AQUA FORTE RB345 Frequency Inverter Vario II User Guide
- August 9, 2024
- AQUA FORTE
Table of Contents
- AQUA FORTE RB345 Frequency Inverter Vario II
- Specifications
- IMPORTANT SAFETY INSTRUCTIONS
- TECHNICAL DATA
- BEFORE INSTALLATION
- CONNECTING TO POOL PUMP
- SETTING & OPERATION
- PROTECTION & ERROR CODE
- EXCLUSIONS
- DISPOSAL
- Frequently Asked Questions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AQUA FORTE RB345 Frequency Inverter Vario II
Specifications
- Model: Vario+ II
- Input power: 1 phase AC 220~240V
- Input voltage: 50Hz
- Output power: Max 1.1kW
- Output Voltage: 1ph, 0~240V Single phase
- Pump type: Max 6A 1200~2900rpm
- Cooling: Ventilation
- Net Dimension (LHW): 222117166mm
Thank you for purchasing our frequency inverter. Please read the manual carefully before installing or using it and keep it for future reference after installation.
SAFETY SYMBOLS
IMPORTANT SAFETY INSTRUCTIONS
To make the best use of this energy-saving device and to avoid the potential
risk of fire, electrical shock, SERIOUS injuries to people, or property
damage, please read
this user guide carefully before installation and keep it for future
reference. f.
This device can ONLY be used with pool pumps with a permanent split capacitor motor. Below is a typical single-speed swimming pool pump motor.
It is NOT compatible with:
- a. Single phase motors with centrifugal switch
- b. Pool pump motors with start relays or switch
- c. Series or DC motors
- d. Pool pump motors with faults in their rotors or capacitors
- e. Shaded-pole asynchronous motors
An RCD with a rated residual current not exceeding 30mA must be used with this product.
WARNING: If you are not sure of the compatibility of your pool pump with this device, please contact your supplier or manufacturer before proceeding with installation.
TECHNICAL DATA
BEFORE INSTALLATION
WARNING: Upon receipt of the device, check for any damages on the
packaging or product. DO NOT PROCEED with installation if any damages are
found, contact your supplier.
Do not use extension leads with the device. This can pose a danger,
particularly in the vicinity of a swimming pool.
Make sure the place you choose for installation meets the following conditions:
- Ambient temperature from -10 ~ 40°C
- 45 to 90 percent relative humidity, non-condensing
- Below 1000m above sea level
- No direct sunlight
- Good ventilation
For efficient cooling, please make sure it is installed with a minimum clearance surrounding it (Fig2), a blocked ventilation or an enclosed space with limited airflow may cause the overheating or potential operational failure of the inverter.
CONNECTING TO POOL PUMP
Please follow these steps and the wiring diagram for the correct connection.
The warranty may be compromised if the device is not installed by instructions
described in this manual
Only 1 pump can be connected to the inverter. Please do not connect any other
appliance to the output.
Mark the hole locations on the wall, install the expansion plugs supplied, fit
in the screws, and hang the device on the screws.
-
Turn off all electrical supply to the pool pump, and unplug it from the main switch or at the chlorinator which provides electrical power to the pump.
-
Plug the pool pump into the device’s power outlet (marked PUMP CONNECTION ONLY). Make sure the total length of the output cable of the device and the power cable of the pool pump is not more than 2m.
-
Plug the device into the main switch/chlorinator/timer connection where the pump was originally plugged into.
-
To reduce the electromagnetic interference, please connect the ground wire on the device to the ground terminal of the pool pump motor.
-
Switch all power back on.
-
Ensure the chlorinator/timer is active.
-
Now the device is ready to run.
-
Do not touch the heat sink while the device is in operation or until at least 30 mins after it has been switched off. Keep it out of reach of children.
-
Because of high voltage conversion components contained in the device, do not try to disassemble or replace any components in case of malfunction or breakdown. Before serving on the unit ,wait till the power light turned off or at least 3 minutes after power plug has been plugged off from input supply.
SETTING & OPERATION
Control panel
Mode selection
The frequency inverter has 3 modes (speed ranges).You can either run your pump
at a constant speed choosing from “M” or set up to 4 timers for daily
operation, each with an individual speed.
Mode
- Night (Low)
- Day (Medium)
- Backwash (High)
Speed range
- 1200~1650 rpm
- 1700~2400 rpm
- 2450~2900 rpm
Default speed
- 1400 rpm
- 2000 rpm
- 2900 rpm
Upon completion of self-priming, the pump will automatically switch to the speed pre-set, indicates the pump is running and show the current RPM and power consumption
Timer setting
To run the pump at a different time or speed to take advantage of electricity
tariffs during the day, you can set up to 4 timers.
Step1: Press to enter the timer setting
Step 2: Use to set the current time. Press
To move the cursor to the next setting. Press to
Choose a speed range for timer 1, and use it to decide on a specific speed if
needed.
Step3: Repeat the above steps to set the other 3 timers
Step4: Hold for 3 seconds or wait 10 seconds to save the setting
automatically.
A flashing indicates the device is waiting for the start time.
Step 5: press to check 4 timers, make sure there is no invalid setting.
OThe overlap setting of time will be considered invalid, the device will only
run based on the previous valid settings
During the timer setting, if you want to abandon it, hold for 3 seconds.
Note:
- If inactivated in 1 minute, the screen will lock automatically. Hold for 3 seconds to unlock the device.
- The device has power-off memory, operation will resume upon power restoration.
- Under OFF mode, hold for 3 seconds to retrieve the factory setting.
External control
This model Frequency Inverter has no external control options.
Parameter setting
Under OFF mode, hold for 3 seconds to enter the parameter setting.
PROTECTION & ERROR CODE
Note:
- AL01 is not an error indication: when it appears, the inverter will automatically switch to a lower speed to self-protect against high internal temperature. When the temperature drops back to 68°C the inverter will resume at the preset speed.
- When causes for E002/E101/E103 lifts, the device will resume working automatically, however when it appears a fourth time, the device will stop working, to resume operation, unplug the device and plug in & restart again.
EXCLUSIONS
- Under no circumstances should the manufacturer be held liable for any consequences resulting from inappropriate, incorrect installation, or mismatching of the product to pool pumps that are not compatible.
- The manufacturer reserves the right to change the specification of the product or its performance or the contents of the User Guide without notice in case of technical upgrade.
DISPOSAL
This symbol is required by European Community Directive 2012/19/UE on WEEE (Waste Electrical and Electronic Equipment) and means that your appliance must not be thrown into a normal bin. It will be selectively collected for reuse, recycling or transformation. Any substances it may contain which are potentially dangerous to the environment shall be eliminated or neutralized. Request information on recycling procedures from your retailer.
Aquaforte is a trademark of SIBO Fluidra Netherlands BV, Doornhoek 3950,
5465TC, VEGHEL, www.aqua-forte.com, info@aqua-
forte.com
AquaForte is een handelsmerk van SIBO Fluidra Netherlands BV, Doornhoek 3950,
5465TC, VEGHEL, www.aqua-forte.com, info@aqua-
forte.
Frequently Asked Questions
- Q: Can this inverter be used with any type of pool pump motor?
- A: No, this inverter is only compatible with pool pumps featuring a permanent split capacitor motor. Refer to section 1.1 for incompatible motor types.
- Q: What should I do if I find damages on the device upon receipt?
- A: If any damages are found on the packaging or product, do not proceed with the installation. Contact your supplier for further assistance.
- Q: Is it safe to use extension leads with this device?
- A: It is not recommended to use extension leads with the device, especially in the vicinity of a swimming pool, as it can pose a danger.
References
Read User Manual Online (PDF format)