Checkline RMS-TD-180 Digital Humidity Temperature Transmitter Instructions
- August 3, 2024
- CHECKLINE
Table of Contents
- Checkline RMS-TD-180 Digital Humidity Temperature Transmitter
- Frequently Asked Questions
- PRODUCT OVERVIEW
- Introduction
- For your safety
- On receipt of your device
- Using the device – Basics
- Product types
- Checking the device’s status
- Configuring the device
- Device information
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Checkline RMS-TD-180 Digital Humidity Temperature Transmitter
Specifications
- Option: RMS-TD-DISPLAY
- Display: 1
- Keyboard: 2
Frequently Asked Questions
Q: What should I do if I encounter incorrect measurements?
A: Incorrect measurements can result from various factors. Ensure proper usage following the instructions in the manual. If issues persist, contact customer support for assistance.
PRODUCT OVERVIEW
- Display
- Keyboard
Introduction
Information about this operating manual
This operating manual is designed to enable you to use the RMS-TD safely and
effectively. It i s part of the device, has to be stored nearby and must be
easily accessible to users at all times. All users are required to carefully
read and make sure that they have understood this operating manual before
using the RMS-TD . All of the safety and operating instructions detailed in
this manual have to be observed to ensure the safety of the device.
Limitation of liability
All of the information and instructions provided in this operating manual have
been compiled on the basis of the current standards and regulations, the state
of the art, and the extensive expertise and experience of Checkline Europe BV.
Checkline Europe BV does not accept any liability for damage associated with
the following, which also voids the warranty:
- Non-observance of this operating manual
- Improper use
- Inadequately qualified users
- Unauthorized modifications
- Technical changes
- Use of unapproved spare parts
This fast measuring procedure can be affected by a range of different factors. We, as the manufacturer, do not accept any liability for any incorrect measurements and associated consequential damage.
Customer service
For technical advice, please contact our customer service. Your purchased
measuring instrument can be calibrated, and the adjustment checked by using
suitable test ampoules / calibration ampoules. For this purpose, use only the
calibration solutions distributed by Checkline Europe.
For your safety
The device complies with the following European directives:
- Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) •
- Electromagnetic compatibility (EMC) The device corresponds to state-of-the-art technology. However, it is still associated with a number of residual hazards. These hazards can be avoided through strict observance of our safety information.
Proper use
- Transducer for measuring and transmitting relative humidity and temperature in fixed i nstallation • The sensor technology used makes it possible to detect even small fluctuations in humidity and their tendencies quickly and reliably so that preventive actions can be taken.
- For some applications (e.g. installation in sewage pipes) it is necessary to use a remote measuring probe for the reason of temperature adjustment.
Improper use
The device must not be used in ATEX.
User qualifications
The device must only be operated by people who can be expected to reliably
take the measurements. The device must not be operated by people whose
reaction times may be slowed due to, e.g. the use of drugs, alcohol or
medication.
All persons using this device must have read, understood and follow the
instructions provided in the operating manual.
General safety information
The following safety information has to be observed at all times to avoid
damage to objects and injury to people:
In case of damages or loose parts on the device, contact Checkline Europe.
All of the device’s technical features have been inspected and tested before
delivery. Every device has a serial number. Do not remove the tag with the
serial number.
Warranty
The warranty does not apply to:
- Damage resulting from non-observance of the operating manual
- Damage resulting from third-party interventions
- Products that have been used improperly or modified without authorisation
- Products with missing or damaged warranty seals
- Damage resulting from force majeure, natural disasters, etc.
- Damage from improper cleaning
On receipt of your device
Taking the device out of its packaging
- Take the device out of its packaging.
- Next, make sure that it is not damaged and that no parts are missing.
Making sure that all of the components have been included
Make sure that all of the components have been included by checking the
package contents against the following list:
Scope of supply
-
RMS-TD
-
Connecting cable of 1.9 m length
-
Operating manual
Optional accessories (not all available for RMS-TD ): -
Relay output for moisture for RMS-TD
-
Mounting bracket for RMS-TD
-
Drip-catcher for RMS-TD
-
RS232 interface – described in a separate operating manual
-
USB interface – described in a separate operating manual
-
Custom-made design – flat rate for air humidity transmitter series per order
-
Factory calibration certificate, calibration equipment, certified calibration ampoules and reference devices – for continuous monitoring
Using the device – Basics
Selecting the product type
To do so: The device has to be in the measuring window.
For an overview of the different product types and the criteria for selecting
them, please refer to “3. Product types”.
Press the button to move from one product type to the next. » The product type you selected will now be shown at the top of the display.
Taking a measurement
In order to obtain current measuring values, the device must be in the measuring window.
Product types
The product types “absolute Humidity” and “specific humidity” are only available with RMS-TD 60 and RMS-TD 90.
Product type | Definition | Unit | Measuring range |
---|---|---|---|
absolute Humidity | absolute air humidity | g/m³ | 0 to 130 g/m³ |
Dew Point | Dew Point | °C or °F | 55 °C to +60 °C |
specific humidity | specific humidity | g/kg | LF-TD 60: 0 to 125 |
g/kg
LF-TD 90: 0 to 150
g/kg
relative Humidity| relative Humidity| % RH| 0 to 100 %
Definition of product types
-
Absolute humidity
The absolute air humidity shows the contained amount of water in gramme per cubic metre of air. The absolute humidity is a direct degree for the amount of water vapour contained in a certain air volume. It shows how much condensate can precipitate or how much water has to be evaporated in order to obtain the desired humidity. -
Dew Point
The dew point is the temperature to which the air that is not completely saturated with water vapour must be cooled so that it is completely saturated. When a room with the current relative humidity cools down to the dew point temperature, the water vapour begins to condense. -
Relative humidity
Indicates the relationship between the current water vapour pressure and the maximum possible, the so-called saturation vapour pressure.
The relative humidity shows the degree the air is saturated with water vapour. -
Examples:
50% relative humidity: At the current temperature and pressure, the air is half saturated with water vapour. 100% relative humidity means that the air is totally saturated with water vapour. If the air has more than 100% humidity, the excessive humidity would condense or precipitate as mist. -
Specific humidity
The specific humidity indicates the mass of water in grams contained per kilogram of air. The specific humidity remains unchanged with changes in volume as long as no moisture is added or removed.
Checking the device’s status
- Press twice or hold for 2 seconds.
- Select Status . To do so, press and confirm by pressing .
The display will then show the status indicator humimeter.
The display will show the following information (figure 2):
No. | Name |
---|---|
1 | Serial number |
2 | Software version |
3 | Battery status |
4 | Memory status |
- Confirm by pressing .
- Press to leave the main menu .
Configuring the device
Selecting a language
-
Press twice or hold for 2 seconds.
-
Select Options. To do so, press and confirm by pressing .
-
Select Language. To do so, press or and confirm by pressing .
-
Navigate to the required language. To do so, press or and confirm by pressing .
The setting has been saved. -
Press to leave the Options menu.
-
Press to leave the main menu.
Activating options
-
Press twice or hold for 2 seconds.
-
Select Options. To do so, press and confirm by pressing .
-
Select Unlock. To do so, press and confirm by pressing .
The display will now appear as shown in figure 3.
On delivery, the four-digit password is the device’s serial number. -
Inputting numbers:
Press and hold to quickly scroll to the required number and either press it for 3 seconds or press to confirm the selected number (figure 4). -
Moving back:
Press to switch to another input level.
To move back press . -
Confirm the four-digit password by pressing.
The setting has been saved.
The °C/°F, Auto Inc, Anybus, Password, Reset options are now activated. -
Press to leave the Options menu.
-
Press to leave the main menu.
Deactivating options
Once the device has been switched restarted, the °C/°F, Auto Inc, Anybus,
Password, Reset options will be deactivated again.
Selecting °C/°F
To do so: All of the options must be activated (see “5.2 Activating options”).
-
Press twice or hold for 2 seconds.
-
Select Options. To do so, press and confirm by pressing .
-
Select °C/°F. To do so, press and confirm by pressing .
-
Navigate to the required temperature scale, i.e. Celsius (°C) or Fahrenheit (°F).
To do so, press and confirm by pressing .
The setting has been saved. -
Press to leave the Options menu.
-
Press to leave the main menu.
Calibrating the device
The calibration function is described in a separate operating manual.
Auto Inc
To do so: All of the options must be activated (see “7.2 Activating options”).
- Press twice or hold for 2 seconds.
- Select Options. To do so, press and confirm by pressing .
- Select Auto Inc. To do so, press and confirm by pressing .
The setting has been saved.
Now the measuring value displayed in the third line automatically changes
between “Absolute humidity”, “dew point” and “specific humidity” every 30
seconds.
- Press to leave the Options menu.
- Press to leave the main menu.
Anybus
The Anybus function is described in a separate operating manual
Changing the password
To do so: All of the options must be activated (see “7.2 Activating options”).
-
Press twice or hold for 2 seconds.
-
Select Options. To do so, press and confirm by pressing .
-
Select Password. To do so, press and confirm by pressing .
The display will show the current password -
Overwrite the current password. To do so, press and hold to quickly scroll to the required number and either press it for 3 seconds or press to confirm the selected number.
Moving back:
Press to switch to another input level.
To move back, press . -
Confirm the new four-digit password by pressing .
The setting has been saved. -
Press to leave the Options menu.
-
Press to leave the main menu.
Resetting the device to its factory settings
To do so: All of the options must be activated (see “7.2 Activating options”).
-
Press twice or hold for 2 seconds.
-
Select Options. To do so, press and confirm by pressing .
-
Select Reset. To do so, press and confirm by pressing .
The display will then show the message Reset? (figure 7). -
Confirm by pressing .
The device will now be reset to its factory settings.
All of your personal settings will be lost.
The display will show the status indicator humimeter (figure 8).
Resetting the device will not affect the saved measuring values.
Device information
Technical data
Display resolution| 0.1 g/m3 absolute humidity,
0.1 % rel. air humidity,
0.1 °C / 0.3 °F dew point,
0.1 g/kg specific humidity,
0.1 °C/ 0.3 °F temperature
---|---
Measuring range specific humidity| RMS-TD 60: 0 to 125 g/kg
RMS-TD 90: 0 to 150 g/kg
Operating temperature| Sensor dependent
-20 °C to +85 °C (electronics)
Storage temperature| -20 °C to +60 °C
Temperature compensation| Automatic
Power supply| 12 to 29 VDC
Current consumption| 60 mA (with display backlight, without output)
Menu languages| English, German, French, Italian, Spanish, Portuguese, Czech,
Polish, Russian, International
Display| 128 x 64 illuminated matrix display
Housing dimensions| 70 x 32 x 120 mm
Device IP rating| IP 54
Warranty
- Checkline Europe (Checkline) warrants to the original purchaser that this product i s of merchantable quality and confirms i n kind and quality with the descriptions and specifications thereof. Product failure or malfunction arising out of any defect i n workmanship or material i n the product existing at the time of delivery thereof which manifests i tself within one year from the sale of such product, shall be remedied by repair or replacement of such product, at Checkline’s option, except where unauthorized repair, disassembly, tampering, abuse or misapplication has taken place, as determined by Checkline. All returns for warranty or non-warranty repairs and/or replacement must be authorized by Checkline, i n advance, with all repacking and shipping expenses to the address below to be borne by the purchaser.
- THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION. CHECKLINE SHALL NOT BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER’S OR SUPPLIER’S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE.
- Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. The duration of any i mplied warranty, including, without limitation, fitness for any particular purpose and merchantability with respect to this product, is limited to the duration of the foregoing warranty. Some states do not allow limitations on how long an implied warranty lasts but, notwithstanding, this warranty, in the absence of such limitations, shall extend for one year from the date of invoice.
CHECKLINE EUROPE
Dennenweg 225B, 7545 WE, Enschede, the Netherlands
Tel: +31 (0)53-4356060 // Email: info@checkline.eu
Every precaution has been taken in the preparation of this manual. Checkline
Europe assumes no responsibility for errors or omissions. Neither is any
liability assumed for damages resulting from the use of information contained
herein. Any brand or product names mentioned herein are used for
identification purposes only, and are trademarks or registered trademarks of
their respective holders.
References
- Checkline Europe - Your Partner For Measuring Equipment
- Checkline Europe - Your Partner For Measuring Equipment
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>