RAIN BIRD CLP Series Compact Low Profile 7.5HP VFD Pump Station Owner’s Manual
- August 6, 2024
- RAIN BIRD
Table of Contents
RAIN BIRD CLP Series Compact Low Profile 7.5HP VFD Pump Station Owner’s
Manual
CLP Series – CLP07JAC4RS
Compact Low profile 7.5HP VFD Pump Station Up to 85 GPM at 75 PSI or up to 30 GPM at 90 PSI (See Performance Curve) CLP Series – CLP07JAC4RS Up to 85 GPM at 75 PSI or up
Rain Bird’s CLP Series pump station is designed for boost and flooded suction applications. The CLP Series is a complete pump package that is simple to install and operate. It includes a professional grade pump, a marine-grade aluminum enclosure, highest quality pump protection, and optional mounting for a Rain Bird controller. Home owner associations, small sports fields, schools, parks, and small agricultural projects are ideal applications. The CLP Series compact design, durable centrifu gal boost pump, and ease of installation, make this a perfect solution for applications with flows up to 85 GPM. With this complete solution there is no need to deal with the hassle of stick building a pump station with non-compatible parts and a makeshift enclosure. Only Rain Bird provides a totally integrated irrigation solution with UL listed components and a one year warranty that dependably delivers healthy and beautiful land scapes, saving time and minimizing maintenance.
At-A-Glance Description
- Variable Frequency Drive (VFD)
- Pump Start Relay included (24VAC/DC)
- Marine-Grade Aluminum Deck and Enclosure
- Powder-coated steel piping
- Isolation Valves for maintenance
- Flanged inlet and outlet connections
- Manual Switch provides user full control and override capabilities
- Available in single phase 208V, 220V and 230V
- Mounting options for Rain Bird Controllers (purchased separately)
- Flow Start Kit
- Surge Suppression Kit
Features
-
Plumbing Configurations
- Inlet and discharge piping on opposite sides of the enclosure (as shown)
- 4″priming port included
-
Mechanical Features
- Isolation valve
- Liquid filled pressure gauge
- Rugged centrifugal pump
-
Enclosure/External Connections
- Marine grade aluminum enclosure
- Marine grade aluminum deck
- Powder-coated steel piping
- Fused main power disconnect
-
• Pump Control
Pump Control: Requires Pump Start/Master valve signal from irrigation controller or optional CLPBSTW flow start kit.
24VAC Pump start relay included. Other voltages available as an accessory.
130 °F Temperature cutout switch
. Electrical Features
Power Requirement: Single or three phase 208V, 220V, 230V AC
TEFC Motor
UL listed components
• Energy efficient – Variable Frequency Drive (VFD) maintains constant pressure at varying flow demand- Stainless steel pressure transducer
- Red light for VFD alarms
- Green pump running light
- Pipe fill mode reducing pressure surge at pump start up
- Programmable override pump speed
- Loss of prime and pipe break alarm
- Dead head shut down
- Transducer loss shut down
-
Back panel for mounting Rain Bird controllers
- Pre-drilled for ESP-Me, ESP-Laxmi, and ESP-LXD Series Controllers. (Rain Bird **controller sold separately)
**
* Separate independent power feed required to power controller.
* Controller can be mounted inside or outside of aluminum enclosure
Options and Accessories
- Suction Inlet Gauge
- ESP/IVM Pump start relay
- Pump Station Bypass
- 4″ Check Valve (suction)
- Vertical Static Suction Screen 4″
REFER TO PERFORMANCE FLOW CHART OR PUMP CURVE TO DETERMINE YOUR OPERATING FLOW AND PRESSURE COMBINATION
DIMENASION
Profile View
NOTES:
- SLAB DETAIL IS PROVIDED FOR ILLUSTRATION ONLY. THE ARCHITECT OR PROJECT ENGINEER SHOULD BE CONSULTED FOR CONSTRUCTION DETAIL.
- DIMENSIONS ARE FOR REFERENCE ONLY. EXTRERNAL PLUMBING TO BE FIELD FIT.
- STATION WEIGHS ~ 250 LBS.
Rain Bird Corporation – Pumps Division 6991 E. Southpoint Road Tucson, AZ
85756
Applications Group: 520-806-5620
Fax: 520-741-6191
E-mail: pumps@rainbird.com