Technical Specifications

  • Model: VT-82060

  • SKU: 23457

  • Control Mode: Separate Control

  • Input Voltage: DC: 12-24V

  • Output Voltage: DC: 12-24V

  • Output Power: 60W (Max)

  • Output Current: 5A (Max)

  • Power Cable Length: 1.5m

  • Load Power: 12V 60W / 24V 60W

  • Sensor Size:
    Cutout Size [Ø8mm] Bracket Size [25mmx14mmx11mm]

  • Sensing Distance: 0-8cm

  • Function: Open any side of the door, lights
    on; both doors closed, lights off

  • Unit Color: White

  • IP Rating: IP20

  • Compatible LED Strip Lights

Product Usage Instructions

Recessed Mounting

  1. Choose the desired location for installation.
  2. Create a cutout according to the sensor size specifications.
  3. Insert the sensor into the hole.
  4. Turn the power back on and test the sensor.

Surface Mounting

  1. Choose the desired location for installation.
  2. Take the wires through the hole in the bracket.
  3. Fix the sensor on the surface using the bracket.
  4. Turn the power back on and test the sensor.

Wiring Diagram

Directly connect the sensor into the two-pin power socket (L & N) following the provided wiring diagram.

INTRODUCTION & WARRANTY

Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. This product is warranted for manufacturing defects only.

MULTI-LANGUAGE
MANUAL QR CODE
Please scan the QR code to access the manual in multiple languages.

WARNING

  1. Please make sure to turn off the power before starting the installation.
  2. For Indoor Use only

This marking indicates that this product should not be disposed of with other household wastes.
Caution, Risk of electric shock

INSTALLATION INSTRUCTION

RECESSED

  1. Ensure that the power supply is turned off.
  2. Make a hole with a cutout size of Ø8mm in the desired location.
  3. Insert the sensor into the hole.
  4. Turn the power back on & test the sensor

SURFACED

  1. Ensure that the power supply is turned off.
  2. Make a hole with a cutout size of Ø8mm in the desired location.
  3. Take the wires through the hole.
  4. Fix the sensor on the surface.
  5. Turn the power back on & test the sensor.

WIRING DIAGRAM

Directly connect into the two pin power socket (L & N)

V-TAC-VT-82060-Double-Door-Sensor-Switch-fig-4

FAQ

Q: What should I do if I encounter any issues with the product?

A: In case of any query or issue with the product, please contact us at support@v-tac.eu for assistance.

Q: Can this product be used outdoors?

A: No, this product is recommended for indoor use only.

Q: What is the sensing distance of this sensor switch?

A: The sensor has a sensing distance of 0-8cm.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals