ABL 912-00455-001 LED Fixture Instruction Manual
- July 25, 2024
- ABL
Table of Contents
ABL 912-00455-001 LED Fixture
Specifications:
- Product Name : WallConnect LED Luminaire
- Model Number : GR2153
- Designed and tested to meet CSA requirements
- Suitable for use in wet locations
Product Usage Instructions
Safety Instructions:
It is crucial to follow all safety instructions provided to prevent any accidents or damage.
- Risk of Electric Shock:
- Disconnect or turn off power before installation or servicing.
- Verify the correct supply voltage before proceeding.
- Follow NEC and local code requirements for electrical connections.
- Cap all wiring connections with UL-approved wire connectors.
- Risk of Injury:
- Wear gloves and safety glasses during handling, installation, and maintenance.
- Avoid direct eye exposure to the light source when operational.
- Risk of Burn:
- Allow the lamp/fixture to cool before handling.
- Do not exceed the maximum wattage marked on the luminaire label.
- Follow the manufacturer’s warnings for driver type, burning position, mounting, replacement, and recycling.
- Risk of Fire:
- Keep combustible materials away from the lamp/lens.
- Do not operate near persons or materials affected by heat or drying.
- Risk of Product Damage:
- Avoid connecting components under load.
- Avoid damaging wire insulation during installation.
Installation:
Follow these steps for proper installation:
-
1. Unpack the fixture and remove the door by loosening the two…
FAQ
- Q: What should I do if I encounter a problem during installation?
- A: If you encounter any issues during installation, please contact the Holophane Field Service Department at 866-759-1577 for assistance.
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance on this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by a person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. The frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to the user. The refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water, and wiped dry. Should the optical assembly become dirty on the inside, wipe the refractor/lens and clean in the above manner, replacing damaged gaskets as necessary
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that the supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL-approved recognized wire connectors.
CAUTION
RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch the enclosure or light source.
- Do not exceed the maximum wattage marked on the luminaire label.
- Follow all manufacturer’s warnings, recommendations, and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling
CAUTION
RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer pack, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around the fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed the fixture’s maximum ambient temperature.
- Only use the fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event, your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.Always read the fixture’s complete installation instructions prior to installation for any additional fixture specific warnings.
Please see product-specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands
Indoor/Outdoor
Lithonia Lighting Carandini Holophane RELOC
Indoor Lighting
Gotham Mark Architectural Lighting Peerless Renaissance Lighting Winona Lighting
Outdoor Lighting
American Electric Lighting Antique Street Lamps Hydrel Tersen
Controls
DARK TO LIGHT Lighting Control & Design ROAM Sensor Switch Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2011 Acuity Brands Lighting, Inc. All rights reserved. 3/15
INTRODUCTION
Product Description. The WallConnect luminaire has been designed and
tested to meet the applicable requirements of CSA and is suitable for use in
wet locations.
Alternate Information Sources. If additional questions arise relative to
the Wallpack luminaire that this document or your supplier cannot answer,
please refer them to:
Holophane
Field Service Department
P.O. Box 3004 Newark, OH 43058-3004
866-759-1577
INSTALLATION
Installation Preparation
Unpack the fixture and remove the door by loosening the two captive closure screws or latches. Disconnect the green grounding wire and quick-disconnect harness (If control options are present).
These will be reconnected after mounting.
Remove the reflector with 3 screws to gain full access to the mounting
features.
Use 3/8” drill bit or 3/16” drill bit to drill out the desired mounting hole
positions from the pre-formed mounting positions.
Installation and Maintenance
Apply caulk to cover the mounting fasteners on the inside of the enclosure to prevent moisture entry.
- Reinstall the reflector with three screws from step 2.1.2
Conduit Attachment and Wiring
-
Remove the threaded plug from the desired conduit entry point.
-
Apply pipe thread sealant to threads to prevent moisture entry.
-
Install ½” NPT threaded conduit.
NOTE : If routing wires through the top entry point, remove the reflector from step 2.1.2 if not done so already. -
Pull wiring into the luminaire and make the appropriate wire connections and cover each connection using wire nuts or other methods meeting state or local electrical code
If the terminal block option was ordered, make the appropriate supply wire connections per the diagram below. -
Reinstall the reflector with three screws from step 2.1.2
CAUTION
DO NOT LEAVE ANY SUPPLY WIRING INSIDE THE FIXTURE. SUPPLY WIRE IN CONTACT WITH HOT INTERNAL COMPONENTS MAY CAUSE INSULATION FAILURE, A SHORT CIRCUIT CONDITION, AND DAMAGE TO THE FIXTURE.
Installation Completion
- Re-install the door.
- Plug in the connectors between the ballast and supply lines.
- Swing the door closed and tighten the closure screws securely
MAINTENANCE
Cleaning
- Disconnect or shut off electrical power to the fixture location.
- Open the door by loosening the two captive closure screws or latches.
- Wipe the reflector and the glass refractor with a clean dry cloth to remove any dust and dirt.
- Retighten the closure screws or secure latches.
- PR7 option
- How to adjust receptacle position:
- Loosen the two screws (do not remove from locking ring)
Cleaning
- Disconnect or shut off electrical power to the fixture location.
- Open the door by loosening the two captive closure screws or latches.
- Wipe the reflector and the glass refractor with a clean dry cloth to remove any dust and dirt.
- Retighten the closure screws or secure latches.
- PR7 option
- How to adjust receptacle position:
- Loosen the two screws (do not remove them from the locking ring)
- Use a screwdriver to rotate the housing clockwise until the “North” indicator points in the desired direction (typically due North).
- The rotatable dimming receptacle is designed to limit the total rotation to 355 degrees with a stop feature. If the desired direction can’t be achieved by turning clockwise due to the stop feature, simply turn the center receptacle housing counterclockwise to the desired position.
- Once the desired aiming is achieved, the mounting screws must be retightened to the recommended 15 inch-pounds of torque.
Cell Connect
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case Nthe user will be required to correct the interference at his own expense.
Limited Warranty and Limitation of Liability
The Holophane limited warranty and limitation of liability is published in the “Terms and Conditions” section of the current Holophane buyer’s guide and is available from your local Holophane sales representative.
Acuity Lighting Group, Inc.
214 Oakwood Ave., Newark, OH 43055
IM-345-A 12/17 ©2012 Acuity Lighting Group Inc.
All Rights Reserved.
Visit our web site at www.holophane.com
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Fabricantes de alumbrado publico e iluminación inteligente - CARANDINI
- U.S. Environmental Protection Agency | US EPA
- U.S. Environmental Protection Agency | US EPA
- Holophane | Lighting solutions for commercial, industrial, emergency and outdoor applications.
- Holophane | Lighting solutions for commercial, industrial, emergency and outdoor applications.
- Lithonia Lighting® | Best Value in Lighting
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>