HITACHI RAS-08KH2 Split Unit Air Conditioner Instruction Manual

July 17, 2024
Hitachi

HITACHI RAS-08KH2 Split Unit Air Conditioner

Product Information

Specifications:

  • Indoor Unit Model: RAS-08KH2 (8,000 BTU), RAS-10KH2 (10,000 BTU)
  • Outdoor Unit Model: RAC-08KH2, RAC-10KH2
  • Refrigerant Type: R410A
  • Installation Type: Split Unit Air Conditioner

Product Usage Instructions:

1. Safety Precautions:

Read the safety precautions carefully before operating the unit. Incorrect methods of installation may cause death or serious injury. Improper installation may result in serious consequences.

2. Installation Guidelines:

Before starting the installation work, carefully read through the procedures outlined in the installation manual.

The sales agent should inform customers about the correct operation of installation.

3. Tools Needed For Installation Work:

Ensure you have all the necessary tools required for installation work.

4. Electrical Work:

Observe the rules and regulations of electrical installation and follow the methods described in the installation manual when dealing with electrical work.

Use power cables approved by the authorities of your country.

5. Connection and Piping:

Use the specified wire for connecting the indoor and outdoor units. Ensure tight connections to prevent over-heating and fire.

Use the specified piping set for R410A to avoid broken copper pipes or faults.

6. Refrigerant Handling:

Ensure no air or moisture remains in the refrigeration cycle during installation or removal of the air conditioner to prevent
abnormal pressure buildup.

Ventilate fully in case of a refrigerant gas leak to avoid poisonous gas formation.

7. Post-Installation Checks:

After completion of installation work, check for refrigerant gas leakage to prevent exposure to poisonous gas in case of a fire.

FAQs

  • Can I install the air conditioner myself?
    • No, please request your sales agent or a qualified technician to install the unit to avoid water leakage, short circuit, or fire hazards.
  • What should I do if there is a refrigerant gas leak?
    • If a refrigerant gas leak occurs, ensure proper ventilation as contact with fire may lead to poisonous gas formation.

FOR SERVICE PERSONNEL ONLY

SPLIT UNIT AIR CONDITIONER INSTALLATION MANUAL

Indoor Unit

Outdoor Unit

RAS-08KH2 RAS-10KH2

RAC-08KH2 RAC-10KH2

Carefully read through the procedures of proper installation before starting installation work.
The sales agent should inform customers regarding the correct operation of installation.
Tools Needed For Installation Work
+ ­ Screwdriver Measuring Tape Knife Saw ø 65mm Power Drill Hexagonal Wrench Key ( 4mm) Wrench (14, 17, 22mm) Gas Leakage Detector Pipe Cutter Putty Vinyl Tape Pliers Flare Tool

SAFETY PRECAUTION

Read the safety precautions carefully before operating the unit. The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
! WARNING …….. Incorrect methods of installation may cause death or serious injury. ! CAUTION ……… Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit as described in the user’s guide.

! WARNING
Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the installation work yourself.
Please observe the instructions stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric shock and fire.
Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and impose danger.
Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work. Use power cables approved by the authorities of your country.
Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating and fire.
Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock and fire may occur.
Be sure to use the specified piping set for R410A. Otherwise, this may result in broken copper pipes or faults.
When installing or removing an air conditioner, do not allow air or moisture to remain in the refrigeration cycle. Otherwise, pressure in the refrigeration cycle may become abnormally high so that a rupture may be caused.
Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may occur.
After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.
Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc.

! CAUTION
A circuit breaker or fuse must be installed. Without a circuit breaker or fuse the danger of electric shock exists. A main switch with a contact gap of more than 3mm has to be installed in the power supply line to the outdoor unit.
Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose. Piping shall be suitable supported with a maximum spacing of 1m between the supports.

THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation).

! WARNING

! WARNING

The unit should be mounted at stable, non-vibratory location which can provide full support to the unit.

The Outdoor unit must be mounted at a location which can support heavy weight. Otherwise, noise and vibration will increase.

INDOOR UNIT OUTDOOR UNIT

! CAUTION
No nearby heat source and no obstruction near the air outlet is allowed.
The clearance distances from top, right and left are specified in figure below.
The location must be convenient for water drainage and pipe connection with the Outdoor unit.
To avoid interference from noise please place the unit and its remote controller at least 1m from the radio, television and inverter type fluorescent lamp.
To avoid any error in signal transmission from the remote controller, please put the controller far away from high-frequency machines and high-power wireless systems.
The installation height of indoor unit must be 2.3m or more in a non public area.

! CAUTION
Do not expose the unit under direct sunshine or rain. Besides, ventilation must be good and clear of obstruction.
The air blown out of the unit should not point directly to animals or plants. The clearances of the unit from top, left, right and front are specified in
figure below. At least 3 of the above sides must be open air. Be sure that the hot air blown out of the unit and noise do not disturb the
neighbourhood. Do not install at a location where there is flammable gas, steam, oil and
smoke. The location must be convenient for water drainage. Place the Outdoor unit and its connecting cord at least 1m away from the
antenna or signal line of television, radio or telephone. This is to avoid noise interference. Do not install outdoor unit facing strong wind direction. It may damage the fan motor.

Names of Indoor Components

No.

Item

Qty

Hanger

1

1

The Length of Indoor Unit Connecting Cord

0.8m

1.5m

Figure showing the Installation of Indoor and Outdoor Unit.

! CAUTION
· The installation height
of indoor unit must be 2.3m or more in a non public area.

Screw for Hanger

2

6

(4.1×32)

Holder for Remote

3 Controller

1

AAA Size Battery

4

2

Screw for holder of

5 Remote Controller

2

(3.1×16)

Remote Controller

6

1

Direction of Piping

Horizontally perpendicular to the unit
Connection
There are 4 directions allowed, namely, horizontally perpendicular to the unit, vertically down from right, horizontally out from right and horizontally out to left. Don’t form the piping downward at the left of the unit.

Dimension of Mounting Stand of the Outdoor unit

(unit : mm)
mounting stand

35 12

Be sure to completely seal any gap with putty.

8 225

Purifying Filter

7

1

35 500
100

Holder

8

1

Names of Outdoor Components

No.

Item

Qty

Drain Pipe

9

1

Bush

0

2

above 200mm above 50mm when installed on the ceiling of balcony
above 100mm
above 300mm

above 300mm above
must not bend 0.45m

Maximum pipe length 10m Minimum pipe length 5m

above 50mm above 100mm

2 1

above 100mm 2,300mm or more

6 54

3 Plug

The indoor piping should be insulated with the enclosed insulation pipe. (If the insulator is insufficient, please use commersial products).

above 100mm
give clearance as wide as possible

The difference in height between the indoor and outdoor unit should be kept max 5m.
The connecting pipe, no matter big or small, should all be insulated with insulation pipe and then wrapped with vinyl tape. (The insulator will deteriorate if it is not wrapped with tape).

above 200mm

The connection of insulated drain hose.
inner diameter ø 16mm

Please use insulated drain hose for the indoor piping (commercial product).

INDOOR UNIT

1 Installation of Hanger, Wall Penetration and Installation of Protection Pipe
! CAUTION
The draining of the water container inside the indoor unit can be done from the left. Therefore the hanger must be fixed horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water may overflow the water container.

Installation of the Indoor Unit

VERTICALLY DOWNWARD PIPING
Preparation Connect connecting cord. Pull out the pipe, connecting cord and drain hose.

Direct Mounting On The Wall
Please use hidden beams in the wall to hold the hanger.

200mm

125mm

Installation The upper part of the Indoor unit is hanged on the hanger.

Connecting cords, pipe and drain hose must be laid together with Vinyl tape.

The projection at the lower part of the Indoor unit is hooked onto the hanger.

Hanger

1 Hanger

125mm
45mm 60mm

80mm 780mm

280mm

45mm
115mm Level

Refrigerating Pipe

Lift the body of the unit upwards and then force it downwards.

Protection

Pipe

Drain Hose Connecting

Cord

2 Projection

! CAUTION
Please pull the lower part of the Indoor unit outwards to check if the unit is hooked onto the hanger. Improper installation may cause vibration and noise.

Mark

450mm

Hanger

HOW TO REMOVE INDOOR UNIT

Screw for Hanger
Please use more than 4 screws.

Line Weight

Hole for pipe

Procedures of Installation and Precautions

Procedures to fix the hanger.

1. Drill holes on wall. 2. Push plug into the holes.

(As shown below)

(As shown below)

3. Fix the hanger on wall with 4.1 x 32 screw (As shown in figure below)

Push up the (PUSH) sections at the bottom of the indoor unit and pull the bottom plate towards you. Then the claws are released from the stationary plate. (The (PUSH) sections are indicated by 2 arrows in the right figure)
HORIZONTAL PIPING

[Push] mark positions

Ceiling

Preparation

Wall

1 Hanger

Plug

above 50mm

Change of Drain Hose and Installation Procedures.

2 Screw

Exchange the location of drain hose and drain cap during horizontal piping as shown in

figure below. Be sure to plug in the drain hose until the insulating material folds upon itself.

32mm
Wall

4.1 x 32 Screw

Please use pliers to pull out the drain cap. (This is an easier way to remove the drain cap).

Procedures to fix the holder of remote control.

1. Drill holes on wall. 2. Push plug into the holes.

(As shown below)

(As shown below)

Wall
20mm

3 Remote Control Holder

5 Screw Plug

Wall Penetration and Installation of Protection Pipe

Drill a ø 65mm hole on wall which is slightly tilted towards the outdoor side. Drill the wall at a small angle.
Cut the protection pipe according to the wall thickness.
Empty gap in the sleeve of protection pipe should be completely sealed with putty to avoid dripping of rain water into the room.

Indoor Seal with putty
Protection pipe

WALL

Outdoor 2 ~ 5mm
Seal with putty
Sleeve of protection pipe

! WARNING
Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing through the hollow part of the wall so as to prevent the possibility of damaged by mouse. Unless it seals completely, any air with high humidity flows from outdoor and any dew may drop.

Drain cap

Drain hose

Drain cap
Please insert until here

Drain hose
Please insert until here

! CAUTION Condensed water may leak out if not inserted properly.

HORIZONTAL & DOWNWARD PIPING ­ MAKING OPENINGS

During horizontal or downward piping, use a knife to cut openings as shown in figure. Then smoothen the edges of openings with a file.

Pipe support

Openings

Pull up the pipe after Turn the piping while holding down the lower

bending downward

portion of pipe-support by hand.

INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION

The refrigerating pipes should be adjusted to fit into the hole on the wall and then ready for further connection.
The terminals of 2 connected pipes must be covered with insulator used for terminal connection. Then the pipes are wrapped with insulation pipe.
Connect the connecting cord after removing electrical cover. (Refer to “CONNECTION OF POWER CORD”)
After adjustment, fit the connecting cord and pipes into the space available under the indoor unit. Use holder to hold them tight.

Drain hose

Pipe

Connecting cord

! CAUTION
The rubber strap used for

fixing the insulator should

8 Holder Insulation pipe (must be wrapped with vinyl tape at every 120mm).

not be tied with great force. Otherwise, this will damage heat insulation and causes water condensation.

Holder can be attached at the either of 2 places. Please select the easier position.

Pipe

Rubber strap tied with great force

THE CONNECTION OF REFRIGERATING PIPE DURING THE INSTALLATION OF INDOOR UNIT

Preparation To Install Refrigerating Pipes
The refrigerating pipes and connecting cord transform and are attached.
The end of the refrigerating pipes are at locations marked with ” ” symbol.

! CAUTION
Please fix in the plastic core after flaring to avoid plastic chips entering the pipes.

0.85m

Please bend at a small radius to form an arc

below 5mm

Installation

Hang the Indoor unit onto the hanger. Use the temporary stand at the back of the Indoor unit to push its lower part 15cm forwards. Place the drain hose through the hole on the wall. Wrap the refrigerating pipes with insulation pipe after
connecting refrigerating pipe. Connect the connecting cord after removing electrical cover.
(Refer to “Connection of Power Cord”) After adjustment, the connecting cord and refrigerating pipes
are placed into the space available under the Indoor unit. The projection of Indoor unit must hook to the hanger.

Projection

Hook about 15cm

Heat insulation pipe
Connecting cord Refrigerating pipe

Pull this to the front during the connection of refrigerating pipes to ease task.

Protection pipe Drain hose
Connecting cord

Holder Connected section

3 Installation of Drain Hose

! CAUTION

Bending upwards

Condensed water pond

Ditch

Condensed water pond

Be sure that the drain hose is not loosely connected or bend.

!

You are free to choose the side (left or right) for the installation of drain

hose. Please ensure the smooth flow of condensed water of the Indoor

CAUTION unit during installation. (Carelessness may result in water leakage.)

OUTDOOR UNIT

100 mm ABOVE
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL

Mount the outdoor unit on stable ground to prevent vibration and increase of noise level.
Decide the location for piping after sorting out the different types of pipe available.

Procedure to remove the cover of wiring terminals
Remove the screw (1 piece).
Hold the projected part at the lower left of the cover and push the cover upwards to remove it.
To close the cover,
Hook
insert the upper part of the cover into the body of outdoor unit, then be sure that the hook below the cover is plugged in before screwing.

Please face this side (suction side) of the unit to the wall
Please remove the cover for wire connection.

CONDENSED WATER DISPOSAL OF OUTDOOR UNIT There are holes on the base of Outdoor unit for condensed water to exhaust. In order to flow condensed water to the drain, the unit is installed on a stand or a block so that the unit is 100mm above the ground as shown figure. Join the drain pipe to one hole. At first insert one portion of the hook to the base (Portion A), then pull the drain pipe in the direction shown by the arrow while inserting the hook into the base. After installation, check whether the drain pipe cling to the base firmly.
A
BASE

DRAIN PIPE

10 Bush

9 Drain Pipe

When using in cold region, etc.
In cold region with severe cold climate and heavy snow, water discharged from heat exchanger freeze on the base surface and this may affect drainage. In such a region, remove bush on the bottom face of outdoor unit for better drainage. When using drainpipe, consult our dealer.

1 Preparation of Pipe
Use a pipe cutter to cut the copper pipe.
Copper pipe

Trimming tool

! CAUTION
Jagged edge will cause leakage. Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.

Before flaring, please put on the flare nut.

Die

Die

A

Please use exclusive

tool

Copper pipe

3 Removal Of Air From The Pipe And Gas Leakage Inspection

Procedures of using Vacuum Pump for Air Removal
As shown in right figure, remove the cap of valve core. Then, connect the charge
1 hose. Remove the cap of valve head.
Connect the vacuum pump adapter to the vacuum pump and connect the charge hose to the adapter.

Fully tighten the “Hi” shuttle of the

manifold valve and completely unscrew

2

the “Lo” shuttle. Run the vacuum pump for about 10­15 minutes, then completely

tighten the “Lo” shuttle and switch off

the vacuum pump.

When the meter reaches – 101KPa (-76cmHg) during pumping, fully tighten the shuttle.
Meter showing pressure

Closed

Lo Hi Charge hose Valve
Valve

R410A Manifold valve
Vacuum pump

Vacuum pump adapter

When pumping starts, slightly loosen the flare nut to check of air sucked in. Then tighten the flare nut.

AIR REMOVAL

Outer Diameter (mm)
6.35 9.52

A (mm)

For R410A tool
0.0 ~ 0.5mm 0.0 ~ 0.5mm

For R22 tool 1.0mm 1.0mm

Completely unscrew the spindle of the

3

service valve (at 2 places) in anticlockwise direction to allow the flow of

coolant (using Hexagonal Wrench key).

2 Pipe Connection

In case of removing flare nut of an Indoor unit, first remove a nut
! CAUTION of small diameter side, or a seal cap of big diameter side will fly
out. Prevent water from entering into the piping when working.

Please be careful when bending the copper pipe.

Screw in manually while adjusting the center. After that, use of torque wrench to

tighten the connection.

Outer

Torque N·m

dia.of pipe

(kgf · cm)

Flare nut

Small dia. side Large dia. side

6.35 (1/4″) 13.7 ­ 18.6 (140 ­ 190) 9.52 (3/8″) 34.3 ­ 44.1 (350 ­ 450)

Wrench

Torque wrench

Valve Small dia. side head cap Large dia. side
Valve core cap

6.35 (1/4″) 19.6 ­ 24.5 (200 ~ 250) 9.52 (3/8″) 19.6 ­ 24.5 (200 ~ 250)
12.3 ­ 15.7 (125 ~ 160)

Remove the charge hose and tighten the

4

cap of valve head. Check the cap’s periphery if there is any gas leakage.

The task is then completed.

Gas Leakage Inspection
Please use gas leakage detector to check if leakage occurs at the connection of Flare nut as shown on the right.
If gas leakage occurs, further tighten the connection to stop leakage.

The body of service valve

Cap of valve head

Cap of valve core
Hexagonal Wrench Key

Cap of valve head

! WARNING THIS APPLIANCE MUST BE EARTHED.
Procedures of Wiring

In case that power is supplied from Indoor Unit

Line Cord

Indoor Unit
L N
ABCD

AC 220-240V

Outdoor Unit
ABCD 2.0 Connecting Cord

Wiring Of The Indoor Unit
For wire connection of the Indoor unit, you need to remove low cover and front cover. Method to remove front cover. Refer to “FINAL STAGE OF INSTALLATION ­ How to Remove The Front Cover”.
Method to remove the low cover
Pull the cover at 1 and 2 in the directions as shown by arrows to remove the cover.

1.6 or 2.0

Indoor Unit
Outdoor Unit

Power line 30mm 10mm

Control line 30mm 10mm

10mm 70mm 25mm
10mm

GRN + YEL
Strip wires
25mm 10mm

GRN + YEL

10mm 35mm

! WARNING
The naked part of the wire core should be 10 mm and fix it to the terminal tightly. Then try to pull the individual wire to check if the contact is tight. Improper insertion may burn the terminal.
Be sure to use only power cables approved from the authorities in your country. For example in Germany: Cable type: NYM 3×1.5mm2.
Please refer to the installation manual for wire connection to the terminals of the units. The cabling must meet the standards of electrical installation.
There is an AC voltage drop between the L and N terminals if power is on. Therefore, before servicing, be sure to remove the plug from the AC outlet or switch off the main switch.

Wiring of The Outdoor Unit
Please remove the side cover for wire connection.

!
WARNING

If you cannot attach the side cover due to the connecting cord, press the connecting cord in direction to the front panel to fix it.
Be sure that the hooks of the side cover is fixed in certainly. Otherwise water leakage may occur and this causes short circuit or faults.
The connecting cord should not touch to service valve and pipes. (It becomes high temperature in heating operation.)

Checking for the electric source and
the voltage range
Before installation, the power source must be checked and necessary wiring work must be completed. To make the wiring capacity proper, use the wire gauges list below for the lead-in from a pole transformer and for the wiring from a switch board of fuse box to the main switch and outdoor unit in consideration of the locked rotor current.

IMPORTANT
Cable length up to 16m up to 15m up to 25m

Wire cross-section 1.6mm2 2.5mm2 4.0mm2

After remove the screw and cover, and put the connecting cords and fix the cover with screw.

A

B

CD

Connection wire

Side cover
Connection wire is put under here
Screw for earth line

Investigate the power supply capacity and other electrical conditions at the installation location. Depending on the model of room air conditioner to be installed, request the customer to make arrangements for the necessary electrical work etc. The electrical work includes the wiring work up the outdoor. In localities where electrical conditions are poor, use of a voltage regulation is recommended.

IMPORTANT
Fuse Capacity 10A time delay fuse

CONNECTION OF POWER CORD

FINAL STAGE OF INSTALLATION

1 Insulation And Maintenance Of Pipe Connection
The connected terminals should be completely sealed with heat insulator and then tied up with rubber strap.
Please tie the pipe and power line together with vinyl tape as shown in the figure showing the installation of Indoor and Outdoor units. Then fix their position with holders.
To enchance the heat insulation and to prevent water condensation, please cover the outdoor part of the drain hose and pipe with insulation pipe.
Completely seal any gap with putty.
Insulation material for pipe connection

2 Installation Of Remote Controller
The remote controller can be placed in its holder which is fixed on wall or beam.
To operate the remote controller at its holder, please ensure that the unit can receive signal transmitted from the controller at the place where the holder is to be fixed. The unit will beep when signal is received from the remote controller. The signal transmission is weaken by the fluorescent light. Therefore, during the installation of the remote control holder, please switch on the light, even during day time, to determine the mounting location of the holder.

Sleeve of protection pipe

Putty

Putty
3 Power Source And Operation Test

The controller must be hooked onto the hook at the lower part of the holder. Push in the remote controller in the direction as shown in figure below.

Screw (2 pieces)

Remote Controller

Holder for Remote Controller

Power Source

Operation Test

! CAUTION
Please use a new socket. Accident may occur due to the use of old socket because of poor contact.
Please plug in and then remove the plug for 2 ­ 3 times. This is to ensure that the plug is completely plugged into the socket.
Keep additional length for the power cord and do not render the plug under external force as this may cause poor contact.
Do not fix the power cord with U-shape nail.

Please ensure that the air conditioner is in normal operating condition during the operation test.
Explain to your customer the proper operation procedures as described in the user’s manual.

How to Remove The Front Cover
1 Remove the front panel. Please remove and attach the front panel by both hands.
1 After opening the front panel by both hands. Undo the right arm while pushing it inside.
2 Slide the front panel to right as shown in figure. Then remove while pulling it to front. 2 Remove the filters. 3 After removing two screws, pull the center of the front cover towards you and release the claws. 4 Pull the side faces (lower sections) of the front cover towards you as shown in the figure and remove the cover.

How to Attach the Front Cover
1 Check that the drain pan is securely attached.
2 After installing the front cover onto the unit, hook three claws at upper side of the cover securely. Then, push the center of the front cover to lock the claws.
3 Tighten the two screws.

4 Install the filter.
5 Slide the shafts of the right and left arms on the washable panel along the steps to insert the shafts into the holes till they stop. After checking that the shafts are securely inserted, close the panel.
Shaft

Hole

Step