AIREMAX APA112C Portable Air Conditioner User Manual

June 4, 2024
AIREMAX

AIREMAX APA112C Portable Air Conditioner User Manual
AIREMAX APA112C Portable Air Conditioner

DESCRIPTION OF UNIT AND PARTS

Product Description

  1. Handle
  2. LED Display
  3. Control Buttons
  4. Air outlet and louvers
  5. Castor
  6. Universal plug fixing holes
  7. Wire winding pillar
  8. Power cord
  9. Drain hole and cover
  10. Filter
  11. Exhaust Connector
  • Air Exhauat Hose

  • Hose Outlet

  • Round Connector

  • Remote Control Batteries 2PCS
    PARTS

Window Panel 3PCS
PARTS

Screw 3PCS

Top Foam Seal
(10 mm x 10 mm x 102 cm)

Bottom Foam Seal
(3 mm x 10 mm x 102 cm)

Suffer Seal
Strip (15 mm x 33 mm x 1200 mm)

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

Your safety and the safety of others are very important. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. We have provided many important safety messages in this manual and on the appliance. Always read and follow all safety messages.

This is the safety alert symbols.

Warning: Failed to follow the instructions could result in death or serious injury.
Caution:  Failed to follow the instructions could result in personal injury or property damage.

  • BE SURE NOT TO DO
  • BE SURE FOLLOW THE INSTRUCTIONS

Warning:

To reduce the risk of explosion, fire, death, electric shock, scalding, or personal injury when using this appliance, please observe the following basic precautions:

Installation and operation
  • Some parts with sharp edges may cause injury. So gloves are highly recommended for unpacking and installing.
  • The portable air conditioner is a heavy object, which needs two or more people to lift and install. Failed to do may result in injury or other accidents.
  • After installation please store the carton, plastic bag, and other packing materials in a safe place to avoid children’s contact. Packing materials can become airtight chambers.
  • Keep the product away from fire. Do not store or use flammable gases or materials near the appliance.
  • In the event of a gas leak (propane gas, LP gas, etc.) do not operate this or any other appliance. Open a window or door to ventilate the area immediately.
  • Do not repair or replace any part of the appliance. All repairs and servicing must be performed by qualified service personnel.
  • Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled or has missing or broken parts, including a damaged cord or plug.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by the person responsible for their safety.
  • Do not use heating equipment near the appliance.
  • Only use the appliance in an upright position. Make sure the angle of inclination<10°. Always place the appliance on a stable, flat, level surface to prevent the air conditioner from overturning.
  • Read all instructions before using the appliance and save these instructions.
  • Before cleaning or maintenance operations, always unplug the unit from the outlet.
  • Power on this appliance in strict accordance with ELECTRICAL SAFETY guide.
  • Keep the air inlet and outlet free of obstructions.
  • Do not use this unit in places exposed to
  • If the product has been submerged, contact the JHS customer service
  • center for instructions before resuming use.
  • If the product makes a strange noise or emits a smell or smoke, pull the power plug out and contact the JHS customer service center.
  • Do not place heavy objects (>3KG) on top direct sunlight, wind or rain. of the air conditioner.

Warning:

READ ALL INSTRUCTIONS BEFORE USE

ELECTRICAL SAFETY (High voltage appliance)
  • If the power cable is damaged, it must be replaced by the manufacturer or an authorized technical service center in order to avoid all risk.
    During the installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
    Do not damage, alter, excessively bend, twist, pull or heat the power cord.
    Do not modify or extend the power cor.
    Safety Instruction

  • Do not cover the power cord with a rug or carpeting.
    Do not rest hot or heavy objects on the appliance and power cable.

  • Always plug into a fixed 115V AC ground outlet.
    Push the power plug all the way into the wall outlet so that it is not loose.
    Always grip the plug firmly and pull straig ht out from the outlet when taking it out.
    Never unplug the appliance by pulling on the power cord.
    Never use the appliance if the outlet is damaged or loose.
    Safety Instruction

  • Do not use multiple-outlet power strip or extension cord with this appliance.
    Do not use an AC plug adapter with this appliance.
    Do not cut or remove the third (ground) prong from the power cord.
    Safety Instruction

  • Always finish the test of LCDI plug before use air conditioner:
    LCD INTEGRATED CIRCUIT BREAKER:
    CIRCUIT BREAKER
    Follow 4 steps on the LCD I plug ca se, if the TEST button does not cause the circuit breaker trip or the RESET button will not stay engaged, unplug the air conditioner immediately and contact JHS customer service center.
    GROUNDING METHOD
    GROUNDING METHOD
    Ensure proper ground exists before use.

  • Always unplug the unit from the outlet before cleaning or maintenance operations.
    Always unplug the unit if you will not use it for a long time.

INSTALLATION INSTRUCTIONS

SUGGESTED TOOLS FOR INSTALLATION

  • Screwdrivers (medium size)
  • Tape measure or ruler
  • Knife or scissors
  • Saw (In the event that the window kit needs to be cut down in size because the window is too narrow for direct installation)

SELECTION OF INSTALLATION LOCATION

  1. Place the unit near a window.
  2. For be st performance, allow at least 20 inch (50cm) of air space on all sides of the unit for good air circulation.

ATTACHING EXHAUST HOSE

Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fit on both ends.
The supplied exhaust hose can be extended to 59inch max.
ATTACHING EXHAUST HOSE

(Stretch both ends of the exhaust hose out for 10-15cm.)

Push the plastic lose into the hose connector on the back of the unit.
Keep gently and horizontal to avoid getting stuck.

Note:
The length of the exhaust hose is specially designed for the unit. Da not replace or extend it with another hose as this could cause malfunction. Do not block airflow around the air conditioner. The exhaust hose should be free of any obstructions.
A bent hose will block exhaust air and cause the unit to malfunction or shut off.
Attachments

WINDOW KIT INSTALLATION

NOTE: Depending on the size of your window opening, use the main panel and one or both of the extension panels.

  1. Open the window and place the main window panel into the window.
    NOTE : The window assembly is designed to accommodate either a vertical slide or horizontal slide window.
    Vertical Slide Window:
    WINDOW KIT
    Horizontal Slide Window:
    WINDOW KIT

  2. Adjust the extension panel(s) to the width or height of the window as shown.
    NOTE: Some window installations may require the extension panels to be trimmed.

  3. Depending on the number of extension panels used, use two or three flat screws to secure the extension panel(s) to the main panel. Install front the back.
    WINDOW KIT

CONNECT HOSE TO WINDOW KIT

The air exhaust hose must be installed or removed from the portable air conditioner in accordance with the way it is being used:

  1. Hold the main window panel so that the L-shaped edges of the panel are facing you.
    Hose Connection

  2. Align the exhaust nozzle with the slots in the opening, and then insert and slide the nozzle to access the hole from the the back of the main window panel.
    A. Main Window Panel
    B. Hose Outlet
    Hose Connection

  3. Turn the main window panel over, so that the nozzle is away from you. Insert a flat screw through the hole to fasten the window panel to the adapter.
    A Flat Screw
    Hose Connection

  4. Grasp both ends of the exhaust hose and gently pull to expand the hose.
    NOTE: Do not attach additional hoses to extend the length. This would decrease cooling efficiency and may damage the air conditioner.

  5. Using a counterclockwise motion, attach the open end of the exhaust hose to the exhaust nozzle.
    Hose Connection

Connect hose to air conditioner

IMPORTANT: When connecting the hose, the air conditioner must be close enough to the window that you will not dislodge the window seal plate. Once the hose is connected, move the air conditioner 20” (51 cm) from the wall.

  1. Extend the flexible exhaust hose to reach out to the unit.
  2. Aim the opening of the hose to the air exhaust outlet and push it hard straight into the outlet until it clicks.
    Connecting hose

OPERATION

INSERTING BATTERIES IN THE REMOTE

  1. Press and glide the battery cover on the rear of the remote, remove the cover.
  2. Insert two new R03 “AAA” 1.5V batteries into the battery compartment. Make sure the polarity is correct.
  3. Battery is not included in the package because of transportation safety.
    INSERTING BATTERIES

NOTE:

  • Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zins) or rechargeable batteries.
  • If the remote control is not be used for a certain length of time, remove the batteries (Batteries may explode or leak).
  • If the remote control unit is rep/aced or discarded, the batteries must be removed and disposed of in accordance with current legislation as they are harmful to the environment.

CONTROL PANEL AND LCD DISPLAY

CONTROL PANEL

| On/OP button| | Mode button| | Up button
---|---|---|---|---|---
| Timer button| | Fan speed button| |

Down button

| Timer indicator| | High speed indicator| | Low speed indicator
| Water-full indicator| | Fan mode indicator| |

Dehumidify mode indicator

| Cool mode indicator| | Sleep mode indicator| | Remote control signal receiving window
| LED display window| | Operation indicator| |

Celsius/ Fahrenheit temperature indicator

A. Timer Button
Program a time from (1-hour to 24-hours) for the air conditioner to turn Off or On. When a Time Delay is programmed, the Timer indicator light will illuminate.

While the air conditioner is operating:

  1. Press the Timer button.
  2. Press the Up/Down arrow buttons to select the number of hours you want the air conditioner to continue to operate before turning Off.
    NOTE: Wait approximately 5 seconds for the Turn-Off time to be saved.

While the air conditioner is off:

  1. Press the Timer button.
  2. Press the Up/Down arrow buttons to select the number of hours you want the air conditioner to remain off before turning On.

NOTE: Wait approximately 5 seconds for the Turn-On time to be saved. To cancel the timer:

  • Press the Timer button once, the hours remaining will flash, press the timer button again and the timer will be canceled.

B. Fan Speed Button
The fan speed can be adjusted from Low speed to High speed when the air conditioner is either in Cool or Fan mode.
NOTE: The fan speed cannot be adjusted when the unit is in DEHUM mode.

  • Press the Fan Speed button to toggle among the two speeds. The corresponding fan speed indicator will illuminate.

C. Up and Down Arrow Buttons
Adjusts the Temperature or Hours in Time Delay.

To Set the Temperature:
The temperature can be set between 62°F and 86o F (17oC and 30° C) when the air conditioner is in Cool mode.

  1. Press the Mode button until the Cool mode is selected.
  2. Press the Up Arrow or Down Arrow buttons to select the Temperature.
    NOTE: The temperature cannot be set when the air conditioner is in either Fan or Dry mode.

D. Mode Button
Press the Mode button to toggle among the operating options. The corresponding indicator will illuminate:

  • Cool — Cools the room to the set temperature
  • Dehum — Reduces the humidity in the room
  • Fan — Circulates the air in the room without cooling

E. Power Button
Turns ON/OFF power to the air conditioner.
NOTE: Turning off power by pressing the Power buttondoes NOT disconnect the appliance from the power supply.

  • Press the Power button. The Power indicator will illuminate.

REMOTE CONTROL

  1. Insert the two batteries (provided).
  2. Aim the remote control at the signal receiver on the control panel to operate the air conditioner.

F. Sleep Button
Increases the set temperature by 2°F (1°C) after 2-hours, and then increases the temperature by an additional 2 F (1°C) after another 2-hours.
NOTE: The fan will operate at Low speed dnd cannot be adjusted while in Sleep mode. Press the Sleep button to enter Sleep mode. The Sleep indicator will illuminate.

To Cancel Sleep Mode:

  • Press the Sleep button or the Mode button (Cool, Fan or Dry) on the remote control.
    G- °C/°F Button

  • Press the oC/°F button to toggle between displaying the temperature in degrees Fahrenheit or degrees Celsius. The corresponding indicator will illuminate.

WATER DRAINAGE

This portable air conditioner has a self-evaporative system. The condensed water will be recycled to the working compressor and evaporator, most of the water will be evaporated.
This work procedure can not only improve cooling efficiency but also save energy for all customers. Since most of the condensed water will be used to aid the compressor, there is no need of drain hose in general using environment.

If you use the portable air conditioner for cooling or dehumidifying in a high humidity situation (Relative humidity >85%, like New Orleans, Louisiana, Jacksonville, Florida, Houston),  the collected excess water will need to be drained through a drain plug in the bottom of the unit. With a full reservoir, the compressor will stop working.

Manual Drainage

  1. Unscrew the water stopper and unplug the rubber plug
  2. Put a tray below the water outlet at the back of the unit.

Continuous Drainage
Continuous Drainage

  1. Unscrew the water stopper and unplug the rubber plug
  2. Connect the drainage pipe to the water container or drainage ditch to outdoor. The drainage pipe is purchased by users , pipe diameter is φ13mm

PROTECTION FUNCTION OF PORTABLE AIR CONDITIONER

  1. Frost Protection Function:
    In a cold environment, if the temperature of the EVA pipe sensor is too low, the machine will automatically enter.protection status; if the temperature of the EVA pipe sensor rises to a certain temperature ( 8 °C), it can automatically revert to normal operation.

  2. Overflow Protection Function:
    When water in the water pan exceeds the warning level, the machine will automatically sound an alarm and stop working, and the W.F indicator will flash. At this time, you need to drain the water After the water is emptied, the unit will work normal again.

  3. Protection Function of the Compressor:
    To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor is turned off.

CARE AND CLEANING

Before cleaning or maintenance, turn the appliance off by pressing the button on the control panel or button on the remote control. Wait for 5-10 minutes then unplug from the electrical outlet.

CLEANING THE CASE

  • You should clean the appliance with a slightly damp cloth then dry with a dry cloth.
  • Never wash the air conditioner with water. It could be dangerous because of short circuit or fire.
  • Never use petrol, alcohol or solvents to clean the appliance.
  • Never spray insecticide liquids or similar.

CLEANING THE FILTER

If the air filter is clogged with dust, the effectiveness of the air conditioning will be reduced. To keep your air conditioner working efficiently, you should clean the evaporator filter every two weeks of operation.

  1. Unplug or disconnect power.

  2. Pull on the tabs to slide out the filters from the back of the air conditioner.
    NOTE: The secondary filters are accessible once the main filters are removed.

  3. Wash or vacuum the dust from the air filters.
    NOTE: If washed, gently shake the filter to remove the excess water and dust particles trapped in the filter.

  4. Reinstall the filters.

  5. Plug in or reconnect power.
    Filter Cleaning

START – END OF SEASON OPERATIONS

END OF SEASON OPERATIONS

  1. Remove the cap, run off all water left into the basin. When all the water has been drained, put the cap back in place.
  2. Clean the filter and dry thoroughly before putting back.
  3. Remove the batteries from the remote.
  4. Store the unit in a cool, dry room, away from direct sunlight, extreme temperatures, and excessive dust. Keep it out of the reach of children.

START OF NEW SEASON CHECKS

  1. Make sure the power cable and plug are undamaged.
  2. Follow the installation instructions precisely, install the unit again.
  3. Place new batteries into remote.

TROUBLESHOOTING

BEFORE YOU ASK FOR SERVICE

  • Check to make sure that the air conditioner is plugged in securely. If it is not, remove the plug from the outlet, wait 10 seconds and plug it in again firmly.
  • Check the blown circuit fuse or the tripped main circuit breaker. If they work properly, test the outlet with another appliance.

Troubleshoot your problem by using the chart below. This list includes common occurrences that are not the result of a defect in factory workmanship or materials.
If the air conditioner still does not work properly, contact the customer service center. Customers must never troubleshoot internal components.

Trouble

| Possible Cause|

Possible Remedy

---|---|---
Unit does not start when pressing ON/OFF button.| A. Water-full indicator flash in the LED display.
B. Room temperature is lower than the set temperature (cooling mode).
C. The ambient temperature is too low. D. In dehumidifying mode, ambient temperature is low.| A. Drain the water in the bottom tray.
B. Reset the temperature.
C. Recommend to use the unit in at the temperature of 7-35°C (44-95 °F ) for cooling mode.
D. Recommend to use the unit in at the temperature of 17-35 °C (62-95 °F) for dehumidifying mode.
The cooling effect is not good| A. There is direct sunlight. B. Doors or windows are open.
C. There are other sources of heat in cooling mode.
D. The air filter is dirty. E. The air inlet or outlet is blocked.| A. Pull the curtain.
B. Make sure all the windows and doors are closed.
C. Remove the heat sources if possible.
D. Clean the air filter.
E. Make sure the exhaust hose is assembled properly.
Big noise or vibration.| A. The surface is not level or not flat enough.| A. Put the air conditioner on a flat and hard place.
The remote control does not work.| A. The distance between the machine and the remote control is too far.
B. The remote control is not aligned with the direction of the remote control receiver.
C. Batteries are dead.| A. Let the remote control get close to the air conditioning
<5M.
B. Make sure that the remote control directly faces to the direction of the remote control >B. Make sure that the remote control directly faces to the direction of the remote control

C.
Replace batteries.

WARRANTY

PORTABLE AIR CONDITIONER LIMITED WARRANTY

Any repair, replacement, or warranty service, and all questions about this product should be directed to customer service center.

The warranty commences the day the product is purchased and covers up to a period of 1 year (12 months) for parts (manufacturing defects only).

Exclusions: This warranty does not applly to the below:

If the appearance or exterior of the product h as been damaged or defaced, altered or modified in design or construction.

  • If there is damaged due to power line surge, user damage to the AC power cord or connection to an improper voltage source.
  • If the damage is due to general misuse, accidents.
  • Damages caused by unauthorized repair and using of non-genuine parts.
  • On products that have been purchased as refurbished, like new, second hand.
  • Unit used in a commercial or rental setting.
  • Damages caused by improper installations.

Email: [email protected];
[email protected]
Website: www.nepousa.com;
www.airemaxusa.com

All the technical and specific parameters, pleas e refer to product nameplate.
Due to continuous improvement, we reserve the right to change some design without timely notice.

Electrical products should be properly disposed.
Please recycle where facilities exist.
Check with your local authority or retailer for recycling.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AIREMAX User Manuals

Related Manuals