value & Return

| : default 0, ranger:

  • 0:16 dBm
  • 1:14 dBm
  • 2:12 dBm
  • 3:10 dBm
  • 4:8 dBm
  • 5:6 dBm
  • 6:4 dBm
  • 7:2 dBm
:error code

Example

| AT+LTXP=1

OK


Notes

| ****

If want to change the transmitting power, must disable ADR (AT+LADR=0).

wM-bus Configuration Commands

  • The wM-bus AT commands config the parameters of wM-bus, as shown in Table 5-2.

Table 5-2 wM-bus Configuration AT commands

Command Description
AT+WMODE Read/write wM-bus mode
AT+WTXP Read/write wM-busTX power
AT+WADDR Read/write the address of the wM-bus device
AT+WKEY Read/write AES key of wM-bus device
AT+WEBC Read/write the number of encrypted blocks
 

Notes: The maximum response time for the above AT commands is 300 milliseconds

AT+WMODE—Read/write wM-bus mode

Read &

Response

| ****

AT+WMODE?

| +WMODE:

OK

---|---|---


Write & Response

| ****

AT+WMODE=

| OK

or

+ERROR:


Value & Return

| :wM-busmode, default is 0

  • 0:T1
  • 1:C1
:error code

Example

| AT+WMODE=0

OK

AT+ WTXP—Read/write wM-busTX power

Read &

Response

| ****

AT+WTXP?

| +WTXP:

OK

---|---|---


Write & Response

| ****

AT+WTXP=

| OK

or

+ERROR:



Value & Return

| : TX power, default is 2

  • 0:20dBm
  • 1:17 dBm
  • 2:14 dBm
  • 3:10 dBm
  :error code

Example

| AT+WTXP=1

OK

AT+ WADDR—Read/write the address of the wM-bus device

Read &

Response

| ****

AT+WADDR?

| +WADDR:

OK

---|---|---


Write & Response

| ****

AT+WADDR=

| OK

or

+ERROR:

Value &

Return

| : wM-bus device,8 bytes in Hex.

:error code

Example

| AT+WADDR=AABBCCDD00112233

OK

 |

AT+ WKEY—Read/write AES key of wM-bus device

Read &

Response

| ****

AT+WKEY?

| +WKEY:

OK

---|---|---


Write & Response

| ****

AT+WKEY=

| OK

or

+ERROR:

Value &

Return

| :wM-bus encryption KEY, 16 bytes in Hex.

:error code

Example

| AT+WKEY=AABBCCDD00112233AABBCCDD00112233

OK

AT+WEBC—Read/write the number of encrypted blocks

Read &

Response

| ****

AT+WEBC?

| +WEBC:

OK

---|---|---


Write & Response

| ****

AT+WEBC=

| OK

or

+ERROR:

Value &

Return

| :the number of encrypted blocks(16 bytes in a block)

:error code

Example

| AT+WEBC=2

OK

List of applicable FCC rules

  • FCC CFR Title 47 Part 15 Subpart C Section 15.247

Summarize the specific operational use conditions

  • The module has been certified for Mobile applications.
  • This transmitter must not be co‐located or operating in conjunction with any other antenna or transmitter.

Limited module procedures

  • Not applicable

Trace antenna designs

  • Not applicable

RF exposure considerations

This modular complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This modular must be installed and operated with a minimum distance of 20 cm between the radiator and the user body.

Antennas

  • Integral antenna with antenna gain1.5dBi, The antenna is permanently attached, and can’t be replaced.

Label and compliance information

  • The end product must carry a physical label or shall use e-labeling followed by KDB784748D01 and KDB 784748 stating “Contains Transmitter Module FCC ID:2BG9A-E1022MLA

Information on test modes and additional testing requirements

  • For more information on testing, please contact the manufacturer.

Additional testing, Part 15 Subpart B disclaimer

The modular transmitter is only FCC authorized for the specific rule parts (FCC Part 15.247) listed on the grant, and the host product manufacturer is responsible for compliance with any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. The final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed when contains digital circuity.

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

Read User Manual Online (PDF format)