IS700 Ducted System Instruction Manual
- August 18, 2024
- IS
Table of Contents
- IS700 Ducted System
- Product Usage Instructions
- Connect 40 degree temperature switch cable from the inline fan to
- COMMISSIONING HEATER AND DUCTING SYSTEM
- ACCESS PANEL INSTALLATION IS700
- ACCESS PANEL INSTALLATION IS900
- DUCTING INSTALLATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
IS700 Ducted System
Specifications
- Model: IS700, IS900
- Dimensions:
- IS700: W=780, H=655, D=580, H=300, W=1500, H=2000
- IS900: W=1100, H=715, D=670, H=300, W=1700, H=2000
- Gas Supply: Follow manufacturer’s instructions
- Electrical: 240 Volts
Product Usage Instructions
Timber Frame Construction for Ducted IS700–IS900
STEP 1: Build timber frame construction with required clearances and access
panels. Install the heater at least 300mm off the floor.
STEP 2: Position the heater into the timber frame construction as per the
provided dimensions.
Connecting Gas Supply to Heater
STEP 3: Follow manufacturer’s instructions on gas supply connection for
IS700 and IS900 models.
Connecting Fluing System to Heater
STEP 4: Follow manufacturer’s instructions for flue installation for IS700
and IS900 models – single flue or CoAxial flue installation.
Connecting Power to Heater
STEP 5: Ensure a power isolation switch is installed if directly to the
main electricity supply.
Fitting Offtake Duct to Heater
STEP 6: Secure the offtake to the top panel using wing nuts.
Connecting Duct and Inline Fan
STEP 7: Connect the 6 meters of 250mm duct to the offtake and inline fan.
Installing Inline Fan and Temperature Switch
STEP 8: Fit inline fan with support brackets at least 6 meters from the
offtake. Secure brackets with screws to a solid timber base.
STEP 9: Connect the temperature switch cable from the inline fan to the
offtake. Install the fan speed controller as per provided leads and plugs.
Commissioning Heater and Ducting System
Prior to finishing the timber frame construction, test run the heater and
ducting system by following the provided steps.
FAQ:
Q: What should I do if the heater is not operating correctly after
installation?
A: If you encounter issues with the heater post-installation, ensure all
connections are secure and refer to the troubleshooting section in the user
manual. If problems persist, contact customer
for assistance.
INSTALLION INS TRUCTIONS DUCTED SYSTEM IS700-IS900
Australian Patent PN 200110001S
- Serial Number:
- B.D. Number:
Timber Frame Construction for Ducted
IS700—IS900
STEP 1:
Build timber frame construction, see illustration below.
Take note of required clearances and access panels required for removal of the
off take and fluing system required for servicing of heater.
Note: Heater must be installed minimum of 300mm of the floor.
MODEL IS700
- A) W=780
- B) H=655
- C) D=580
- D) H=300
- E) W=1500
- F) H=2000
MODEL IS900
- A) W=1100
- B) H=715
- C) D=670
- D) H=300
- E) W=1700
- F) H=2000
STEP 2: POSITION HEATER INTO TIMBER FRAME CONSTRUCTION, SEE BELOW
CONNECTING GAS SUPPLY TO HEATER
STEP 3: Follow instructions in line with manufactures operating and
installation manual.
IS700 pages 23, 24
IS900 pages 20, 32, 33
CONNECT FLUING SYSTEM TO HEATER
STEP 4: Follow instructions in line with manufactures operating and
installation manual.
- IS700 pages 13, 16, 17, 18, 19. Single flue installation
- IS700 pages 14, 15, 16. CoAxial flue installation
- IS900 pages 16, 18, 19, 20, 21, 22. Single flue installation
- IS900 pages 17, 23, 24. CoAxial flue installation
CONNECT POWER TO HEATER
STEP 5:
NOTE:
If heater is directly wired to main electricity supply external power
isolation switch is to be installed to enable heater to be isolated from
incoming mains power.
FIT OFFTAKE DUCT TO HEATER
STEP 6:
Note: Secure offtake to top panel with wing nuts.
CONNECT 6 MTRS OF 250MM DUCT TO OFFTAKE
STEP 7:
STEP 8:
FIT INLINE FAN WITH SUPPORT BRACKETS TO 250MM TO DUCT
NOTE: Minimum distance of inline fan MUST be 6 meters from offtake. See
above. Inline fan brackets to be secured with screws to timber base. Please
note, inline fan must be installed with support brackets provided and fitted
and screwed to solid timber-base to absorb fan motor vibration. If this is not
done it will void the warranty from motor supplier.
Connect 40 degree temperature switch cable from the inline fan to
Offtake.
Install fan speed controller with leads and plugs supplied.
See below:
Step 9:
AURORA GAS HEATER
- DUCTING TAKE-OFF WITH 40’C TEMP, SWITCH
- DUCTING FAN WITH LEADS AND PLUG * 3-240 VOLTS. EXTENSION LEAD AS REQUIRED LENGTH (NOT SUPPLIED)
- FAN SPEED CONTROLLER WITH LEADS AND PLUGS
- 240 VOLTS EXTENSION LEAD, LENGTH AS REQUIRED (NOT SUPPLIED)
COMMISSIONING HEATER AND DUCTING SYSTEM
Step 10: Prior to Finish of Timber Frame construction with sheet plaster or alternative materials test run heater and ducting system.
- Remove main door from heater.
- Remove packaging material from inside firebox.
- Check log placement ensure all logs are in correct position.
- Test run heater either manually with heater operating switches or with remote control operation to ensure heater and ducting system is operating correctly.
- Follow instructions in operating manual for heater operation.
NOTE: For ducting system to be activated the heaters needs to be
operating on both burners for 30 Minutes in order for the inline fan to be
activated.
Note: Speed controller switch to be in ON position and turn speed
controller switch for selection of heat output to ducting system. PLEASE SEE
BELOW:
ACCESS PANEL INSTALLATION IS700
After heater and ducting system has been successfully commissioned.
Finish off timber frame construction with sheet plaster or alternative
materials.
NOTE:
Access panel on R/H and L/H side in plaster sheet or alternative mate-rials
are required for the removal of the OFFTAKE and flue system. For servicing of
the combustion fan and heat exchanger which are located at the back of the
heater.
Follow instructions supplied, and illustration below.
- Access panel construction R/H side timber frame construction Model IS700
- Access panel construction L/H side timber frame con-struction Model IS700
ACCESS PANEL INSTALLATION IS900
After heater and ducting system has been successfully commissioned.
Finish off timber frame construction with sheet plaster or alternative
materials.
NOTE: Access panel on R/H and L/H side in plaster sheet or alternative
mate-rials are required for the removal of the OFFTAKE and flue system.
For servicing of the combustion fan and heat exchanger which are located at
the back of the heater.
Follow instructions supplied, and illustration below.
- Access panel construction R/H side timber frame construction Model IS900
- Access panel construction L/H side timber frame construction Model IS900
DUCTING INSTALLATION
Finish off Ducting System in line with customer requirements
Note :
IS700 Maximum outlets 3
IS900 Maximum outlets 5
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>