JINHZIXIU Rolling Door Opener User Manual
- July 20, 2024
- JINHZIXIU
Table of Contents
- JINHZIXIU Rolling Door Opener
- Product Information
- Product Usage Instructions
- Safety Precautions
- Features
- Definition of Control Board
- Definition of Control Board
- Packing List
- Install Sequence
- Installation
- Checking door closing force
- TECHNICAL SPECIFICATIONS
- Malfunctions AND SOLUTIONS
- FAQ
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
JINHZIXIU Rolling Door Opener
Product Information
Specifications
- Automatic Obstacle Detection
- Photo Beam Protection System
- Remote Control with Hopping Code
- Electronic Travel
- Soft Start and Soft Stop
- Automatic Close Feature
Product Usage Instructions
Safety Precautions
- It is strongly recommended that photo beam sensor devices be used for added protection.
- Always keep the moving door in sight while operating the opener to avoid personal injury or equipment damage.
- Do not operate the opener when children are nearby. Children should be supervised to prevent accidents.
Installation Sequence
- Remove or unlock the rolling door and mechanical devices before installation.
- Ensure the rolling door is well-balanced before proceeding.
- Connect the power supply to a standard 220V socket with proper grounding.
- Install any wall switches or transmitters that are out of reach of children.
- Test and set the automatic obstacle detection function according to the instructions.
Operation
- Make sure the rolling garage door is completely open before entering or exiting.
- Ensure the door is completely closed when leaving.
Main Technical Specifications
- Power Supply: Standard 220V
- Operation: Remote Control with Hopping Code
- Safety Features: Automatic Obstacle Detection, Photo Beam Protection System
- Motion: Electronic Travel with Soft Start and Soft Stop
- Additional: Automatic Close Feature
Safety Precautions
- Please read the following safety precautions carefully
- For much protection, it is strongly recommended to use photo beam sensor devices, only with a bit extra cost.
- While operating the rolling door opener, always keep the moving door in sight, and ensure that nobody, no vehicle below the moving door. Ignorance of this warning, severe personal injury or equipment damage may happen.
- Please do not operate the opener while a kid or someone standing by the door. During the process of operating the opener, in the case of a kid nearby, the kids should be taken after by his/her supervisor. Ignorance of this warning, severe personal injury or equipment damage may happen.
- Children are not allowed to operate the door opener in case of severe personal injury.
- Make sure the automatic obstacle detection function performs well. Please test and set this function according to the instructions strictly, and conduct a regular test. If needed, necessary adjustments should be made.
- In the case that people, cars, or other objectives are below the rolling door, please do not pull the clutch and operate it manually.
- In the case of installing a wall switch or wall transmitter, the location of the wall switch or wall transmitter should be beyond the reach of children.
- The rolling door must be well-balanced. In the case of sticking or bending, it is required to ask qualified installation workers to check and repair. Do not repair the door or the door opener arbitrarily, since that there is powerful spring inside the door, which may cause physical injury and property loss.
- Before installation of door opener, please remove or unlock the rolling door and mechanical devices.
- The power supply for the rolling door opener must be connected to standard 220V socket by professionals, and with sound grounding.
- The power must be cut off whenever mending the opener or opening its cover. The door opener should be mended by professionals.
- Hands and loose clothes are prohibited approaching the door or door opener no matter when.
- In the case of automatic closing mode, the photoelectric protection device must be installed correctly. The photoelectric protection device must be tested regularly. While using the automatic closing function, the above safety code should be obeyed strictly.
- In case that the door can rebound while encountering obstacles to open mode, it should be ensured the obstacle reverse function be adjusted properly during the installation of door opener. The debugging of obstacle reverse must be carried out repeatedly, if necessary, adjustments may be made.
- Make sure that the rolling garage door is completely open before entering and exiting.
- Make sure the rolling garage door is completely closed while leaving.
Features
ERDO are endowed with quite a few new features. The components and materials used in the control board are of the latest technology and best quality. Following are the main features:
Easy Operation
Press the buttons of the handheld transmitter of rolling door opener, the door
will open or close automatically. While the door is closing, simply press the
button, then the door will stop moving down and open reversely. When opening,
simply press the button, then the door will stop moving. Also, the above
function can be achieved by wall-mounted transmitter or wall switch (optional)
or the button on the cap of main control board.
Encryption Coding
Every time the remote control transmitter works, the encryption coding will
change once. The possible password combination can be as much as 4.29 billion,
which enhances security tremendously and makes “code-pirating” impossible.
Intelligent Barrier Detection System
While the door is doing a closing cycle and hitting an obstacle or be
restricted in some manner, the door can reverse automatically. Likewise, while
the door is opening and encountering an obstacle, the door will close
automatically. The force of resistance should be adjusted via the
potentiometer of the main control board during the initial installation. The
force of resistance should be checked at least once monthly, more details
please refer to installation instructions.
Security Code Storage of Transmitter
The latest advanced technology is applied in encryption coding stored in
transmitter. Up to 30 different code of transmitter can be stored. To store
any new code, simply press the CODE button on the opener and press the
transmitter button twice, the transmitter code will be stored immediately. The
code can be deleted at any time.
Automatic Courtesy Lights
The courtesy light on the Opener turns on automatically whenever the door is
activated to do an opening or a closing cycle. When the door stops moving, the
courtesy light will stay on for approximately three minutes and then turn off
automatically.
Automatic Closing Mode
The Opener can be programmed to automatic closing mode. The function of
automatic delay closing can be opted via the jumper on the opener. If this
mode is selected, a photo beam sensor must be installed.
Multiple Protection
Overtime protection; Low voltage protection; Rotating speed fluctuation
protection.
Manual Operation
The Opener is equipped with a manual disengaging system. If the power to the
Opener ceases for some reason, the door can be shifted to manual mode by
pulling down the string handle, in this situation manual opening and closing
are allowed. When the power is restored, pull down the string handle then the
opener is back to the automatic mode. (The above situation is suitable for
single clutch-ERD1007; if ERD1006—double clutches, pulling down the red string
for manual operation, pulling down the green one for automatic operation
mode). Soft Start Soft Stop This function can abate the impact on the door
caused by opening and closing the door effectively.
Photo Beam Sensor(optional)
The Opener has an input for a photo beam sensor, which is to be connected for
extra safety protection. The photo beam sensor must be installed if auto
closing mode is chosen.\
Definition of Control Board
-
Function Setting Button (Set)
During installation, please set the upper and lower limit, left and right installation, operating power, and auto-closing time. -
Remote control learn button (Code)
Add or delete the code of the transmitter. -
Increase (Open) Button (▲)
During installation, please set the button value be Increase or Open. -
Decrease (Close) Button (▼)
During installation, please set the button value to Decrease or Close. -
Open/Stop/Close Button (OSC)
The opener operates in the cycle of Open—–Stop——–Close—–Stop. -
Digital Display Menu
During the installation and use, the digital menu displays current value and status. -
Courtesy Light
Illumination and Fault Indicator. -
Interface to Outside Wall Switch
This interface is available for wall switches or other control devices, the opener operates in the manner of Open—–Stop—-Close—-Stop. -
Connector for Photo Beam Sensor
DC 24V Normally Closed Photo Beam Sensor can be connected to this connector. -
Input for Encoder Signal
To connect the inside encoder. -
Motor Power Output
Connect to inside DC motor -
Backup Battery Input
Can connect DC 24V back up battery. -
Transformer Power Input
Input AC 24V transformer power. -
24V Power Supply Fuse
T15A/250V Fuse, in the case of burning out, please replace it with the same model. -
Manual Clutch Handle
When power off, pull down the clutch handle to shift to manual operation mode; pulling down again to automatic operation mode.
Restrictions on Use
- In the case of power off and manual mode is applied, OPEN/CLOSE limit should not exceed 20cm of the learning time, otherwise malfunction may occur when power on.
- When the door stays close to the top but not limit top, press OPEN button, the door will not open; when the door stays near the bottom but not limit bottom, press CLOSE button, the door will not close.
Definition of Control Board
- Function setting button
- Remote control learn button
- Up (Open) button
- Down (Close) button
- Open/Close/Stop button
- Digital display tube
- Courtesy light
- Interface to outside wall switch
- Interface to outside photo beam sensor
- Input for encoder signal
- Output for motor power
- Interface to outside backup battery
- Input for transformer power
- 24V power fuse
- Manual/Automatic clutch handle
Packing List
Install Sequence
Installation
Side Room Requirements
Picture 1 shows the minimum side room that is required: The distance between
the edge of the door curtain and the inside of the bracket should be 85mm.;
the distance between the edge of the door curtain and the outside of the
bracket should be 135mm.
Picture 2 demonstrates the recommended side room: The distance between the edge of the door curtain and the inside of the bracket should be more than 110mm; the distance between the edge of the door curtain and the outside of the bracket should be more than 160mm.
Check the door carefully
Before the installation of the door opener, please check the door opener carefully, and ensure the rolling door is well-balanced and in good condition. Therefore, the door can move smoothly in the guide rail and can stay at around 90cm—120cm above the ground. The force of door lifting or downing should not be over 20kg.
Fixing the door weight balancing bars
Move the door manually to half-open position, and place the weight balancing bars equally apart on the door bottom, then fix them with the fasteners provided. (see picture 3 ) Check the door again, if the door moves heavily in the guide rail, it may require extra tension to be added to the door springs. In this case, please refer to the door installation instructions from the door manufacturer on how to adjust the door spring.
Door opener on the right or left
The ready opener is set to be installed on the right side, in the case of left side installation, please reset the function setting button from to Operating as follows, see picture 4:After the power is on, press the function setting button (SET) for 4 seconds and then release, when the digital display tube shows , press the SET button again, if the digital display tube shows , which indicates right side installation, press UP (▲) or DOWN (▼) button, when the digital display tube shows , that means left-side installation, press SET once more, then check and store.
Door Opener Installation (Right side installation)
There are several methods of door opener installation, following one of them
is described.
First of all, make sure enough room for driver installation, the distance
between the end of the door shaft and the wall should be 135mm at least
(Attention: this method only suitable for right side installation). For
specific installation, please refer to picture 5, picture 6, picture 7.
- Check carefully to see whether the U bolt on the left side is tightly fixed on the door shaft.
- Lift up the door, tie up the door firmly with a rope in middle position.
- Use support to sustain the right part of the door curtain. (Attention: Something soft should be padded under the support in case of door surface damage.)Warning: During installation, children are forbidden to be around, if ignore this warning, severe personal injury or property loss may be caused.
- Check if step 3 is finished, then release the U bolt on the right side of the door and take it away carefully.
- After right the door support removed from the wall, please make sure that the support of the door is safe and reliable.
- Take out the opener from the package, manually turn the forks on the opener to make the gear spin, if the gear do not spin, it is considered as auto mode. At this time, please draw the clutch handle (if ERD1006 draw red clutch) manually and softly to take part the driving gear and the motor to shift to manual operation mode, in this case the gear can spin freely.
- Push the opener along the door shaft to the plastic plate, and make sure that the double forks of the gear is in the narrowest spoke and stretch into the plastic plate.
- Reinstall the right side support, if special case, the support frame should be relocated, and retighten the U bolt, remove the support below the door and the bundled rope.
- Move the door up and down with the hands to see if the door operates well. The door should move smoothly and can not be touched.
Please fix the door curtain on the drum-shape plastic wheel
The door curtain must be fixed firmly on the drum-shape plastic wheel.
- Close the door completely, make marks on the both sides towards the plastic wheel.
- Please find the marks when door is slightly open, use two self-tapping screws on every side of the door curtain on plastic wheel. Attention: the position of the two screws should be in the 90 degree direction, see picture 8.
Set up and down travel position
-
In the case of right side installation: please move the door to the middle position manually, and draw the clutch handle (if ERD1006 draw the green clutch handle) once to make sure the door opener is in auto mode.
-
Put on the power plug, the digital display tube changes from to . Finally see picture 9.
-
Press SET button for 4 seconds, when the display on display tube from ‘to and flicker, then hands off, press the UP button once, the digttal display tube tum •a• and flicker, then press SET one time and the digital display tube shows , which means setting the proper position for door dosing.
-
Press CLOSE uninterrupted and the digital display tube shows and flicker, meanwhile the door is dosing.
(When hands off, the door will stop closing; if the door opens at this time, that means the wrong setting of left side installation and right side installation. In this case, the opener should be powered off and then power on again. Please refer to 3.1 and tum· into . After the door is totally closed, release CLOSE , W the door is not in proper position, please press CLOSE or OPEN once, to make the door dose in the ideal place, then press SET once again, the digital display tube turns which means to set the proper position after door totally opened. -
Press uninterrupted, the digital display tube shows ‘ then start to flicker, at the same time the door opens, when the door is totally open, release , if the door does not stop at an ideal position, please press or once to make the door stay at the ideal place. Repress SET once, the door will close immediately and stop at the right dosed position. Finally, digital display tube shows and finish door travel position settings.
Attention: After the ideal place for door closing and before setting the ideal position for door opening, the position for the opening door ( height of opening door) should be within 1–3 meters; if the opening door height is beyond 1-3 meters, when you press SET, the door will not dose automatically, at this time the courtesy light keeps flickering for a while to show that the wrong position and new settings should be done.
Attention: After the ideal place for door closing and before setting the ideal position for door opening, the position for opening door ( height of opening door) stay should be within 1—3 meters; if the opening door height is beyond 1—3 meters, when you press SET, the door will not close automatically, at this time the courtesy light keep flickering for a while to show that the wrong position and new settings should be done.
Setting of left side installation: the same as the right side installation, please refer to 6.1.
- Please refer to 3.1 and change to Here after all the setting are the same as right side installation, please refer to 6.1.
Set Operating Force
-
Set force for opening door operation ( class 1-9, see picture 10)
-
Press SET for four seconds, the digital display tube changes from to and flickers; then release, then press twice, the digital display tube shows and flickers; at this moment press SET once, the digital display tube shows , which means opening door operation force Class 9 (Factory Default).
-
Press once, the digital display tube
shows , which means lowering one class of the force for opening door operation. Press the digital display tube shows which indicates increase one class of the force for opening door operation. After setting the proper class, press SET once again, the digital display tube shows , and store new setting value and then return to standby mode. -
Set force for closing door operation ( Class 1-9, see picture 11)
-
Press SET for four seconds, the digital display tube changes from to and flickers, then release. Press three times, the digital display tube shows “B” and flickers, at this moment press SET one time, the digital display tube shows , which means closing door operation force class 5 (Factory Default).
-
Press one time, the digital display tube shows , which means the door closing operation force decreases one class; if press once, the digital display tube shows “f this means the door closing operation force increases one class. After setting the proper class, press SET once again, the digital display tube shows and store new setting value and then return to standby mode.
Checking door closing force
- Press the OPEN button until the door up to the highest position, see picture 12.
- Place a 100mm x 50mm block below the door, see picture 13.
- Press CLOSE to close the door until the door hits the block and begins moving reversely until the door is totally open.
Checking door opening force
- Remove the block, and press CLOSE until the door is completely closed, see picture 12.
- Press OPEN to open the door until the door moves midway, use hands to firmly grasp the door bottom, the door should stop moving up.
In the case that the door does not backtrack easily when closing, or in the case that the door stops hard when opening, both these two cases demonstrate that the force is not well adjusted. Then please follow 7.1, 7.2, 7.3, and 7.4 to readjust.
Warning:
When a door closes, if there is something wrong with the torque testing
system, please adjust and retest until everything meets the requirements that
the door can be operated.
Setting of Remote Control Transmitter
-
Learning a transmitter, see picture 14.
-
Press CODE once, the digital display tube changes from to and enter into the learning condition, then press one of the buttons twice, and the digital display tube flickers quickly then turns into .
, and the code is learned. -
Press the CODE to check if it can control the relevant door operation. This learning method can be applied into other transmitter learning. transmitters, no new transmitter can be learned any more.
-
Delete of remote control transmitters
-
Press CODE uninterrupted until the digital display tube changes from to and flickers, then enter into delete transmitter condition. After eight seconds, the digital display tube shows and flickers, then shows at this moment release the button and finish deleting transmitters. If release CODE within 8 seconds, itc comes into the learning condition.
Courtesy Light Auto Turn-off Time
the auto turn off time is three minutes
Auto Close Set
- Auto close time setting (class 0, 1—9, see picture 17)
- Press SET for four seconds, the digital display tube changes from to and flickers, at this moment release SET button. Press four times, the digital display tube shows and flickers, at this moment press SET once, digital display tube shows , which indicates auto closing class 0 (Factory default, in other words, auto close function is closed.)
- Press once, the digital display tube shows, which indicates auto close time increases one class (one class means one minute); if press once, the digital display shows , which means the auto close time decreases one class; After setting the proper class, please press SET once again. The digital display tube shows , restores new setting value, and then return to standby mode.
Only when the door open to the limit and auto close time is set, the auto close timer begins counting. If Photo beam sensor is blocked, the door will keep open. The door will reopen when obstructed or the photo beam sensor is blocked during closed.
Photo Beam Sensor (Optional)
-
1. A normal closed photo beam sensor is recommended to install at a suitable place beside the door and connect the wires to CON2 PCB board. ( See picture 18)
Anything about the connection of circuit diagram photo bean sensor, please refer to of the photo beam sensor manual.
Warning: When use auto close and photo beam sensor, there should not be obstacles or people around the door. The installation position and method should be proper, or the protection function will not be effective.
TECHNICAL SPECIFICATIONS
Malfunctions AND SOLUTIONS
Installation
FAQ
Common Malfunction and Maintenance Methods
If you encounter any issues with the rolling door opener, refer to the user manual for troubleshooting steps. For maintenance or repairs, always consult professionals to avoid injuries or damages.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>