ICON Truflo PRD Series Digital LED Pressure Transmitter Switch User Manual

July 16, 2024
Icon

ICON Truflo PRD Series Digital LED Pressure Transmitter Switch

Product Information

Specifications

General:

  • Pressure Sensor Measured Fluids
  • Applied Temperature
  • Over Pressure Burst Pressure
  • Pressure Units Display Material
  • Thermal Drift Mounting
  • Protection Class Process Connection

Electrical:

  • Operating Voltage Current Consumption

Output:

  • Transmitter Output Relay Outputs
  • Current Output Relay Contact Rated

Performance:

  • Accuracy Repeatability

Standards and Approvals:

  • CE | FCC RoHS Compliant

Product Usage Instructions

Safety Information:

  • De-pressurize and vent the system before installation or removal.
  • Confirm chemical compatibility before use.
  • DO NOT exceed maximum temperature or pressure specifications.
  • ALWAYS wear safety goggles or face shields during installation and service.
  • DO NOT alter product construction.

Installation Instructions:

  • Do not tighten by grasping the transmitter case as this may cause damage.
  • Always pressure test connections for leaks with water before use of chemical service.
  • Ensure the correct transmitter pressure range and materials of construction are selected.

Personal Protective Equipment (PPE):
Always utilize appropriate PPE during the installation and service of the product.

Programming:

  • Press and Hold SET for 5 seconds to lock the setting.
  • Press SET X 2 for pressure unit selection.

Display Features:

  • Alarm Status: No Alarm (Green), Alarm 1 or Alarm 2 ON (Red).
  • Relay Set Points: Press SET for 5 seconds.

FAQ

  • Q: How do I select the correct pressure range and materials?
    A: Always refer to the product specifications and consult the user manual for guidance on selecting the appropriate settings and materials.

  • Q: What should I do if the display shows an upset condition change?
    A: Check the installation, pressure levels, and connections to ensure proper functioning. If issues persist, contact customer support for assistance.

Read the user’s manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice.

Safety Information

  • De-pressurize and vent the system before installation or removal
  • Confirm chemical compatibility before use
  • DO NOT exceed maximum temperature or pressure specifications
  • ALWAYS wear safety goggles or face-shield during installation and service
  • DO NOT alter product construction

Warning | Caution | Danger
Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death.

Note | Technical Notes
Highlights additional information or detailed procedure.

WARNING

  • Please ensure that the Instruments are not to be subject to water hammer or pressure spikes! Always Pressure the Test System with H2O Before the Initial Start-Up
    Before installation be certain the appropriate instrument has been selected considering operating pressure, full-scale pressure, wetted material requirements, media compatibility, operating temperature, vibration, pulsation, desired accuracy, and any other instrument component related to the service application including the potential need for protective attachments and/or special installation requirements. Failure to do so could result in equipment damage, failure, and/or personal injury. Ensure only qualified personnel personnel are permitted to install and maintain this instrument.

  • Pressurize System Warning
    The sensor may be under pressure, take caution to vent the system before installation or removal. Failure to do so may result in equipment damage and/or serious injury.

  • Please Ensure Full Pipe
    PRD Series can be installed in a horizontal or vertical direction.

Installation Instructions
Do not tighten by grasping the transmitter case as this may cause damage. Always pressure test connections for leaks with water before use of chemical service. The user shall ensure that the correct transmitter pressure range and the correct materials of construction are selected.

  • Personal Protective Equipment (PPE)
    Always utilize the most appropriate PPE during the installation and service of Truflo products.

  • Pressurized System Warning
    The sensor may be under pressure. Take caution to vent the system before installation or removal. Failure to do so may result in equipment damage and serious injury.

Technical Specifications

General

Pressure Sensor| Ceramic ( AL2O3 96% ) | SS316L
Measured Fluids| H2O | Chemical Liquids | Gases
Applied Temperature| -40°F – 257°F | -40°C – 125°C
Over Pressure| 200% of FS min.
Burst Pressure| 300% of FS min.
Pressure Units| Psi | Bar | KPa | Kg/cm2
Display| 0~999 | Green | Red
Material| PP | PVDF | SS316L
Thermal Drift| SS316L : ± 0.05% FS/°C | Ceramic : ± 0.1% FS/°C
Mounting| Direct Mount | Bottom Connection
Protection Class| IP66 | NEMA 4X
Process Connection| ½” MNPT / FNPT (PP | PVDF) | ¼” MNPT (SS316L)
Electrical
Operating Voltage| 10-30VDC
Current Consumption| 50mA max.
Output
Transmitter Output| 4-20mA | 0-10V*
Relay Outputs| (2) 1 Amp Relays or 2 NPN | 2 PNP
Current Output| 150mA max.
Relay Contact Rated| 1A | 30 VDC max.
Performance
Accuracy| ****

Repeatability| ****

Standards and Approvals
CE | FCC
RoHS Compliant

Product Introduction

Display Features

Alarm Status| No Alarm| Alarm 1 | Alarm 2 ON
---|---|---
Display| Green| Red
Relay Set Points| Press| |  5 seconds
---|---|---|---
Function Setting| Press|  5 seconds
Press X 2 to Load the Setting Value and proceed to the next setting
Press and Hold the key, while tapping the key to DECREASE the Setting Value, and Press the key to INCREASE the Setting Value.|

Programming

  • Select/Save/Continue
  • Change Digit Value

Alarm Settings

  • Select/Save/Continue
  • Change Digit Value

Alarm Mode Settings

Wiring Diagram

M12 Wiring

Pin| Color| Description
1| Brown| + 10-30 VDC
2| White| Relay 2
3| Blue| -VDC
4| Black| Relay 1
5| Grey| Com
6| Yellow| +mA or +V

Dimensions

Dimensions (mm)

Model Selection

Warranty, Returns, and Limitations

Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service by instructions furnished by Icon Process Controls Ltd for one year from the date of sale of such products. Icon Process Controls Ltd’s obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd’s option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified under the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for one year from the date of replacement.

Returns
Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective, go to www.iconprocon.com, submit a customer return (MRA) request form, and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment.

Limitations
This warranty does not apply to products that: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical, or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of potentially hazardous material present with the product, or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE, AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted under the laws of the province of Ontario, Canada.

If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.

For additional product documentation and technical support visit:www.iconprocon.com | e-mail: sales@iconprocon.com or support@iconprocon.com | Ph: 905.469.9283.

24-0199 © Icon Process Controls Ltd.