eurolux ERC60X, ERC90X Commercial Canopy Rangehood Installation Guide
- June 3, 2024
- eurolux
Table of Contents
eurolux ERC60X, ERC90X Commercial Canopy Rangehood
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR EUROLUX RANGEHOOD
ERC60X/ERC90X
CONGRATULATIONS
Welcome to the Eurolux Kitchen Community and thank you for choosing one of our
many fantastic appliances. Before you use the rangehood we strongly recommend
that you read through the whole user manual which provides the description of
this product and the proper use of its functions. To avoid the ever-present
risks involved with using an electrical appliance it is vital that the
appliance is installed correctly and that you read the safety instructions
carefully to avoid misuse and hazards.
It is important that you retain these instructions, proof of purchase as well
as other important documents about this product for future reference.
Due to continual product development, Eurolux reserves the right to alter
specifications or appearances without notice.
Remove all packaging and dispose responsibly – recycle where facilities are
available.
IMPORTANT SAFETY INSTRUCTIONS
Important:
Please read the entire instructions before installing the rangehood. Check
appliance for damage or missing parts (if damaged, do not install).
- Always switch power off prior to installation.
- All electrical work must be done in accordance with local and national electrical codes as applicable.
- For safety, this product must be earthed.
- A power outlet should be within 1m of the power cord exit from the rangehood.
- The socket must be accessible and enable the end user to isolate the rangehood from the power for the purpose of internal cleaning or maintenance.
- Stainless steel or powder coat is very easily damaged during installation if abraded or knocked by tools.
- Protect the rangehood with the cardboard box or plastic bag during installation.
- All ducting must comply with local requirements and building codes.
- Suitable fixings will be required to mount this rangehood.
- The minimum distance between an electric or gas hob surface and the lowest part of the rangehood is 650mm. If the instructions for the hob specify a greater distance, this has to be taken into account.
- Stainless steel is very easily damaged during installation if abraded or knocked by tools. Protect the rangehood with the cardboard box or plastic bag during installation.
- All electrical work must be done by a registered electrician in accordance with local and national electrical codes as applicable. For your safety, this product must be earthed.
- If the supply cord of this equipment is damaged, it must only be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
- This rangehood is designed for indoor use only and must be in a dry location.
- Disconnect the power supply when any maintenance is carried out, including changing light bulbs or inspecting filters. Do not touch lights after appliance use.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Young children should be supervised to ensure that they do not play with the appliance.
- There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances burning gas or other fuels.
- There is a fire risk if cleaning is not carried out in accordance with the instructions. You must read the details concerning the method and frequency of cleaning.
- Do not flambé under the rangehood.
- Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels.
- The minimum distance between the hob surface and the lowest part of the rangehood is 650mm. If the instructions for the hob specify a greater distance, this has to be taken into account.
- Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air is fulfilled. If recirculating, take care no ventilation becomes blocked or partially blocked.
- CAUTION: Accessible parts may become hot when used with cooking appliances.
- WARNING: Failure to install the screws or fixing devices in accordance with these instructions may result in an electrical hazard.
- It is recommended that the rangehood is started before cooking, and allowed to run for a period after cooking has finished (to remove vapours & odours). Turn off when not in use.
- The rangehood is intended to be installed over a hob with no more than four elements.
APPLIANCE DETAILS
Reference | Qty | Product components |
---|---|---|
1 | 1 | Hood body, complete with controls, light, blower, and |
filter
2.1| 1| Lower decorative chimney
2.2| 1| Upper decorative chimney (optional)
3| 1| Flange (Optional)
4| 1| Exhaust pipe
5| 2| The activated charcoal filter (optional)
10| 7| Screws 5 x 50
11| 7| Wall plugs
12| 6| Screws 4,2 x 9,5
20| 1| Hood fixing bracket
21| 1| Chimney fixing bracket (optional)
INSTALLATION INSTRUCTIONS
WALL DRILLING AND BRACKET FIXING
As a first step, proceed with the following drawings:
- A vertical line up to the ceiling or up to the upper limit, at the center of the area in which the hood is to be fitted.
- A horizontal line A at 920-1020 mm above the cooker top.
- A horizontal line B at a X mm above the horizontal line A.
- A horizontal line C at a 190mm below the horizontal line A.
Mark Points:
- Mark a point (1) on the horizontal line A, 80 mm to the vertical reference line.
- Repeat this operation on the other side and on the vertical reference line , checking that the three marks are levelled.
- Mark a point (2) on the horizontal line B, 40 mm to the vertical reference line.
- Repeat this operation on the other side , checking that the two marks are leveled.
- Mark a point (3) on the horizontal line C, 170 mm to the vertical reference line.
- Repeat this operation on the other side , checking that the two marks are leveled.
Fix the brackets :
Drill holes at the marked points with a ɸ10 mm drill bit.
- Insert the Wall Plugs 11 into the holes.
- Fix the hood fixing bracket 20 with 3 screws 10 (5 x 50) at the horizontal line A.
- Fix a Chimney fixing bracket 21 with 2 screws 10 (5 x 50) at the horizontal line B.
Hook the hood body:
- Hook the hood body to the bracket 20.
- Level the hood body itself.
- Remove the filter from the inside of the hood body, fix the screws 10 to Wall Plugs 11 at the points (3).
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using
either a flexible or rigid pipe ɸ 150 or ɸ 120 mm, the choice of which is left
to the installer.
- To install a ɸ 120 mm air exhaust connection, insert the reducer flange 3 on the hood body outlet.
- Fix the pipe 4 in position using sufficient pipe clamps (not supplied).
- Remove possible charcoal filters.
CHIMNEY ASSEMBLY
Lower Decorative Chimney
Fix the Lower Decorative Chimney to the hood body with 2 screws 12 (4.2 x 9.5)
supplied with the hood.
Upper Decorative Chimney
Fix the upper chimney onto the bracket 21 with 2 screws 12 (4.2 x 9.5)
supplied with the hood.
OPERATING INSTRUCTIONS
Speed adjustment:
**** | OFF MOTOR SWITCH: Press on this switch to stop the motor operation. |
---|---|
**** | SPEED SWITCH: Press on this switch, the motor runs at LOW speed. |
**** | SPEED SWITCH: Press on this switch, the motor runs at MEDIUM speed. |
**** | SPEED SWITCH: Press on this switch, the motor runs at HIGH speed. |
**** | ON/OFF LIGHTING SWITCH: Press on this switch to turn on the lights, and |
press again to turn them off.
MAINTENANCE AND CLEANING
GREASE FILTERS
CLEANING METAL SELF-SUPPORTING GREASE FILTERS
- The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.
- Pull the comfort panels to open them.
- Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards.
- Any kind of bending of the filters has to be avoided when washing them. Before fitting them again into the hood make sure that they are completely dry. (The color of the filter surface may change throughout the time but this has no influence to the filter efficiency).
- When fitting the filters into the hood pay attention that they are mounted in correct position the handle facing outwards.
ACTIVATED CHARCOAL FILTER (RECIRCULATION VERSION)
REPLACING THE ACTIVATED CHARCOAL FILTER
These filters are not washable and cannot be regenerated, and must be replaced
approximately every 4 months of operation, or more frequently with heavy
usage.
- Remove the metal grease filters
- Remove the saturated activated charcoal filter.
- Fit the new filters.
- Replace the metal grease filters.
REPLACING THE LIGHT
- You cannot replaced the light bulbs, the entire light module has to be replaced.
- When changing the light modules, the contacts are live.
- Before changing the light module(s), unplug the appliance from the mains or switch off the circuit breaker in the fuse box.
- Remove the grease filter .
- Disconnect the terminal of LED light.
- Press LED light on the back of the front plate, take the LED light out.
- Replace the lamp(commercially available LED lamp (max.1.5w).
Lamp type | Max Power | Voltage | Picture | Lamp Cap | ILCOS D code |
---|---|---|---|---|---|
Square / Dimesion: 33.2mm x 120mm | 1.5W | DC 12 V | —— | DSS-1.5-S-33.2 |
/120
Reinstall LED light module
- Press LED light on the front of front plate, install the LED light on the front plate.
- Connect the terminal of LED light and light leads.
- Reinstall the grease filter.
TROUBLESHOOTING
Fault | Cause | Solution |
---|
Light on, but motor does not work
| The blades are blocked.| Check the blades.
The capacitor is damaged.| Replace capacitor.
The motor is damaged.| Replace motor.
The internal wiring of motor is cut off/ disconnected. An unpleasant smell may
be produced.| Replace motor.
Both light and motor do not work| Apart from the above mentioned, check the
following:
Light damaged.| Replace lights.
Power cord loose.| Connect the wires as the electric diagram.
Oil leakage| Outlet and the air ventilation entrance are not tightly sealed.|
Take down the outlet and seal with glue.
Vibration
| The blade, if damaged, can cause vibrating.| Replace the blade.
The motor is not tightly fastened.| Fasten the motor tightly.
The cooker hood is not tightly fixed.| Fixed the cooker hood tightly.
Insufficient suction
| The distance between the cooker hood and the cooker top is too large.|
Readjust the distance.
Too much ventilation from open doors or windows.| Choose a new place to
install the appliance or close some doors/windows.
The machine inclines
| The fixing screws are not tight enough.| Tighten the fixing screw and make i
horizontal.
The hanging screws are not tight enough| Tighten the hanging screw and make it
horizontal.
AUSTRALIAN & NEW ZEALAND PRODUCT WARRANTY
AUSTRALIAN CUSTOMERS
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and for compensation for any other foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of
acceptable quality and the failure does not amount to a major failure.
NEW ZEALAND CUSTOMERS
Nothing herein contained shall be construed in any way as excluding or
limiting your rights under the Consumer Guarantee Act 1993.
OUR WARRANTY
Subject to the following conditions, this product is also covered by the
manufacturer’s THREE (3) YEAR WARRANTY from the date of purchase, covering all
parts and labour (Our W arranty). Our Warranty (which is subject to the
conditions below) covers rectification free of charge of any fault arising
from defective materials or components, or faulty workmanship. The product
will be repaired or replaced at the option of Eurolux. Our Warranty is subject
to the product being used for single family domestic household use.
Our Warranty operates in addition to (and does not exclude, restrict or
modify) any rights or remedies to which you may already be entitled to under
the Australian Consumer Law or any consumer guarantees law relating to this
product.
WHAT IS COVERED: By Our Warranty
During the warranty period, Eurolux or its authorised Service Centre will at
no extra charge, if your appliance is readily accessible without the need of
special equipment and subject to the terms and conditions of this warranty,
repair or replace any parts which it considers defective.
WHAT IS NOT COVERED BY OUR WARRANTY
- Incomplete or improper installation.
- Normal wear and tear e.g. cleaning, light globes,filters etc.
- Failure resulting from power surges and electrical storms.
- Insect or vermin infestation.
- Unauthorised repairs or use of non genuine Eurolux parts.
- Any failure caused by the product not being used in accordance with the instruction and installation manual provided with the product.
- Misuse or abuse, including failure to properly maintain or service.
- The clearing of blockages in pumps and hoses.
- Damage which occurs during delivery or installation.
- Claims to product surface coating due to liquid or solid spill-overs, accidental damage or damage from cleaning products not recommended by Eurolux.
HOW TO CLAIM OUR WARRANTY
Please refer to our website address below for Everdue in Australia or New
Zealand to register your warranty online. If you are contacting Eurolux
regarding any warranty claims and spare part enquiries, please make sure you
have the following information on hand:
- Product Name/Model Number
- Serial Number
- Purchase Date (as per invoice, or proof or purchase
- Purchased from
- Warranty Registration Number
All Warranty Claims and Spare Parts Inquiries:
In Australia:
Telephone: 1300 355 541
A division of Shriro Australia Pty Ltd
2-34 Davidson Street, Greenacre, NSW 2190
In New Zealand:
Telephone (09) 415 6000
A division of Monaco Corporation
231 Bush Rd, Albany, North Shore City, Auckland, 0632
A division of Shriro Australia Pty Limited
2-34 Davidson Street, Greenacre NSW 2190
AUSTRALIA: 1300 355 541
www.shriro.com.au
NEW ZEALAND: (09) 415 6000
www.monacocorp.co.nz
IM Ref: ERC60X and ERC90X 3/2021/31FC
FOR INDOOR USE ONLY
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>