HANCHU ESS ESS HESS-HY-T-05K Hybrid Three Phase User Manual

July 31, 2024
HANCHU ESS

HANCHU ESS ESS HESS-HY-T-05K Hybrid Three Phase

Product Information

Specifications

  • Model: HESS-HY-T-T1-05-12K
  • Transformerless hybrid inverter
  • 2 or 3 MPP trackers
  • Battery connection
  • Indoor and outdoor applications

Product Usage Instructions

  • Intended Use
    The product is designed to work as a transformerless hybrid inverter with 2 or 3 MPP trackers. It can connect to a battery to store energy from the PV array or convert it to a grid-compliant three-phase current. The product can also supply power from the battery or PV system in case of a grid fault.

  • Safety Instructions
    Read and understand the safety instructions provided in the user manual to prevent personal injury and property damage. Ensure the product is disconnected from all energy sources before working on it. Wear suitable personal protective equipment for any maintenance tasks.

  • Installation Requirements
    Connect the product only with PV modules of protection class II. Do not connect any other energy sources to the product. Operate the product within the permitted operating ranges and follow installation requirements at all times.

  • Battery Compatibility
    Use only an intrinsically safe lithium-ion battery approved by Hanchu ESS. Ensure the battery voltage range is within the permissible input voltage range of the product.

  • Compliance
    Operate the product only in countries approved by Hanchu ESS and the grid operator. The type label must be attached and legible at all times. Adhere to all local standards and directives for safe operation.

FAQ

  • Q: Can I connect energy sources other than PV modules to the product?
    A: No, do not connect any sources of energy other than PV modules to the product as it can cause irreparable damage.

  • Q: What type of battery should I use with the product?
    A: Use only an intrinsically safe lithium-ion battery approved by Hanchu ESS and ensure its voltage range is compatible with the product.

  1. HESS-HY-T-05K/06K/08K/10K/12K
  2. HESS-HY-T1-05K/06K/08K/10K/12K

General Information

This quick installation guide does not replace the description in the user manual. The contents of this guide may be updated or revised due to product development. The information in this guide is subject to change without notice. The latest version of this document and the manual for installation, commissioning, configuration, and decommissioning are to be found in PDF format at www.hanchuess.com.

Safety

Intended use

  • The product is a transformerless hybrid inverter with 2 or 3 MPP trackers and a battery connection that feeds the direct current of the PV array into the connected battery or converts it to grid-compliant three-phase current and then feeds it into the utility grid. The product also can convert the direct current supplied by the battery into grid-compliant three-phase current. The product has a backup function that can continue to supply selected circuits with power from the battery or PV system in the event of a grid fault.
  • The product is intended for indoor and outdoor applications.
  • The product must only be connected with PV modules of protection class II (by IEC 61730, application class A). Do not connect any sources of energy other than PV modules to the product.
  • The product is not equipped with an integrated transformer and therefore has no galvanic isolation. The product must not be operated with PV modules which require functional grounding of either the positive or negative PV conductors. This can cause the product to be irreparably damaged. The product may be operated with PV modules with frames that require protective earthing.
  • All components must remain within their permitted operating ranges and their installation requirements at all times.
  • Use the product only per the information provided in the user manual and with the locally applicable standards and directives. Any other application may cause personal injury or damage to property.
  • The product must only be operated in connection with an intrinsically safe lithium-ion battery approved by Hanchu ESS. The entire battery voltage range must be completely within the permissible input voltage range of the product.
  • The product must only be used in countries for which it is approved by Hanchu ESS and the grid operator.
  • The type label must be permanently attached to the product and must be in a legible condition.
  • This document does not replace any regional, state, provincial, federal, or national laws, regulations, or standards that apply to the installation, electrical safety, and use of the product.

Important safety instructions
The product has been designed and tested strictly according to international safety requirements. As with all electrical or electronic devices, there are residual risks despite careful construction. To prevent personal injury and property damage and to ensure the long-term operation of the product, read this section carefully and observe all safety information at all times.

DANGER

Danger to life due to high voltages of the PV array or the battery!
The DC cables connected to the battery or the PV array may be live. Touching the DC conductors or the live components can cause lethal electric shocks. If you disconnect the DC connectors from the product under load, an electric arc may occur leading to electric shock and burns.

  • Do not touch non-insulated cable ends.
  • Do not touch the DC conductors.
  • Do not touch any live components of the product.
  • Do not open the product.
  • Observe all safety information of the battery manufacturer.
  • All work on the product must only be carried out by qualified personnel who have read and fully understood all safety information contained in this document and the user manual.
  • Disconnect the product from all voltage and energy sources and ensure it cannot be reconnected before working on the product.
  • Wear suitable personal protective equipment for all work on the product.

DANGER

Danger to life due to electric shock when touching live components in backup mode!
Even if the AC breaker and the PV switch of the inverter are disconnected, the parts of the system may still be live when the battery is switched on due to backup mode.

  • Do not open the product.
  • Disconnect the product from all voltage and energy sources and ensure it can not be reconnected before working on the product.

DANGER

Danger to life due to fire or explosion when batteries are fully discharged!
A fire may occur due to incorrect charging of fully discharged batteries. This can result in death or serious injury.

  • Make sure that the battery is not fully discharged before commissioning the system.
  • Contact the battery manufacturer for further proceedings if the battery is fully discharged.

DANGER

Danger to life due to burns caused by electric arcs through short-circuit currents!
Short-circuit currents in the battery can cause heat accumulation and electric arcs if the battery is short-circuited or wrongly installed. Heat accumulation and electric arcs may result in lethal injuries due to burns.

  • Disconnect the battery from all voltage sources before performing any work on the battery.
  • Only use properly insulated tools to prevent accidental electric shock or short circuits during installation.
  • Observe all safety information of the battery manufacturer.

DANGER

Danger to life due to electric shock when touching live system components in case of a ground fault!
If a ground fault occurs, parts of the system may still be alive. Touching live parts and cables may result in death or lethal injuries due to electric shock.

  • Disconnect the product from voltage and energy sources and ensure it cannot be reconnected before working on the device.
  • Only touch the cables of the PV modules on their insulation.
  • Do not touch any parts of the substructure or frame of the PV array.
  • Do not connect PV strings with ground faults to the product.

WARNING

Danger to life due to electric shock from the destruction of the measuring device due to overvoltage!
Overvoltage can damage a measuring device and result in voltage being present in the enclosure of the measuring device. Touching the live enclosure of the measuring device results in death or lethal injuries due to electric shock.

  • Only use measuring devices with a measurement span higher than the DC input voltage range equal to or higher than the voltage rating of the product.

CAUTION

Risk of burns due to high temperature.
Some parts of the enclosure can become hot during operation.

  • During operation, do not touch any parts other than the enclosure lid of the product.

CAUTION

Risk of injury due to weight of product.
Injuries may result if the product is listed incorrectly or dropped while being transported or mounted.

  • Transport and lift the product carefully. Take the weight of the product into account.
  • Wear suitable personal protective equipment for all work on the product.

Symbols on the label

EU Declaration of Conformity

Within the scope of the EU directives

  • Radio Equipment Directive 2014/53/EU
    (L 153/62-106. May 22. 2014) (RED)

  • Restriction of the use of certain hazardous substances 2011/65/EU
    (L 174/88, June 8, 2011) and 2015/863/EU (L 137/10, March 31,2015) (RoHS)

JiangsuHanchuEnergyTechnologyCo., LTD. confirms herewith that the products described in this document comply with the fundamental requirements and other relevant provisions of the above-mentioned directives. The entire EU Declaration of Conformity can be found at www.hanchuess.com.

Overview

Object Description
1 Battery Port
2 DC-switch
3 PV Input
4 INV-Logger A200
5 Communication ports
6 AC connector
7 EPS connector
8 Additional grounding screw

Scope of Delivery

Object Description Quantity
A Inverter 1
B Wall Bracket 1

C

| AC connector| 1
Terminal| 5
D| AC connector ×1 (10-12kH)| 1

E

| EPS connector| 1
Terminal| 5
F| DC connector| HESS-HY-T| 2
HESS-HY-T1| 3
G| Battery connector| 1
H| INV-Logger A200| 1
I| Document| 1
J| External CT| 1
K| Smart meter| 1
L| Fastener package| 1
M| Communication terminal package| 1

Mounting Environment

Dimensions

Mounting

Second Protective Grounding

AC CONNECTION

EPS Connection

DC Connection

TYPE 1

TYPE 2

Battery Connection

Communication Setup

Communication connection

Object

| Description| Terminal|

PIN definition

---|---|---|---
1| 2| 3| 4| 5| 6| 7| 8
RJ45-3| Monitor| COM2| RS485A| RS485B| GND| X| X| X| RS485A| RS485B
RJ45-4| BMS| COM5| X| GND| X| CANAH| CANAL| X| RS485A| RS485B

Object

| Description| Terminal|

PIN definition

---|---|---|---
1| 2| 3| 4| 5| 6

Terminal-1

|

DO1/DO2

|

4pin

| Multifunction Relay 1| Multifunction Relay 2|
B| A| B| A

Terminal-2

|

\

|

6pin

| Smart Meter| PT100 Temperture Sensor| UFR Device
RS485A| RS485B| Positive| Negative| Positive| Negative

Terminal-3

|

DI*4/DRM0

|

6pin

| Ripple Control Receiver Device| DRMS Device

DI_4

|

DI_3

|

DI_2

|

DI_1

|

REF GEN/0

| COM LOAD/0

or GND

Terminal-4

|

CT

|

6pin

| Current Transformer L1(U)| Current Transformer L2(V)| Current Transformer L3(W)
Red| Black| Red| Black| Red| Black

Current Transformer connection (optional)

Smart meter connection (optional)

INV-Logger A200 connection

Contact

Please contact our Service Department if you have any technical questions about our products.

The following information is needed to provide necessary assistance:

  • Inverter model
  • Inverter serial number
  • Photovoltaic module model
  • Photovoltaic modules number and strings number connected to each MPPT ——Fault code
  • Installation location
  • Jiangsu Hanchu Energy Technology Co.,LTD
  • Hotline: 0510-88876668
  • Web: www.hanchuess.com
  • Add.: No. 588, Jinhui Road, Huishan District, Wuxi, Jiangsu, China.

Jiangsu Hanchu Energy Technology Co.,LTD.