Specifications

  • Brand: Hampton Bay
  • Model: HBLG1803R
  • Manufacturer: LG Electronics
  • Operation Modes: Cooling, Energy Saving, Ventilating Fan, Dry Mode
  • Fan Speeds: High, Low, Medium
  • Timer: Up to 12 hours

FAQs

  • Q: What should I do if the unit is not cooling efficiently?
    • A: Check the air filters and ensure they are clean. Also, verify that the unit is set to the correct cooling mode and fan speed.
  • Q: Can I use the air conditioner without the remote control?
    • A: Yes, you can operate the air conditioner using the control panel on the unit if the remote control is not available.
  • Q: How often should I clean the air filters?
    • A: It is recommended to clean the air filters at least once a month to maintain optimal performance.

OVERVIEW

HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1
\(37\)

ROOM AIR CONDITIONER OWNER’S MANUAL

  • Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
  • MODELS, MODELOS: HBLG1803R

FOR YOUR RECORDS

While lhe model and 86rial moors here:

  • Model#
  • Serial#-

You can find them on a label on the side of each unit

  • Dealer’s Name
  • Date Purchased

Staple your receipt to this page in the event you need it to prove the date of purchase or for warranty issues.

READ THIS MANUAL

  • inside you will find many helpful hints on how to use and maintain the yo11Jr air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioners,
  • You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart, of
  • Troubleshooting Tips First, you may not need to call for service at all.

Precaution

  • Contact the authorized service technician for repair or maintenance of this unit.
  • Contact the installer for the installation of this unit.
  • The air conditioner is not intended for use by young children or invalids without supervision.
  • Young children should be supervised to ensure that they do not play with the air conditioner.
  • When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using genuine replacement parts.
  • Installation work must be performed by the National Electric Code by qualified and authorized personnel only.

To prevent injury to the user or other people and property damage, the following instructions must be followed.

  • Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.

HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(2\)

  • The meanings of symbols used in this manual are as shown below.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(3\)

Installation

  • Always install the expansion panel(s). No installation may cause fire and electric shock accidents.
  • Do not place the power cord near a heater. It may cause fire and electric shock.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(4\)
  • Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.
  • Do not disassemble or modify products. It may cause failure and electric shock.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(5\)

Operation

  • Plug in the power plug properly. Otherwise, it will cause electric shock or fire due to heat generation or electric shock.
  • Do not operate or stop the unit by inserting or pulling out the power plug It will cause electric shock or fire due to heat generation.
  • Do not damage or use an unspecified power cord. It will cause electric shock or fire.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(6\)
  • Do not modify the power cord length. It will cause electric shock or fire due to heat generation.
  • Do not share the outlet with other appliances. It will cause electric shock or fire due to heat generation.
  • Always plug into a grounded outlet. No grounding may cause electric shock (See Installation Manual).HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(7\)
  • Do not modify the power cord length. It will cause electric shock or fire due to heat generation.
  • Do not share the outlet with other appliances. It will cause electric shock or fire due to heat generation.
  • Always plug into a grounded outlet. No grounding may cause electric shock (See Installation Manual).HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(8\)
  • Do not allow water to run into electric parts. It will cause the failure of the machine or an electric shock.
  • Leave the door closed while the air conditioner is running. It is not designed to cool the entire house.
  • Ventilate before operating the air conditioner when the gas goes out. It may cause explosion, fire, and burn.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(9\)
  • Never touch the metal parts of the unit when removing the filter. They are sharp and may cause injury.
  • Do not block the inlet or outlet. It may cause the failure of an appliance or an accident.
  • Ensure that the outer case is not damaged by age or wear. If leaving appliance damaged, there is the concern of damage due to the falling of the product.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(10\)
  • Be cautious not to touch the sharp edges when installing. It may cause injury.
  • Hold the plug by the head when taking it out. It may cause electric shock and damage.
  • Turn off the main power switch when not using it for a long time. Prevent accidental startup and the possibility of injury.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(11\)
  • Do not place heavy objects on the power cord and take care so that the cord should not be pressed. There is a danger of fire or electric shock.
  • If water enters the product, turn off the power switch of the main body of the appliance. Contact the service center after taking the power plug out from the socket.
  • Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(12\)
  • Turn off the power and breaker first when cleansing the unit. Since the fan rotates at high speed during operation, it may cause injury.
  • Do not put a pet or house plant where it will be exposed to direct airflow. This could injure the pet or plant.
  • Do not use this appliance for special purposes such as pets, food, precision machinery, or objects of art. It is an air conditioner, not a precision refrigeration system.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(13\)
  • Always insert the filter securely. Clean it every two weeks. Operation without filters will cause failure.
  • Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
  • Do not drink water drained from the air conditioner. / Do not direct airflow at room occupants only. It contains containments and will make you sick. / This could damage your health.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(14\)

Preparing for operation

  1. Contact an installation specialist for installation.
  2. Plug in the power plug properly.
  3. Do not share the same outlet with other appliances
  4. Do not use an extension cord.
  5. Do not start/stop the operation by plugging/unplugging the power cord.
  6. If the cord/plug is damaged, replace it only with an authorized part.

Usage

  1. Being exposed to direct airflow for an extended period could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods.
  2. Due to the possibility of oxygen deficiency, ventilate the room when using together with stoves or other heating devices.
  3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Usage in such a manner could harm such property.

Cleaning and maintenance

  1. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
  2. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is accidentally triggered while cleaning the inner parts of the unit.

Service
For repair and maintenance, contact your authorized service dealer.

Remote Control Operations

The remote control and control panel will look like those represented in the following pictures.

HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1
\(15\)

  1. POWER
    • Operation starts when this button is pressed and stops when you press the button again.
  2. TEMPERATURE CONTROL
    • The thermostat monitors room temperature to maintain the desired temperature.
    • The thermostat can be set between 60°F~86°F (16°C~30°C).
    • The unit takes an average of 30 minutes to adjust the room temperature by 1°F.
  3. OPERATION MODE SELECTOR
    • Select cooling mode to cool the room.
    • Select energy saver mode for energy saving operation.
    • Select fan mode for basic ventilating fan operation.
    • Select dry mode for dry operation.
  4. FAN SPEED SELECTOR
    • For increased power while cooling, select a higher fan speed.
  5. Steps: High → Low → Med
    • ON/OFF TIMER
    • The timer can be set to start and stop the unit in hourly increments (up to 12 hours).
  6. REMOTE CONTROL SENSOR

AUTO RESTART

In failure of electric power, the unit runs as previous setting operation.

Inserting the Remote Control Batteries

  1. Push out the cover on the back of the remote control with your thumb
  2. Pay attention to polarity and insert two new AAA 1.5V batteries.
  3. Reattach the cover.

NOTICE: Do not use rechargeable batteries. Make sure that both batteries are new.

  • In order to prevent discharge, remove the batteries from the remote control if the air conditioner is not going to be used for an extended period of time
  • Keep the remote control away from extremely hot or humid places.
  • To maintain optimal operation of the remote control, the remote sensor should not be exposed to direct sunlight.
  • The remote control can be mounted on a wall using the mountable holder.

Adjusting the Air Flow Direction

Vent Control

For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air.

NOTICE: Before using the ventilation feature, position the vent lever straight by pulling Part A out and snapping it into place.

  • Airflow can be adjusted by changing the direction of the air conditioner’s louvers.
  • This can also increase the cooling efficiency of the air conditioner.

Adjusting Horizontal Air Flow Direction

  • Adjusting the vertical louvers left and right will change horizontal airflow.

Adjusting Vertical Air Flow Direction

  • Adjusting the horizontal vane up and down will change vertical airflow. The vane can be adjusted by nudging the vane backward or forward.

Recommended orientation of louvers

  • Adjust louvers to face upwards when cooling to maximize cooling efficiency.

Care and Maintenance

Turn the power off and unplug the power plug before cleaning the air conditioner.
Air Filter

  • The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner.

How to remove the air filter

  1. The grille may be opened from the top for easy maintenance after installation.
  2. Open the inlet grille by pulling off the exposed door on the top of the unit (based on installation).
  3. Pull the tab slightly to release the filter. Pull the filter in the same direction as the opening.
  4. Clean the filter with warm, soapy water. The water should be below 40°C (104°F).
  5. Rinse off and gently shake off excess water from the filter. Let it dry before replaceing it.

Drainage

  • The base pan may overflow due to high humidity. To drain the excess water, remove the drain cap from the back of the unit and secure the drainpipe.
  • When pressing the drainpipe into place, apply force in the direction away from the fins to avoid injuring yourself.

How to Attach Drain Pan

The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the air) is drained to the outside. In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed from the air may cause some water to collect. To remove this excess water you can install the drain pan as detailed below.

  1. Take the drain pan which is located in the air discharge.
  2. Remove the hole rubber from the base-pan (for some models).
  3. Install the drain pan to the right corner of the cabinet with 4 (or 2) screws.
  4. Connect the drain hose of 3/5″ inside diameter to the outlet located at the bottom of the drain pan. You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied).

Hardware Installation

Product Features

CAUTION: This appliance should be installed in accordance with national wiring regulations. The following intormation serves acts as a guide to help to explain product features.

HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1
\(24\)

  1. CABINET
  2. FRONT GRILLE
  3. AIR FILTER
  4. AIR INTAKE (INLET GRILLE)
  5. AIR DISCHARGE
  6. VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER)
  7. EVAPORATOR
  8. HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER)
  9. CONTROL PANEL
  10. POWER CORD
  11. COMPRESSOR
  12. BASE PAN
  13. BRACE
  14. CONDENSER
  15. REMOTE CONTROLLER

Installing the Power cord

You can choose between two methods below according to your window stool shape and preference.

  • Using slit “A”
    • Fasten the stopper using 2 screw holes, and lead out the power cord through slit “A”.
  • Using slit “B”
    • Fasten the stopper using left screw hole, and rotate properly to lead the power cord out through slit “B”.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(25\)

How to Install the Unit

  1. To prevent vibration and noise, make sure the unit is installed securely and firmly.
  2. Install the unit where the sunlight does not shine directly on the unit.
  3. There should be no obstacles, such as a fence and wall, within 20″ from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
    • CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.
  4. Install the unit a little slanted so the back is slightly lower than the front (about 1/2*). This will force condensed water to flow to the outside.
  5. Install the unit with the bottom about 30″~60″ above the floor level.

Window Requirements
NOTICE: All supporting parts should be secured to firm wood, masonry, or metal.

  • This unit is designed for installation in standard double hung windows with actual opening widths from 29″ to 41″.
  • The top and bottom window sash must open sufficiently to allow a clear vertical opening of 18″ from the bottom of the upper sash to the window stool.

Installation Kits Contents

Suggested Tool Requirements
SCREWDRIVER(Philips and Flatead), RULER, KNIFE, HAMMER, PENCIL, LEVEL

PREPARATION OF CHASSIS

  1. Remove the screws which fasten the cabinet at both sides and at the back.
  2. Slide the unit from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet.
  3. Cut the window sash seal to the proper length. Peel off the backing and attach the Foam-Seal 11 to the underside of the window sash.
  4. Remove the backing from the top upper guide Foam-PE 15 and attach it to the bottom of the Upper Guide.
  5. Attach the upper guide onto the top of the cabinet with 3 Type A screws 5.
  6. Insert the Frame Guides 14 into the bottom of the cabinet.
  7. Insert the Frame Curtain 1 into the Upper Guide and Frame Guides 14).
  8. Fasten the curtains to the unit with 10 Type A screws 5.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(30\)

Cabinet Installation

  1. Open the window. Mark a line on the center of the window stool between the side window stop moldings. Loosely attach the sill bracket to the support bracket using the carriage bolt and the lock nut.
  2. Attach the sill bracket to the window sill using the screws (Type B). Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked window stool.
  3. Using the M-screw and the lock nut, attach the support bracket to the cabinet track hole. Use the first track hole after the sill bracket on the outer edge of the window sill. Tighten the carriage bolt and the lock nut. Be sure the cabinet slants outward.
    • CAUTION: Do not drill a hole in the bottom A pan. The unit is designed oe in tree witor approximately 1/2″ of water in bottom pan.
  4. Pull the bottom window sash down behind the Top retainer bar until they meet.
    • NOTICE:
    1. Do not pull the window sash down so tightly that the movement of Frame curtain is restricted. Attach the cabinet to the window stool by driving the screws (Type B) through the cabinet into window stool.
    2. The cabinet should be installed with a very slight tilt downward toward the outside.HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(31\)
  5. Pull each Frame curtain fully to each window sash track, and pull the bottom window sash down behind the Top retainer bar until it meets.
  6. Attach each Frame curtain the window sash by using screws (Type C.) (See Fig. 6)
  7. Slide the unit into the cabinet.(See Fig. 7) at cabinet’s sides.
    • CAUTION: For security purpose, reinstall screws(Type A) at cabinet’s sides.
  8. Cut the Foam-strip to the proper length and insert between the upper window sash and the lower window sash.(See Fig. 8)
  9. Attach the Window locking bracket with a screw (Type C.) (See Fig. 9)HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1 \(32\)
  10. Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (See Fig.10)
  11. Lift the inlet grille and secure it with a screw (Type A) through the front grille.(See Fig. 10)
  12. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet.

Electrical Data

HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1
\(34\)

All wirring should be made in accordance with local electrical codes and regulations.

NOTICE: Aluminum house wiring may pose special problems. Consult a qualified electrician.

Electrical Safety

  • IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER’S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED
  • The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet (Fig. 11) to minimize the hazard of electric shock.
  • The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
  • 230, 208, and 230/208 VOLT UNITS
  • These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged into a matching properly grounded three-prong wall receptacle for your protection against possible shock hazard.
  • If such an outlet is not present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances.
  • NOTICE: DO NOT USE AN EXTENSION CORD on 230, 208, and 230/208 Volt units.

Common Problems and Solutions

Before calling for service, please review the following list of common problems and solutions.
The air conditioner is operating normally when:

  • You hear a pinging noise. This is caused by water being picked up by the condenser on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.
  • You hear the thermostat click. This is caused by the compressor cycle starting and stopping.
  • You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid conditions or on rainy days. This water overflows and drips from the rear of the unit.
  • You hear the fan running while the compressor is silent. This is a normal operational feature.

The air conditioner may be operating abnormally when:

HAMPTON-BAY-HBLG1803R-Room-Air-Conditioner-FIG-1
\(36\)

Documents / Resources

| HAMPTON BAY HBLG1803R Room Air Conditioner [pdf] Owner's Manual
HBLG1803R, HIBLG1803R, HBLG1803R Room Air Conditioner, HBLG1803R, Room Air Conditioner, Air Conditioner, Conditioner
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HAMPTON BAY User Manuals

Related Manuals