AGSTGC Timed Gas Control Flyer Owner’s Manual
- July 25, 2024
- AGS
Table of Contents
- AGSTGC Timed Gas Control Flyer
- PRODUCT INFORMATION
- Product Usage Instructions
- FAQ
- Product Overview
- PROVIDING SAFETY & CONTROLS IN
- Features
- Product Installation
- SIMPLE OPERATION
- WEATHERPROOF COVERS
- PROGRAMMABLE TIMER
- PLUG & PLAY INSTALLATION
- CONTACT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AGSTGC Timed Gas Control Flyer
PRODUCT INFORMATION
Specifications
- Power Supply: 110VAC or 24VAC/DC
- Dry Contact Inputs: For remote panic buttons and fire alarms
- Material: Strong polyac PA-765
- Control: Timed supply of gas for grills, heaters, and decorative fire features
- Gas Solenoid Valve: AGS gas solenoid valves for ON/OFF operation
Product Usage Instructions
Operating the Gas Controller
- To open gas supply, press the ON button.
- Press the ON button again to reset the automatic gas shut-off timeout. Press the OFF button to manually shut off the gas supply.
LED Status Display
The LED display provides clear indications:
- Green: Illuminates when gas is being supplied
- Amber: Turns yellow 10 minutes before automatic shut-off; beeps and flashes intermittently when 5 minutes remain
- Red: Illuminates when a remote emergency stop device is activated; press ON to re-enable gas supply
Programmable Timer Add-On
You can add a programmable timer (AGSPGT7M) for scheduled timed supply of gas over your fire features.
Weatherproof Covers
- Wall Mount Cover (AGSTGCWMCOVER) and Flush Mount Cover (AGSTGCFMCOVER) are available to protect the device from physical damage, dust, and environmental conditions.
FAQ
- Q: What should I do if the gas supply is automatically shut off?
- A: Press the ON button to re-enable/open the gas supply.
- Q: How can I manually shut off the gas supply?
- A: Press the OFF button to manually shut off the gas supply. Q: Can I use a panic button to shut off the gas supply?
- Yes, activating a panic button will de-energize and close the connected gas solenoid valve. A manual reset is required to restart the gas supply.
PROTECT LIFE & PROPERTY
TIMED CONTROL FOR GAS FEATURES
Product Overview
PRODUCT OVERVIEW
The AGSTGC provides a timed supply of gas to outdoor units such as grills, heaters and decorative fire features.
Upon pressing the “ON” button, the AGSTGC will begin a timed supply of gas for 30 minutes, 1 hour, 2 hours, or 3 hours. The time settings can be adjusted internally via dip switches. By simply pressing the “ON” button again during operation, the timer will reset to the selected timeout period. Once the timer has reached the end of the selected time out setting, the front LED will flash to warn the user of the timeout. When the AGSTGC is on, the controller will provide 120VAC or 24VAC/DC to a normally closed gas solenoid valve, energizing it open.
When the “OFF” button is pressed, the selected timeout has been reached, or a panic button is activated, the output will de-energize and close the connected gas solenoid valve. If a panic button is pressed, the unit will require a manual reset to re-start the gas supply. The AGSTGC is manufactured in a strong and modern polyac enclosure which provide protection from damage. The controller is designed to replace field constructed solutions for timed supply and panic shut down.
PROVIDING SAFETY & CONTROLS IN
- SCIENCE LABORATORIES
- COMMERCIAL KITCHENS
- BOILER ROOMS
- PARKING GARAGES
- GAS FEATURES
- EMS STATIONS
Features
- Manual Reset
- After alarm condition
- Four Time Delay Options
- 30 Minutes, 1 hour, 2 hours or 3 hours
- Adaptable Utility Output
- For grill, gas features & heaters. 110VAC or 24VAC/DC
- Power Supply
- 110VAC or 24VAC/DC
- Dry Contact Inputs
- For remote panic buttons and fire alarms
- Easy To Use
- Clear LED status display
- Modern & Compact Design
- Strong polyac PA-765, designed to withstand daily use
- Automatic Control Of Gas
- ON/OFF operation with AGS gas solenoid valves
Product Information
- 30+ YEARS OF EXPERIENCE
Product Installation
SIMPLE OPERATION
- Green. Remains illuminated when gas is being supplied.
- Amber. The controller LED will turn yellow ten (10) minutes before the automatic gas shut off timeout is reached and when five (5) minutes remain the buzzer will beep, and the yellow LED will then intermittently flash. After this time, the gas will automatically shut off until reactivated.
- Red. Remains illuminated when a remote emergency stop device has been activated. The gassupply is isolated until the emergency has been investigated, rectified, and reset. Press ON to re-enable/open the gas supply.
WEATHERPROOF COVERS
AVAILABLE
These indoor/outdoor low-profile covers protect devices without restricting
legitimate operation.
The versatile cover offers excellent protection against physical damage (both
accidental and intentional), dust and grime as well as severe environmental
conditions inside and out.
Wall Mount Cover:
- AGSTGCWMCOVER
Flush Mount Cover:
- AGSTGCFMCOVER
PROGRAMMABLE TIMER
ADD ON FOR 24/7 CONTROL
AGSPGT7M
- Add a 7 day programmable timer to achieve a scheduled timed supply of gas over your fire features
PLUG & PLAY INSTALLATION
CONTACT
FIND OUT MORE
- info@americangassafety.com
- (727)-608-4375
- 6304 Benjamin Road, Suite 502, Tampa, FL
- www.americangassafety.com
- in: @american-gas-safety
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>